Calibrators

We offer the best product range of CALsys C-4004 High Accuracy Temperature Indicator, LBB33DCH Differential Extended Area Black Body, LBB11DCH Differential Extended Area Black Body, LBB11H Extended Area Black Body and LBB22H Extended Area Black Body.

CALsys C-4004 High Accuracy Temperature Indicator

  • Min. Order (MOQ) 1 Piece(s)
  • Display 192x64 LCD Graphic Panel with backlight
  • Input 2 Channel for RTD and Thermocouple via lemo 1- S series connector
  • Dimensions 224(H)x318(W)x9(D)mm
  • Working Temperature Less than 95% non condensing condition
  • Storage Temperature -20 to +55 °C
  • Mains Supply 85-264 VAC / 120-370 VDC 47-63 Hz
  • Data Logging Up to 4000 single channel Values can be stored along with date and time

CALsys C-4004 is fully characterized for all major sensors (thermocouples such as B, C, D, E, J, K, N, R, S, T and RTD's like PT-100, PT-50, PT-10, PT-200, PT-500, and PT-1000). The instrument can be used in industries where high accuracy temperature measurement is essential. Two-channel input provides A, B & A-B measurement on the LCD display. The device is providing exceptionally stable cold junction compensation.
CalsysC-4004 comes with front panel keys for easy operations like Unit selection, Resolution and Data logging. There are four input ports, two for thermocouple and two for RTD. In order to measure temperature suitable probe should be connected to TC & RTD input. The temperature measured by the device will be displayed in bigger fonts and the actual resistance (ohms) in case of RTD and voltage (mV) in case of Thermocouple will be displayed in smaller fonts. All channel details and configuration will be displayed on the LCD display.

Key Features:

  • High stability
  • High accuracy of RTD measurement 0.01°C
  • High accuracy of T/C measurement 0.1°C
  • High Resolution
  • Measuring inputs
  • 10 Thermocouples B, C, D, E, R, S, T, N, J, K
  • 6 RTD's PT-100, PT-10, PT-50, PT-500, PT-200, PT- 1000
  • Thermocouple reference junction external, internal and off
  • Units °C/ °F
  • Data Logging up to 4000 values
  • Suitable for 2/3/4 wire RTD

Additional Information:

Payment Terms : T/T

Packaging Details : Suitable Rugged Packing Case

Delivery Time : 6-8 Weeks

Technical Specifications

Display 192x64 LCD Graphic Panel with back light
Inputs 2 Channels for RTD and Thermocouple via lemo 1-S series connector
Reference Junction Reference Junction compensation may be selected for the following modes :
Automatic:Internal reference junction range 0 to +100 °
External:Via Pt 100 sensor connected to channel A and B range to 0 to +100 °C
Off:Turns the Reference Junction OFF = 0° C
Working Temperature 0....50°C rel. humidity Less than 90% non condensing condition
Storage Temperature -20 to +55 °C
Mains Supply 85-264 VAC / 120-370 VDC 47-63 Hz
Data Logging Up to 1800 values can be stored along with date and time
Dimensions 224 x 318 x 90



Input Sensor Range

Thermocouple Sensor Type Temperature Range Resolution Accuracy @ 20±5°C
Type K Thermocouple -200°C to 1372°C 0.01 ±(0.01°C + 0.006% FS
Type J Thermocouple -210°C to 1200°C 0.01 ±(0.008°C + 0.005% FS)
Type E Thermocouple -200°C to 1000°C 0.01 ±(0.01°C + 0.004% FS)
Type N Thermocouple -200°C to 1300°C 0.01 ±(0.01°C + 0.005% FS )
Type R Thermocouple 0°C to 1768°C 0.01 ±(0.005°C + 0.015% FS)
Type S Thermocouple 0°C to 1768°C 0.01 ±(0.005°C + 0.015% FS)
Type B Thermocouple 400°C to 1820°C 0.01 ±(0.02°C + 0.006% FS)
Type T Thermocouple -250°C to 400°C 0.01 ±(0.005°C + 0.015% FS)
Type C Thermocouple 0°C to 2315°C 0.01 ±(0.075°C + 0.005% FS)
Type D Thermocouple 0°C to 2315°C 0.01 ±(0.075°C + 0.005% FS)
Rtd Sensor Type Temperature Range Resolution Accuracy @ 20±5°C
PT-100 -200°C to -100°C 0.001 0.02°C
PT-100 -100°C to +500°C 0.001 0.01°C
PT-100 +500°C to +800°C 0.001 0.02°C
PT-10 -200°C to +800°C 0.001 0.02°C
PT-50 -200°C to +800°C 0.001 0.02°C
PT-200 -200°C to +800°C 0.001 0.02°C
PT-500 -200°C to +800°C 0.001 0.02°C
PT-1000 -200°C to +800°C 0.001 0.02°C
View Complete Details

