Our Products
For solid density determination | |
Suitable for , AB, DAB, HPB & PGB sERIES | |
Can use for other weighing balance also | |
STANDARD ACCESSORIES | |
Beaker Base | |
Beaker | |
PAN stand | |
Pans suspension | |
Thermometer | |
Thermometer | |
Power Supply -DC7.5V According to the Archimedean Principle, Solid Body Immersed in a liquid apparently loses as much of its own weight as the weight of the liquid it has displaced.This makes it possible to determine the unknown value.Depending on whether the body in quotient is liquid or solid.The International System of units specifies Kg/m3 as the unit of density. However, the unit g/cm3 is better suited to lab purpose |
1 or 2 points auto-calibration (100% in saturated air or air-saturated water, 0% in zero oxygen solution). | |
Automatically compensates salinity and barometric pressure after manual input. | |
Selectable readout in ppm, mg/L or % saturation. | |
Selectable temperature units between degrees Celsius (C) and degrees Fahrenheit (F). | |
Automatic Temperature Compensation ensures high accuracy of measurements. | |
Automatic endpoint function freezes the stable measured values for easy reading and recording data. | |
Calibration due reminder prompts you to calibrate the meter regularly. | |
Help message as an operational guide to helps you understand how to use meter. | |
Setup menu lets user customize calibration points, resolution, stability condition of measurements, temperature units, date/time to meet personal preferences. | |
Reset function allows user to returns all settings to the factory default values. | |
Expand memory stores and recalls up to 500 readings. | |
Built-in real-time clock stamps stored data to meets GLP standards. | |
Stored data can be transferred into personal computer via USB communication interface |
During the pH mode, Up to 5 points push-button calibration with auto-buffer recognition | |
Selectable pH buffer standards and temperature units. | |
Automatically calculates and displays electrode slope after calibration. | |
During the ion mode, 2 to 5 points push-button calibration from low to high concentrations | |
Direct readout ion concentration simplifies the elaborate measurement process. | |
Automatic Temperature Compensation (ATC) ensures highly accurate measurements over the entire range. | |
Automatic endpoint function freezes the stable measured values for easy reading and recording data. | |
Calibration due reminder prompts you to calibrate the meter regularly. | |
Help message as a operational guide to helps you understand how to use meter. | |
Setup menu lets user customizes buffer standards, calibration points, stability conditions, resolution, | |
measurement units, date and time to meet measurement requirements. | |
Reset function can resumes all settings to factory default values. | |
Built-in real-time clock stamps stored data to meets GLP standards. | |
Stored data can be transferred into computer via USB communication interface. |
|
"LABMAN" - COMBINATION |
ION SELECTIVE |
ELECTRODES |
|
Electrodes |
Concentration Range ( molar) |
Limits (ppm) |
Temperature Ranget |
Main Interferences |
Calcium [ Ca++ ] |
10-1 to 5.10-7 |
4,010 to 0.02 |
5 to 50 |
Ba, Al, Sr |
Chloride [ Cl- ] |
1 to 5.10-5 |
35,500 to 1.8 |
5 to 50 |
I, Br, CN, S |
Fluoride [ F- ] |
10-' to 10-6 |
1,900 to 0.02 |
5 to 50 |
OH |
Nitrate [ NO3 ] |
1 to 7.10-6 |
62,000 to 0.4 |
5 to 50 |
CI, NO |
Bromide [ Br ] |
1 to-5.10-6 |
81,000 to 0.4 |
5 to 50 |
I, S, CN |
Sodium [Na'] |
1 to .10-5 |
23000 to 0.2 |
5 to 50 |
Li, K |
Cadmium [ Cd++ ] |
1-1 to 10-6 |
11200 to 0.1 |
5 to 50 |
Ba, Cu, Ag, Hg |
Iodide [ N ] |
1-1 to 10-5 |
127000 to 1.2 |
5 to 50 |
S, CN |