DIGITAL VOLTS

Features
  • Available in 1Phase2Wire, 3Phase4Wire/3Wire system
  • Accuracy: Class 1.0 & Class 0.5 (Optional)
  • 0.56" Seven Segment LED (In Volt, Amp, Freq. & 1-Phase PF Meter)
  • 16 X 1 Line LCD (In KW300 & PF300)
Specifications
  • Direct Voltage Input: 0-300V AC for P-N & 0-500V AC P-P
  • Secondary Current: 0-5000A AC
  • Frequency range: 45-55Hz
  • PF range: 0.000-1.000
  • Size:96 X 96 X 55mm
View Complete Details

Three Phase Power Analyzer

Trinity has designed its Portable Power Analyzers, ORACLE to be the most versatile instrument available today. Oracle which is, Three Phase Power Analyzer and Recorder, is our next generation analyzer, including important new features requested by our customers. From substations, to commercial & industrial, to residential monitoring, Oracle has comprehensive measurement and power quality analysis capabilities. These high performance capabilities, combined with the latest in electronic technology, make it ideal for both utility and industrial applications.
View Complete Details

Power Analyzer

Trinity has designed its Portable Power Analyzers, ORACLE to be the most versatile instrument available today. Oracle which is, Three Phase Power Analyzer and Recorder, is our next generation analyzer, including important new features requested by our customers. From substations, to commercial & industrial, to residential monitoring, Oracle has comprehensive measurement and power quality analysis capabilities. These high performance capabilities, combined with the latest in electronic technology, make it ideal for both utility and industrial applications.
View Complete Details

Maximum Demand Controllers

The digital power meter GOBLIN is a micro-controller based unit which not only measures a host of electrical parameters to display them on a 128 x 64 backlit LCD, but also acts as a comprehensive load managing device due to its four numbers of output relay contacts. These outputs are individually field programmable for both the parameter on which to generate alarm as well as the values on which to activate alarm and deactivate it. In addition to this flexibility in terms of load management, the meter also has two serial ports: USB port and RS485. RS485 supports MODBUS RTU protocol for connections to EMSSCADA. Goblin has two USB ports-one where a cable connection to laptoppc is made(Device mode) and another where the unit directly accepts a pendrive(Host mode).
View Complete Details

Goblin

The digital power meter GOBLIN is a micro-controller based unit which not only measures a host of electrical parameters to display them on a 128 x 64 backlit LCD, but also acts as a comprehensive load managing device due to its four numbers of output relay contacts. These outputs are individually field programmable for both the parameter on which to generate alarm as well as the values on which to activate alarm and deactivate it. In addition to this flexibility in terms of load management, the meter also has two serial ports: USB port and RS485. RS485 supports MODBUS RTU protocol for connections to EMS/SCADA. Goblin has two USB ports-one where a cable connection to laptop/pc is made(Device mode) and another where the unit directly accepts a pendrive(Host mode).

The unit is meant for use in three phase four wire / three wire systems. The installation type, CT ratios and PT ratios are site selectable.

The Load Manager with its four relay contacts can be used as a Demand Controller. The method of Demand calculation is sliding window and fixed window.

Features
  • Accuracy Class 0.5 (as per IS14697)
  • Displays more than 20 Parameters.
  • Four Relay contacts, individually field programmable, for alarm parameter as well as on/off values.
  • RS-485 MODBUS-RTU Connectivity.
  • Large 128 x 64 graphical LC Display.
  • USB Port for downloading data
  • Directly accepts pen-drive to transfer logged data(Host mode)
  • On board 2MB of non-volatile memory. On board data logging with field programmable log duration.
  • CT / PT ratios field programmable.
  • Odd Harmonic Analysis up to 15th for all voltages and currents, including THD.