LBB33DCH Differential Extended Area Black Body

  • Weight 30 kg
  • Power Supply 230 VAC, 1 ph. 50 Hz
  • Standard CE Certified
  • Emissive area 300 x 300 mm²
  • Absolute Temperature Range 10°C to 80°C
  • Differential Temperature Range (Ambient 25°C) -15°C to 55°C
  • Emissive area uniformity (1 & 2)* ±0.20°C @50°C
  • Emissivity 0.98±0.02
  • Stability ±0.01°C
  • Temperature Measurement Accuracy ±0.1°C
  • Display 5” LCD °C or °F user selectable
  • Controller Dimension 100(H) x 120(W) x 300(D) mm
  • Display resolution 0.01°C
  • Method of control Digital self tuned PID Controller
  • Head dimensions W x H x D (mm³) 500 X 500 X 200 mm
  • Max. power consumption 2.5 K W
  • Remote control Ethernet, Rs-232
  • Operating Temperature Range (head) 5°C to 25°C

Extended area black body is defined by the large emitting surface area precise temperature control with good uniformity. Tempsens make Blackbodies are state of the art, highly accurate and stable with different standard sizes and temperature ranges. The LBBDCH Series Extended Area black bodies are low-temperature infrared reference sources operating either in absolute or differential mode. This Black body series featuring very high stability, they are particularly well adapted for the characterization and performance validation of a very wide range of IR Sensors, such as high-resolution cameras for thermography and long-range thermal imagers. Essentially the black body emits a known amount of energy for an infinite number of wavelengths. This enables to draw the expected black body radiation curve for a given temperature. Temperature is accurately controlled by High accurate PID self-tuning controller.
With the Tempsens make Compact Extended Area Black body Temperature Calibrator, you have chosen an extremely effective instrument which we hope will live up to all your expectations. This is a fast, time-saving, and reliable true industrial temperature calibrator designed for on-site use.
During the past several years, we have acquired extensive knowledge of industrial temperature calibration. This expertise is reflected in our products which are all designed for daily use in an industrial environment.

Key Features:

  • Independent Controller with Real-time display and Calibration data.
  • Quick and convenient calibration technique.
  • Serial communication and computer interfacing by RS-232 Port.
  • Absolute temperature Range 10°C to 80°C.
  • Large Emmisive areas .
  • Differential and Absolute modes of operation.
  • High thermal uniformity and emissivity.
  • Portable controller.
View Complete Details

LBB11DCH Differential Extended Area Black Body

  • Weight 15 kg
  • Power Supply 230 VAC, 1 ph. 50 Hz
  • Emissive area 100 x 100 mm²
  • Absolute Temperature Range 0°C to 115°C
  • Differential Temperature Range (Ambient 25°C) -25°C to 90°C
  • Emissive area uniformity (1 & 2)* ±0.20°C @50°C
  • Emissivity 0.98±0.02
  • Stability ±0.01°C
  • Temperature measurement Accuracy ±0.1°C
  • Display 5” LCD °C or °F user selectable
  • Controller Dimension 100(H) x 120(W) x 300(D) mm
  • Display Resolution 0.01°C
  • Method of control Digital self tuned PID Controller
  • Head dimensions W x H x D (mm³) 300 X 320X 190 mm
  • Max. Power Consumption 1 K W
  • Remote Control Ethernet, RS-232
  • Operating Temperature Range(head) 5°C to 25°C

