Parameters conductor Size (mm)0.4 0.5 0.63 0.9conductor Resistance (per Km in Ohms.) individual 135 8 86 6 58 4 28 2conductor Resistance Unbalance (%)individual 3 2.5 2 2 average 1.5 1 1 1 conductor Elongation (minimum %)15 15 18 18attenuation At 150 Khz (db/km) Shall Not Exceed 12 8.25 6.3 4.4insulation Solid (mdpe/hdpe)spark Test3 Kv Rms Ac, 1 Spark per 5 K.m.retraction of Insulation (shall Not Exceed) 2.5 Mm After 1 Minresistance to Compression 200 N, 12 V Dcinsulation Resistance At 500v5000 Mega Ohm Kmconstruction10/20 Pair Units & 50/100 Pair Super Units of Sizes: 10 Pair to 2400 Pairsfilling Compoundwater Resistant Compound (petro Jelly)core polyester Tapemoisture Barrier Poly Aluminiumsheath / Jacket Ldpearmouring Galvanised Steel Tapearmouring Bedding Pe Tapemutual Capacitance (nf/km)individual 52 4.5 average 52 3capacitance Unbalance (pf/km)individual 3000 Pf average 750 Pffar End Cross Talk (db) At 150 Khz, Better Than 67.8 Rms Indvl. 55 Rmsnear End Cross Talk (db) At 150 Khzbetter Than 55 Rms (individual Value)pairsfrom 5 Pairs to 2400 Pairs.