Parameter
Type Name Statistics
Input Three Phases and Neutral of a3P4W system / Three Phases of a 3P3W system
Voltage Direct Voltage Input: Up to 500V L-L, Up to 300VL-NPT
Ratio: Site Selectable
Burden: 0.5VA
Current Secondary Current Input:5A or 1A (Site Selectable)CT
Ratio: Site Selectable
Range of Reading:5 - 5000A
Burden: < 1.0VA
Overload: 5A CT = 6A RMS Continuous
1ACT = 1.2A RMS Continuous
Power Supply Auxiliary Supply: 90 - 480VAC, 50-60 Hz.
Output Relay Four. Individually Field Programmable.
Switching Voltage: Max. 230 VAC
Switching Power: Max. 1000W
Expected Mechanical Life: >10 x 106 switching operations
Expected Electrical Life: >4 x 106 switching operations
@(Load = 200VA, Coscp = 0.5)
Measurment True RMSBasicParameters Voltage(Volts L-N & L-L) Vl-n Accuracy: 0.5% of Reading
Vl-l Accuracy : 1.0% of Reading
Current(Amps IR, IY, IB) Accuracy: 0.25% of Reading
Line Frequency 45 to 55 Hz, Accuracy: 0.3%of Reading
Power ActivePower (P) Accuracy: 0.5% of Reading(For IPFI>0.5)
ReactivePower (Q) Accuracy: 1.5% of Reading
(Between 0.5 Lag to 0.8 Lead)
ApparentPower (S) Accuracy: 0.5% of Reading
Power Factor For Individual phases andSystem.
Accuracy : 1.0% of Reading (IPFI>0.5)
Range of Reading: 0.05 to1.00 Lag/Lead
Energy Total ActiveEnergy (KWh) Range of Reading : 0 to99999999.9 KWh
Accuracy : Class 0.5 as per IS14697
Total ApparentEnergy (KVAh) Range of Reading : 0 to99999999.9 KVAh
Accuracy : Class 0.5 as per IS14697
Total ApparentEnergy (KVARh) Range of Reading : 0 to99999999.9 KVARh
Accuracy : Class 1.0
Power Quality 3rd to 15thHarmonics(Odd) for all Voltages with THD
3rd to 15thHarmonics(Odd) for all Currents with THD
Demand Active Power (KW) Demand -Sliding & Fixed, Selectable
Apparent Power (KVA) Demand -Sliding & Fixed, Selectable
 
Miscellaneous Dimensions Bezel 144 X 144 mm
Panel Cutout 138 X 138 mm
Depth of installation 55 mm
  Display 128 X 64 graphical Backlit LCD
  Operating temp 10°C to 50°C
  Weight 0.65 Kgs (Approx.)
Communication OperatingCurrent Range 0.4% to 120% of CT primary
Data LoggingBuffer 2MB, Non-volatile memory,Can hold 19691 records
Logging Duration Site selectable from 1 minute to 60 minutes
RS485 Modbus-RTU protocol
USB port and directly access pen-drive for downloading logged data



















View Complete Details

Maximum Demand Controller

To protect our entire range of products from external factors that can be damaging, we have a state-of-the-art packaging unit equipped with the latest secure packaging technologies and materials. Our organization is renowned as reliable distributor in the industry and based in the well-connected state of Gujarat(India).
View Complete Details

Empower

EMPOWER from Trinity is an electrical power meter, for use in three phase three/four wire electrical systems. It measures the phase voltages, currents, PF, Hz, system KVA, system KW, system KVAr, Active Energy (KWh) and Apparent Energy (KVAh). The various parameters measured are displayed on a 4 digit x 3 Row Red 7 segment LED matrix for easy visibility and readability. The CT ratio (primary) can be programmed at site using the front membrane key. The meter uses state of the art Digital Signal Processing (DSP) circuitry to achieve very high accuracy measurement of true RMS value of all above parameters. The meter accuracy is class 1.0 for all parameters including KWh.

Features
  • Multiparameter monitoring.
  • Measures 16 Electrical values.
  • All parameters with default accuracy class 1.0
  • Compact 96 x 96x 55 mm DIN enclosure.
  • Bright, easy to read 7 segment LED matrix.
  • Micro-controller based.
Parameters Displayed
  • V, A, KWh, KVAh, KW, KVA, KVAR, PF, Hz.
Specifications
  • Direct Voltage Input : Up to 300V L-N Burden 0.5VA
  • Direct Voltage Input : Up to 500V L-L Burden 0.5VA
  • Secondary Current Input: 5A or 1A (To be specified at the time of Ordering)CT Primary : Site SelectableRange of Reading : 5 - 5000ABurden :< 1.0VAOverload (Through CT) : 5A CT = 6A RMS Continuous 1A CT = 1.2A RMS Continuous(Whole Current) : 120% of Imax continuous.
  • Frequency : 45 to 55 HzAccuracy : 0.3% of Reading
  • Three EnergiesRange of Reading : 0 to 9999999.9Accuracy : 1.0S as per IS 13779.
  • System PFAccuracy : 1% of Reading (IPFI>0.5)Range of Reading : 0.05 to 1.00 Lag/Lead
  • System KVA, KW & KVARAccuracy : 1.0% of Reading
  • Display : 0.56 Red Seven Seg.
  • Communication: RS485 Port with EMS / SCADA using Modbus-RTU protocol.
  • Enclosure : 96X96X55 mm
  • Micro-controller based.
View Complete Details

