Transformers

Our Complete range of products are Current Transformers, Power Transformer, Potential Transformer, Residual Voltage Transformer and booster transformers.

Current Transformers

Truvolt Engineering Co. Pvt. Ltd. is the foremost Current Transformers Manufacturer, Exporter and Supplier in Kolkata, West Bengal. These Current Transformers are greatly appreciated for their accurate functionality and are highly demanded in the market. These Current Transformers are made in accordance to the industry standards and are reasonably priced. ApplicationsDirect measurement of current in high voltage & high current system is not possible because of difficulty in electrical isolation of measuring instruments. It is also not possible to use current flowing through the system directly for protection purpose due to its high value and difficulty in electrical isolation of protective relays. Therefore, Current Transformers are used to step-down the high system current to standard value accurately in proportion to their ratio. Basic Functions of Current Transformer are
  • To reduce the line current to a value, which is suitable for standard measuring instruments, relays, etc
  • To isolate the measuring instruments, meters, relays etc. From high voltage side of an installation
  • To protect measuring instrument against short circuit currents
  • To sense abnormalities in current and give current signals to protective relays to isolate the defective system
TheoryA current transformer operates on the principle of balance of Ampere turns in primary and secondary winding. Voltage Es developed across secondary of the current transformer can be represented as ES=ZS x is where Zs is impedance of burden, connection leads and CT secondary. The magnetic flux required to develop voltage Es needs excitation current i.e. this excitation ampere turns are supplied through total primary ampere turns, causing error in the magnetic material. Errors in the current transformer are also non-linear over the current range of 120% to 5%. There are four main factors which determine the capability of current transformer i.e.
  • Insulation Level (Service Voltage)
  • Rated primary current
  • Short time withstand current
  • Burden and Accuracy
Current Transformer Must
  • Withstand operational voltage and over voltage in the network
  • Withstand rated primary current in continuous operation without exceeding maximum allowed temperature rise
  • Be capable to sustain thermal and mechanical stresses developed due to system fault current
  • Feed current to external circuit with specified accuracy at specified primary currents
DesignWe manufacture current transformers in both types i.e. Live Tank Design and Dead Tank Design. Current transformer can be designed for single ratio or multi ratio. The ratio selection can be achieved by providing two or four sections of primary for series/parallel reconnection. However, the current ratio shall be in proportion of 1:2:4 the advantage of this type of ratio selection ratio. Ratio selection is also possible by giving taps on the secondary winding. Advantage of this type is that ratio can be achieved in any multiple of the lowest ratio. It is also possible to change the ratio on CT without taking shut down on the man system. However, it is obvious that output rating shall change as per the ratio. For multi ratio CT, 2 or 3 ratios can be provided by primary series-Parallel reconnection and additional ratios by secondary taps. High output (Burden/Knee point Voltage / Accuracy Limiting Voltage) with minimum excitation current and better accuracy class can be provided on the CT if primary current is higher. Higher output can also be obtained with multi-turn primary design. Limitations on no. of primary turns are, however, imposed by short time current rating and peak dynamic current. It is advisable to provide minimum primary turns to limit the dynamic forces and mechanical stress experienced by the CT under fault conditions. ConstructionCore & Secondary Winding: High permeability, CRGO silicon steel is used as core material. Toroidal core from continuous strips are annealed in controlled atmosphere to achieve best quality secondary cores. Secondary winding is done on automatic winding machine and is distributed equally on the periphery of the core to minimize leakage reactance. Best quality enameled copper wire with adequate inter-layer insulation is provided to avoid secondary winding short circuiting in most adverse condition. Primary WindingPrimary winding is of braided electrolytic copper conductor with double cotton covering. Varnished fiberglass sleeve is provided as an additional insulation on this conductor. In case of live tank construction, the primary is wound on insulated secondary. The primary is positioned property to sustain dynamic forces developed during short circuit condition. In case of Dead Tank construction, the primary is encapsulated in circular rigid fibre glass ring and galvanized pipe to form Eye Bolt construction. InsulationHigh quality crepe insulating paper is used to build up main insulation of the CT in live tank design, insulation is built up on secondary core and secondary leads are brought out through a metallic galvanized pipe. In dead Tank CT primary winding is encapsulated in fibre glass ring and Aluminium pipe. Main insulation is built up on primary winding (paper condenser is formed on the pipe) with fine grading of insulation. Semi-conducting shield is used to give linear distribution of Electric stress along the length of the bushing, the paper insulation is dried in oven under very high vacuum and strictly controlled conditions. Filtered and de-aerated EHV Grade oil is filled in CT while CT is under vacuum. To seal it, the space left for expansion on the top is filled with dry and pure Nitrogen through non-returnable valve at predetermined pressure. Porcelain InsulatorBrown Glazed porcelain bushing with different shed profiles to suit different pollution conditions are use. These Bushings are hollow cylindrical type conforming to IS 5621/IEC & 815. Bushings with Collar at both the ends are clamped using Aluminium Flange, Nitrile and Neoprene Gaskets are used at both sides of collar to form flexible joint. This joint can sustain vibrations without damaging bushing. Bushings with cemented flanges are also used. Tank & BaseTop tank (which also acts as oil Expansion Chamber) of the CT having current less than 800 Amps is made of MS sheet. Stainless steel Tanks is used for CTS with primary current of 800 Amps. And above Base is fabricated from MS plates and channels all MS Tanks and Bases are painted with oven baked paint, after cleaning by seven tank process. All surfaces which come in contact with oil are painted with oil Insoluble Paint. All MS parts can be supplied Hot Dip Galvanized on request. TestingOur testing Lab is equipped with modern test facilities to carry out all routine tests including temperature rise test. Partial Discharge test plays vital role in quality control of insulation. All our Cts are tested for Partial Discharge on most modern bridge type Partial Discharge Test Set. All the Cts pass through a standardized quality assurance plan to ensure requisite top quality at every stage and in the final product. Packing & TransportationAll Cts are packed with strong jungle wood to take care of most adverse conditions of transportation all over the country. Special Seaworthy packing is done for the Cts for Export. MaintenanceThe Cts do not require maintenance apart from occasional cleaning of Bushings and checking of Nitrogen Pressure.
View Complete Details

