Post Buy Requirement
US
Pune, Maharashtra, India
Add Review

Oil Filters #704543

Oil Filtration Plant

OIL FILTRATION PLANTS CAN BE SUCCESSFULLY MODIFIED & AUTOMATED FOR VARIABLE FLOW RATE.
A brief description is given for your reference.
INLET & OUTLET PUMPS :
The pump will be driven by suitable sized AC drive to control the flow rate. By using these settings we can control the flow rate from i.e. If Plant is 6000 LPH then it will vary from 1000 LPH to 6000 LPH.
HEATER TANK :
It is also necessary to select proper heat output for variable flow rates. This will avoid localized heating of oil for small flow rates.
This section will incorporate PLC which will control the heaters.
PLC will be used for control of heater groups, once certain flow rate has been selected, heaters will be configured automatically to suit that flow rate.
This control panel will be designed for reliable & trouble free operation.
By using the above system the major benefit is to have a single machine instead of different models for different capacities.
In this case, flow rate can be kept variable from 1000 LPH to 6000 LPH. Power saving of 30% can be achievable by using this system as compared with traditional oil filter system designs.
OPERATIONAL & PROCESS AUTOMATION
Press'START'to start the oil filtration process.
All airing valves, oil inlet & outlet valve will close.
The rotary vacuum pump will start to achieve coarse vacuum.
After achieving coarse vacuum level, which the'Vacuum Switch'will sense.
After achieve the desired level of fine vacuum in the plant, oil inlet valve & intermediate valve will open and the oil inflow will start due to vacuum inside the plant. The flow switch provided in the suction line of the plant will sense the oil flow & that signal will start the oil inlet pump. In case, the incoming oil flow is not there, HMI on the control panel will display'LOSS OF OIL', with annunciation. One pressure release valve, provided across the inlet pump will control the excessive pressure rise in the plant.
As oil is filled in the degassing chamber, the high level float switch will operate & that will put'OFF'the inlet pump & start the outlet pump. The starting signal to the outlet pump will open the outlet valve. As the oil level in the degassing chamber comes down, the high level float switch will start the inlet pump, again. Thus the oil circulation through the filtration plant will start.
After the continuous oil flow through the plant, the heaters will be'ON'.
Temperature of oil will be controlled by TIC (Temperature Indicating Controller) & one safety thermostat will control the accidental temperature rise.
Thus the hot oil circulation through filters & degassing chamber will start resulting in the effective separation of solid impurities as well as dissolved moisture & gases from the oil.
During the filtration process, the necessary interlocks provided will avoid malfunctioning of the plant, like
1. High level float switch will stop the inlet pump, to avoid flooding of the degassing chamber.
2. Unless the inlet pump is'ON'the heaters will not be energized.
3. Low level float switch will stop the outlet pump to avoid dry running of the pump
During the filtration process, the moisture meter, installed in the inlet line, will display the moisture content in PPM, continuously, on it's indicator, on the control panel.
Once the desired PPM(moisture)content is achieved, the moisture meter installed in the inlet line, will shut down the plant, automatically.
This plant will also run with Manual Interference means with Manual Operation.
View Complete Details

Transformer Oil Filtration Plant

Our oil filtration plants are used to remove impurities from transformer and switchgear oil such as moisture, dirt, air and other gases. This is a `low temperature and high vacuum` principle based equipment as per the International Standards 6034 (1989) and its latest revision. We manufacture plants of variable capacities of 1200 to 25, 000 lph which can be customized to special capacities if required by the clients. This plant takes the impure oil into the system through the inlet ball valve and then pumps it through by a positive displacement pump. A filter prior to this removes solid particles up to 1mm size and magnetic particles. After heating the oil up to 60c it passes through the cartridge filters, where particles up to 5 microns are filtered. A specially designed vacuum chamber removes moisture, air and all the gases with the help of vacuum. The oil falls by way of gravity over the media inside forming a thin film of oil, exposing a larger surface area. The dissolved moisture and gases are evacuated and the oil is ready.

