Post Buy Requirement
VT

Vantage Telecommunications

Add Review

Wires

Our product range contains a wide range of Aerial Copper Telecom Cables, Underground Copper Telecom Cables and Copper Communication Cables

Aerial Copper Telecom Cables

Copper: Annealed Electrolytic Copper Conductor with Various Diameter of 0.4 Mm to 0.9 Mm as per Iec28 and Astm B3.insulation: Conductor Insulation are Solid Hdpe / Foam Skin / Cellular Insulation as per Astm D 1248 and Bs 6234.cable Core: Two Insulated Conductors are Twisted Together to Form a Pair with Uniform Specific Lay Length . Cable is Assembled By Stranding of 10 Pairs / 20 Pairs or 25 Pairs Basic Subunit. core Wrapping: a Non Hygroscopic and Dielectric Polyester Film is Applied Helically Over the Cable Core.moisture Barrier/screen: An Aluminum Foil Coated with Co-polymer On Both Sides or One Side is Applied Longitudinally Over the Cable Core.suspension Strand: 7 Wire Suspension Strand is Made Integral Part of the Cable and a Common Sheath is Provided Over Cable Core and Suspension Strand.sheath: Black Polyethylene Sheath is Extruded Over the Screen.jelly Filled Cable Option also Available.
View Complete Details

Underground Copper Telecom Cables

Copper: Annealed Electrolytic Copper Conductor with Various Diameter Ranging from 0.4 Mm to 0.9 Mm as per Iec28 and Astm B3.insulation: Conductor Insulation are Foam Skin / Cellular / Solid Hdpe Insulation as per Astm D 1248 and Bs 6234.cable Core: Two Insulated Conductors are Twisted Together to Form a Pair with Uniform Specific Lay Length. Cable is Assembled By Stranding of 10 Pairs or 20 Pairs or 25 Pairs Basic Subunit. filling Compound: a Moisture Resistant Filling Compound is Applied to Completely Coat the Insulated Conductors and Fill the Interstices Between Pairs and Units, to Avoid the Seepage of Water from Inside the Cables.core Wrapping: a Non Hygroscopic and Dielectric Polyester Film is Applied Helically Over the Cable Core.moisture Barrier/screen: An Aluminum Foil Coated with Co-polymer On Both Sides or One Side is Applied Longitudinally Over the Cable Core.sheath: Black Polyethylene Sheath is Extruded Over the Screen. specifications: Iec 60794 for Mechanical & Environmental Testing.
View Complete Details

Copper Communication Cables

Parameters conductor Size (mm)0.4 0.5 0.63 0.9conductor Resistance (per Km in Ohms.) individual 135 8 86 6 58 4 28 2conductor Resistance Unbalance (%)individual 3 2.5 2 2 average 1.5 1 1 1 conductor Elongation (minimum %)15 15 18 18attenuation At 150 Khz (db/km) Shall Not Exceed 12 8.25 6.3 4.4insulation Solid (mdpe/hdpe)spark Test3 Kv Rms Ac, 1 Spark per 5 K.m.retraction of Insulation (shall Not Exceed) 2.5 Mm After 1 Minresistance to Compression 200 N, 12 V Dcinsulation Resistance At 500v5000 Mega Ohm Kmconstruction10/20 Pair Units & 50/100 Pair Super Units of Sizes: 10 Pair to 2400 Pairsfilling Compoundwater Resistant Compound (petro Jelly)core polyester Tapemoisture Barrier Poly Aluminiumsheath / Jacket Ldpearmouring Galvanised Steel Tapearmouring Bedding Pe Tapemutual Capacitance (nf/km)individual 52 4.5 average 52 3capacitance Unbalance (pf/km)individual 3000 Pf average 750 Pffar End Cross Talk (db) At 150 Khz, Better Than 67.8 Rms Indvl. 55 Rmsnear End Cross Talk (db) At 150 Khzbetter Than 55 Rms (individual Value)pairsfrom 5 Pairs to 2400 Pairs.
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us