Post Buy Requirement

Our Products

  1. ANALOG AND DIGITAL LAB 62 Products available
  2. ITI EQUIPMENTS 18 Products available
  3. Fluid Mechanics Lab 15 Products available
  4. Heat Transfer Lab 10 Products available
  5. Theory Of Machine Lab 9 Products available
  6. Refrigeration & Air Conditioni 7 Products available
  7. Testing Equipment 6 Products available
  8. Generators 6 Products available
  9. Thermodynamics Lab 4 Products available
  10. Laboratory Equipments 3 Products available
  11. Others Products 66 Products available

Refrigeration & Air Conditioni

We offer a complete product range of Refrigeration Trainer - Domestic Type, Ice Plant Trainer, Air Conditioning Trainer, Air Conditioning Trainer - Window Type and Water Cooler Trainer

Refrigeration Trainer - Domestic Type

  • Brand Name UNICON
We are offering refrigeration trainer - domestic type refrigeration trainer - domestic type:the unit enables students to study the various parameters affecting the performance of a domestic refrigerator. It consists of refrigeration cycle of domestic refrigerator, it consists a hermetically sealed compressor, air-cooled condenser, capillary tube and a natural convection type evaporator. The evaporator is fitted with a small heater to simulate different load conditions various measurements are provided so that power consumption, cop, theoretical and actual refrigerating effects refrigerant flow rate and effect of door opening on power consumption can be studied and also students can visualize automatic operation of unit using a thermostat. Specifications:1. Compressor - hermetically sealed, kirioskar make having capacity of approx. 125 ton of refrigeration.2. Air - cooled condenser with natural convection airflow.3. Capillary tube of matched length as expansion device.4. Evaporator coil with an electric heater inside and adequate glass wool insulation on all side.5. Measurementenergymeter tore compressor input power measurement.pressure gauge for condensing and evaporating pressure.flow meter for liquid refrigerant flowdigital temperature indicator for measurement of temperature6. Safety & controls high & low pressure cutout.thermostat.necessary switches.A technical manual accompanies the unit. Also, the unit is provided with an attractive and rust proof powder coating. Services required:floor space of 2m x 1m.230v ac stabilized supply with earthing connection
View Complete Details

Ice Plant Trainer

We are offering ice plant trainer ice plant trainer : the plant uses ice can system. The cans filled with fresh wafer are kept in a tank in which brine is circulated. The brine is cooled by the refrigerant, which in turn cools the water in can and ice formation takes place. specifications: compressor : kirioskar make hermetically sealed compressor using r 12 refrigerant.Condenser : 4 row type air cooled.Expansion valve : 0.5 tr capacity.Evaporator : 12" o.d. Copper tube - 75 feet long.Filter drier : silica gel filled - 38" flare connections.Main tank : 600 mm x 375 mmtotal ice cane capacity : 7 kgice making capacity : 7 kg 4 hours.Thermocol insulation : 6.5"brine stirrer : motor driven fan, 1 phase, 110 hp, 1440. instrumentation: temperature indicator : digital type o300c, with 1 c least count, using cral thermocouples. Accuracy 1 % of full reading.Compressor energy meter : single phase, 10 - 20 amp. Capacity.Pressure gauge:v 0-21 kgcm2v -1 to 10.6 kgcm2v both of 65 mm dial.Digital thermometer controls : hplp cutout : auto reset type.Thermostat : auto reset type. a technical manual accompanies the unit. services required: floor area - 2m. X 1.5m. X 1.5m. Height.220 v., 15 amp.single phase stabilized power supply
View Complete Details