High-Vacuum Transformer Oil Filtration and Dehydration Plants
Our Oil Filtration Plants are used to remove impurities from transformer and switchgear oil such as moisture, dirt, air and other dissolved gases. This is a `Low Temperature and High Vacuum` principle based equipment as per the International Standards 6034 (1989) and its latest revision. We manufacture plants of variable capacities of 600 to 25000 LPH which can be customized to special capacities if required by the clients. This plant takes the impure oil into the system through the inlet ball valve and then pumps it through by a positive displacement pump. A filter prior to this removes solid particles up to 1mm size and magnetic particles. After heating the oil up to 60C t passes through the cartridge filters, where particles up to 5 microns are filtered. A specially designed vacuum chamber removes moisture, air and all the gases with the help of vacuum. The oil falls by way of gravity over the media inside forming a thin film of oil, exposing a larger surface area. The dissolved moisture and gases are evacuated and the oil is ready.
Transformer Oil Filtration and Dehydration Plants / Purifiers are available for
Transformer and Capacitor Manufacturers Skid mounted plants for preparation of new oils prior to apparatus filling and impregnation.
Transformer Repairers - Complete plants for preparation of new oils and regeneration of used oils for reuse. We can provide the purification system you need as well as vacuum storage tanks and transformer filling and emptying / pumping station.
Transformer Owners - Portable plants are available in a variety of trailer-types and sizes to allow on-site servicing of transformer oil right in the substation. Trailers are available with a wide variety of options including laboratory space, oil-testing equipment. Plants are designed for drying out of the transformer insulation and oil filling and impregnation under vacuum. Hot oil circulation and hot oil spray methods can also be used.
The filtration plant will be designed for high vacuum & low temperature of oil for achieving required results.
The plant will be Mobile, to be mounted on your Vehicle or Skid Mounted, with or without enclosure, suitable for outdoor or indoor use.All components will have adequate strength & rigidity to withstand normal conditions of handling & transport.
The plant will consist of the following :
Inlet Pump
A 600 to 25000 LPH capacity positive displacement gear type pump will be provided. The pump will be suitable for vacuum & continuous trouble free operation. A pressure release valve will be provided across the gear pump, to control the accidental pressure rise in the plant.
Capacity 600 to 25000 LPH
Operating Pressure - 2 Bar
Suction - 4-5 mtrs
By pass arrangement will be provided in between Inlet & Outlet
Heaters
Nicrome or Kanthal wire heater elements inserted in refractory formers will be provided in protection tubes to avoid localized overheating, hot spot formation & breaking of oil. Heaters will be capable of heating oil from 200 C. to 600 C., as recommended in IS 6034 1989. Total heater power will be 9 to 248 kW divided into two/three groups. Each group of heaters will be controlled by TIC. An additional thermostat will be provided as a safety to control the temperature during accidental temperature rise.The surface density of the heater pipes will not be more than 2.5 watts/cm2.A drain valve for the heater tank will be provided.
Indirect type, Wound elements placed in ceramic formers located in Protection Tubes.
Heater Power :9 to 248 KW.
A Pressure Safety Valve & a Drain Valve will be provided.
A Control Thermostat and a Safety Thermostat will be provided.
Filtration System
Filtration system will consist of the following,
A Preliminary filter
This filter will be provided to prevent any damage to inlet pump by straining magnetic & all other particles above 1mm size. The cleaning of the filter is possible without dismantling the filter from the pipeline.
Cleanable without dismantling
Flow capacity 600 to 25000 LPH
Rating - 50 mm
Arrests magnetic particles
B Pre-Filter
Filters will be easily changeable. It will be suitable for removal of particles larger than 20 microns. It will be suitable for removal of sludge content in the used oil. This will enhance the life of fine filter.
C Cartridge Filter (fine filter)
Throw away type, non-hygroscopic cartridge filter elements of one-micron rating will be provided. The cartridges are easy for replacement & have large dust holding capacity.
Cartridge Filter (fine) placed in a steel housing.
Flow capacity 600 to 25000 LPH
Rating - 1 Micron
Ionic Reaction Column
An Ionic Reaction Column of 10 to 40 Kg activated alumina will be provided for reduce the acidity in the oil. A bypass arrangement will be provide for after first filling with IRC.
Degassing Chamber (Single Stage as well as Two Stage)
It will be of M.S. welded construction. The chamber will be designed to withstand the suitable vacuum. In the degassing chamber, dissolved gases & moisture from the oil will be removed. A specially designed media will be provided in the degassing chamber to offer maximum surface area, to form a thin film of oil, to achieve maximum possible removal of dissolved gases & moisture at the rated flow rate. One high level & one low level float switch will be provided to control the oil level in the degassing chamber.
Two stages will be separated by a siphon seal.
Highly efficient Two Stage degasser packed with Raschig Rings & equipped with the following :
Totally Welded
Sight Glass & Lamp Shade
Raschig Ring Trays
Low Level and High Level Float Switches
Level Sensor will provided in Degassing Chamber
Outlet Pump
A centrifugal pump will be provided at the outlet. The capacity of the pump will be 12000 LPH and it will be suitable for sucking oil from degassing chamber, held under vacuum.
Capacity - 12000 LPH.
Discharge Head - 8 Mtrs
Vacuum Pumping System
A combination of roots & rotary vacuum pumps will be provided for evacuation of degassing chamber.
An additional connection with an isolation valve will be provided in the system, to facilitate evacuation of transformer tank, simultaneously.The vacuum pumping system will be equipped with all-necessary accessories like Vapour trap, condenser, valves & gauges etc.The specifications of the vacuum pumps will be as follows:
Rotary Oil Sealed Pump
Pumping speed (Minimum)
Ultimate vacuum
Make Indo Vacuum/Dicon/Tuthill/Leybold/Woo Sung/ Shinko Seiki/Reputed
Mechanical Booster (Roots) Pump
Pumping speed (Minimum)
Ultimate vacuum
Make Indo Vacuum/Dicon/Tuthill/Leybold/Woo Sung/ Shinko Seiki/Reputed
The Vacuum System will be equipped with the following :
Vacuum Gauge (Bourdon Type), Range: 0 to -760 mm of Hg
Vacuum Gauge (Digital Type), Range: 1 Torr
Airing Valve
Non return Valve
Cooling System
