Post Buy Requirement
VAIBHAV EQUIPMENT SERVICE

VAIBHAV EQUIPMENT SERVICE

gstGST : 24AIOPS8140F1Z1 Verified Add Review

Our Product / Services

  1. FINE DUST SAMPLER 6 Products available
  2. RESPIRABLE DUST SAMPLER 6 Products available
  3. COMBO DUST SAMPLER 4 Products available
  4. HIGH VOLUME AIR SAHMPLER - HVS 4 Products available
  5. Calibration Services 3 Services available
  6. HANDY SAMPLER 3 Products available
  7. STACK MONITORING KIT 3 Products available
  8. GASEOUS ATTACHMENT 3 Products available
  9. CALIBRATION KIT

    2 Products available
  10. Others Products / Services 15 Products / Services available

RESPIRABLE DUST SAMPLER

Our product range contains a wide range of Respirable Dust Sampler - VRDS 500DxNL, Respirable Dust Sampler - VRDS 500NL, Respirable Dust Sampler VRDS 500EBL, RESPIRABLE DUST SAMPLER VRDS 500ENL and RESPIRABLE DUST SAMPLER - Model No. - VRDS 500

Respirable Dust Sampler - VRDS 500DxNL

90,500 /Piece Get Latest Price
  • Type Respirable Dust Sampler, RESPIRABLE DUST SAMPLER
  • Weight 30-40kg
  • Voltage 220V
  • Condition New
  • Feature Durable, Eco Friwndly, Fine Finished, Precise Design
  • Warranty 14 MONTHS
  • Display Digital, ANALOG (OPTIONAL)
  • Flow Rate 0.5-1m3, 1-1.5m3
  • Automation Grade Fully Automatic
  • Brand Name VAIBHAV
  • Power AC
  • Flow Rate Free flow more than 1.5 m3/min without filter paper and with flow stabilization is disable. 1.0 m3/min with filter paper installed and flow stabilization controller enabled
  • Weight 45 Kg
  • Special Feature Design as per Indian standard BIS 5182(Part 23):2006, digital flow indicator & volume totalizer, waterless manometer eliminate filling of distilled water & maintaining zerolevel in glass manometer tube
  • Special Feature.. Electronic flow controller, Sampling flow will maintain the pre set level even during filter chocking, ampere and voltage variation, instrument will auto shut if flow vary from set flow & time limit.
  • Digital Manometer Digital display of manometer flow on 16 character, 2 line LCD display. Flow indication in two digit with 3 decimal places & volume tantalization indication in five digit with 2 decimal place.
  • Auto Zero of Volume By pressing single key volume will be auto zero
  • Particulate Sampling 10 micron down to 0.1 micron (depending upon type of filter used). A cyclone is used for fractionating the dust into two fractions, D-50 cutoff for the cyclone is at 10 microns.
  • Particulate Sampling.. RSPM is accumulated on the filter paper (8”X10” size) while coarse dust is collected in a cup placed under the cyclone
  • Filter Holder To accommodate any standard filter paper of 20.3cm x 25.4cm (8inchX10inch) in size, particulate bigger than 10 micron collected in separate dust cap under the cyclone
  • Filter Media 8inch X 10inch (203mm X 254mm / 20.3cm X 25.4 cm) Glass microfiber filter for common use and EPM 2000 or equivalent for special monitoring / research work
  • IS Reference Match the requirement prescribed in BIS 5182(Part-23) 2006
  • Time Recorder 0 to 99999.99 hrs. time totalizer records the running time in hours
  • Clock / Timer Programmable Real Time control system with control of automatic start & stop, number of required intervals can be programmed, Timer is used to start and shut off the sampler at preset time
  • Sampling Time 30 hours (maximum)
  • Power Requirement Single phase AC 220 volts, 50 Hz, sampler unaffected by +/- 10 % fluctuation in supply voltage. For proper operation and safety a good earth connection is mandatory
  • Dimension Approximately 410mm X 300mm X 700mm
  • Particle Size Separate provision for collection of Respirable and non Respirable (less than and greater than 10 micron) size particles
  • Construction The body of RDS is robust enough to withstand impacts and vibration in transportation, it is made of heavy aluminum sheet.
  • Night View Provision has been made for light in the sampler for taking reading during dark area and in night hours
  • Hardware Only SS corrosion free hardware used in sampler
  • Flow Control The system will automatically maintain the flow rate constant and compensate for dust load deposited on the filter.
  • Flow Control.. When dust load increases beyond the capacity of the blower the flow rate will begin to decrease and the system will automatically be shutdown if the flow rate tends to drop below 15% of pre set level
  • Suction Blower.. Dynamically balanced, Brushless, regenerative, belt less almost maintenance free & zero consumable noise less turbine blower with little noise.
  • Suction Blower.. Multi bladed impeller revolves at a very high speed in a specially designed stator cum compression chamber ensuring very fine clearance between them
  • Suction Blower... The impeller is fitted directly onto a bearing mounted shaft of a superior quality flanged electric motor. 100 % oil free required zero lubrication