Power Transformer

Truvolt Engineering Co. Pvt. Ltd. is a well-established Power Transformer Manufacturer, Exporter and Supplier in Kolkata, West Bengal. We manufacture these Power Transformers as per the approved quality norms and ensure that they function perfectly. Our Power Transformers are durable in nature and have features that make it easy to work with them. Our Power Transformers can be obtained at reasonable prices. ApplicationExclusively Power transformer are used for transmit the power over a long distance by step up or clown The voltage level in medium and low voltage sub-station . Ln greed station power transformer is used as a generating transformer there by power can be Fed in bi-directional way. It takes power from plant uses, when no necessity the power is fed to the greed from generated itself. Design Parameters
  • High factor of safety
  • Robust design
  • Low power consumption
  • High mechanical strength to withstand the symmetrical fault
  • Efficient voltage regulation
  • Well power transfer capacity and efficiency
Construction
  • Follow up the clearance with due respect of voltage class in accordance with IS-2026
  • Use of M.S core clamp with acid treatment, fine surface finishing and oil resistant painting
  • Use of strain less steel flitch plate core stud clamping rod by proper machining for obtaining the require dimensions
  • Use of M.S. Fabricated tank of every part fine surface finishing robust support with stiffeners with acid treatment and painted after sand blasting
  • Prime core of 0.27 mm thickness with 1.6 wblmz proper laminated core used at assembly stage and stiffen with poly glass tape by Iron pressed
  • Copper conductors & bar of 99.9 % Electrolytic grade copper with good conductivity used for making winding and insulated with paper insulating materials & wooden supports with well tested & high tensile strength good toughness
  • Brazing rod for copper bar connection of 42 % Rupatam is used
  • In tank type O.L.T.C or linier Flange type O.L.T.C is fitted for require amount of voltage out put
  • Permawood Ring for winding pressure, Wooden platform at Bottom side for uniform support
  • Wooden Bracket support on both primary & secondary side for connection Arrangement
  • Wooden bolts are used with wooden nut for proper joining
  • W.T.I C.T and N.C.T. on Both or either side with wooden bracket arrangement
  • After heating Adhesive used to avoid looseness
  • Pre-compressed board are used for making Cylinder, Ductstrip, Dove-tail support
  • Insulated core bolt with glass and M.S. Washer fitted with glass tube
Range : Up to 36 Mva 132 KV
View Complete Details