Air Conditioning Trainer

We offer air conditioning trainer. The unit consists of ducting fitted with various air conditioning components. Airflow is generated by an axial flow fan and in the airflow, heaters, cooling coil and steam humidifier connection is provided. Cooling circuit consists of a hermetic compressor; air cooled condenser, thermostatic expansion valve and evaporator (i.e. Cooling coil). Measurements of various parameters torn cooling cycle and heating cycle are provided and students can easily visualize and understand the basic principles of air conditioning. specifications 1. Cooling circuits - it consists of:hermetic compressor, having the capacity of 23 ton of refrigeration (approx.) using r-22 refrigerant. rotameter for liquid refrigerant flow measurement. pressure gauges for high and low pressure. prescott (i.e. High and low pressure cut-out). thermometers for temperature measurement at various points in the cycle. energymeter for compressor input measurement. condensate measuring arrangement. 2. Heating circuit - air heaters with input control provided with energymeter for input measurement. Maximum heating capacity 1 kw. 3. Steam generator and injector for humidification of air. All above components are connected to a duct of size 200mm. X 200mm. In which airflow is generated by axial flow fan. 4. Anemometer for measurement of air velocity, (range 0-15 msec. Following experiments can be conducted on the unitcooling of atmospheric air. heating of atmospheric air. humidification of atmospheric air. dehumidification and heating of atmospheric air. (cooling coil acts as dehumidifier at reduced airflow.) services required: 440 v, 15 a, 3 phase supply with earthing connection. floor space area about 3 m. X 2 m.
View Complete Details

Air Conditioning Trainer - Window Type

We offer air conditioning trainer air conditioning trainer - window type:window air conditioner is becoming now a days necessity. The unit demonstrates the application of window air conditioner & evaluation of its performance. It consists of a small room to which a small air conditioner is connected the room is provided with a transparent front cover with a heater inside to simulate heat load in the room. Various measurements are provided so that performance of system that is cop of system, actual & theoretical cooling capacity of system & power consumption of unit with different load conditions.Specifications:1. compressor - hermetically sealed, kirloskar make, having the capacity of 110 ton of refrigeration using r-12 refrigerant to keep room temperature between 20 to 30 c.2. condenser - finned tube type, with forced air flow over the tubes, 3. capillary tube of matched length as expansion device.4. evaporator - finned tube type with forced air flow, 5. room 0.6 x 0.7 x 0.7 m. Height, provided with transparent front wall. A heater with input control is provided inside the room. Which simulates different load conditions.6. measurements and controlsh.p. l.p. Pressure gaugesdigital temperature indicator to measure the temperatures at variouspoints.energy meters to measure input to compressor & heater.high and low pressure cutout.thermostat to put off the compressor at set room temperature.necessary switch for electrical components.Services required:1. floor area of 2m x 1 m.2. 230v, 15ac stabilized supply with earthing connection
View Complete Details

Water Cooler Trainer

Water Cooler Trainer Water Cooler Trainer: The apparatus consists of a storage water tank, embraced by evaporator coil of the cooling unit, cooling cycle comprises of a hermetically sealed compressor, air-cooled condenser, a capillary tube as expansion device and an evaporator cell. The stainless steel water tank is provided with insulation on air Sides and a door are provided at the top. Cold water can be taken out from a top provided and inlet water supply is controlled by a bail-operated top. Various measurements provided enable students to determine the theoretical and actual COP, power consumption, actual cooling capacity refrigerant flow and compressor volumetric efficiency of compressor. SPECIFICATIONS : Cooling Cyclev Compressor Hermetically sealed type, having the capacity of 13 ton of refrigeration using R-12 refrigerant. v Finned tube type air colled condenser with forced air flow. v Filter cum drier for refrigerant. v Capacity expansion device. v Evaporator coil embraced on stainless steel water tank, Provided with glass wool Insulation. Water drain tap and float operated inlet water tap are provided for water tank with insulated lift door at top.Measurement v Pressure gauges for evaporating and condensing pressure. v Thermometers to measure refrigerant temperatures at inlet and out let of condenser and evaporator. v Dial type thermometer for water temperature. v Rotameter to measure liquid refrigerant flow. v Energymeter to measure compressor Input. Safely & Controls - v Thermostat to put off compressor at set water temperature. v Pressostat to put off compressor if high or low pressure Goes out of set limit. v Over load protector for compressor, A technical manual will be supplied along - with the unit. Also, the unit is provided with an attractive and anti corrosion powder costing.
View Complete Details

