Post Buy Requirement

Lamination, Wrapping & Banding Machines

We offer a complete product range of PRIME Gel Documentation Systems, Gel Documentation System, Gel.LUMINAX Gel Documentation Systems and Gel.ProCCD Sensitive Gel Documentation Systems

PRIME Gel Documentation Systems

1.50 Lakh - 1.70 Lakh /Piece Get Latest Price
  • Min. Order (MOQ) 1 Piece
  • Condition New
  • Automatic Grade Manual, Semi Automatic
  • Driven Type Mechanical
  • Warranty 1year
  • Country of Origin India
  • Brand Name Zenith
  • Classification Gel Doc
  • Resolution 12 MP
  • Light Source UV

Simple to use, 12 megapixel digital camera based gel documentation systems. With removable hood and ultraviolet transilluminator, so that the transilluminator can be used separately to view gels.

One of the easiest to use systems for gel documentation and electrophoretic imaging applications, theGel.PRIMEstands alone to provide the lowest cost yet high quality scientific gel visualization and analysis digital system for classrooms and labs.
TheGel.PRIMEgel doc system offers reproducible, high-resolution digital images for gel documentation and imaging.Gel.PRIMEis ideal if you have a limited budget because we have a lot of options for you. Purchase the basic system with the camera, transilluminator, darkroom hood and later add a printer or gel analysis software as the need arises.
Featuring a 12 megapixel digital camera, the camera connects to a PC through a USB and can be controlled from the PC. Ultraviolet transillumination can be provided in 254nm, 312nm or 365nm ranges. Filter size of transilluminator is 20x20 cm. Maximum gel size that can be captured is 16x20 cm.
The transilluminator can be used separately too, in case the user just wants to observe the gel.

How the Gel Documentation System works

A transilluminator and a removable, light-weight hood with camera is supplied. The camera is mounted on top of the hood. Simply put the gel on the transilluminator and then place the hood over the transilluminator. Switch on the transilluminator and the camera.
View the gel on the camera built-in LCD or connect the camera to a PC using USB to get a real-time live view image of the gel. Adjust camera settings (like shutter speed, aperture, focus) directly on the camera or using the provided gel capture software that controls the camera from the PC. Click your images and save them on the PC.
With the optional 1D gel analysis software, you can analyse the gels.

Features

- 12 megapixels- 8 bit grayscale- 24 bit RGB- Excellent image quality- 3x manual optical zoom- EtBr 590 filter- 312nm / 254nm / 365nm UV- Use transilluminator separately

Advantages

- Easy to use- Low cost, yet high quality images- Control camera from PC- Adjust camera focus, clicking, shutter speed, aperture from PC- Use the camera separately- Camera mounted conveniently- Easy access to transilluminator- Small foot print requires less space

Convenient and easy-to-use Gel Capture software has options for adjusting the shutter speed, aperture, focus, directory, rotation etc. You can view the gels live on the screen and capture the image using the software. This software is provided standard with the gel documentation system.
Package Includes

- Dark hood- Variable intensity 312nm transilluminator- UV safety polymer for transilluminator- 12 megapixel camera- Gel capture software- 590nm filter, suitable for EtBr stained gels- Power cords, USB cable, instruction manual, warranty card

Additional Information:

Payment Terms :

Packaging Details : PVC and Wooden

Delivery Time : 7 days

View Complete Details

Gel Documentation System

One of the easiest to use systems for gel documentation and electrophoretic imaging applications, theGel.PRIMEstands alone to provide the lowest cost yet high quality scientific gel visualization and analysis digital system for classrooms and labs.

TheGel.PRIMEgel doc system offers reproducible, high-resolution digital images for gel documentation and imaging.Gel.PRIMEis ideal if you have a limited budget because we have a lot of options for you. Purchase the basic system with the camera, transilluminator, darkroom hood and later add a printer or gel analysis software as the need arises.

Featuring a 12 megapixel digital camera, the camera connects to a PC through a USB and can be controlled from the PC. Ultraviolet transillumination can be provided in 254nm, 312nm or 365nm ranges. Filter size of transilluminator is 20x20 cm. Maximum gel size that can be captured is 16x20 cm.