For cooling, a condenser will be provided in the vacuum line. A condenser will be provided, to maintain ambient temperature of the water which will be circulated through this condenser for collecting water in to the trap. One water tank will be provided in to the top of the mobile van having capacity to hold 100 liter water.
Non Return Valve
One non return valve will be provided at the inlet and one at the outlet, which will prevent mixing of filtered & unfiltered oil, in case of power failure.
Valve & Piping
Two airing valves will be provided for airing the vacuum system. All inline valves will be Ball Valve in case of Fully Automatic System then Valves will Solenoid Valves with carbon steel body & S.S. ball, suitable for vacuum application.
Oil & Vacuum Valves will be of Solenoid type or Ball Valve.
Piping will be of Normal Steel.
Mechanical Non Return Valves before Degassing Column & at Plant outlet
Oil Sampling Valve
Isolation Valve at Plant Inlet & Outlet
Onepressure gaugeat the inlet of the cartridge filter will be provided. One bourdon typevacuum gauge& onedigital gauge(for measurement of fine vacuum) will be provided in the vacuum system.Independent electric drives will be provided for all pumps. Motors will confirm generally to is 325 (testing) & will be of CGL / Hindustan Motors / Siemens or any other reputed make. Starters will be of direct on line type.
Control Panel
The enclosure will be fabricated out of CRCA sheets & will be suitably coated to protect from weather. All electrical control gears, mains isolating arrangement, starters, contactors, pilot lamps, push buttons, HRC fuses, relays, indicating lamps and interlocking arrangements will be housed in the enclosure. All wiring will be neatly routed & all wire terminations will be suitably identified with ferrules.A tube light will be provided for plant illumination. The plant will be suitable for operation on 415 V, 3 Phase, 50 Hz. A.C. supply.
Incoming Power Supply Cable for Control Panel is to be arranged by the Customer and is not included in scope of our supply.
Electrical Interlocks
The inlet pump will be interlocked with the heaters, in such a way that unless the oil is actually flowing in the system, the heaters cannot be energized. The electrical interlock between heater supply and motor supply will also be provided so that as soon as the inlet motor trip due to some fault in the drive/due to supply failure, the heater supply will also be automatically cut off.
In case of power failures, electro magnetically operated inlet and outlet solenoid valves will be closed and prevent oil from entering the degassing chamber. The moment oil inlet pump or discharge pump is switched on the corresponding valves will open automatically.
The suction pump and the level controller in the degassing chamber will be interlocked in such a way that when the oil/foam level in the degassing chamber increases beyond the desired level, the suction pump will be automatically cut off so that there is no further flow of oil in the degassing chamber.
The temperature indicator of digital type, together with thermostat provided will automatically switch on/off the heater elements in groups so that temperature of the oil during treatment will not be permitted to rise above the pre-set value.
A pre-set safety thermostat provided on the heater vessel will switch off all the heaters in case of any accidental temperature rise of the oil above safe temperature levels so that any likelihood of fire hazard is fully eliminated.
The inlet gear pump will be provided with built in relief valve to take care of accidental pressure increase at the outlet side of the gear pump.
An external relief valve will be provided on the heater vessel to take care of any accidental pressure rise above the safe level in the heater vessel.
Oil Hoses
Two numbers Nitrile Rubber Hoses each 10 to 15 Meters long with quick connect coupling end connection on both sides shall be provided. One is for inlet & one for outlet. Oil Hoses will be capable of handling the transformer oil at 135oC (max.) and hoses will be will be suitable for full vacuum operating conditions.
Lifting Hook
Lifting Hooks for Plant will be provided to facilitate ease of Plant Loading and unloading.
On Line Moisture Meter (As per clients requirement)
A panel mounted Digital Moisture (PPM) Meter will be provided in the outlet line to measure the moisture content in the oil.
Oil Flow Meter with Totalizer (As per clients requirement)
A panel mounted digital oil flow meter of Vatturkar / Inconel / reputed make will be provided in the outlet line to measure the oil flows.
Sleeping Arrangement (As per clients requirement)
A frame mounting arrangement for sleeping purpose of the operator will be provided in the mobile van on top of the heater tank. The bed will make from foam sheet and Rexene cover. Cooling fan will be provided in the rest room. Two persons easily sleep in to the rest bed.
Platform for Bike (As per clients requirement)
The platform will be provided for hanging bike in to the mobile van. The arrangement will be making as per your requirement and it will easy to handle in all situations.
Painting
A suitable anti rust primer will be applied on the interior and exterior surface of all steel parts, which shall followed by application of two coats of suitable durable paints to serve as base and binder for the finished coat. Under body of carriage will be painted with special black anti rust paint
Inspection Testing & Commissioning
Inspection & Testing of Transformer Oil Filtration Plant will be carried out by Consignee before dispatch.Commissioning will be done at site; our Engineer will be available on schedule date mutually decided by both parties.Our one person will be provided at your site to train and educate the operators for the period of one month. Site expenditure of the person will be at your scope.
Drawings & Manuals
One set of Schematic drawings & Guaranteed Technical Particulars of the Transformer Oil Filtration Plant will be provide with the offer and detail drawing with general arrangement of Filtration Plant, Electrical Wiring Diagram and User Manual will be provided at the time of supply.
Performance Guarantee
We give guarantee for performance of the Plant for a period of 12 months from the date of commissioning of the Plant or 18 months from the date of dispatch, whichever is earlier. During guarantee period we undertake upon written request of the purchaser to repair or replace at our discretion & as soon as possible any parts of goods delivered which can be proved to be damaged or unfit due to bad material, faulty design or poor workmanship. This guarantee does not cover damages resulting out of normal wear & tear, improper maintenance, failure to observe the operating instructions, incorrect operation, excessive loading, the use of unsuitable material, & other reasons beyond our control. This guarantee does not cover Consumables, Rubber Parts (including Oil/Vacuum Hoses) & Electrical Components-Motors.