Refrigeration Trainer

  • Brand Name UNICON
We offer Refrigeration Trainer. The unit consists of vapor compression refrigeration cycle provided with components normally used in refrigeration system so that student can get familiar with the components. Various measurement provided enable students to estimate the performance of the system. SPECIFICATIONS: 1. Compressor- Hermetically sealed compressor, having capacity of 0.3 T. 2. Expansion DevicesThermostatic Expansion ValveCapillary tube. 3. Evaporator coil. 4. Controls:Services Valve Solenoid ValveFilter-Drier for refrigerantHighLow pressure cutoutThermostat. 5. Measurements:v Thermometers (mercury in glass) - 4 Nos. V Pressure gauges for condensing and evaporating pressure. V Energymeter for compressorv Voltmeter and Ammeter for compressor. V Rotameter for liquid refrigerant flow measurement. A technical manual is accompanies the unit. SERVICES REQUIRED 1. Floor surface area - 1m x 2m x 2m height. 220V, I5Amp, Single Phase Stabilized power supply
View Complete Details

Mechanical Heat Pump Trainer

We are offering mechanical heat pump trainer. Heat pump is a device to pump heat from one source to another. Theheat obtained by heat pump is more than that could be obtained by direct electrical heating. The apparatus consists of refrigeration system with water cooled shell and coil type evaporator and condenser. specifications: 1. Compressor - hermetically sealed compressor using r-12 refrigerant, having capacity 0.3 tons of refrigeration. Condensing pressure - max. 15 kgcm2 (actual pressures will depend upon working conditions).2. Condenser - shell and coil type with continuous water flow arrangement.3. Evaporator - shell and coil type with continuous water flow arrangement.4. Expansion valve - internally equalized thermostatic expansion valve.5. Measurements -rotameter for condenser & evaporator water flow rate measurement.rotameter for liquid refrigerant flow measurement.pressure gauges for condensing and evaporating pressure - 2 nos.thermometer for refrigeration cycle & water temp, measurement - 7wattmeter for compressor input measurement.ammeter for compressor current measurement.6.controls -hplp cutout for compressor.overload protector for compressor.gate valve to control water flow rates.necessary switches and fuse. a technical manual is accompanies the unit. services required: floor surface area - 2m, x 2m. X 1.5m. Height.220v. 15amp. Single phase stabilized power supply.
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

Manufacturer of Refrigeration & Air Conditioni from Ambala, Haryana by Unicon Instruments
Post Buy Requirement

Our Products

  1. ANALOG AND DIGITAL LAB 62 Products available
  2. ITI EQUIPMENTS 18 Products available
  3. Fluid Mechanics Lab 15 Products available
  4. Heat Transfer Lab 10 Products available
  5. Theory Of Machine Lab 9 Products available
  6. Refrigeration & Air Conditioni 7 Products available
  7. Testing Equipment 6 Products available
  8. Generators 6 Products available
  9. Thermodynamics Lab 4 Products available
  10. Laboratory Equipments 3 Products available
  11. Others Products 66 Products available

Refrigeration & Air Conditioni

We offer a complete product range of Refrigeration Trainer - Domestic Type, Ice Plant Trainer, Air Conditioning Trainer, Air Conditioning Trainer - Window Type and Water Cooler Trainer

Refrigeration Trainer - Domestic Type

  • Brand Name UNICON
We are offering refrigeration trainer - domestic type refrigeration trainer - domestic type:the unit enables students to study the various parameters affecting the performance of a domestic refrigerator. It consists of refrigeration cycle of domestic refrigerator, it consists a hermetically sealed compressor, air-cooled condenser, capillary tube and a natural convection type evaporator. The evaporator is fitted with a small heater to simulate different load conditions various measurements are provided so that power consumption, cop, theoretical and actual refrigerating effects refrigerant flow rate and effect of door opening on power consumption can be studied and also students can visualize automatic operation of unit using a thermostat. Specifications:1. Compressor - hermetically sealed, kirioskar make having capacity of approx. 125 ton of refrigeration.2. Air - cooled condenser with natural convection airflow.3. Capillary tube of matched length as expansion device.4. Evaporator coil with an electric heater inside and adequate glass wool insulation on all side.5. Measurementenergymeter tore compressor input power measurement.pressure gauge for condensing and evaporating pressure.flow meter for liquid refrigerant flowdigital temperature indicator for measurement of temperature6. Safety & controls high & low pressure cutout.thermostat.necessary switches.A technical manual accompanies the unit. Also, the unit is provided with an attractive and rust proof powder coating. Services required:floor space of 2m x 1m.230v ac stabilized supply with earthing connection
View Complete Details