The transilluminator can be used separately too, in case the user just wants to observe the gel.

How the Gel Documentation System works

A transilluminator and a removable, light-weight hood with camera is supplied. The camera is mounted on top of the hood. Simply put the gel on the transilluminator and then place the hood over the transilluminator. Switch on the transilluminator and the camera.
View the gel on the camera built-in LCD or connect the camera to a PC using USB to get a real-time live view image of the gel. Adjust camera settings (like shutter speed, aperture, focus) directly on the camera or using the provided gel capture software that controls the camera from the PC. Click your images and save them on the PC.
With the optional 1D gel analysis software, you can analyse the gels.

Features

- 12 megapixels- 8 bit grayscale- 24 bit RGB- Excellent image quality- 3x manual optical zoom- EtBr 590 filter- 312nm / 254nm / 365nm UV- Use transilluminator separately

Advantages

- Easy to use- Low cost, yet high quality images- Control camera from PC- Adjust camera focus, clicking, shutter speed, aperture from PC- Use the camera separately- Camera mounted conveniently- Easy access to transilluminator- Small foot print requires less space

Convenient and easy-to-use Gel Capture software has options for adjusting the shutter speed, aperture, focus, directory, rotation etc. You can view the gels live on the screen and capture the image using the software. This software is provided standard with the gel documentation system.
Package Includes

- Dark hood- Variable intensity 312nm transilluminator- UV safety polymer for transilluminator- 12 megapixel camera- Gel capture software- 590nm filter, suitable for EtBr stained gels- Power cords, USB cable, instruction manual, warranty card

Optionals are

- Transilluminator in 365nm, 254nm or dual wavelengths- 1D Gel Analysis software
View Complete Details

Gel.LUMINAX Gel Documentation Systems

Easy to use, low-cost, high quality mini-darkroom digital gel documentation systems. With a safe mini-darkroom with a roll-out transilluminator and 18 megapixel camera, 8-bit JPEG and 14-bit tif images with epi-white light. Gel camera is controllable from PC.

Excellent optics coupled to a high quality camera, theGel.LUMINAXgel documentation system, is a high performance and reliable fluorescent and colorimetric bio-imaging system.
Featuring a 18 megapixel digital camera, the camera connects to a PC through a USB and can be controlled from the PC. The light-tight cabinet has a UV safety switch and a roll-out transilluminator. A choice of illumination options with UV trans/epi lighting, wavelengthspecificLEDs and more, adds to the versatility of the system.
Ultraviolet transillumination can be provided in 312nm, 365nm or 254nm ranges. Filter size of transilluminator is 20x20 cm or 21x26cm. For extra large gels, we also offer a 26x26cm filter transilluminator. Epi-white light illumination from above is standard. Optionally, ultraviolet epi-illumination in a variety of wavelengths can also be provided.
The dark room cabinet has features for safety switch that switches off the UV lights as soon as the door is open. A timer is attached to the transilluminator, which auto switches off UV light in case the user forgets to switch it off. This increases the life of the UV lamps.
This gel doc system is perfect for diagnostic labs, biotech start-ups, for HLA-typing facilities, DNA and protein research and academic labs.

Gel.LUMINAXgel documentation system is used to capture images of:- Protein and DNA gels, - HLA typing applications, - Petri plates and Agar plates, - Tissue Culture Flasks, - Membranes, - TLC plates, - Microplates

A comparison was done between the performance of our gel doc transilluminator and a European system. The same EtBr-stained gel was viewed and photographed in our system and then immediately again (so that the lighter bands did not diffuse) on a famous European-brand system. The camera settings were the same and transilluminators intensity set at maximum in both transilluminators. Post processing involved cropping & pasting the gel images together and the text annotations shown in image above. No processing was done to deliberately lighten the bands in the European-brand transilluminator. This comparison was done at a large biotech company in Bangalore (India) that had access to both our and the other transilluminator.
Clearly, our system performs better than the European brand despite being much less in price.

