Post Buy Requirement
TP
Pune, Maharashtra, India
Add Review

Our Product / Services

  1. Filters 5 Products available
  2. Capacitor 5 Products available
  3. Control Panels 3 Products available
  4. Transformers And Transformer Parts

    2 Products available
  5. Process Control Systems & Equipment

    2 Products available
  6. Switchgear Panels

    2 Products available
  7. Electrical Panels & Distribution Box

    2 Products available
  8. Corporate Finance & Accounting Services

    1 Services available
  9. Voltage Stabilizers & Power Controllers

    1 Products available
  10. Electric Circuit Components & Parts

    1 Products available
  11. Others Products / Services 5 Products / Services available

Other Products / Services #4494421

Our Complete range of products are HT Iron Core Reactors, HT HARMONIC FILTER BANK DETUNED & TUNED, Apfc Relay, 3-Phase Load Reactor and HT Harmonic Filter Bank Detuned.

HT APFC PANEL Home HT APFC Panel

  • Specifications: Specifications: 50/60Hz , Rating : 500 to 5000Kvar , Voltage : 3.3/3.6/6.6/11/22/33 KV and Application : Pf improvement/Harmonic
APFC Panel is an integration of CRCA powder coated MS Sheet enclosure, fully wired with self healing HT capacitor, Vacuum contactor, fan, APFCR, all switchgears, with IP protection, busbar ALCU, with IEC STD.
View Complete Details

Ht Panel

Our reactor windings consist of numerous aluminum or copper conductors connected in parallel.These conductors can be insulated single wires, insulated cables or alumininum profiles separated by fiberglass spacers. The cost-effective Solution to be selected, in terms of dimensions and conductor type to be used in each design, depends on the required ratings for the equipment.For encapsulated design, the conductors are mechanically immobilized and Encapsulated by epoxy impregnated fiberglass filaments forming cylinders.Depending on the reactor ratings, one or more of these cylinders are connected in parallel between aluminum or copper spiders. The individual cylinders are separated by fiberglass spacers forming cooling Ducts. F+155 C & H-180 C Class.
View Complete Details

RTPFC Panel

  • Specifications: Rating : 50.4000Kvar , Voltage : 400/440/480/525/690/800V , Mode of Switching : Static and Application : Pf Improvement for dynamic load/ Harmonic Reduction
T-RTPFC panel is an integration of CRCA powder coated MS Sheet enclosure , fully wired with Self healing MPP capacitor & Reactor , capacitor duty Thyristor, fan, APFCR, all switchgears, with IP protection , busbar ALCU, with IEC STD, a) The thyristor switched contactor shall be capable of handling the continuous current of 130% of the rated capacitor current at rated voltage of 415V. The blocking voltage of the thyristor switch during off Condition should be minimum 1800 Volt peak. Every thyristor switch should be capable of handling the dvdt of 2000 Volts S. b) The thyristor switched contactor used shall turn on at zero differential voltage across it. This zero differential voltage tolerance shall not exceed 6 Volts peak value around zero. c) The time delay between turn off and subsequent turn on should be as minimum as possible and in the range of milliseconds. There should not be any discharge devices across capacitor that can exceed the watt loss of more than 30 watt.
View Complete Details

Power Quality Audit

We are considered a renowned name in the industry that provides power quality analysis services. Our reliable services are suitable for efficient mains monitoring & analysis and include support for unbalance v, I & w, transient inrush current and panel mounted display meter. Provided at affordable rates, our services are also demanded in electrical, automotive & steel industries and sugar factories.
View Complete Details

3-PHASE LOAD REACTORS

  • Specifications: Motor power : 1.5 to 630 kW , Rated current : 4 to 1100 A , Switching frequency: 2 to 16 kHz and Voltage: up to 500 VAC
1)dvdt voltage suppression2)Reduces motor winding insulation stress when short motor cables are used.
View Complete Details

HT Iron Core Reactors

Our filter reactors are made of high-class transformer sheets and copper wire or aluminum band.they are dried and impregnated in vacuum with environment friendly low-styrole resin which ensures they can withstand high voltages. Have low noise levels, and offer a long operating life.depending on their rated power, the reactors are provided with either terminal blocks or terminal lugscables.the connection of the aluminium reactors is made through copper terminals as well, which are reliably connected with the aluminium band by a special, well-proven welding method.
View Complete Details

HT Air Core Reactors

Our reactor windings consist of numerous aluminum or copper conductors connected in parallel.These conductors can be insulated single wires, insulated cables or alumininum profiles separated by fiberglass spacers. The cost-effective Solution to be selected, in terms of dimensions and conductor type to be used in each design, depends on the required ratings for the equipment.For encapsulated design, the conductors are mechanically immobilized and Encapsulated by epoxy impregnated fiberglass filaments forming cylinders.Depending on the reactor ratings, one or more of these cylinders are connected in parallel between aluminum or copper spiders. The individual cylinders are separated by fiberglass spacers forming cooling Ducts. F+155 C & H-180 C Class.
View Complete Details