Ice Plant Trainer

We are offering ice plant trainer ice plant trainer : the plant uses ice can system. The cans filled with fresh wafer are kept in a tank in which brine is circulated. The brine is cooled by the refrigerant, which in turn cools the water in can and ice formation takes place. specifications: compressor : kirioskar make hermetically sealed compressor using r 12 refrigerant.Condenser : 4 row type air cooled.Expansion valve : 0.5 tr capacity.Evaporator : 12" o.d. Copper tube - 75 feet long.Filter drier : silica gel filled - 38" flare connections.Main tank : 600 mm x 375 mmtotal ice cane capacity : 7 kgice making capacity : 7 kg 4 hours.Thermocol insulation : 6.5"brine stirrer : motor driven fan, 1 phase, 110 hp, 1440. instrumentation: temperature indicator : digital type o300c, with 1 c least count, using cral thermocouples. Accuracy 1 % of full reading.Compressor energy meter : single phase, 10 - 20 amp. Capacity.Pressure gauge:v 0-21 kgcm2v -1 to 10.6 kgcm2v both of 65 mm dial.Digital thermometer controls : hplp cutout : auto reset type.Thermostat : auto reset type. a technical manual accompanies the unit. services required: floor area - 2m. X 1.5m. X 1.5m. Height.220 v., 15 amp.single phase stabilized power supply
View Complete Details

Air Conditioning Trainer

We offer air conditioning trainer. The unit consists of ducting fitted with various air conditioning components. Airflow is generated by an axial flow fan and in the airflow, heaters, cooling coil and steam humidifier connection is provided. Cooling circuit consists of a hermetic compressor; air cooled condenser, thermostatic expansion valve and evaporator (i.e. Cooling coil). Measurements of various parameters torn cooling cycle and heating cycle are provided and students can easily visualize and understand the basic principles of air conditioning. specifications 1. Cooling circuits - it consists of:hermetic compressor, having the capacity of 23 ton of refrigeration (approx.) using r-22 refrigerant. rotameter for liquid refrigerant flow measurement. pressure gauges for high and low pressure. prescott (i.e. High and low pressure cut-out). thermometers for temperature measurement at various points in the cycle. energymeter for compressor input measurement. condensate measuring arrangement. 2. Heating circuit - air heaters with input control provided with energymeter for input measurement. Maximum heating capacity 1 kw. 3. Steam generator and injector for humidification of air. All above components are connected to a duct of size 200mm. X 200mm. In which airflow is generated by axial flow fan. 4. Anemometer for measurement of air velocity, (range 0-15 msec. Following experiments can be conducted on the unitcooling of atmospheric air. heating of atmospheric air. humidification of atmospheric air. dehumidification and heating of atmospheric air. (cooling coil acts as dehumidifier at reduced airflow.) services required: 440 v, 15 a, 3 phase supply with earthing connection. floor space area about 3 m. X 2 m.
View Complete Details

Air Conditioning Trainer - Window Type

We offer air conditioning trainer air conditioning trainer - window type:window air conditioner is becoming now a days necessity. The unit demonstrates the application of window air conditioner & evaluation of its performance. It consists of a small room to which a small air conditioner is connected the room is provided with a transparent front cover with a heater inside to simulate heat load in the room. Various measurements are provided so that performance of system that is cop of system, actual & theoretical cooling capacity of system & power consumption of unit with different load conditions.Specifications:1. compressor - hermetically sealed, kirloskar make, having the capacity of 110 ton of refrigeration using r-12 refrigerant to keep room temperature between 20 to 30 c.2. condenser - finned tube type, with forced air flow over the tubes, 3. capillary tube of matched length as expansion device.4. evaporator - finned tube type with forced air flow, 5. room 0.6 x 0.7 x 0.7 m. Height, provided with transparent front wall. A heater with input control is provided inside the room. Which simulates different load conditions.6. measurements and controlsh.p. l.p. Pressure gaugesdigital temperature indicator to measure the temperatures at variouspoints.energy meters to measure input to compressor & heater.high and low pressure cutout.thermostat to put off the compressor at set room temperature.necessary switch for electrical components.Services required:1. floor area of 2m x 1 m.2. 230v, 15ac stabilized supply with earthing connection
View Complete Details

