Our Products
Hematology Analyzer
2 Products availableAnalyzers And Analytical Instruments
2 Products availableLaboratory Apparatus
2 Products availableLab Instrument
2 Products availableClinical Laboratory Device
1 Products availableHardness Tester
1 Products availableMeasuring Instruments
1 Products availableWe are one of the leading manufacturers, suppliers and exporters of a range of Digital Spectrophotometers. Our product range includes four models of Digital Spectrophotometer VSI-SP1, VSI-SP2, VSI-SP3 & VSI-SP4. These products are engineered with precision to meet various requirements of different laboratories. A wide range of high qualityMore..
VSI Electronics Private Limited is an established manufacturer, supplier and exporter of Bio Nano Spectrophotometer from India. Bio Nano Spectrophotometer offered by the company are high on quality, performance and are made of the finest quality raw materials, making them durable and long lasting.
Bio-Nano Spectrophotometer (VSI-35) is new designer model, suitable for quick test of DNA, RNA and Protein, especially for small size samples. Can measure 0.53µl sample, no dilution of samples required. Quick scan 0.2 seconds only, long life lamps more than 2000 hours, Wavelength Range 200850nm, Resolution 1 nm, Detects Nucleic acid up to 23750 ng/µl, Wavelength Accuracy +/- 1nm, Absorbance range 0.02 3.00 Abs, Path length 0.5mm, Light Source: D2 & W Lamp, Software Included.
SALIENT FEATURES:
Note: Appearance & Specifications are subject to change due to continuous development.
Technical Specification Of Bio Nano Spectrophotometer
Minimum Sample Size | 0.5 µl – 2 µl (2 µl Advised) |
Path Length | 0.2mm. or 1mm. |
Light Source/Life | Xenon Flash Lamp />109 Flashes |
Detector Type | 3864 Element Liner Silicon CCD Array |
Wavelength Range | 200 – 800 nm |
Wavelength Accuracy | +/- 1 nm (TWHM at Hg 253.7nm.) |
Spectral Resolution | = 3nm (FWHM at Hg 253.7 nm.) |
Absorbance Precision | 0.003 Abs. (1mm. Path Length) |
Absorbance Accuracy | +/- 1% (7.332 Abs., at 260 nm Wavelength) |
Absorbance Range | 0.04 – 90 (at 260 nm Wavelength) 10mm equivalent |
Detection Concentration Range | 2ng/ul dsDNA ~ 4,500ng/ul dsDNA |
Detection Time | < 10 seconds |
Input Voltage | DC24V 2A |
Power | 20 W |
Size (WxDxH) | 200 x 250 x 166 mm. |
STANDARD ACCESSORIES | Micro Spectrophotometer, Setup CD, Adapter, USB Cable and Operation Manual. |
VSI Electronics Private Limited is an established manufacturer, supplier and exporter of Microprocessor UV-VIS Spectrophotometer Double Beam from India. The Microprocessor UV-VIS Spectrophotometer Double Beam offered by the company are high on quality, performance and are made of the finest quality raw materials, making them durable and long lasting.
Microprocessor UV-VIS Spectrophotometer Double Beam with eight-cell cuvette holder (VSI-501) – Automatic cell changer – 10mm path length, Range 190-1100nm, Basic/Quantative Wavelength Scan/DNA Protein Test/Kinetic, automatic peak picking & spectrum display. Large screen with graphic display. Spectrum & data can be sent to a computer via a USB port. Software Included, complete with standard accessories.
SALIENT FEATURES
Note: Appearance & Specifications are subject to change due to continuous development.
