Leading Manufacturer, Supplier & Retailer of Three Pass Oil Fired.

THERMIC FLUID PUMP / CHEMICAL PROCESS PUMP

Our range of Pumps is manufactured by adopting latest technological development. Engineered to meet the perfection these are designed with utmost care and assure longevity .Further its compact & light-weight structure allows it to be easily placed inside original equipment.

View Complete Details

Electric Blowers

We offer technically advanced blower, which are used for effective air controlling. Our range of blowers is offered in various specifications in order to meet the varied requirements of the industries. Providing effectively and economical solution, these blowers are available in low, medium & high pressure operation.These blowers can be supplied with any type of outlet direction of rotation and discharge designed to the specific requirements of our customers.

View Complete Details

Thermic Fluid Oil

This system is forced circulation fully automatic thermic fluid heater where thermic fluid is circulated in a closed loop through heater and user equipment circuit where the heat is dissipated to process. The same thermic fluid is re-circulated through heater for heating. The thermic fluid heater gives high temperature upto 300 oC using thermic fluid oil at near atmospheric pressure as compared to steam heating which requires 85 KgCm2 pressure.
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • Mr. Haresh M. Patel (Thermoenergy System)
  • Plot No. 1713, Phase -III , G.I.D.C. Vatva, Opp. N.K.P. Pharma, B/h Rudrax Weighbridge, Nr. Tikampura Patiya, Vatva, Ahmedabad - 382445, Gujarat ( I, India
  • Share us via
List of Other Products by Thermoenergy System from Ahmedabad, Gujarat.
Post Buy Requirement

Other Products / Services

We are leaders in the market for providing best range of Three Pass Oil Fired

THERMIC FLUID PUMP / CHEMICAL PROCESS PUMP

Our range of Pumps is manufactured by adopting latest technological development. Engineered to meet the perfection these are designed with utmost care and assure longevity .Further its compact & light-weight structure allows it to be easily placed inside original equipment.

View Complete Details

Hot Air Generator

Model Unit HAG-10 HAG-20 HAG-40
Heat output Kcal/Hr. 1, 00, 000 2, 00, 000 4, 00, 000
Hot air output at 200oc M3/Hr 2, 500 3, 500 4, 000
Maximum hot air temperature C 250 250 250
Efficiency on gcv % 85 85 85
Fuel oil consumption LDO.Kg/Hr. 10.8 21.5 43.0
Connected electric load HP 6.5 9.0 11.5
Burner modulation ---- ON-OFF ON-OFF ON-OFF
LDO GCV 10700 KCAL / KG.
F.O. GCV 10200 KCAL / KG.
View Complete Details

HIGH EFFICIENTY MULTI FUEL THERMIC FLUID HEATER

The new vertical three pass thermic fluid heater is suitable for Process industries in rapidly changing and undependable energy situations. It gives you an assurance for rated output on any solid fuel like coal, Lignite, wood, husk, bagasse etc.

Parameter Unit Model
TFHV-400 TFHV-600 TFHV-1000 TFHV-1500 TFHV-2000
Heat Output Kcal/Hr 4,00,000 6,00,000 10,00,000 15,00,000 20,00,000
Max.Fluid Outlet Temperature oC 300
Max. Head at heater Outlet M/c 27
Efficiency on GCV Steam Coal % 76
Agro-waste % 70
Rated fuel consumption Steam Coal Kg/hr 116 175 290 435 580
Lignite Kg/hr 150 226 376 564 752
Agro-waste Kg/hr 174 260 433 650 866
Thermic Fluid Pump Motor Kw 7.5 9.3 11.0 18.5 30
I.D.Fan Motor Kw 3.7 5.5 9.3 11.0 15.0
F.D.Fan Motor Steam Coal Kw - 1.5 2.2 3.7 5.5
Agro-waste Kw - 2.2 3.7 5.5 7.5
Total Load Steam Coal Kw 11.2 16.3 22.5 33.2 50.0
Agro-waste Kw - 17.0 24.0 35.0 52.5
Expansion Tank Capacity Liters 800 800 1000 1000 1250
View Complete Details

HIGH EFFCIENTY THREE PASS THERMIC FLUID HEATER

The new vertical three pass thermic fluid heater is suitable for Process industries in rapidly changing and undependable energy situations. It gives you an assurance for rated output on any solid fuel like coal, Lignite, wood, husk, bagasse etc.

Parameter Unit Model
TFHV-400 TFHV-600 TFHV-1000 TFHV-1500 TFHV-2000
Heat Output Kcal/Hr 4,00,000 6,00,000 10,00,000 15,00,000 20,00,000
Max.Fluid Outlet Temperature oC 300
Max. Head at heater Outlet M/c 27
Efficiency on GCV Steam Coal % 76
Agro-waste % 70
Rated fuel consumption Steam Coal Kg/hr 116 175 290 435 580
Lignite Kg/hr 150 226 376 564 752
Agro-waste Kg/hr 174 260 433 650 866
Thermic Fluid Pump Motor Kw 7.5 9.3 11.0 18.5 30
I.D.Fan Motor Kw 3.7 5.5 9.3 11.0 15.0
F.D.Fan Motor Steam Coal Kw - 1.5 2.2 3.7 5.5
Agro-waste Kw - 2.2 3.7 5.5 7.5
Total Load Steam Coal Kw 11.2 16.3 22.5 33.2 50.0
Agro-waste Kw - 17.0 24.0 35.0 52.5
Expansion Tank Capacity Liters 800 800 1000 1000 1250
View Complete Details

Coal Fire Hot Air Generator

OHot Air Generators are tailor-made to suit individual requirements. The units are self contained, ready to install immediately after power supply is given. Fresh air from atmosphere is fed onto the surface of combustion chamber through a statically & dynamically balance blower. The shape of passage form an envelope on the combustion chamber to extract maximum heat, thus creating efficient higher heat transfer The air continues to pass through outer surface of heat exchanger, gaining heat which is collected at the other end of hot air generator. Generation of hot air is achieved within minutes of its start

View Complete Details

Thermic Fluid Heaters

This system is forced circulation fully automatic thermic fluid heater where thermic fluid is circulated in a closed loop through heater and user equipment circuit where the heat is dissipated to process. The same thermic fluid is re-circulated through heater for heating. The thermic fluid heater gives high temperature upto 300 oC using thermic fluid oil at near atmospheric pressure as compared to steam heating which requires 85 Kg/Cm2 pressure.

