Machine Feature
Machine Technical Specification
Measuring range | AC [50HZ] DC | 50 kv 50 kv | 100 kv 100kv | 200 kV 200 kV |
---|---|---|---|---|
Accuracy | AC [50HZ] DC | 1.50% 1.00% | 1.5% 1.0% | 1.5% 1.0% |
Resistance | R [ M ] C [pF] | 640 300 | 1280 150 | 2560 75 |
Divide ratio | K | 1000 | 1000 | 1000 |
Disply | LCD | LCD | LCD | |
Maximum error | AC DC | 750V 500V | 1500V 1000V | 3000V 2000V |
Meter input resistance | 10 M⦠| 10 MM⦠| 10 M⦠| |
Dimensions [mm] | 200x200x520 | 200x200x850 | 200x200x1160 | |
Weight [kg] | 9.5 | 13.5 | 18.5 | |
Ambient | Temperature Relative humidity | 20 ± 15º C To 80 % non condensing |
Machine Feature
1. Makes test easy and quickly
2. All calculations are based on known standard theory, which is widely accepted.
3. Fully digital processing through embedded microprocessor enables high accuracy, reliability and stability.
4. Two isolated channels to input the leakage current and reference signal which eliminates the magnetic interference.
5. Big LCD with backlit and four key operation menu.
Standard Accessory
Fully automatic 1 and 3 phase TTR meter.
Additional Information:
Payment Terms : T/T
Delivery Time : ready stock
Test Standards | IEC 60044-1, IEC 60044-2, IEC 60044-6 |
---|---|
Power Output | 0.1 to 180V (AC) |
Current Output | 0.001 to 5A (RMS) |
Power Output | 300VA |
Test Frequency | : 0.1 to 60Hz |
Maximum Knee Voltage Measurements | : 45KV |
Current Measurement | Range: 0-10A (auto-range: 0.1A / 0.4A / 2A / 10A) Error <± 0.1% RDG to 0.01%FS |
Voltage Measurement | Range: 0-200V (auto-range: 1V / 10V / 70V / 200V) Error <± 0.1% RDG to 0.01%FS |
Turns Ratio Measurement | Range: 1 to 35000 :1-2000 error <0.05% RDG :2000-5000 error < 0.1% RDG 5000-35000 error < 0.2% RDG |
Phase Measurement | Error <± 2 min, resolution: 0.01 min |
Coil Resistance Measurement | 0 to 8 kohm (auto-range: 2 ohm/20 ohm/80 ohm/800 ohm/8 k ohm) Error <± 0.2% RDG to 0.02% FS :Maximum resolution: 0.1 Milli ohm |
Temperature Measurement | -50 to 100°C, error: <3°C. |
CT Secondary Burden | 0 to 160 ohm (auto-range:2 ohm/20ohm/80ohm/160 ohm) : Error <± 0.2% RDG to 0.02% FS : Maximum Resolution: 0.001 ohm |
PT Secondary Burden | 0 to 80 kohm (auto-range: 800 ohm/8 k ohm / 80 kohm) : Error <± 0.2% RDG to 0.02% FS : Maximum Resolution: 0.1 ohm |
PT Ratio Measurement | Range: 1 to 35000 : 1-5000 error < 0.2% : 5000-35000 error < 0.5% |
PT Phase Angle Measurement Error | < 30 min |
Saved Data Groups | > 1000 groups |
Power Supply | AC 220V ± 10%, 50Hz / 60 Hz |
Dimensions | 485mm x 356mm x 183mm approximate |
Weight | < 13 Kg approximate |
POWER SUPPLY | 230V± 10% AC, 50-60 Hz |
---|---|
O / P VOLTAGE | Excitation Characteristics : 0 ~ 1000 Volts |
O / P CURRENT | Excitation : 0 ~ 15 Amp |
CURRENT INJECTION | 0 ~ 600 Amp |
ACCURACY DISPLAY | ± 0.5% :Back lit large LCD |
MEMORY | 3000* results |
PRINTER | Built in Printer |
PC INTERFACE | USB Flash disc |
CONSTRUCTION | Aluminum Cabinet |
USE ENVIRONMENT | Temperature: Max 45°C Relative Humidity : 80% non-condensing |
DIMENSION | L x W x 0 x 20 x 26cm Approx. |
WEIGHT | 18 kg Approx. |
Machine Technical Specification