Water Cooler Trainer

Water Cooler Trainer Water Cooler Trainer: The apparatus consists of a storage water tank, embraced by evaporator coil of the cooling unit, cooling cycle comprises of a hermetically sealed compressor, air-cooled condenser, a capillary tube as expansion device and an evaporator cell. The stainless steel water tank is provided with insulation on air Sides and a door are provided at the top. Cold water can be taken out from a top provided and inlet water supply is controlled by a bail-operated top. Various measurements provided enable students to determine the theoretical and actual COP, power consumption, actual cooling capacity refrigerant flow and compressor volumetric efficiency of compressor. SPECIFICATIONS : Cooling Cyclev Compressor Hermetically sealed type, having the capacity of 13 ton of refrigeration using R-12 refrigerant. v Finned tube type air colled condenser with forced air flow. v Filter cum drier for refrigerant. v Capacity expansion device. v Evaporator coil embraced on stainless steel water tank, Provided with glass wool Insulation. Water drain tap and float operated inlet water tap are provided for water tank with insulated lift door at top.Measurement v Pressure gauges for evaporating and condensing pressure. v Thermometers to measure refrigerant temperatures at inlet and out let of condenser and evaporator. v Dial type thermometer for water temperature. v Rotameter to measure liquid refrigerant flow. v Energymeter to measure compressor Input. Safely & Controls - v Thermostat to put off compressor at set water temperature. v Pressostat to put off compressor if high or low pressure Goes out of set limit. v Over load protector for compressor, A technical manual will be supplied along - with the unit. Also, the unit is provided with an attractive and anti corrosion powder costing.
View Complete Details

Refrigeration Trainer

  • Brand Name UNICON
We offer Refrigeration Trainer. The unit consists of vapor compression refrigeration cycle provided with components normally used in refrigeration system so that student can get familiar with the components. Various measurement provided enable students to estimate the performance of the system. SPECIFICATIONS: 1. Compressor- Hermetically sealed compressor, having capacity of 0.3 T. 2. Expansion DevicesThermostatic Expansion ValveCapillary tube. 3. Evaporator coil. 4. Controls:Services Valve Solenoid ValveFilter-Drier for refrigerantHighLow pressure cutoutThermostat. 5. Measurements:v Thermometers (mercury in glass) - 4 Nos. V Pressure gauges for condensing and evaporating pressure. V Energymeter for compressorv Voltmeter and Ammeter for compressor. V Rotameter for liquid refrigerant flow measurement. A technical manual is accompanies the unit. SERVICES REQUIRED 1. Floor surface area - 1m x 2m x 2m height. 220V, I5Amp, Single Phase Stabilized power supply
View Complete Details

Mechanical Heat Pump Trainer

We are offering mechanical heat pump trainer. Heat pump is a device to pump heat from one source to another. Theheat obtained by heat pump is more than that could be obtained by direct electrical heating. The apparatus consists of refrigeration system with water cooled shell and coil type evaporator and condenser. specifications: 1. Compressor - hermetically sealed compressor using r-12 refrigerant, having capacity 0.3 tons of refrigeration. Condensing pressure - max. 15 kgcm2 (actual pressures will depend upon working conditions).2. Condenser - shell and coil type with continuous water flow arrangement.3. Evaporator - shell and coil type with continuous water flow arrangement.4. Expansion valve - internally equalized thermostatic expansion valve.5. Measurements -rotameter for condenser & evaporator water flow rate measurement.rotameter for liquid refrigerant flow measurement.pressure gauges for condensing and evaporating pressure - 2 nos.thermometer for refrigeration cycle & water temp, measurement - 7wattmeter for compressor input measurement.ammeter for compressor current measurement.6.controls -hplp cutout for compressor.overload protector for compressor.gate valve to control water flow rates.necessary switches and fuse. a technical manual is accompanies the unit. services required: floor surface area - 2m, x 2m. X 1.5m. Height.220v. 15amp. Single phase stabilized power supply.
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us