FEATURES

MULTIFUEL CONCEPT

Guaranted output on low grade coal and lignite with GCV upto 3800 Kcal/Kg. Agricultural Wastes such as rice Husk, Bagasse, Groundnut shell, Saw Dust etc.

HIGHEST EFFICIENCY

The combustion chamber dimension and grate area are suitably designed for maximum combustion efficiency on low grade fuel. This system is easily accessible and large heating surface of Thermo Energy Systems heater and air pre-heater assures on unmatched efficiency f 76% (on GCV of coal having 5000 Kcal/Kg.)

LOW POWER CONSUMPTION

Unique design of Thermo Energy Systems heater ensures lowest power consumption over any other competing system available today.

ABSOLUTE SAFETY

External Combustion chamber ensures longer life of heater coil and thermic fluid. No radiation energy is transferred to heater coil in case of power failure ensuring complete safety. Diesel engine driven pump is not required for Fluid tech heater as compared to vertical systems.

EXTERNAL FURNACE

Coal/Lignite is burnt in an external furnace which results in an elimination of any possible hazard to the thermic fluid heater coil. A flue by-pass system is attached for the protection against power failure. The entire furnace is provided with steel casing and the combustion chamber is constructed with best quality high heat duty fire bricks and insulation bricks. Mineral wool insulating panels help minimum heat loss.

THERMIC FLUID HEATER

Here a nest of concentric helical tube coils is placed within sturdy mild steel shell. The special arrangement of concentric coils ensures optimum heat transfer. The system along with the standard accessories is conveniently mounted on the sturdy steel skid for easy installation.

SAFETY CONTROLES AND INSTRUMENTATION

Digital Electronic indicator cum controller forward/return temperature for ID fan off.Electronic stack temperature controller shuts of the unit in case of abnormally low temperature.Electronic low level controller in expansion cum deareated tank shuts off the unit in case of low thermic fluid level in tank.Electronic forward high temperature safety controllers shuts off the unit case forward temperature exceeds than minimum recommended temperature.Differential pressure switch shuts of in case of abnormal fluid flow conditions.Pressure gauge for inlet pressure measurement.Pressure gauge for circuit pressure measurement.Audio visual alarm for abnormal operating conditions.

OPTIONAL FEATURES

Coal cum oil firing system to change over from one fuel to another with minimum down time, Automatic by-pass damper with electromagnetic or pneumatic device.Modulating damper or variable speed drive to control combustion under all operating conditions.

 

Parameter Unit Model
TFHV-400 TFHV-600 TFHV-1000 TFHV-1500 TFHV-2000
Heat Output Kcal/Hr 4,00,000 6,00,000 10,00,000 15,00,000 20,00,000
Max.Fluid Outlet Temperature oC 300
Max. Head at heater Outlet M/c 27
Efficiency on GCV With APH+ % 75
Without APH+ % 70
Rated fuel consumption Steam Coal Kg/hr 116 175 290 435 580
Lignite Kg/hr 150 226 376 564 752
Agro-waste Kg/hr 174 260 433 650 866
Thermic Fluid Pump Motor Kw 7.5 9.30 11.0 18.5 30
I.D.Fan Motor Kw 3.7 5.5 9.3 11.0 15.0
Over fire fan motor Kw - 1.50 2.20 3.70 5.50
Total Load Kw 11.20 16.30 22.50 33.20 50.70
Expansion Tank Capacity Liters 800 800 1000 1000 1250
Overall Dimensions Length mm 4600 6000 7500 7800 10000
With mm 3800 4000 4500 5400 6200
View Complete Details

Hot Water Generator

PRODUCTSPECIFICATION

The RHB is a vertical shell type, two pass design hot water generator.

The combustion chamber is enclosed by a water jacket. An air jacket encloses the water jacket. The air blower is attached at the bottom. Air is preheated before it enters the combustion chamber, thus increasing efficiency.

Capacities available are from 20, 000 Kcals/hr to 1, 50, 000 Kcals/hr. Standard models are available in light oil firing with the rugged Ross burner. Gas fired units are also available. Outlet temperature normally is 95 C.

Due to the shell type design, unit is ideally suited for higher water flow rates. Being very easy to run & maintain, it is one of the most popular designs in the market today.

View Complete Details

Electric Blowers

We offer technically advanced blower, which are used for effective air controlling. Our range of blowers is offered in various specifications in order to meet the varied requirements of the industries. Providing effectively and economical solution, these blowers are available in low, medium & high pressure operation.These blowers can be supplied with any type of outlet direction of rotation and discharge designed to the specific requirements of our customers.

View Complete Details

Thermic Fluid Oil

This system is forced circulation fully automatic thermic fluid heater where thermic fluid is circulated in a closed loop through heater and user equipment circuit where the heat is dissipated to process. The same thermic fluid is re-circulated through heater for heating. The thermic fluid heater gives high temperature upto 300 oC using thermic fluid oil at near atmospheric pressure as compared to steam heating which requires 85 KgCm2 pressure.
View Complete Details