special features

confirm to bis 5182 (part 23) : 2006 standard

sampling flow rate will maintain automatic at pre set level even during filter chocking, ampere& voltage variation with electronic feedback controller

digital manometer with volume totalizing (waterless manometer, no need of filling and adjustingzero lever with distilled water)

digital manometer eliminated glass manometer tube brakeage & water evaporation duringsampling

flow will be readout upto to three decimal place.

provide sample volume in at any stage of sampling on display

sturdy aluminum construction with ss hardware

little noise during operations

maintenance free brushless regenerative heavy duty induction suction assembly

totally eliminated of electromagnetic interference (emi) to tvs is totally eliminated

blower immune to voltage fluctuations thus eliminating need of voltage stabilizer

compact, portable, easy to operate-transport & handle

arrangement for parallel gaseous sampling

light provision for working in night & dark area

design to runs continuously 24 hours or more

modular design for easy operation

suitable for outdoor use, corrosion free lockable housing

.

Additional Information:

Payment Terms : L/C, D/P, T/T

Delivery Time : READY STOCK

View Complete Details

Respirable Dust Sampler - VRDS 500NL

59,000 /Piece Get Latest Price
  • Min. Order (MOQ) 1 Set(s)
  • Type Respirable Dust Sampler
  • Weight 30-40kg
  • Voltage 220V
  • Condition New
  • Power Source Electricity
  • Feature Durable, Eco Friwndly, Fast Cleaning, Fine Finished, Precise Design
  • Warranty 14 MONTH
  • Display Ananlog
  • Flow Rate 1-1.5m3
  • Automation Grade Semi Automatic
  • Brand Name Vaibhav
  • Power AC Single Phase Ac Supply
  • Airflow 0.9 to 1.4 cubic meter per minute
  • Dimension (L*B*H in mm) 410 X 300 X 700
  • Production Capacity 500 Set Per year

Special Features :

  • Brushless & belt less almost maintenance free & zero consumable noise less turbine blower,
  • Modular design for easy operation
  • Drain plug for manometer fluid leveling
  • Sturdy aluminum construction with SS hardware
  • Low Noise during operations
  • Less variation in flow even chocking of filter
  • Totally eliminated of EMI
  • Compact, Portable, Easy to Operate-Transport & Handle
  • Arrangement for Parallel Gaseous sampling
  • Light provision for working in night & dark area
  • Design to runs continuously 24 hours or more
  • Castor provide easy internal movement
  • Common Body (Housing) structure for all the model which will easy converted to any of the below model
  • Suitable for Outdoor Use, Corrosion free lockable housing

Additional Information:

Payment Terms : T/T

Packaging Details : Standard Packing in Hard Board with Armor Sheet Protection Having Bubble Roll Layer in Instrument