View Complete Details

Mobile Transformer Oil Filtration Plant

During its operation of generating, transmitting and distributing power transformers give out heat which is absorbed by insulating oils. This oil has a tendency to absorb moisture from windings which leads to gradual deterioration of dielectric strength. Our filtration systems provide economical and efficient methods of purifying this lubricant. The unit consists of:

Filter Unit,

Indirect system of Oil Heating,

Vacuum Dehydration / degasification Unit

Condenser and condensate receiver

Feed and delivery pump

Piping & Valves

Control Panel

Components of Plant:

The filter unit is a coarse strainer with a wire mesh filter element for retaining solid particles and a powerful magnet for retaining magnetic particles. It has round filter paper discs held under spring compression. Specially designed heaters with low watt density heat the auxiliary heating oil, which in turn heats the transformer oil maintaining a temperature of 70-80 C. The cylindrical external pressure vessel is fitted with various shallow drip trays and a specially designed spray pipe to increase surface area. The vapor from dehydration chamber is condensed in a condensate receiver of welded M. S. construction. There are feed and delivery pump of rotary gear type coupled directly with motors. Water Separator Collect the water produced. A centralized control panel has indicators for all electrical devices.

Imported thermostat

Thermometer for measuring temperature

Pressure & Vacuum gauges

Flow control indicator

lectronic Float Control

Electrical instruments, voltometers and ammeters

Electrical overloads and overload releases for safety of motors.