APFC Panel

  • Specifications: Rating : 50, 4000Kvar Regler, Voltage : 400, 415, 440, 525, 690, 800, 1200V and Application : PF improvement
APFC panel is a system integrated with CRCA sheet enclosure with powder coated, fully wired with self healing MPP capacitors, capacitor duty contactors, capacitor fan, APFCR, all switchgears, with IP protection, busbar - ALCU with IEC STD.
View Complete Details

JANITZA RELAY

  • Features: Consistent operation , Ruggedly constructed and Minimal maintenance required
We are among the favored choice of our esteemed customers, which engage in the manufacture, import, export and supply of Energy Management Systems. Owing to the reliable performance, the proposed assemblage is widely used for monitoring energy in the industrial plants. Clients can obtain the assortment in numerous specifications.
View Complete Details

LT REACTORS

  • Specifications: Specification : 50/60Hz Rating : 12.5/25/50/75/100/150 Kvar
Our filter reactors are made of high-class transformer sheets and copper wire or aluminum band.They are dried and impregnated in vacuum with evironment friendly low-styrole resin which ensures they can withstand high voltages. have low noise levels, and offer a long operating life.Depending on their rated power, the reactors are provided with either terminal blocks or terminal lugscables.The connection of the aluminium reactors is made through copper terminals as well, which are reliably connected with the aluminium band by a special, well-proven welding method.
View Complete Details

HT HARMONIC FILTER BANK DETUNED & TUNED

  • Specifications: Specifications: 50/60Hz , Rating : 500.6000Kvar , Voltage : 3.3/6.6/11/22/33 Kv , Mode of Switching : VCB and Application : PF Improvement / Harmonic Reduction
T -HTF bank comprises of HT capacitor and HT reactor assembled in a single star or Double star with protection NCTRVT along with protection relay.
View Complete Details

Automatic Power Factor Regulator

  • Specifications: Rating : 4/6/12 , Voltage : 90 to 550 V and Application : Contactor / Static
The PFR-X power factor controller calculates the active and reactive power in the mains from the measured current and voltage.The intelligent control algorithm optimizes the switching sequences and guarantees for short regulation times with minimum number of switchings.At the same time, switching operations are equally shared among the available capacitor branches where possible.The integrated connection control immediately detects in which phase voltage and current are measured, and adapts the entire system automatically.The very low current threshold of 10mA allow for very reliable and exact PF control.1A as well as 5A current transform can be used without additional manual adjustments.The power supply cover a voltage range of 90.550V.
View Complete Details

PFR-T Power Factor Controllers

  • Specifications: Rating : 4/6/12 , Voltage : 90 to 550 V and Application : Thyristor/Static
The PFR-T power factor controller calculates the active and reactive power in the mains from the measured current and voltage.The intelligent control algorithm optimizes the switching sequences and guarantees for short regulation times with minimum number of switchings.At the same time, switching operations are equally shared among the available capacitor branches where possible.The integrated connection control immediately detects in which phase voltage and current are measured, and adapts the entire system automatically.The very low current threshold of 10mA allow for very reliable and exact PF control.1A as well as 5A current transform can be used without additional manual adjustments.The power supply cover a voltage range of 90.550V.
View Complete Details

Apfc Relay

The PFR-X power factor controller calculates the active and reactive power in the mains from the measured current and voltage.The intelligent control algorithm optimizes the switching sequences and guarantees for short regulation times with minimum number of switchings.At the same time, switching operations are equally shared among the available capacitor branches where possible.The integrated connection control immediately detects in which phase voltage and current are measured, and adapts the entire system automatically.The very low current threshold of 10mA allow for very reliable and exact PF control.1A as well as 5A current transform can be used without additional manual adjustments.The power supply cover a voltage range of 90.550V.
View Complete Details

Power Factor Controller

The PFR-T power factor controller calculates the active and reactive power in the mains from the measured current and voltage.The intelligent control algorithm optimizes the switching sequences and guarantees for short regulation times with minimum number of switchings.At the same time, switching operations are equally shared among the available capacitor branches where possible.The integrated connection control immediately detects in which phase voltage and current are measured, and adapts the entire system automatically.The very low current threshold of 10mA allow for very reliable and exact PF control.1A as well as 5A current transform can be used without additional manual adjustments.The power supply cover a voltage range of 90.550V.
View Complete Details

Capacitor Duty Contactor

  • Specifications Specifications : 50/60Hz , Rating : 12.5/20/25/33.3/50/75/80/100 Kvar , Voltage : 400/415 V and Application : PF improvement/Harmonic Filter
Design Magnetic, three phase, with pre-load contacts for inrush protection Voltage range Umains = 400.440V (other voltages available on request) Control Voltage 220.240V (Other voltage available on request) Mounting DIN hat rail W x H = 35 x 7.5mm or base mounting lugs for 5mm screw Snap-on auxiliary contacts available on request IEC947-4-1. EN60947-4-1, VDE0660 Standards
View Complete Details
Tell Us What are you looking for? Will call you back