Extended area black body is defined by the large emitting surface area precise temperature control with good uniformity. Tempsens make Blackbodies are state of the art, highly accurate and stable with different standard sizes and temperature ranges. The LBBDCH Series Extended Area black bodies are low-temperature infrared reference sources operating either in absolute or differential mode. This Black body series featuring very high stability, they are particularly well adapted for the characterization and performance validation of a very wide range of IR Sensors, such as high-resolution cameras for thermography and long-range thermal imagers. Essentially the black body emits a known amount of energy for an infinite number of wavelengths. This enables to draw the expected black body radiation curve for a given temperature. Temperature is accurately controlled by High accurate PID self-tuning controller.
With the Tempsens make Compact Extended Area Black body Temperature Calibrator, you have chosen an extremely effective instrument which we hope will live up to all your expectations. This is a fast, time-saving, and reliable true industrial temperature calibrator designed for on-site use.
During the past several years, we have acquired extensive knowledge of industrial temperature calibration. This expertise is reflected in our products which are all designed for daily use in an industrial environment.

Key Features:

  • Independent Controller with Real-time display and Calibration data.
  • Quick and convenient calibration technique.
  • Serial communication and computer interfacing by RS-232 Port.
  • Absolute temperature Range 0°C to 115°C.
  • Large Emmisive areas.
  • Differential and Absolute modes of operation.
  • High thermal uniformity and emissivity.
  • Portable controller.
View Complete Details

LBB11H Extended Area Black Body

  • Accuracy ±0.5°C
  • Power Supply 230 VAC, 1 ph. 50 Hz
  • Temperature Range from 50 °C to 500 °C
  • Exceptionally High Emissivity of 0.98 ± 0.02
  • Standard CE Certified
  • Emissive Area 100 x 100 mm²
  • Emissive area uniformity ±2 at 400 °C
  • Emissivity 0.98±0.02
  • Stability ±0.1°C
  • Display resolution 0.1°C
  • Warm-up time 30 min
  • Head dimensions W x H x D (mm³) 300 x 320 x 190 mm
  • Remote control Ethernet, RS-232

Extended area Black body is defined by the large emitting surface area precise temperature control with good uniformity. The blackbody is designed to provide infrared radiation as an ideal blackbody emitter. Because of the large uniform surface area the body called extended area black body.
We separately provide high accurate programmable controller with black body source. High-accuracy chambers have been designed separately. The temperature of the furnace is set or changes by the controller.

Key Features:

  • Remote control via Ethernet link, RS-232
  • Very High Stability and accuracy
  • Real-time display of surface and setpoint temperature
  • Large emissive area with high uniformity
View Complete Details

LBB22H Extended Area Black Body

  • Accuracy ±0.5°C
  • Power Supply 230 VAC, 1 ph. 50 Hz
  • Temperature Range from 50°C to 500 °C
  • Exceptionally High Emissivity of 0.98 ± 0.02
  • Standard CE Certified
  • Emissive Area 200 x 200 mm²
  • Emissive area uniformity ±3 at 400 °C
  • Emissivity 0.98±0.02
  • Stability ±0.1°C
  • Display resolution 0.1°C
  • Warm-up time 45 min
  • Head dimensions W x H x D (mm³) 550 x 550 x 260 mm
  • Remote Control Ethernet, RS-232

Extended area Black body is defined by the large emitting surface area precise temperature control with good uniformity. The blackbody is designed to provide infrared radiation as an ideal blackbody emitter. Because of the large uniform surface area the body called extended area black body.
We separately provide high accurate programmable controller with black body source. High-accuracy chambers have designed separately. The temperature of furnace is set or changes by the controller.