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

Retailer of Oil Filters from Pune, Maharashtra by U. S. a Vaccum Technologies
Post Buy Requirement
US

U. S. a Vaccum Technologies

Add Review

Our Products

  1. Oil Filters 3 Products available
  2. Filters

    2 Products available
  3. Test Kits

    2 Products available
  4. Drying Ovens

    2 Products available
  5. Machines And Equipments

    1 Products available
  6. Hose Pipes

    1 Products available
  7. Autoclaves

    1 Products available
  8. Fashion Jewelry

    1 Products available
  9. Others Products 1 Products available

Oil Filters

Our product range contains a wide range of Oil Filtration Plant, Transformer Oil Filtration Plant and mobile transformer oil filtration plant

Oil Filtration Plant

OIL FILTRATION PLANTS CAN BE SUCCESSFULLY MODIFIED & AUTOMATED FOR VARIABLE FLOW RATE.
A brief description is given for your reference.
INLET & OUTLET PUMPS :
The pump will be driven by suitable sized AC drive to control the flow rate. By using these settings we can control the flow rate from i.e. If Plant is 6000 LPH then it will vary from 1000 LPH to 6000 LPH.
HEATER TANK :
It is also necessary to select proper heat output for variable flow rates. This will avoid localized heating of oil for small flow rates.
This section will incorporate PLC which will control the heaters.
PLC will be used for control of heater groups, once certain flow rate has been selected, heaters will be configured automatically to suit that flow rate.
This control panel will be designed for reliable & trouble free operation.
By using the above system the major benefit is to have a single machine instead of different models for different capacities.
In this case, flow rate can be kept variable from 1000 LPH to 6000 LPH. Power saving of 30% can be achievable by using this system as compared with traditional oil filter system designs.
OPERATIONAL & PROCESS AUTOMATION
Press'START'to start the oil filtration process.
All airing valves, oil inlet & outlet valve will close.
The rotary vacuum pump will start to achieve coarse vacuum.
After achieving coarse vacuum level, which the'Vacuum Switch'will sense.
After achieve the desired level of fine vacuum in the plant, oil inlet valve & intermediate valve will open and the oil inflow will start due to vacuum inside the plant. The flow switch provided in the suction line of the plant will sense the oil flow & that signal will start the oil inlet pump. In case, the incoming oil flow is not there, HMI on the control panel will display'LOSS OF OIL', with annunciation. One pressure release valve, provided across the inlet pump will control the excessive pressure rise in the plant.
As oil is filled in the degassing chamber, the high level float switch will operate & that will put'OFF'the inlet pump & start the outlet pump. The starting signal to the outlet pump will open the outlet valve. As the oil level in the degassing chamber comes down, the high level float switch will start the inlet pump, again. Thus the oil circulation through the filtration plant will start.
After the continuous oil flow through the plant, the heaters will be'ON'.
Temperature of oil will be controlled by TIC (Temperature Indicating Controller) & one safety thermostat will control the accidental temperature rise.
Thus the hot oil circulation through filters & degassing chamber will start resulting in the effective separation of solid impurities as well as dissolved moisture & gases from the oil.
During the filtration process, the necessary interlocks provided will avoid malfunctioning of the plant, like
1. High level float switch will stop the inlet pump, to avoid flooding of the degassing chamber.
2. Unless the inlet pump is'ON'the heaters will not be energized.
3. Low level float switch will stop the outlet pump to avoid dry running of the pump
During the filtration process, the moisture meter, installed in the inlet line, will display the moisture content in PPM, continuously, on it's indicator, on the control panel.
Once the desired PPM(moisture)content is achieved, the moisture meter installed in the inlet line, will shut down the plant, automatically.
This plant will also run with Manual Interference means with Manual Operation.
View Complete Details

Transformer Oil Filtration Plant

Our oil filtration plants are used to remove impurities from transformer and switchgear oil such as moisture, dirt, air and other gases. This is a `low temperature and high vacuum` principle based equipment as per the International Standards 6034 (1989) and its latest revision. We manufacture plants of variable capacities of 1200 to 25, 000 lph which can be customized to special capacities if required by the clients. This plant takes the impure oil into the system through the inlet ball valve and then pumps it through by a positive displacement pump. A filter prior to this removes solid particles up to 1mm size and magnetic particles. After heating the oil up to 60c it passes through the cartridge filters, where particles up to 5 microns are filtered. A specially designed vacuum chamber removes moisture, air and all the gases with the help of vacuum. The oil falls by way of gravity over the media inside forming a thin film of oil, exposing a larger surface area. The dissolved moisture and gases are evacuated and the oil is ready.