Technical Specifications Of Double Beam UV-VIS Spectrophotometer (VSI-501)
Function | Basic, Wavelength Scan, Multi Wavelength, Kinetics, Quantitative, DNA/Protein |
Wavelength Range | 190 – 1100 nm |
Spectral Bandwidth | 1.0 nm |
Optical System | Double Beam, Grating 1200 lines/mm |
Wavelength Accuracy | +/- 0.1 nm |
Wavelength Repeatability | +/- 0.1 nm. |
Scanning Speed | HI, MED & LOW. Maximum 3600 nm/min. |
Photometric Range | -0.3 to 3 A, 0 to 200 %T, 0 to 9999 C |
Photometric Accuracy | +/- 0.3 %T or + 0.002 A/h @ 1A |
Stray Light | < 0.03 %T @ 220nm & 360nm |
Stability | <0.001 A/hour @ 500nm, after warming up |
Baseline Flatness | +/- 0.001 A/h (200 - 1000 nm) |
Sample Compartment | 8 Cell with automatic cell changer - 10mm. path length |
Light Source | Halogen & Deuterium Lamps (Pre-Aligned) |
Noise | +/- 0.001A (at 500nm, after warming up) |
Detector | Dual Silicon Photodiode |
Display | 7 inches TFT Color Screen |
Key Board | Soft Touch membrane type |
Output Ports | USB Drive, USB Host & RS232 |
Power | 230V +/- 10%, 50Hz, AC |
VSI Electronics Private Limited is an established manufacturer, supplier and exporter of Atomic Absorption Spectrophotometer Double Beam from India. The Atomic Absorption Spectrophotometer Double Beam offered by the company are high on quality, performance and are made of the finest quality raw materials, making them durable and long lasting.
Atomic Absorption Spectrophotometer (Double Beam), Ebert type monochromator with 1800 lines/mm halographic grating, 0 to 2nm SBW, 190-900nm Wavelength range. Eight hollow cathode lamp turret assembly with moduled eight independent power supplies. Built-in background corrector in the system using high intensity and high speed Deuterium lamp. Automatic calibration using up to maximum 10 standards and recalibration with a single standard. Direct concentration readout using different modes (K-Factor Liner regression and Quadratic regression). Display of the signal energy in the form of BAR signal and numeric form. ABS., %TRANS & CONC. Display facility. Absorbance range from 0 to 3.0 ABS. Titanium Burner of 100mm Air-acetylene and 50mm N2O – Acetylene Flames. Corrosion resistant nebulizer with Platinum – iridium capillary, Impact bead, Supplied with computer interface software.
SALIENT FEATURES
We also offer Single Beam Atomic Absorption Spectrophotometer (VSI-2100).
Note: Appearance & Specifications are subject to change due to continuous development.
Technical Specifications Of Atomic Absorption Spectrophotometer Double Beam (VSI-2102)
Parameter | Computer Controlled, High Performance, Optically Double Beam Atomic Absorption Spectrophotometer Having Following Specifications: |
---|---|
Optics Monochromator | Real time Double Beam with Deuterium background CZ design with 330mm focal length, 1800 lines/mm grating and 185-930nm wavelength range, Automatic emission wavelength selection and peaking. Continuously variable slits with 0.2 to 2 nm spectral bandwidth. Automatic wavelength scanning. Selected wide range |
Detector | High performance multi-alkali Photo multiplier tube R928 |
Motorized Lamp Turret | Eight Lamp motorized turret with automatic lamp selection and individual lamp peaking automatically warmed up. Compatible with standard & coded hollow cathode lamps |
Background Correction | Deuterium arc Radiation ULTRA FAST-PULSE 1024 Hz background corrector wavelength correction range 185-425 nm., Corrects to 2.5 total absorbance |
Automatic Flame Control Unit | Programmable gas controller with digital display of flow, full safety interlock including built in pressure regulator on both lines, power failure protection, auto shut down of flame, burner drain, door interlock and electronic flame igniter and real time status sensing, fitted bung and pressure relief bung |
Nebulizer | Fully inert nebulizer |
Spray Chamber | PTFE spray chamber and adjustable impact bead aerosol |
Burner | Titanium burners for C2H2 – N2O & C2H2 – AIR |
Sensitivity | Greater than 0.7 Abs for 5 mg/L Copper Solution with an RSD of less than 0.5% Characteristics concentration of copper 0.030 µg/ml. |
Output Port | USB, Wi-Fi, BLUETOOTH CONNECTIVITY FOR PC/INTERNET |
Software | Windows 10 based user friendly software |
Dimension | 100x55x58 cm. (LxHxB) |
Weight | 65 Kg Unpacked |
Electrical Requirement | 220/240V AC, 50/60 Hz, 800 VA |
Hollow Cathode Lamps | 67 Element High Intensity Single Element available |
Standard Accessories | Software CD, USB Cable, Manual, 4 Cathode Lamps, Acetylene Cylinder (Optional), Regulators (Optional), Moisture Filter (Optional) |