Apfc Relay

TRINITY has a versatile range of Power Factor Correction relays suitable for all applications. These controllers are available in economy version with minimum features, intelligent models with advance control algorithm and also sub-second switching models with solid state outputs.The entire series is economical user friendly and extremely reliable. Designs of these have been field proven for nearly fifteen years with more then 10000 units in service.
View Complete Details

Rms Type Digital Meters

  • Country of Origin India

The VAF model meters from Trinity are True RMS type digital meters for use in three phase four wire LT electrical systems. The design of these meters is based on proven micro-controller technology, resulting in compact and accurate meters. The design uses powerful micro-controller based technology. The meter uses state of the art Digital Signal Processing (DSP) circuitry to achieve very high accuracy measurement of True RMS value of all parameters. The meter displays the readings on Crisp Super bright LED Displays.

Features
  • Class 1.0 accuracy
  • Compact 96 x 96 x 55 mm DIN enclosure.
  • Ideal for supervision & audit of specific loads.
  • Micro-Controller based.
  • True RMS.
Parameters Displayed
  • V, A, Hz.

Sr. No. Parameters & Options Statistics
1. Volts R-N Direct Voltage Input : Up to 300V L-N
Burden : 0.5VA
Secondary Voltage Input : 63.5V*
2. Volts Y-N
3. Volts B-N
4. Volts RY Direct Voltage Input : Up to 500V L-L
Burden : 0.5VA
Secondary Voltage Input : 110V*
5. Volts YB
6. Volts BR
7. Current R Secondary Current Input : 5A or 1A (To be specified at thetime of Ordering)
CT- Primary : Site Selectable
Range of Reading : 5 – 5000A
Burden : < 1.0VA
Overload(Through CT) : 5A CT = 6A RMS Continuous
1A CT = 1.2A RMS Continuous
(Whole Current) : 120% of Imax continuous.
8. Current Y
9. Current B
10. Frequency 45 to 55 Hz, Accuracy : 0.3% of Reading
11. DISPLAY 0.4” Red Seven Segment.
12. Installation (a) 3P4W and 1P2W(b) 3P3W (optional)
13 Weight 0.3 kg (approx.)
14 Bezel 96x96 mm DIN enclosure
15 Depth 55 mm










View Complete Details

Powerpro

Electrical Power Meter

The Power Pro from Trinity is an easy-to-use, cost effective electrical power meter that offers all the basic measurement capabilities required to monitor an electrical installation. In addition to measuring the instantaneous parameters, it also measures accurately all three energies, and also demand, thus helping to measure and control energy costs.

Over the basic metering, it optionally provides two relay outputs, RS485 port supporting MODBUS RTU protocol, dual source metering and THD measurements.

Electrical Power Meter

The Power Pro from Trinity is an easy-to-use, cost effective electrical power meter that offers all the basic measurement capabilities required to monitor an electrical installation. In addition to measuring the instantaneous parameters, it also measures accurately all three energies, and also demand, thus helping to measure and control energy costs.

Over the basic metering, it optionally provides two relay outputs, RS485 port supporting MODBUS RTU protocol, dual source metering and THD measurements.