High-Vacuum Transformer Oil Filtration and Dehydration Plants
Our Oil Filtration Plants are used to remove impurities from transformer and switchgear oil such as moisture, dirt, air and other dissolved gases. This is a `Low Temperature and High Vacuum` principle based equipment as per the International Standards 6034 (1989) and its latest revision. We manufacture plants of variable capacities of 600 to 25000 LPH which can be customized to special capacities if required by the clients. This plant takes the impure oil into the system through the inlet ball valve and then pumps it through by a positive displacement pump. A filter prior to this removes solid particles up to 1mm size and magnetic particles. After heating the oil up to 60C t passes through the cartridge filters, where particles up to 5 microns are filtered. A specially designed vacuum chamber removes moisture, air and all the gases with the help of vacuum. The oil falls by way of gravity over the media inside forming a thin film of oil, exposing a larger surface area. The dissolved moisture and gases are evacuated and the oil is ready.
Transformer Oil Filtration and Dehydration Plants / Purifiers are available for
Transformer and Capacitor Manufacturers Skid mounted plants for preparation of new oils prior to apparatus filling and impregnation.
Transformer Repairers - Complete plants for preparation of new oils and regeneration of used oils for reuse. We can provide the purification system you need as well as vacuum storage tanks and transformer filling and emptying / pumping station.
Transformer Owners - Portable plants are available in a variety of trailer-types and sizes to allow on-site servicing of transformer oil right in the substation. Trailers are available with a wide variety of options including laboratory space, oil-testing equipment. Plants are designed for drying out of the transformer insulation and oil filling and impregnation under vacuum. Hot oil circulation and hot oil spray methods can also be used.
The filtration plant will be designed for high vacuum & low temperature of oil for achieving required results.
The plant will be Mobile, to be mounted on your Vehicle or Skid Mounted, with or without enclosure, suitable for outdoor or indoor use.All components will have adequate strength & rigidity to withstand normal conditions of handling & transport.
The plant will consist of the following :
Inlet Pump
A 600 to 25000 LPH capacity positive displacement gear type pump will be provided. The pump will be suitable for vacuum & continuous trouble free operation. A pressure release valve will be provided across the gear pump, to control the accidental pressure rise in the plant.
Capacity 600 to 25000 LPH
Operating Pressure - 2 Bar
Suction - 4-5 mtrs
By pass arrangement will be provided in between Inlet & Outlet
Heaters
Nicrome or Kanthal wire heater elements inserted in refractory formers will be provided in protection tubes to avoid localized overheating, hot spot formation & breaking of oil. Heaters will be capable of heating oil from 200 C. to 600 C., as recommended in IS 6034 1989. Total heater power will be 9 to 248 kW divided into two/three groups. Each group of heaters will be controlled by TIC. An additional thermostat will be provided as a safety to control the temperature during accidental temperature rise.The surface density of the heater pipes will not be more than 2.5 watts/cm2.A drain valve for the heater tank will be provided.
Indirect type, Wound elements placed in ceramic formers located in Protection Tubes.
Heater Power :9 to 248 KW.
A Pressure Safety Valve & a Drain Valve will be provided.
A Control Thermostat and a Safety Thermostat will be provided.
Filtration System
Filtration system will consist of the following,
A Preliminary filter
This filter will be provided to prevent any damage to inlet pump by straining magnetic & all other particles above 1mm size. The cleaning of the filter is possible without dismantling the filter from the pipeline.
Cleanable without dismantling
Flow capacity 600 to 25000 LPH
Rating - 50 mm
Arrests magnetic particles
B Pre-Filter
Filters will be easily changeable. It will be suitable for removal of particles larger than 20 microns. It will be suitable for removal of sludge content in the used oil. This will enhance the life of fine filter.
C Cartridge Filter (fine filter)
Throw away type, non-hygroscopic cartridge filter elements of one-micron rating will be provided. The cartridges are easy for replacement & have large dust holding capacity.
Cartridge Filter (fine) placed in a steel housing.
Flow capacity 600 to 25000 LPH
Rating - 1 Micron
Ionic Reaction Column
An Ionic Reaction Column of 10 to 40 Kg activated alumina will be provided for reduce the acidity in the oil. A bypass arrangement will be provide for after first filling with IRC.
Degassing Chamber (Single Stage as well as Two Stage)
It will be of M.S. welded construction. The chamber will be designed to withstand the suitable vacuum. In the degassing chamber, dissolved gases & moisture from the oil will be removed. A specially designed media will be provided in the degassing chamber to offer maximum surface area, to form a thin film of oil, to achieve maximum possible removal of dissolved gases & moisture at the rated flow rate. One high level & one low level float switch will be provided to control the oil level in the degassing chamber.
Two stages will be separated by a siphon seal.
Highly efficient Two Stage degasser packed with Raschig Rings & equipped with the following :
Totally Welded
Sight Glass & Lamp Shade
Raschig Ring Trays
Low Level and High Level Float Switches
Level Sensor will provided in Degassing Chamber
Outlet Pump
A centrifugal pump will be provided at the outlet. The capacity of the pump will be 12000 LPH and it will be suitable for sucking oil from degassing chamber, held under vacuum.
Capacity - 12000 LPH.
Discharge Head - 8 Mtrs
Vacuum Pumping System
A combination of roots & rotary vacuum pumps will be provided for evacuation of degassing chamber.
An additional connection with an isolation valve will be provided in the system, to facilitate evacuation of transformer tank, simultaneously.The vacuum pumping system will be equipped with all-necessary accessories like Vapour trap, condenser, valves & gauges etc.The specifications of the vacuum pumps will be as follows:
Rotary Oil Sealed Pump
Pumping speed (Minimum)
Ultimate vacuum
Make Indo Vacuum/Dicon/Tuthill/Leybold/Woo Sung/ Shinko Seiki/Reputed
Mechanical Booster (Roots) Pump
Pumping speed (Minimum)
Ultimate vacuum
Make Indo Vacuum/Dicon/Tuthill/Leybold/Woo Sung/ Shinko Seiki/Reputed
The Vacuum System will be equipped with the following :
Vacuum Gauge (Bourdon Type), Range: 0 to -760 mm of Hg
Vacuum Gauge (Digital Type), Range: 1 Torr
Airing Valve
Non return Valve
Cooling System