Key Features:

  • Remote control via Ethernet link, RS-232
  • Very High Stability and accuracy
  • Real-time display of surface and setpoint temperature
  • Large emissive area with high uniformity
View Complete Details

LBB22CH Extended Area Black Body

2.55 Lakh /Piece Get Latest Price
  • Weight 25 kg
  • Power Supply 230 VAC, 1 ph. 50 Hz
  • Emissive Area 200 x 200 mm²
  • Temperature range (Standard) 10°C to 110°C
  • Temperature range (Optional) 0°C to 110°C
  • Emissive area uniformity (1) ±0.20°C @50°C
  • Emissivity 0.98±(0.02)
  • Stability ±0.01°C
  • Temperature Measurement Accuracy ±0.3°C
  • Display resolution 0.01°C
  • Method of control Digital self tuned PID Controller
  • Head dimensions W x H x D (mm³) 550 x 550 x 260 mm
  • Max. Power Consumption 1.5 K W
  • Remote Control Ethernet, RS-232
  • Operating temperature range (head) 5°C to +25°C

Extended area black body is defined by the large emitting surface area precise temperature control with good uniformity. Tempsens make Blackbodies are state of the art, highly accurate, and stable with different standard sizes and temperature ranges. The LBBCH Series Extended Area blackbodies are low-temperature infrared reference sources operating either in absolute or differential mode.
This Blackbody series featuring very high stability, they are particularly well adapted for the characterization and performance validation of a very wide range of IR Sensors, such as high-resolution cameras for Thermography and long-range thermal imagers. Essentially the black body emits a known amount of energy for an infinite number ofwavelengths. This enables us to draw the expected black body radiation curve for a given temperature. Temperature is accurately controlled by High accurate PID self-tuning controller.
With the Tempsens make Compact Extended Area Black body Temperature Calibrator, you have chosen an extremely effective instrument that we hope will live up to all your expectations. This is a fast, time-saving, and reliable true industrial temperature calibrator designed for on-site use.During the past several years, we have acquired extensive knowledge of industrial temperature calibration. This expertise is reflected in our products which are all designed for daily use in an industrial environment.

Key Features:

  • Independent Controller with Real-time display and Calibration data.
  • Quick and convenient calibration technique.
  • Serial communication and computer interfacing by RS-232 Port.
  • Absolute temperature Range 0°C to 110°C.
  • Differential and Absolute modes of operation.
  • High thermal uniformity and emissivity.
  • Portable controller.
  • For Optional model (Temperature Range 0°C to 110°C) with Nitrogen Purging facility, the price will be 15% extra.
View Complete Details

LBB33H Extended Area Black Body

  • Accuracy ±0.5°C
  • Power Supply 230 VAC, 1 ph. 50 Hz
  • Temperature range from 50 °C to 500 °C
  • Exceptionally high emissivity of 0.98 ± 0.02
  • Emissive Area 300 x 300 mm²
  • Emissive Area Uniformity ±3 at 400 °C
  • Emissivity 0.98±0.02
  • Stability ±0.1°C
  • Display Resolution 0.1°C
  • Warm-up Time 60 min
  • Head Dimensions W X H X D (mm³) 550 X 550 X 260 Mm
  • Remote Control Ethernet, RS-232

Extended area Black body is defined by the large emitting surface area precise temperature control with good uniformity. The blackbody is designed to provide infrared radiation as an ideal blackbody emitter. Because of the large uniform surface area the body called extended area black body.
We separately provide high accurate programmable controller with black body source. High-accuracy chamber have been designed separately. The temperature of furnace is set or changes by the controller.

Key Features:

  • Remote control via Ethernet link, RS-232
  • Very High Stability and accuracy
  • Real-time display of surface and setpoint temperature
  • Large emissive area with high uniformity
View Complete Details

LBB33CH Extended Area Black Body

2.55 Lakh /Piece Get Latest Price
  • Accuracy ±0.5°C
  • Power Supply 230 VAC, 1 ph. 50 Hz
  • Temperature range from 50 °C to 500 °C
  • Emissive Area 300 x 300 mm²
  • Emissive area uniformity ±3 at 400 °C
  • Emissivity 0.98±0.02
  • Stability ±0.1°C
  • Display resolution 0.1° C
  • Warm-up time 60 min
  • Head dimensions W x H x D (mm³) 550 x 550 x 260 mm,
  • Remote control Ethernet, RS-232