Parameter
Type Name Statistics
Input Supply Three Phases and Neutral of a 3P4W system / Three Phases of a 3P3W system
Voltage Direct Voltage Input : Up to 500V L-L, Up to 300V L-N
PT Ratio: Site Selectable
Burden: 0.5VA
Current Secondary Current Input: 5A or 1A (Site Selectable)
CT Ratio: Site Selectable
Range of Reading : 5 - 5000A
Burden: < 1.0V
Overload: 5A CT = 6A RMS Continuous
1A CT = 1.2A RMS Continuous
PowerSupply Auxiliary Supply: 90 - 480 VAC, 50-60 Hz.
Output Relay Two. Individually Field Programmable.
Switching Voltage: Max. 250 VAC
Switching Power : Max. 1000W
Expected Mechanical Life: >10 x 106 switching operations.
Expected Electrical Life : >4 x 106 switching operations.
@(Load = 200VA, Coscp = 0.5)
Measurment True RMSBasic Parameters Voltag(Volts L-N& L-L) VL-N - Accuracy : 0.5% of Reading
VL-L - Accuracy : 1.0% of Reading
Current(Amps IR,IY, IB) Accuracy : 0.25% of Reading
LineFrequency 45 to 55 Hz, Accuracy: 0.3% of Reading
Power ActivePower (P) Accuracy: 1% of Reading(For IPFI>0.5)
ReactivePower (Q) Accuracy: 1.5% of Reading
(Between 0.5 Lag to 0.8 Lead)
ApparentPower (S) Accuracy: 1%% of Reading
PoweFactor For Individual phases and System
Accuracy: 1.0% of Reading (IPFI20.5)
Range of Reading: 0.05 to 1.00 Lag/Lead
Energy TotalActiveEnergy(KWh) Range of Reading: 0 to 9999999.9 KWh
Accuracy: 1.0s as per IS13779
TotalApparentEnerg(KVAh) Range of Reading: 0 to 9999999.9 KWh
Accuracy: 1.0% of Reading
TotalApparentEnergy(KVARh) Range of Reading: 0 to 9999999.9 KWh
Accuracy: 1.5% of Reading
PowerQuality THD for each Voltage (Optional)
THD for each Current (Optional)
Demand KVA/ KWDemand Site Selectable. Demand Interval 15/30 Min. Also site selectable
Max.Demand Max. Value reached only. No time & date stamp
Dimensions Bezel 96 X 96 mm
Miscellaneous PanelCutout 92 X 92 mm
Depth ofinstallation 55 mm
  Display 16 X 1 Backlight LCD or 128 X 64 Graphical Backlight LCD(To be specified at the time of Ordering)
  Operatintemp 10°C to 50°C
  Weight 0.35 Kgs (Approx.)
  Min.OperatingCurrent 0.4% to 120% of CT primary
Comm. RS485 Modbus-RTU protocol



















View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

List of Other Products by Trinity Energy Systems Pvt Ltd from Vadodara, Gujarat.
Post Buy Requirement
TE

Trinity Energy Systems Pvt Ltd

Add Review

Other Products / Services

We are leaders in the market for providing best range of DIGITAL VOLTS, goblin, Empower, Apfc Relay and Rms Type Digital Meters

DIGITAL VOLTS

Features
  • Available in 1Phase2Wire, 3Phase4Wire/3Wire system
  • Accuracy: Class 1.0 & Class 0.5 (Optional)
  • 0.56" Seven Segment LED (In Volt, Amp, Freq. & 1-Phase PF Meter)
  • 16 X 1 Line LCD (In KW300 & PF300)
Specifications
  • Direct Voltage Input: 0-300V AC for P-N & 0-500V AC P-P
  • Secondary Current: 0-5000A AC
  • Frequency range: 45-55Hz
  • PF range: 0.000-1.000
  • Size:96 X 96 X 55mm
View Complete Details

Three Phase Power Analyzer

Trinity has designed its Portable Power Analyzers, ORACLE to be the most versatile instrument available today. Oracle which is, Three Phase Power Analyzer and Recorder, is our next generation analyzer, including important new features requested by our customers. From substations, to commercial & industrial, to residential monitoring, Oracle has comprehensive measurement and power quality analysis capabilities. These high performance capabilities, combined with the latest in electronic technology, make it ideal for both utility and industrial applications.
View Complete Details

Power Analyzer

Trinity has designed its Portable Power Analyzers, ORACLE to be the most versatile instrument available today. Oracle which is, Three Phase Power Analyzer and Recorder, is our next generation analyzer, including important new features requested by our customers. From substations, to commercial & industrial, to residential monitoring, Oracle has comprehensive measurement and power quality analysis capabilities. These high performance capabilities, combined with the latest in electronic technology, make it ideal for both utility and industrial applications.
View Complete Details

Maximum Demand Controllers

The digital power meter GOBLIN is a micro-controller based unit which not only measures a host of electrical parameters to display them on a 128 x 64 backlit LCD, but also acts as a comprehensive load managing device due to its four numbers of output relay contacts. These outputs are individually field programmable for both the parameter on which to generate alarm as well as the values on which to activate alarm and deactivate it. In addition to this flexibility in terms of load management, the meter also has two serial ports: USB port and RS485. RS485 supports MODBUS RTU protocol for connections to EMSSCADA. Goblin has two USB ports-one where a cable connection to laptoppc is made(Device mode) and another where the unit directly accepts a pendrive(Host mode).
View Complete Details