How the Gel Documentation System works

A transilluminator is mounted on roll-out rails inside a light-tight cabinet. To place the gel, the door is opened and transilluminator pulled out. Push it in, close the door and switch on the UV light and camera. The camera is mounted on top of the cabinet along with zoom lens and wavelenght filter (nominally 590nm filter suitable for Ethidium Bromide EtBr gels is provided).
Connect the camera to the PC using the USB cable and gel capture software, to get a real-time live view image of the gel. Adjust camera settings (like shutter speed, aperture, focus) till the optimum image is obtained. Click your images and save them on the PC. A white light epi-illuminations source is also provided, that illuminates objects from top.
With the optional 1D gel analysis software, you can analyse the gels.

Features

- Low Noise CMOS imaging sensor- 8-bit and 14-bit options- 18 megapixel cameras- Excellent dynamic range- 3.0 orders of magnitude, 58 dB- Superior signal-to-noise- Sharp Zoom lens- Motorized auto-focus- Motorized aperture setting- Manual zoom range 3x- Exposure from 0.00025s onwards- Single/Dual 312nm/365nm/254nm UV- RGB LEDs and convertor screens- Operate camera via PC- Timer for auto-off of UV- Advanced Gel Analysis Software

Filters

- Options for filter holders- Standard is manual 3-position filter holder- Advanced models with 7-position motorized filter holder available- Orange 590 EtBr and clear are standard
Choice of filters available for these stains:- Orange 590: Ethidium Bromide (EtBr), SYPRO Ruby, ProQ Diamond, Deep Purple, etc- Green 520: SYBR Green I, Green II, SYBR Gold, GFP, Fluorescein, FITC- Orange 560: SYBR Safe, Rhodamine, Cy3, etc- Red 630: SYPRO Red, Texas Red, etc- Blue 480: Hoechst, Coumarin, etc- Clear: Coomassie Blue, Silver etc

Lighting

- Standard lighting systems are UV transillumination in 302-312nm* and Epi-white light- Gel filter illumination area is 20x20cm, with 21x26cm option for larger gels. For extra large gels, we also offer a 26x26cm filter.- Gels up to a maximum of 26x26cm can be observed, captured and analysed- Sample size area is 38x30cm- We also offer UV transillumination in dual wavelength (312+365nm being most common)- For rare applications UV transillumination in triple wavelength (254+312+365nm) can also be given- Multi broad band wavelengths can also be offered 254nm, 312nm and 365nm UV trans lights- Intensity control for low and high trans-illumination - low for preparative work and high for quantitative- White light tables are optional to use gel doc for protein gels documentation- For special stains, blue light tables can also be given- Multi-wavelength epi-illumination LEDs are also available for Red, Green, Blue lights for special stains
* Please note that 300nm, 302nm, 306nm and 312nm are in the same range of wavelengths called UV-B (also known as mid-range). Some manufacturers quote 302nm but it is the same as 312nm.

Advantages

- Easy to use, safe dark-room- Low cost, yet high quality images- Control camera from PC- Focus, clicking, exposure from PC- Camera mounted conveniently- Easy access to transilluminator- Small foot print requires less space- Superb performance/price

Convenient and easy-to-use Gel Capture software has options for adjusting the shutter speed, aperture, focus, directory, rotation etc. You can view the gels live on the screen and capture the image using the software. This software is provided standard with the gel documentation system.

Package Includes

- Dark room cabinet with safety switch- Roll out variable intensity 312nm transilluminator- Epi-white light illumination- 18 megapixel camera- Gel capture software- 590nm filter, suitable for EtBr stained gels- Power cords, USB cable, instruction manual, warranty card

Optionals are

- Transilluminator in 365nm, 254nm or dual or triple wavelengths- Epi-illumination in multiple wavelength LEDs- Gel Analysis software