Extended area Black body is defined by the large emitting surface area precise temperature control with good uniformity. The blackbody is designed to provide infrared radiation as an ideal blackbody emitter. Because of the large uniform surface area the body called extended area black body.
We separately provide high accurate programmable controller with black body source. High-accuracy chambers have been designed separately. The temperature of the furnace is set or changes by the controller. 
Key Features:

  • Remote control via Ethernet link, RS-232
  • Very High Stability and accuracy
  • Real-time display of surface and setpoint temperature
View Complete Details

LBB11CH Extended Area Black Body

1.75 Lakh /Piece Get Latest Price
  • Weight 15 Kg
  • Power Supply 230 VAC, 1 ph. 50 Hz
  • Extended Areas Up to 100 Mm X 100 Mm²
  • Standard CE Certified
  • Emissive Area 100 x 100 mm²
  • Temperature range (Standard) 10°C to 110°C
  • Temperature range (Optional) 0°C to 110°C
  • Emissive area uniformity (1) ±0.20°C @50°C
  • Emissivity 0.98±(0.02)
  • Stability ±0.01°C
  • Temperature Measurement Accuracy ±0.3°C
  • Display Resolution 0.01°C
  • Method of Control Digital self tuned PID Controller
  • Head dimensions W x H x D (mm³) 300 X 320 X 190 mm
  • Max. Power Consumption 1 K W
  • Remote control Ethernet, RS-232
  • Remote Operating temperature range (head) 5°C to +25°C

Extended area black body is defined by the large emitting surface area precise temperature control with good uniformity. Tempsens make Blackbodies are state of the art, highly accurate, and stable with different standard sizes and temperature ranges. The LBBCH Series Extended Area blackbodies are low-temperature infrared reference sources operating either in absolute or differential mode.
This Blackbody series featuring very high stability, they are particularly well adapted for the characterization and performance validation of a very wide range of IR Sensors, such as high-resolution cameras for Thermography and long-range thermal imagers. Essentially the black body emits a known amount of energy for an infinite number of wavelengths. This enables us to draw the expected black body radiation curve for a given temperature. Temperature is accurately controlled by High accurate PID self-tuning controller.
During the past several years, we have acquired extensive knowledge of industrial temperature calibration. This expertise is reflected in our products which are all designed for daily use in an industrial environment.

Key Features:

  • Independent Controller with Real-time display and Calibration data.
  • Quick and convenient calibration technique.
  • Serial communication and computer interfacing by RS-232 Port.
  • Absolute temperature Range 0°C to 110°C.
  • Differential and Absolute modes of operation.
  • High thermal uniformity and emissivity.
  • Portable controller.
  • For Optional model (Temperature Range 0°C to 110°C) with Nitrogen Purging facility, the price will be 15% extra.
View Complete Details

Portable Calibrator (CALsys 650)

84,500 /Piece Get Latest Price
  • Min. Order (MOQ) 1 Piece(s)
  • Weight 10 Kg
  • Temperature Range 50°C to 650°C
  • Stability ±0.01°C at 50°C, ±0.02°C at 350°C, ±0.03°C at 650°C
  • Uniformity ±0.04°C at 50°C, ±0.07°C at 350°C, ±0.09°C at 650°C
  • Loading effect (with a 6.35 mm reference probe and three 6.35 mm probes) 0.04 °C
  • Insert OD dimensions 32mm
  • Immersion Depth 120mm
  • Cooling time 80 Min ( 650 °C to 100 °C)
  • Heating Time 20 Min
  • Resolution 0.1°C
  • Display LCD, °C or °F user-selectable
  • Power Requirements 230 VAC, 1KW(SO Hz)
  • Calibration Accredited Calibration Certificate Provided
  • Environmental Operating Conditions 0°C to 40°C, 0% to 90% RH (non-condensing)
  • Specifications valid in environmental conditions 13°C … 33°C
  • PC Interface Ethernet port (CALsys 650 PLUS) , RS - 232 (CALsys 650 )
  • Size (H x W x D) 325(H) x 185(W) x 265(D) mm
  • Input(CALsys 650 Autocal) Four Channels (One master and three test sensors), high-quality LEMO connector suitable for T/C& Rtd
  • Software The calibrator will be provided with software for data recording and report generation in Auto Mode
  • Data Logging(CALsys 650 Autocal) Data Logging facility with logged data export to the computer through LAN port (Optional USB)
  • Standard CE Certified