Delivery Time : READY STOCK

View Complete Details

Respirable Dust Sampler VRDS 500EBL

61,700 /Piece Get Latest Price
  • Min. Order (MOQ) 1 Set(s)
  • Type Respirable Dust Sampler
  • Weight 30-40kg
  • Voltage 220V
  • Condition New
  • Power Source AC
  • Feature Durable, Eco Friwndly, Fine Finished, Precise Design
  • Warranty 14 MONTHS
  • Display Digital
  • Flow Rate 0.5-1m3, 1-1.5m3
  • Automation Grade Fully Automatic
  • Brand Name VAIBHAV
  • Power AC
  • Flow Rate Free flow 0.9 – 1.4 m3/min free flow with filter and more than 2.0 m3/min without filter,
  • Weight 50 kg
  • Warranty ALL VAIBHAV PRODUCTS CARRY 14 MONTH WARRANTY
  • Basic features Brush less belt driven almost maintenance free & almost zero consumable blower, electronic digital manometer in place of glass manometer, digital flow indicator & volume totalizer (Digital Manometer),
  • Particulate Sampling 10micron down to 0.1micron(depending upon filter used) A cyclone is used for fractionating the dust into 2 fractions, D50 cutoff for cyclone is at 10microns. RSPM is accumulated on the filterpaper
  • Filter Holder To accommodate any standard filter paper of 25 x 20 cm, particulate bigger than 10 micron collected in separate dust cap under the cyclone
  • Filter Media 8” X 10” (203mm X 254mm / 20.3cm X 25.4 cm) Glass microfiber filter for common use and EPM 2000 or equivalent for special monitoring / research work
  • IS Reference Match the requirement prescribed in BIS 5182(Part-23) 2006
  • Timer Recorder 0 to 99999.99 hrs. time totalizer records the running time in hours
  • Clock / Timer Programmable Real Time control system with control of automatic start & stop, number of required intervals can be programmed, Timer is used to start and shut off the sampler at preset time
  • Sampling Time 30 hours (maximum) for single sampling
  • Power Requirement Single phase AC 220 volts, 50 Hz, sampler unaffected by +/- 10 % fluctuation in supply voltage. For proper operation and safety a good earth connection is mandatory
  • Dimension Approximately 410mm X 300mm X 700mm
  • Particle Size Separate provision for collection of Respirable and non Respirable (less than and greater than 10 micron) size particles
  • Construction The body of RDS is robust enough to withstand impacts and vibration in transportation; it is made of heavy aluminum sheet.
  • Night View Provision has been made for light in the sampler for taking reading during dark area and in night hours
  • Hardware Only SS corrosion free hardware used in sampler
  • Digital Display 16 character, 2 line LED display with 5 key operation

SPECIAL FEATURES

Digital Manometer with volume totalizing (Waterless manometer, no need of filling and adjusting zero lever with distilled water)

Provide Sample volume in m3 at any stage of sampling on display

Modular design for easy operation

Sturdy aluminum construction with SS hardware

Glass manometer tube brakeage during transportation & water evaporation is eliminated due to digital manometer

Low Noise during operations

Less variation in flow even chocking of filter

Totally eliminated of EMI

Compact, Portable, Easy to Operate-Transport & Handle

Arrangement for Parallel Gaseous sampling

Light provision for working in night & dark area

Design to runs continuously 24 hours or more

Castor provide easy internal movement

Common Body (Housing) structure for all the model which will easy converted to any of the VRDS 500series

Suitable for Outdoor Use, Corrosion free lockable housing

Additional Information:

Payment Terms : L/C, D/P

Delivery Time : READY STOCK

View Complete Details

Respirable Dust Sampler VRDS 500ENL

65,300 /Piece Get Latest Price
  • Min. Order (MOQ) 1 Set(s)
  • Type Respirable Dust Sampler
  • Weight 50 KG
  • Voltage 220V
  • Condition New
  • Feature Durable, Eco Friwndly, Fine Finished, Precise Design
  • Warranty 14 MONTHS
  • Display Digital
  • Flow Rate 0.5-1m3, 1-1.5m3
  • Automation Grade Semi Automatic
  • Brand Name VAIBHAV
  • Power AC
  • Flow Rate Free flow 0.9 – 1.4 m3/min free flow with filter and more than 2.0 m3/min without filter
  • Weight 58 Kg
  • Warranty ALL VAIBHAV PRODUCTS CARRY 14 MONTH WARRANTY
  • Basic features Brushless & belt less almost maintenance free & zero consumable noise less turbine blower, electronic manometer in place of glass manometer, digital flow indicator & volume totalizer, Digital Manomete
  • Particulate Sampling 10micron down to 0.1micron (depending upon filter used). A cyclone is used for fractionating the dust into 2 fractions, D50 cutoff for the cyclone is at 10microns. RSPM is accumulated on the filter
  • Filter Holder To accommodate any standard filter paper of 25 x 20 cm, particulate bigger than 10 micron collected in separate dust cap under the cyclone
  • Filter Media 8” X 10” (203mm X 254mm / 20.3cm X 25.4 cm) Glass microfiber filter for common use and EPM 2000 or equivalent for special monitoring / research work
  • IS Reference Match the requirement prescribed in BIS 5182(Part-23) 2006
  • Timer Recorder 0 to 99999.99 hrs. time totalizer records the running time in hours
  • Clock / Timer Programmable Real Time control system with control of automatic start & stop, number of required intervals can be programmed, Timer is used to start and shut off the sampler at preset time
  • Sampling Time 30 hours (maximum)
  • Power Requirement Single phase AC 220 volts, 50 Hz, sampler unaffected by +/- 10 % fluctuation in supply voltage. For proper operation and safety a good earth connection is mandatory
  • Dimension Approximately 410mm X 300mm X 700mm
  • Particle Size Separate provision for collection of Respirable and non Respirable (less than and greater than 10 micron) size particles
  • Construction The body of RDS is robust enough to withstand impacts and vibration in transportation; it is made of heavy aluminum sheet.
  • Night View Provision has been made for light in the sampler for taking reading during dark area and in night hours and
  • Hardware Only SS corrosion free hardware used in sampler

special features

  • digital manometer with volume totalizing (waterless manometer, no need of filling and adjusting zero lever with distilled water)
  • provide sample volume in m3 at any stage of sampling
  • modular design for easy operation
  • sturdy aluminum construction with ss hardware
  • glass manometer tube brakeage and water evaporation were eliminated due to digital manometer
  • low noise during operations
  • less variation in flow even chocking of filter
  • maintenance free noiseless suction assembly
  • totally eliminated of emi
  • compact, portable, easy to operate-transport & handle
  • arrangement for parallel gaseous sampling
  • light provision for working in night & dark area
  • design to runs continuously 24 hours or more
  • castor provide easy internal movement
  • common body (housing) structure for all the model which will easy converted to any of the vrds 500 series model
  • suitable for outdoor use, corrosion free lockable housing

Additional Information:

Payment Terms : L/C, D/P

Delivery Time : READY STOCK

View Complete Details

Respirable Dust Sampler - Model No. - VRDS 500

55,000 /Piece Get Latest Price
  • Min. Order (MOQ) 1 Set(s)
  • Type Respirable Dust Sampler
  • Weight 30-40kg
  • Voltage 220V
  • Condition New
  • Feature Durable, Eco Friwndly, Fine Finished, Precise Design
  • Warranty 14 MONTHS
  • Display Ananlog
  • Flow Rate 0.5-1m3, 1-1.5m3
  • Automation Grade Manual
  • Brand Name VAIBHAV
  • Power AC
  • Flow Rate Free flow 0.9 – 1.4 m3/min free flow with filter and more than 2.0 m3/min without filter
  • Weight 30 Kg
  • Warranty ALL VAIBHAV PRODUCTS CARRY 14 MONTH WARRANTY
  • Basic features Heavy duty brushless belt driven almost maintenance free & zero consumable blower
  • Particulate Sampling D50 cutoff cyclonic separator separate 10micron down to 0.1micron(depending upon filter). A cyclone is used for fractionating dust into two fractions. RSPM(<10μm ) are accumulate on filter paper
  • Filter Holder Fine finished power coated fabricated from aluminum casting having zero leakage / leak proof through rubber gasket at all joints to accommodate any standard filter paper of 20.3cm x 25.4cm
  • Filter Media 8” X 10” (203mm X 254mm / 20.3cm X 25.4 cm) Glass microfiber filter for common use and EPM2000 or equivalent for special monitoring / research work
  • IS Reference Match the requirement prescribed in BIS 5182(Part-23) 2006 for particulate matter collection
  • Timer Recorder 0.00 to 99999.99 hrs. time totalizer records the running time in hours
  • Clock / Timer Programmable Real Time control system with control of automatic start & stop, number of required intervals can be programmed, Timer is used to start and shut off the sampler at preset time
  • Sampling Time As per user choice and upto 30 hours maximum for single operation
  • Power Requirement Single phase AC 220 volts, 50 Hz, sampler unaffected by +/- 10 % fluctuation in supply voltage. For proper operation and safety a good earth connection is mandatory
  • Dimension Approximately 410mm X 300mm X 700mm
  • Particle Size Separate provision for collection of Respirable and non Respirable (less than and greater than 10 micron) size particles
  • Construction The body of RDS is robust enough to withstand impacts and vibration in transportation, it is made of heavy aluminum sheet.
  • Night View Provision has been made for light in the sampler for taking reading during dark area and in night hours
  • Hardware Only SS 304 corrosion free hardware are used in sampler for assembling
  • Make VAIBHAV EQUIPMENT SERVICE – AHMEDABAD

special features

modular design for easy operation

drain plug for manometer fluid leveling

sturdy aluminum construction with ss hardware

low noise during operations

less variation in flow even chocking of filter

maintenance free suction assembly

totally eliminated of emi

compact, portable, easy to operate-transport & handle

arrangement for parallel gaseous sampling

light provision for working in night & dark area

design to runs continuously 24 hours or more

common body (housing) structure for all the model which will easy converted to any of the below model

suitable for outdoor use, corrosion free lockable housing

.

Additional Information:

Payment Terms : L/C, D/P, T/T

Delivery Time : READY STOCK

View Complete Details

Respirable Dust Sampler - VRDS-500BL

57,300 /Piece Get Latest Price
  • Min. Order (MOQ) 1 Set(s)
  • Type Respirable Dust Sampler
  • Weight 30-40kg
  • Voltage 220V
  • Condition New
  • Power Source Electricity
  • Feature Durable, Eco Friwndly, Fast Cleaning, Fine Finished, Precise Design
  • Warranty 14 Month
  • Display Ananlog
  • Flow Rate 1-1.5m3
  • Automation Grade Semi Automatic
  • Brand Name Vaibhav
  • Weight 41 kg
  • Production Capacity 100 Set Per year
  • Airflow 0.9 to 1.4 cubic meter per minute
  • Dimension (L*B*H in mm) 410 X 300 X 700
  • Suitable for Outdoor Use, Corrosion Free Lockable Housing
  • Model No. VRDS 500BL

Special Features :

  • Modular design for easy operation
  • Drain plug for manometer fluid leveling
  • Sturdy aluminum construction with SS hardware
  • Low Noise during operations
  • Less variation in flow even chocking of filter
  • Maintenance free Suction assembly
  • Totally eliminated of EMI
  • Compact, Portable, Easy to Operate-Transport & Handle
  • Arrangement for Parallel Gaseous sampling
  • Light provision for working in night & dark area
  • Design to runs continuously 24 hours or more
  • Castor provide easy internal movement
  • Common Body (Housing) structure for all the model which will easy converted to any of the below model

Additional Information:

Payment Terms : L/C, T/T

Packaging Details : Standard Packing in hardboard box with Inner Armor Sheet Packing and Bubble Roll Layer On Instrument

Delivery Time : READY STOCK

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us