Our Products
The 382254 are a replacement set of Test Leads for Extech's Model 382252 Earth Ground Resistance Tester Kit. The 382254 are color coded, durable test leads. Comes with a 6 month warranty. Five piece test lead set.
Features:
Compatible with 382252 - Earth Ground Resistance Tester Kit
Functions MAX / MIN / HOLD, Auto Power Off
Range 35 dB 130 dB (31.5 Hz 8 kHz)
Accuracy 1.5 dB ( under reference condition) Resolution 0.1 dB
Power 9 V Battery
Models : 920P Humidity & Temperature Meter
C / F / RH Selection MAX / MIN
Auto Power Off
Range 0% 100%
RH Accuracy +/- 3% RH (25C, 20 80% RH) +/- 3.5% RH (At Other Ranges)
Resolution 0.01C / 0.01F
Models : 961P Air Flow Anemometer
Functions m / Sec, Ft / min, Knots, Km / h, MPH, CFM, MAX / MIN / HOLD
Auto Power Off Range 1 25 m /s
Accuracy +/- (3% rdg +/- 0.2 m /s)
Resolution 0.01 m / s
Models : 930P Digital LUX Meter
Functions MAX / MIN, Backlight
Auto Power Off Range 0 200, 000 lux 0 20, 000 fc Accuracy +/- 5% rdg + 10 dgt (< 10.000 lux / fc) +/-10% rdg + 10 dgt (>10.000 lux / fc)
Resolution 0.1 lux or 0.1 fc Selection lux / fc
The MOTWANE make OIL TEST SET (MOT-OTS) are used to verify the quality of the insulation oil used for circuit breakers, transformers. The insulating oil provides the insulation under high voltage potentials. The di-electric strength of insulating oil measures the ability of the oil to withstand the electrical stresses without failures. Any severe reduction in the value of the di-electric, will no longer allow the insulating oil to perform its role & equipment is subjected to failure. We have the different models with range of output voltages from 60KV to 100 KV, as per the requirements.
Features:
Equipment with single unit compact design.
Use for measurement of di-electric strength of insulating oil used for oil circuit breakers, Transformers.
Designed to offer continuously variable output voltage, manually/auto
Different models for different outputs like 60KV, 80KV, 100KV
Fast acting over current protection for overload
Suitable for conducting tests as per IS 6792-1992
Output voltmeter is with memory effect, in case of failure of supply or tripping the voltmeter continues to show the reading at which the supply fail/tripped
It is provided with GO/NOGO gauges.