Measuring range | AC [50HZ] DC | 50 kv 50 kv | 100 kv 100kv | 200 kV 200 kV |
---|---|---|---|---|
Accuracy | AC [50HZ] DC | 1.50% 1.00% | 1.5% 1.0% | 1.5% 1.0% |
Resistance | R [ M ] C [pF] | 640 300 | 1280 150 | 2560 75 |
Divide ratio | K | 1000 | 1000 | 1000 |
Disply | LCD | LCD | LCD | |
Maximum error | AC DC | 750V 500V | 1500V 1000V | 3000V 2000V |
Meter input resistance | 10 MΩ | 10 MMΩ | 10 MΩ | |
Dimensions [mm] | 200x200x520 | 200x200x850 | 200x200x1160 | |
Weight [kg] | 9.5 | 13.5 | 18.5 | |
Ambient | Temperature Relative humidity | 20 ± 15º C To 80 % non condensing |
Output*: | Measuring Range: |
---|---|
Test voltage: 0.5 ~ 12 kV, user-selectable The output test voltage tolerance of the CDF-6000 is +1% of the selectedtest voltage and remains stable along the duration of the test, un-affected by line or input voltage fluctuations.Test current: 200 mA maximum |
Test capacitance range @ 50 Hz / 60Hz. • Internal power supply 200 mA max. 3pF ~ 0.05µF @ 12kV 60pF ~ 1µF @ 0.5kV • External power supply, 5A max. 3pF ~1.25µF@12kV • Resolution: 0.001pF, 4 digits |
* If higher than 12 kV test voltage, higher current or extended test capacitance is desired, the CDF-6000 allows interface with an external power supply and external reference capacitor while using its bridge circuit to take measurements and output results. | Tan δ range: 0 ~100%, resolution .001% Voltage: 0~12kV Current: 10µA~5A Also displays the phase angle, frequency, watts loss, insulation power factor or tan delta, resistance (in the case of resistive specimens), inductance and quality factor (in the case of inductive specimens). |
Accuracy: | |
Capacitance: +1% of reading + 1pF Tan : +1% of reading +.00040 Voltage: +1% of reading. |
Machine Feature
Programmable micro-controllerAdvanced digital frequency technologyBuilt-in printerPortableAC HIPOT testing of cables and electrical apparatus is now easier than beforeUDEY VLF testers are suitable for testing cables, transformers, switchgear, rotating machinery, & other electrical apparatus.
Model | Output | Load Carring Capacity | Control Unit | Booster | ||
---|---|---|---|---|---|---|
Dim(cm) | Wt(Kg) | Dim(cm) | Wt(Kg) | |||
VL-32 | 30kV/20mA | 0.1Hz<=1.1µF 0.05Hz<=2.2µF 0.02Hz<=5.5µF |
28x37x22 | 5 | 33x18x34 | 25 |
VL-53 | 50kV/30mA | 0.1Hz<=1.1µF 0.05Hz<=2.2µF 0.02Hz<=5.5µF |
28x37x22 | 6 | 37x24x39 | 40 |
VL-85 | 80kV/50mA | 0.1Hz<=1.1µF 0.05Hz<=2.2µF 0.02Hz<=5.5µF |
28x37x22 | 7 | 33x18x34 37x24x39 |
25 40 |
Machine Feature
OUTPUT: Adjustable Frequency: 50Hz, 60HZ, 4570Hz, 100Hz, 200Hz and 400Hz Adjustable Voltage in two ranges: 0150300V
Pure Sine wave sinusoidal output
Low harmonic distortion
Digital display real time data: Frequency, Voltage, Current, Power and Power Factor
Solid state with proven advanced IGBT and SPWM technology
Protection for Short-circuit, Over-current, Over-load, Over-heat with audio alarm.
Simplicity in operation:
Plug and socket connections with few knobs mean minimal operator training. LED digital displays for output Frequency, Voltage, Current, Power and Power Factor.
Protection for Short-circuit, Over-current, Over-load and Over-heat is provided to ensure proper operation with audio alarm.
