Post Buy Requirement

Our Products

  1. Measurement Gauges & Fittings 16 Products available
  2. Measuring Instruments & Equipment 13 Products available
  3. Industrial Valves 6 Products available
  4. Electric Cutting Tools 5 Products available
  5. Rotameters 5 Products available
  6. Flow Meters 5 Products available
  7. Manometers 3 Products available
  8. Medical Accessories

    2 Products available
  9. Valves & Valve Fittings

    2 Products available
  10. Machine And Precision Tools

    1 Products available
  11. Others Products 8 Products available

Rotameters

Our product range contains a wide range of Purge Rotameter, Rotameters, Glass Tube Rotameters, metal tube rotameters and By Pass Rotameters

Purge Rotameter

  • Sizes 15 NB to 100 NB
  • Accuracy ± 2% of FSD.
Operating Principle : Glass Tube Rotameter is basically a Variable Area Flow Meter. The differential pressure across the annulus area is constant and the flow rate is measured as a function of the annulus area. Glass Tube Rotameters consist of a tapered glass tube mounted vertically in a frame with the small diameter at the bottom and large end up. The tube contains a free moving float that rests on the stopper at the base of the tube. When the liquid flows, the float rises until its weight is balanced by the up thrust of the fluid and the float reaches a position of equilibrium. At this position it indicates the instantaneous rate of flow. The flow rate can be read from the adjacent scale.
View Complete Details

Rotameters

  • Available Sizes 15 NB to 100 NB
Operating Principle : Glass Tube Rotameter is basically a Variable Area Flow Meter. The differential pressure across the annulus area is constant and the flow rate is measured as a function of the annulus area. Glass Tube Rotameters consist of a tapered glass tube mounted vertically in a frame with the small diameter at the bottom and large end up. The tube contains a free moving float that rests on the stopper at the base of the tube. When the liquid flows, the float rises until its weight is balanced by the up thrust of the fluid and the float reaches a position of equilibrium. At this position it indicates the instantaneous rate of flow. The flow rate can be read from the adjacent scale.
View Complete Details

Glass Tube Rotameters

  • Available Sizes 15 NB to 100 NB
Operating Principle : Glass Tube Rotameter is basically a Variable Area Flow Meter. The differential pressure across the annulus area is constant and the flow rate is measured as a function of the annulus area. Glass Tube Rotameters consist of a tapered glass tube mounted vertically in a frame with the small diameter at the bottom and large end up. The tube contains a free moving float that rests on the stopper at the base of the tube. When the liquid flows, the float rises until its weight is balanced by the up thrust of the fluid and the float reaches a position of equilibrium. At this position it indicates the instantaneous rate of flow. The flow rate can be read from the adjacent scale.
View Complete Details

Metal Tube Rotameters

  • Accuracy +/- 2% Of Full Scale
Metal tube Rotameters are recommended for liquids or gases where process or operating conditions make all-metal construction desirable. This type of Rotameter is also useful for metering opaque fluids. These are very rugged and robust yet inexpensive for flow rate indication purposes. They can be used for opaque and turbid fluids at high operating temperature and pressures. The Flow is indicated by a pointer, which is magnetically coupled with the float that rises in a tapered tube with increase in flow.
View Complete Details

By Pass Rotameters

By-pass Rotameters are suitable for economical measurement of flow in larger pipelines generally 2" NB to 14" NB. The construction is simple and reliable consisting of orifice plate with carrier ring and a shunt Rotameter. The flow rate through the Rotameter is proportional to the pressure drop across the orifice plate created by the main flow and is calibrated accordingly. During installation care should be taken to ensure laminar flow in the pipe section. Orifice plate dimensions are based on ISA ISOBS standards. By Pass Rotameter is an inference type Flow Meter.
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

Retailer of Rotameters from Delhi, Delhi by Yash International
Post Buy Requirement

Our Products

  1. Measurement Gauges & Fittings 16 Products available
  2. Measuring Instruments & Equipment 13 Products available
  3. Industrial Valves 6 Products available
  4. Electric Cutting Tools 5 Products available
  5. Rotameters 5 Products available
  6. Flow Meters 5 Products available
  7. Manometers 3 Products available
  8. Medical Accessories

    2 Products available
  9. Valves & Valve Fittings

    2 Products available
  10. Machine And Precision Tools

    1 Products available
  11. Others Products 8 Products available

Rotameters

We are leaders in the market for providing best range of Purge Rotameter, Rotameters, Glass Tube Rotameters, metal tube rotameters and By Pass Rotameters

Purge Rotameter

  • Sizes 15 NB to 100 NB
  • Accuracy ± 2% of FSD.
Operating Principle : Glass Tube Rotameter is basically a Variable Area Flow Meter. The differential pressure across the annulus area is constant and the flow rate is measured as a function of the annulus area. Glass Tube Rotameters consist of a tapered glass tube mounted vertically in a frame with the small diameter at the bottom and large end up. The tube contains a free moving float that rests on the stopper at the base of the tube. When the liquid flows, the float rises until its weight is balanced by the up thrust of the fluid and the float reaches a position of equilibrium. At this position it indicates the instantaneous rate of flow. The flow rate can be read from the adjacent scale.
View Complete Details

Rotameters

  • Available Sizes 15 NB to 100 NB
Operating Principle : Glass Tube Rotameter is basically a Variable Area Flow Meter. The differential pressure across the annulus area is constant and the flow rate is measured as a function of the annulus area. Glass Tube Rotameters consist of a tapered glass tube mounted vertically in a frame with the small diameter at the bottom and large end up. The tube contains a free moving float that rests on the stopper at the base of the tube. When the liquid flows, the float rises until its weight is balanced by the up thrust of the fluid and the float reaches a position of equilibrium. At this position it indicates the instantaneous rate of flow. The flow rate can be read from the adjacent scale.
View Complete Details

Glass Tube Rotameters

  • Available Sizes 15 NB to 100 NB
Operating Principle : Glass Tube Rotameter is basically a Variable Area Flow Meter. The differential pressure across the annulus area is constant and the flow rate is measured as a function of the annulus area. Glass Tube Rotameters consist of a tapered glass tube mounted vertically in a frame with the small diameter at the bottom and large end up. The tube contains a free moving float that rests on the stopper at the base of the tube. When the liquid flows, the float rises until its weight is balanced by the up thrust of the fluid and the float reaches a position of equilibrium. At this position it indicates the instantaneous rate of flow. The flow rate can be read from the adjacent scale.
View Complete Details

Metal Tube Rotameters

  • Accuracy +/- 2% Of Full Scale
Metal tube Rotameters are recommended for liquids or gases where process or operating conditions make all-metal construction desirable. This type of Rotameter is also useful for metering opaque fluids. These are very rugged and robust yet inexpensive for flow rate indication purposes. They can be used for opaque and turbid fluids at high operating temperature and pressures. The Flow is indicated by a pointer, which is magnetically coupled with the float that rises in a tapered tube with increase in flow.
View Complete Details

By Pass Rotameters

By-pass Rotameters are suitable for economical measurement of flow in larger pipelines generally 2" NB to 14" NB. The construction is simple and reliable consisting of orifice plate with carrier ring and a shunt Rotameter. The flow rate through the Rotameter is proportional to the pressure drop across the orifice plate created by the main flow and is calibrated accordingly. During installation care should be taken to ensure laminar flow in the pipe section. Orifice plate dimensions are based on ISA ISOBS standards. By Pass Rotameter is an inference type Flow Meter.
View Complete Details
Tell Us What are you looking for? Will call you back