For cooling, a condenser will be provided in the vacuum line. A condenser will be provided, to maintain ambient temperature of the water which will be circulated through this condenser for collecting water in to the trap. One water tank will be provided in to the top of the mobile van having capacity to hold 100 liter water.
Non Return Valve
One non return valve will be provided at the inlet and one at the outlet, which will prevent mixing of filtered & unfiltered oil, in case of power failure.
Valve & Piping
Two airing valves will be provided for airing the vacuum system. All inline valves will be Ball Valve in case of Fully Automatic System then Valves will Solenoid Valves with carbon steel body & S.S. ball, suitable for vacuum application.
Oil & Vacuum Valves will be of Solenoid type or Ball Valve.
Piping will be of Normal Steel.
Mechanical Non Return Valves before Degassing Column & at Plant outlet
Oil Sampling Valve
Isolation Valve at Plant Inlet & Outlet
Onepressure gaugeat the inlet of the cartridge filter will be provided. One bourdon typevacuum gauge& onedigital gauge(for measurement of fine vacuum) will be provided in the vacuum system.Independent electric drives will be provided for all pumps. Motors will confirm generally to is 325 (testing) & will be of CGL / Hindustan Motors / Siemens or any other reputed make. Starters will be of direct on line type.
Control Panel
The enclosure will be fabricated out of CRCA sheets & will be suitably coated to protect from weather. All electrical control gears, mains isolating arrangement, starters, contactors, pilot lamps, push buttons, HRC fuses, relays, indicating lamps and interlocking arrangements will be housed in the enclosure. All wiring will be neatly routed & all wire terminations will be suitably identified with ferrules.A tube light will be provided for plant illumination. The plant will be suitable for operation on 415 V, 3 Phase, 50 Hz. A.C. supply.
Incoming Power Supply Cable for Control Panel is to be arranged by the Customer and is not included in scope of our supply.
Electrical Interlocks
The inlet pump will be interlocked with the heaters, in such a way that unless the oil is actually flowing in the system, the heaters cannot be energized. The electrical interlock between heater supply and motor supply will also be provided so that as soon as the inlet motor trip due to some fault in the drive/due to supply failure, the heater supply will also be automatically cut off.
In case of power failures, electro magnetically operated inlet and outlet solenoid valves will be closed and prevent oil from entering the degassing chamber. The moment oil inlet pump or discharge pump is switched on the corresponding valves will open automatically.
The suction pump and the level controller in the degassing chamber will be interlocked in such a way that when the oil/foam level in the degassing chamber increases beyond the desired level, the suction pump will be automatically cut off so that there is no further flow of oil in the degassing chamber.
The temperature indicator of digital type, together with thermostat provided will automatically switch on/off the heater elements in groups so that temperature of the oil during treatment will not be permitted to rise above the pre-set value.
A pre-set safety thermostat provided on the heater vessel will switch off all the heaters in case of any accidental temperature rise of the oil above safe temperature levels so that any likelihood of fire hazard is fully eliminated.
The inlet gear pump will be provided with built in relief valve to take care of accidental pressure increase at the outlet side of the gear pump.
An external relief valve will be provided on the heater vessel to take care of any accidental pressure rise above the safe level in the heater vessel.
Oil Hoses
Two numbers Nitrile Rubber Hoses each 10 to 15 Meters long with quick connect coupling end connection on both sides shall be provided. One is for inlet & one for outlet. Oil Hoses will be capable of handling the transformer oil at 135oC (max.) and hoses will be will be suitable for full vacuum operating conditions.
Lifting Hook
Lifting Hooks for Plant will be provided to facilitate ease of Plant Loading and unloading.
On Line Moisture Meter (As per clients requirement)
A panel mounted Digital Moisture (PPM) Meter will be provided in the outlet line to measure the moisture content in the oil.
Oil Flow Meter with Totalizer (As per clients requirement)
A panel mounted digital oil flow meter of Vatturkar / Inconel / reputed make will be provided in the outlet line to measure the oil flows.
Sleeping Arrangement (As per clients requirement)
A frame mounting arrangement for sleeping purpose of the operator will be provided in the mobile van on top of the heater tank. The bed will make from foam sheet and Rexene cover. Cooling fan will be provided in the rest room. Two persons easily sleep in to the rest bed.
Platform for Bike (As per clients requirement)
The platform will be provided for hanging bike in to the mobile van. The arrangement will be making as per your requirement and it will easy to handle in all situations.
Painting
A suitable anti rust primer will be applied on the interior and exterior surface of all steel parts, which shall followed by application of two coats of suitable durable paints to serve as base and binder for the finished coat. Under body of carriage will be painted with special black anti rust paint
Inspection Testing & Commissioning
Inspection & Testing of Transformer Oil Filtration Plant will be carried out by Consignee before dispatch.Commissioning will be done at site; our Engineer will be available on schedule date mutually decided by both parties.Our one person will be provided at your site to train and educate the operators for the period of one month. Site expenditure of the person will be at your scope.
Drawings & Manuals
One set of Schematic drawings & Guaranteed Technical Particulars of the Transformer Oil Filtration Plant will be provide with the offer and detail drawing with general arrangement of Filtration Plant, Electrical Wiring Diagram and User Manual will be provided at the time of supply.
Performance Guarantee
We give guarantee for performance of the Plant for a period of 12 months from the date of commissioning of the Plant or 18 months from the date of dispatch, whichever is earlier. During guarantee period we undertake upon written request of the purchaser to repair or replace at our discretion & as soon as possible any parts of goods delivered which can be proved to be damaged or unfit due to bad material, faulty design or poor workmanship. This guarantee does not cover damages resulting out of normal wear & tear, improper maintenance, failure to observe the operating instructions, incorrect operation, excessive loading, the use of unsuitable material, & other reasons beyond our control. This guarantee does not cover Consumables, Rubber Parts (including Oil/Vacuum Hoses) & Electrical Components-Motors.