UDEY-FRIVO is built in single unit sheet steel cabinets. Output is available on 3-pin sockets for connecting the load. The power supply is very compact and low in weight.
Applications:
UDEY- FRIVO series are suitable for applications ranging from production-line testing through to research and development laboratories, workshops, shipyard, ship manufacturing and repair plants, etc.
MODEL | FRIVO-5 | FRIVO-10 | FRIVO-30 | FRIVO-50 | |||||
---|---|---|---|---|---|---|---|---|---|
Output Capacity | 500 VA | 1000 VA | 3000 VA | 5000 VA | |||||
Circuit | IGBT / SPWM | ||||||||
INPUT: AC | Phase | Single phase two wire | |||||||
Voltage | 220V ± 10% | ||||||||
Frequency | 47 – 63 Hz | ||||||||
OUTPUT: AC (adjustable) | Phase | Single phase two wire | |||||||
Voltage | Range a) Low: 0 – 150 V b) High: 0 – 300 V | ||||||||
Frequency | 1) 45 – 70 Hz 2) 50 Hz 3) 60 Hz, 4) 100 Hz 5) 200 Hz 6) 400 Hz |
1) 45 – 70 Hz 2) 50 Hz 3) 60 Hz, 4) 400 Hz |
|||||||
MAXIMUM CURRENT | Low = 120 V | 4.2 A | 8.4 A | 25 A | 42 A | ||||
High = 240 V | 2.1 A | 4.2 A | 12.5 A | 21 A | |||||
Frequency stability | ± 0.05% | ||||||||
Voltage stability | ± 0.5 % | ||||||||
Waveform | Sine wave | ||||||||
Waveform distortion | ≤ 2% (resistive load) | ||||||||
Efficiency | > 85% | ||||||||
Response time | ≤ 2 ms | ||||||||
Display, Resolution, Accuracy | Frequency | Display: 4 digits; Resolution: 0.1Hz; Accuracy: 1% | |||||||
Voltage | Display: 4 digits; Resolution: 0.1V; Accuracy: 1% | ||||||||
Current | Display: 4 digits; Resolution: 0.01A; Accuracy: 1% | ||||||||
Power | Display: 4 digits; Resolution: 1W; Accuracy: 1% | ||||||||
Power factor | Display: 4 digits; Resolution: 0.001; Accuracy: 1% | ||||||||
Protection | Over-voltage, over-current, over-load, over-heat and short-circuit with audio alarm cutting off power. Input and output circuit breakers in model FRIVO 30 and FRIVO 50. | ||||||||
Cooling | Forced fan cooling | ||||||||
Working ambient | 0° – 45° C; R.H. max 85% non-condensing | ||||||||
Mass | Dimensions | 42 x 42 x 19 cm | 42 x 52 x 60 cm | ||||||
Weight | 24kg | 26kg | 70kg | 85kg | |||||
Accessories | 3-core mains cord, 2 m long | 3- mains wire, 2 m long |
Power Supply | 230V ± 10%, AC 50 Hz |
---|---|
Measuring Range | 9999/9.999/99.99/999.9/9999 seconds |
Measuring Accuracy | Range: ±0.05% ± 1 count |
Display | LED 12.5 mm; 4 digit with decimal |
Protection of Input Signal | up to 240V AC / DC |
In Contacts [Potential Free] | OPEN: 100K or more CLOSED: 100 ohm or less |
Auxiliary output contact | 1 change over potential free. Rating 1A 240V AQC or 24V DC. |
Operating Modes | Time interval measurement; stop watch. 1) Start/Stop by potential free open contact closing 2) Start/Stop by potential free close contact Opening 3) Starts by step +ve voltage application (50-250V DC) 4) Stops by step +ve voltage removal (50-250V DC) |
Usage Environment | : Less than 45°C. Less than 85% R.H. |
Enclosure | ABS body with tilting handle. |
Dimensions | : 21.5 (W)x23(D)x9(H) cm approx. |
Weight | : 1.8 kg approx. |
Range |
|
---|
Accessories | Power supply cord 3 core. Flexible testing cable set with alligator clamps. Operating Manual. |
---|