Goblin

The digital power meter GOBLIN is a micro-controller based unit which not only measures a host of electrical parameters to display them on a 128 x 64 backlit LCD, but also acts as a comprehensive load managing device due to its four numbers of output relay contacts. These outputs are individually field programmable for both the parameter on which to generate alarm as well as the values on which to activate alarm and deactivate it. In addition to this flexibility in terms of load management, the meter also has two serial ports: USB port and RS485. RS485 supports MODBUS RTU protocol for connections to EMS/SCADA. Goblin has two USB ports-one where a cable connection to laptop/pc is made(Device mode) and another where the unit directly accepts a pendrive(Host mode).

The unit is meant for use in three phase four wire / three wire systems. The installation type, CT ratios and PT ratios are site selectable.

The Load Manager with its four relay contacts can be used as a Demand Controller. The method of Demand calculation is sliding window and fixed window.

Features
  • Accuracy Class 0.5 (as per IS14697)
  • Displays more than 20 Parameters.
  • Four Relay contacts, individually field programmable, for alarm parameter as well as on/off values.
  • RS-485 MODBUS-RTU Connectivity.
  • Large 128 x 64 graphical LC Display.
  • USB Port for downloading data
  • Directly accepts pen-drive to transfer logged data(Host mode)
  • On board 2MB of non-volatile memory. On board data logging with field programmable log duration.
  • CT / PT ratios field programmable.
  • Odd Harmonic Analysis up to 15th for all voltages and currents, including THD.

Parameter
Type Name Statistics
Input Three Phases and Neutral of a3P4W system / Three Phases of a 3P3W system
Voltage Direct Voltage Input: Up to 500V L-L, Up to 300VL-NPT
Ratio: Site Selectable
Burden: 0.5VA
Current Secondary Current Input:5A or 1A (Site Selectable)CT
Ratio: Site Selectable
Range of Reading:5 - 5000A
Burden: < 1.0VA
Overload: 5A CT = 6A RMS Continuous
1ACT = 1.2A RMS Continuous
Power Supply Auxiliary Supply: 90 - 480VAC, 50-60 Hz.
Output Relay Four. Individually Field Programmable.
Switching Voltage: Max. 230 VAC
Switching Power: Max. 1000W
Expected Mechanical Life: >10 x 106 switching operations
Expected Electrical Life: >4 x 106 switching operations
@(Load = 200VA, Coscp = 0.5)
Measurment True RMSBasicParameters Voltage(Volts L-N & L-L) Vl-n Accuracy: 0.5% of Reading
Vl-l Accuracy : 1.0% of Reading
Current(Amps IR, IY, IB) Accuracy: 0.25% of Reading
Line Frequency 45 to 55 Hz, Accuracy: 0.3%of Reading
Power ActivePower (P) Accuracy: 0.5% of Reading(For IPFI>0.5)
ReactivePower (Q) Accuracy: 1.5% of Reading
(Between 0.5 Lag to 0.8 Lead)
ApparentPower (S) Accuracy: 0.5% of Reading
Power Factor For Individual phases andSystem.
Accuracy : 1.0% of Reading (IPFI>0.5)
Range of Reading: 0.05 to1.00 Lag/Lead
Energy Total ActiveEnergy (KWh) Range of Reading : 0 to99999999.9 KWh
Accuracy : Class 0.5 as per IS14697
Total ApparentEnergy (KVAh) Range of Reading : 0 to99999999.9 KVAh
Accuracy : Class 0.5 as per IS14697
Total ApparentEnergy (KVARh) Range of Reading : 0 to99999999.9 KVARh
Accuracy : Class 1.0
Power Quality 3rd to 15thHarmonics(Odd) for all Voltages with THD
3rd to 15thHarmonics(Odd) for all Currents with THD
Demand Active Power (KW) Demand -Sliding & Fixed, Selectable
Apparent Power (KVA) Demand -Sliding & Fixed, Selectable
 