Potential Transformer

Direct Measurement of voltage in high voltage system is not possible because of difficulty in electrical isolation of measuring instruments. It is also not possible to use voltage for the system protection due to its high value and difficulty in electrical isolation of protective relays. Therefore, Voltage Transformers are used to step-down the high system voltage to standard value accurately in proportion to their ratio. Basic Functions of voltage Transformer are
  • To reduce the line Voltage to a value, which is suitable for standard measuring instruments, relays, etc
  • To isolate the measuring instruments, meters, relays etc. From high voltage side of an installation
  • To sense abnormalities in voltage and give voltage signals to protective relays to isolate the defective system
TheoryGeneral principles of power transformer design also apply to the voltage transformers but there are certain considerations of performance which are of particular importance. In the electromagnetic voltage transformers, accuracy depends on leakage reactance and winding resistance. These determine how the phase error and voltage error vary as the burden on secondary increases. The permeability and power dissipation of core material affects the exciting current and thus the error at zero burden. To comply with the requirement of IS:3156/IEC: 60044-2, Flux density employed in Voltage transformer is much less than the value generally used in power transformer. The turns ratio and voltage drop due to leakage DesignSingle Phase Electromagnetic Voltage Transformer (EMV) is manufactured in two types
  • Single Pole (To connect between line & Earth)
  • Both Pole (To connect between Line-to-Line)
  • hase Voltage Transformers are of star/star connected or star/Open delta connected (residual Voltage Transformer) type. Single Phase voltage transformers are manufactured for 11kV to 132kV system voltage, where as 3 phase voltage transformer are manufactured for 11 kV to 33 kV system voltage
ConstructionVoltage Transformer Mainly Consists of
  • Primary & Secondary Winding
  • Electromagnetic Core
  • Bottom Tank & Top Oil Expansion Chamber
  • Porcelain Bushing
  • Stainless Steel Bellow
Primary & Secondary WindingEnameled copper wire is used for winding. Primary is wound with multi layer and graded insulation. The diameter and length of each layer is selected such that surge voltage is distributed equally in all layers of the Winding. Multilayer Kraft Paper Insulation is provided between winding layers. Stress equalizing shield is provided on last layer of the winding. H.T. Connection is brought out through metallic galvanized pipe. Secondary is separately wound and inserted in the primary winding as per the requirement. Winding and taping of VT is done in dust free atmosphere. Electromagnetic CoreCRGO Silicon Steel Lamination is used for building up Electromagnetic Core. Shell type construction is used to minimize leakage reactance. Bottom Tank & Top Oil Expansion chamberBottom Tank and oil expansion chamber are made of M.S. Sheet. All tanks and chambers are painted with oven baked paint, after cleaning by seven tank process. All surfaces which come in contact with oil are painted with oil insoluble paint. M.S. Parts can be hot dip galvanized on request. Porcelain BushingBrown Glazed porcelain Bushing with different shed profiles to suit different pollution conditions is used. These Bushings are Hollow cylindrical Type Conforming to I.S. 5621/IEC 815. Bushing with collar at both the ends is clamped using Aluminium Flange. Nitrile and Neoprene Gaskets are used at both sides of collar to from flexible joint. This joint can sustain vibrations without damaging bushing. Bushings with cemented Flanges are also used. InsulationHigh quality Electrical Grade Kraft. Paper rand Crepe Paper is used for insulating primary and secondary winding of V.T. The high voltage connections is brought through paper condenser formed on metallic galvanized pipe using fine grading of insulation semi-conducting shield is used to give linear distribution of electric stress ailing the length of the bushing. The paper insulation is dried in oven under very high vacuum and strictly controlled conditions. Filtered and de-aerated EHV grade oil is filled in V.T., while V.T. is under vacuum. To seal it, the space left for expansion on the top is filled with dry and pure nitrogen through non-returnable valve at pre-determined pressure. TestingTruvolt Engg. Testing Lab is equipped with modem test facilities to carry out all routine test, including temperature rise test. Partial discharge Measurement plays a vital role in quality control of insulation. All our Vts are tested for Partial Discharge on most modern bridge type partial Discharge Test Set. All the Vts pass through a standardized quality assurance plan ensure requisite top quality at every stage and in the final product. Packing & TransportationAll Vts are packed with strong jungle wood to take care of most adverse conditions of transportation all over the country. Special seaworthy packing is done of the Vts for export. MaintenanceVts do not require maintenance apart from occasional cleaning of Bushings and checking of Nitrogen Pressure.
View Complete Details

Residual Voltage Transformer

Direct Measurement of voltage in high voltage system is not possible because of difficulty in electrical isolation of measuring instruments. It is also not possible to use voltage for the system protection due to its high value and difficulty in electrical isolation of protective relays. Therefore, Voltage Transformers are used to step-down the high system voltage to standard value accurately in proportion to their ratio.
View Complete Details

Booster Transformers

Where wide range of voltage variation auto transformers are used to get the fixed out put voltage by applying Automatic Tap Changing Equipment. In Rural power distribution line Auto transformer regulate the voltage to obtain require amount of out put voltage as auto booster .
View Complete Details

Power Transformer,Furnace,Substation ,Project Completion On Turnkey Basis

'TRUVOLT'manufactured transformers for 'salt bath', arc melting and medium frequency induction furnaces are successfully incorporated with reputed furnace manufacturers like GA Danielly, Inductotherm(India) Ltd., Wellman incandescent India Ltd., Wesman Engineering Co.Ltd., Megatherm Electronics Pvt. Ltd., Fire, Gas & klin, Electronic (India) Pvt.Ltd.as O.E.M.from as far back as 1960.Our transformers range varies from distribution, power to furnace transformer, scott connected, earthing, static balancing, isolation, welding, zigzag connected and salt bath transformers.Our technology know how, however, is not confined to transformers only.We are the largest manufacturers of crematorium furnaces in the country today.About 90% of the burning ghats under Ganga Action Plan has been designed, manufactured and commissioned by us.We have also exported crematorium to Dhaka, Bangladesh. We are also manufacturers of arc melting furnaces and heat treatment furnaces.Other products include unitized substation and transwitch unit for coal fields, CT/PT upto 33KV and automatic voltage regulating transformers for auto voltage regulating transformers for auto voltage sensing and correction within accuracy limit of +_ 1%, pollution control incinerator for solid waste management.TRUVOLT also undertakes design, supply, execution of upto 132KV substation on turn-key basis.We are ready to serve you with our vast experience in the electrical industry for so many years.We hope we will serve you upto your satisfaction.

Additional Information:

Payment Terms : L/C

Delivery Time : as per requirement

View Complete Details