- Tablet with touch screen to give a stand-alone gel documentation setup

View Complete Details

Gel.ProCCD Sensitive Gel Documentation Systems

Super-sensitive yet affordable CCD camera based gel documentation systems. Darkroom with transilluminator and other lighting options. Manual and motorized lenses and filter holders. 1.4, 5.6 and 9 megapixel CCD cameras, with 12-bit and 16-bit pixel depth TIFF mages. Fast and accurate documentation and analysis of fluorescent and colorimetric gels

Sharp zoom lens coupled to a highly sensitive 16-bit Sony scientific grade CCD camera, the Gel.ProCCD gel documentation system, is a high quality, yet low cost professional gel and bio-imaging system. From agarose, PAGE, western blots, dot blots, nucleic acid, colorimetric to fluorescent imaging and upgradeable to chemiluminescence; this gel system has all the options.

Featuring high resolution extremely sensitive scientific grade CCD camera (with choice of 1.4, 5.6 and 9 megapixel cameras) with extremely low noise and dynamic flat field calibration coupled to a motorized zoom lens (with an option for numerical feedback value) that is pre-focussed for different zooms or sample setting, mounted in an enclosure that covers and protects the camera and lens from dust and mold. The camera, lens and cabinet connects to and can be controlled from the PC using the live-view acquisition capture software.

Choice of illumination options with long-life UV trans/epi lighting, wavelength-specific LEDs and more, add to the versatility of the system. UV roll-out transilluminator can be provided in single, dual 302-312nm and 365nm (additionally 254nm, for triple wavelength configuration), and even Red, Green, Blue LEDs ranges. Large filter size of transilluminator for gel images up to 21x26cm, with extra large special filter size of up to 26x26cm also is available.

Colorimetric samples up to 38x30cm can be captured. Epi-white light illumination from above is standard using two LED tubes. Optionally, ultraviolet epiillumination in a variety of wavelengths (254/312/365nm) can also be provided. UV to white light and UV to blue light trans converter screens are also available. UV tubes and LED lamps are high-quality, long-life tubes and lamps, with the latter lasting for more than 40, 000 hours of usage (under proper usage with flicker-less, stabilized power supply). Reflectors are standard for uniform light distribution.

The mild & stainless steel, epoxy coated microprocessor controlled dark room cabinet has features for UV irradiation safety switch that switches off the UV lights as soon as the door is opened. Additionally, a timer is provided that switches off UV in case the user forgets to shut it off. Option to adjust timer for excision. Also, the user can opt for automatic switching on of the Dual Epi-White LEDs on opening of door and for automatic controls of UV light and exposure. A transilluminator cooling system is also provided to prevent overheating of gels. Optionally, a window and access door can be provided for gel observation and cutting. And, a gel platform temperature control
(4.0 orders of magnitude- EtBr 590 filter standard- 312nm / 254nm / 365nm UV or any dual or triple combinations of these wavelengths- Operate camera, lens and dark-room cabinet via PC

Advantages

- Easy to us- Low cost, yet highly sensitive- Control camera, lens, cabinet and transilluminator from PC using a microprocessor based controller- Adjust camera lens focus, clicking, shutter speed, aperture from PC- Camera mounted safely inside a dust-protective enclosure- Easy access to transilluminator- Safety interlock switches shuts UV off as soon as door opens- Small foot print requires less space

Applications

- Gel Capture and Analysis- Fluorescent Imaging- Protein Electrophoresis Imaging- Western Blotting Imaging- Colony and Petri Imaging- Upgrade to chemiluminescent imaging


Camera Specifications

- Standard model cameras have 16-bit pixel depth (65, 536)- Budgetary model cameras of 12-bit pixel depth (4, 096) also available- Cameras use high quality scientific grade Sony CCD imaging sensors- Standard models cameras have 1.4, 5.6 and 9 megapixel high resolution cameras in 16-bit sensitivity- Pixel size are 4.6x4.6um to 6.5x6.5um- Camera sensors are flat-field calibrated- Also available are cameras with 12-bit sensitivity for budgetary applications- Anti-reflective, microlens sensor- Exposure Control from 0.01s to 100s- 16-bit grayscale tiff images- Superior signal-to-noise ratio, 68 dB- Excellent dynamic range, >4.0 OD in 16-bit cameras- >3.5 orders of magnitude in 12-bit cameras- Operate camera, lens and dark-room cabinet via PC using microprocessor based control system