Miscellaneous Dimensions Bezel 144 X 144 mm
Panel Cutout 138 X 138 mm
Depth of installation 55 mm
  Display 128 X 64 graphical Backlit LCD
  Operating temp 10°C to 50°C
  Weight 0.65 Kgs (Approx.)
Communication OperatingCurrent Range 0.4% to 120% of CT primary
Data LoggingBuffer 2MB, Non-volatile memory,Can hold 19691 records
Logging Duration Site selectable from 1 minute to 60 minutes
RS485 Modbus-RTU protocol
USB port and directly access pen-drive for downloading logged data



















View Complete Details

Maximum Demand Controller

To protect our entire range of products from external factors that can be damaging, we have a state-of-the-art packaging unit equipped with the latest secure packaging technologies and materials. Our organization is renowned as reliable distributor in the industry and based in the well-connected state of Gujarat(India).
View Complete Details

Empower

EMPOWER from Trinity is an electrical power meter, for use in three phase three/four wire electrical systems. It measures the phase voltages, currents, PF, Hz, system KVA, system KW, system KVAr, Active Energy (KWh) and Apparent Energy (KVAh). The various parameters measured are displayed on a 4 digit x 3 Row Red 7 segment LED matrix for easy visibility and readability. The CT ratio (primary) can be programmed at site using the front membrane key. The meter uses state of the art Digital Signal Processing (DSP) circuitry to achieve very high accuracy measurement of true RMS value of all above parameters. The meter accuracy is class 1.0 for all parameters including KWh.

Features
  • Multiparameter monitoring.
  • Measures 16 Electrical values.
  • All parameters with default accuracy class 1.0
  • Compact 96 x 96x 55 mm DIN enclosure.
  • Bright, easy to read 7 segment LED matrix.
  • Micro-controller based.
Parameters Displayed
  • V, A, KWh, KVAh, KW, KVA, KVAR, PF, Hz.
Specifications
  • Direct Voltage Input : Up to 300V L-N Burden 0.5VA
  • Direct Voltage Input : Up to 500V L-L Burden 0.5VA
  • Secondary Current Input: 5A or 1A (To be specified at the time of Ordering)CT Primary : Site SelectableRange of Reading : 5 - 5000ABurden :< 1.0VAOverload (Through CT) : 5A CT = 6A RMS Continuous 1A CT = 1.2A RMS Continuous(Whole Current) : 120% of Imax continuous.
  • Frequency : 45 to 55 HzAccuracy : 0.3% of Reading
  • Three EnergiesRange of Reading : 0 to 9999999.9Accuracy : 1.0S as per IS 13779.
  • System PFAccuracy : 1% of Reading (IPFI>0.5)Range of Reading : 0.05 to 1.00 Lag/Lead
  • System KVA, KW & KVARAccuracy : 1.0% of Reading
  • Display : 0.56 Red Seven Seg.
  • Communication: RS485 Port with EMS / SCADA using Modbus-RTU protocol.
  • Enclosure : 96X96X55 mm
  • Micro-controller based.
View Complete Details

Apfc Relay

TRINITY has a versatile range of Power Factor Correction relays suitable for all applications. These controllers are available in economy version with minimum features, intelligent models with advance control algorithm and also sub-second switching models with solid state outputs.The entire series is economical user friendly and extremely reliable. Designs of these have been field proven for nearly fifteen years with more then 10000 units in service.
View Complete Details

Rms Type Digital Meters

  • Country of Origin India

The VAF model meters from Trinity are True RMS type digital meters for use in three phase four wire LT electrical systems. The design of these meters is based on proven micro-controller technology, resulting in compact and accurate meters. The design uses powerful micro-controller based technology. The meter uses state of the art Digital Signal Processing (DSP) circuitry to achieve very high accuracy measurement of True RMS value of all parameters. The meter displays the readings on Crisp Super bright LED Displays.

Features
  • Class 1.0 accuracy
  • Compact 96 x 96 x 55 mm DIN enclosure.
  • Ideal for supervision & audit of specific loads.
  • Micro-Controller based.
  • True RMS.
Parameters Displayed
  • V, A, Hz.