View Complete Details

Mobile Transformer Oil Filtration Plant

During its operation of generating, transmitting and distributing power transformers give out heat which is absorbed by insulating oils. This oil has a tendency to absorb moisture from windings which leads to gradual deterioration of dielectric strength. Our filtration systems provide economical and efficient methods of purifying this lubricant. The unit consists of:

Filter Unit,

Indirect system of Oil Heating,

Vacuum Dehydration / degasification Unit

Condenser and condensate receiver

Feed and delivery pump

Piping & Valves

Control Panel

Components of Plant:

The filter unit is a coarse strainer with a wire mesh filter element for retaining solid particles and a powerful magnet for retaining magnetic particles. It has round filter paper discs held under spring compression. Specially designed heaters with low watt density heat the auxiliary heating oil, which in turn heats the transformer oil maintaining a temperature of 70-80 C. The cylindrical external pressure vessel is fitted with various shallow drip trays and a specially designed spray pipe to increase surface area. The vapor from dehydration chamber is condensed in a condensate receiver of welded M. S. construction. There are feed and delivery pump of rotary gear type coupled directly with motors. Water Separator Collect the water produced. A centralized control panel has indicators for all electrical devices.

Imported thermostat

Thermometer for measuring temperature

Pressure & Vacuum gauges

Flow control indicator

lectronic Float Control

Electrical instruments, voltometers and ammeters

Electrical overloads and overload releases for safety of motors.

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us