Lens Specifications

- Standard model have manual or motorized zoom lens- Zoom ranges available are 8-48mm and 8.5-51mm- Special ranges of zoom are also available: 5-50mm and 12-75mm- For highly sensitive applications fixed lens are availabe in 17mm, 25mm and 50mm focal lengths- Aperture is F1.2- All lenses have focus, iris and zoom control- In motorized lenses, focus, iris and zoom control are controllable from PC software using microprocessor based control system- In manual lenses, focus, iris and zoom control are controlled manually

Filters

- Options for filter holders- Standard is manual 3-position filter holder- Advanced models with 7-position motorized filter holder available- Orange 590 EtBr and clear are standard
Choice of filters available for these stains:- Orange 590: Ethidium Bromide (EtBr), SYPRO Ruby, ProQ Diamond, Deep Purple, etc- Green 520: SYBR Green I, Green II, SYBR Gold, GFP, Fluorescein, FITC- Orange 560: SYBR Safe, Rhodamine, Cy3, etc- Red 630: SYPRO Red, Texas Red, etc- Blue 480: Hoechst, Coumarin, etc- Clear: Coomassie Blue, Silver etc

Lighting

- Standard lighting systems are UV transillumination in 302-312nm* and Epi-white light- Trans illumination area options are 20x20cm for smaller gels and 21x26cm for larger gels- Special size filter to view extra large gels up to a maximum of 26x26cm also available- Sample size area is 38x30cm- We also offer UV transillumination in dual wavelength (312+365nm being most common)- For rare applications UV transillumination in triple wavelength (254+312+365nm) can also be given- Multi broad band wavelengths can also be offered 254nm, 312nm and 365nm UV trans lights- Intensity control for low and high trans-illumination - low for preparative work and high for quantitative- Trans white light tables are optional to use gel doc for protein gels documentation- Excitation wavelengths are UV, white, blue, RGB etc- For special stains, blue light tables can also be given- Multi-wavelength epi-illumination LEDs are also available for Red, Green, Blue lights for special stains- UV blocking polymer filter is also provided to block harmful UV wavelength- Cabinet uses microprocessor based control system to control camera, lens and lighting of the cabinet- Stain-free system (with 30 sec, 2.5 min, 5 min and user-defined UV-on timer)
* Please note that 300nm, 302nm, 306nm and 312nm are in the same range of wavelengths called UV-B (also known as mid-range). Some manufacturers quote 302nm but it is the same as 312nm.

Convenient and easy-to-use Gel Capture software has options for adjusting the shutter speed, aperture, focus, directory, rotation etc. You can view the gels live on the screen and capture the image using the software. This software is provided standard with the gel documentation system.
Gel image acquisition and control software allows user to adjust camera, darkroom, lens settings like exposure time settingngs, motorized zoom, focus and iris aperture. Transilluminator, epi-illuminator, LEDs etc can also be directly controlled from computer. Histogram display on the screen shows image saturation and warns over-saturation/exposure.

Package Includes

- Dark room cabinet with safety switch with low footprint- Roll out variable intensity 312nm transilluminator- Epi-white light illumination- CCD camera- Gel capture software- 590nm orange filter, suitable for EtBr stained gels- Power cords, USB cable, instruction manual, warranty card- Options that can be ordered like motorized filter holder, special zoom lens, illumination etc- 1 year standard warranty against manufacturing defects

Optionals are

- Transilluminator in 365nm, 254nm, dual or multi wavelengths- White or blue light converter tables- Epi-illumination in multiple wavelength (RGB) LEDs- Motorized filter holders- Stain-free system (with 30 sec, 2.5 min, 5 min and user-defined UV-on timer)- UV safety over-ride switch- Gel viewer window in front besides the option to have a UV safety foldable cover on the Transilluminator- Computer Systems of user's specifications and choice- Extended Warranty of 2 year and more are available in addition to 1 year standard warranty against manufacturing defects

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us