Sr. No. Parameters & Options Statistics
1. Volts R-N Direct Voltage Input : Up to 300V L-N
Burden : 0.5VA
Secondary Voltage Input : 63.5V*
2. Volts Y-N
3. Volts B-N
4. Volts RY Direct Voltage Input : Up to 500V L-L
Burden : 0.5VA
Secondary Voltage Input : 110V*
5. Volts YB
6. Volts BR
7. Current R Secondary Current Input : 5A or 1A (To be specified at thetime of Ordering)
CT- Primary : Site Selectable
Range of Reading : 5 – 5000A
Burden : < 1.0VA
Overload(Through CT) : 5A CT = 6A RMS Continuous
1A CT = 1.2A RMS Continuous
(Whole Current) : 120% of Imax continuous.
8. Current Y
9. Current B
10. Frequency 45 to 55 Hz, Accuracy : 0.3% of Reading
11. DISPLAY 0.4” Red Seven Segment.
12. Installation (a) 3P4W and 1P2W(b) 3P3W (optional)
13 Weight 0.3 kg (approx.)
14 Bezel 96x96 mm DIN enclosure
15 Depth 55 mm










View Complete Details

Powerpro

Electrical Power Meter

The Power Pro from Trinity is an easy-to-use, cost effective electrical power meter that offers all the basic measurement capabilities required to monitor an electrical installation. In addition to measuring the instantaneous parameters, it also measures accurately all three energies, and also demand, thus helping to measure and control energy costs.

Over the basic metering, it optionally provides two relay outputs, RS485 port supporting MODBUS RTU protocol, dual source metering and THD measurements.

Electrical Power Meter

The Power Pro from Trinity is an easy-to-use, cost effective electrical power meter that offers all the basic measurement capabilities required to monitor an electrical installation. In addition to measuring the instantaneous parameters, it also measures accurately all three energies, and also demand, thus helping to measure and control energy costs.

Over the basic metering, it optionally provides two relay outputs, RS485 port supporting MODBUS RTU protocol, dual source metering and THD measurements.

Parameter
Type Name Statistics
Input Supply Three Phases and Neutral of a 3P4W system / Three Phases of a 3P3W system
Voltage Direct Voltage Input : Up to 500V L-L, Up to 300V L-N
PT Ratio: Site Selectable
Burden: 0.5VA
Current Secondary Current Input: 5A or 1A (Site Selectable)
CT Ratio: Site Selectable
Range of Reading : 5 - 5000A
Burden: < 1.0V
Overload: 5A CT = 6A RMS Continuous
1A CT = 1.2A RMS Continuous
PowerSupply Auxiliary Supply: 90 - 480 VAC, 50-60 Hz.
Output Relay Two. Individually Field Programmable.
Switching Voltage: Max. 250 VAC
Switching Power : Max. 1000W
Expected Mechanical Life: >10 x 106 switching operations.
Expected Electrical Life : >4 x 106 switching operations.
@(Load = 200VA, Coscp = 0.5)
Measurment True RMSBasic Parameters Voltag(Volts L-N& L-L) VL-N - Accuracy : 0.5% of Reading
VL-L - Accuracy : 1.0% of Reading
Current(Amps IR,IY, IB) Accuracy : 0.25% of Reading
LineFrequency 45 to 55 Hz, Accuracy: 0.3% of Reading
Power ActivePower (P) Accuracy: 1% of Reading(For IPFI>0.5)
ReactivePower (Q) Accuracy: 1.5% of Reading
(Between 0.5 Lag to 0.8 Lead)
ApparentPower (S) Accuracy: 1%% of Reading
PoweFactor For Individual phases and System
Accuracy: 1.0% of Reading (IPFI20.5)
Range of Reading: 0.05 to 1.00 Lag/Lead
Energy TotalActiveEnergy(KWh) Range of Reading: 0 to 9999999.9 KWh
Accuracy: 1.0s as per IS13779
TotalApparentEnerg(KVAh) Range of Reading: 0 to 9999999.9 KWh
Accuracy: 1.0% of Reading
TotalApparentEnergy(KVARh) Range of Reading: 0 to 9999999.9 KWh
Accuracy: 1.5% of Reading
PowerQuality THD for each Voltage (Optional)
THD for each Current (Optional)
Demand KVA/ KWDemand Site Selectable. Demand Interval 15/30 Min. Also site selectable
Max.Demand Max. Value reached only. No time & date stamp
Dimensions Bezel 96 X 96 mm
Miscellaneous PanelCutout 92 X 92 mm
Depth ofinstallation 55 mm
  Display 16 X 1 Backlight LCD or 128 X 64 Graphical Backlight LCD(To be specified at the time of Ordering)
  Operatintemp 10°C to 50°C
  Weight 0.35 Kgs (Approx.)
  Min.OperatingCurrent 0.4% to 120% of CT primary
Comm. RS485 Modbus-RTU protocol



















View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us