CALsys 650 offers medium temperature range from 50 to 650°C. It is a highly stable standard furnace for calibrating thermocouples / RTD. The comparison volume is a metallic block of special material, which has diameter of 32mm and 150mm long The temperature of the calibrator is set and controlled by a self tuned PID controller with automatic super fine adjustment.

Key Features:

  • Large Immersion Depths
  • Wide Operating Range (50°C to 650°C)
  • High Stability
  • PC interfacing
  • Simple to use and cost-effective


Accessories

  • Reference Standard Thermocouple ('K' Type T/C)
  • NABL accredited calibration certificate - 3 point
  • Software - Cal Soft including for setting bath temperature and monitoring the PV.
  • Graphical representations of PV/TIME with 2 hours data logging.
  • Operational Manual
  • Carry Case

Additional Information:

Payment Terms : T/T

Delivery Time : 4-6 Weeks

Specification

Temperature Range 50 to 650oC
Temperature Resolution 0.1oC
Stability ±0.025oC at 50oC
±0.035oC at 350oC
±0.07oC at 650oC
Uniformity ±0.04oC at 50oC
±0.07oC at 350oC
±0.09oC at 650oC
Controlling Sensor T/C “N” TYPE
Method of Control Digital self tuned PID Controller
Insert Construction Dia 32 x 150 mm long with 4 holes of 6.5 x 120 mm insertion depth
Time to Reach Max Temp 25 Mins
Time to Reach Max Temp to 100oC 70 Mins
Computer Interface RS - 232
Operating Temperature 20 to 45oC
Power Requirement 230 VAC, 1 KW
Dimensions 325(H) x 185(W) x 265(D) mm
Weight Approx 10 Kg

Download


Download Detail File : Click Here

Specification


Download Detail File : Click Here
View Complete Details

CALsys 650 Autocal - Portable Thermocouple Calibrator

1.55 Lakh /Piece Get Latest Price
  • Accuracy ±2°C
  • Weight 10 Kg
  • Temperature Range 50⁰C to 650⁰C
  • Stability ±0.01°C at 50°C, ±0.02°C at 350°C, ±0.03°C at 650°C
  • Radial uniformity ±0.04°C at 50°C, ±0.07°C at 350°C, ±0.09°C at 650°C
  • Loading effect (with a 6.35 mm reference probe and three 6.35 mm probes) 0.04 °C
  • Insert Od Dimensions 32mm
  • Immersion Depth 120mm
  • Cooling Time 80 Min ( 650 °c to 100 °c)
  • Heating Time 20 Min
  • Resolution 0.1°C
  • Display Lcd, °c or °f User-selectable
  • Power requirements 230 VAC, 1KW(SO Hz)
  • Calibration Accredited Calibration Certificate Provided
  • Environmental operating conditions Environmental operating conditions
  • Specifications Valid in Environmental Conditions 13°c … 33°c
  • PC Interface Ethernet port (CALsys 650 PLUS) , RS - 232 (CALsys 650 )
  • Size (H x W x D) 325(H) x 185(W) x 265(D) mm
  • Data Logging(CALsys 650 Autocal) Data Logging facility with logged data export to the computer through LAN port (Optional USB)

CALsys 650 Autocal offers easy to use portable temperature calibrator with a medium temperature range from 50 to 650°C. It is a highly stable standard furnace for calibrating thermocouples / RTD. This calibrator can be used on-site in workshops, test and measurement rooms as well as laboratories. The comparison volume is a metallic block of special material, which has a diameter of 32mm and 150mm long.
The CALsys 650 Autocal is an automatic temperature calibration system for the Thermocouple and RTD's. The system consists of a Temperature bath and PC software, which together contribute to the whole cycle of the auto-calibration process. The system accepts 4 channels, 4 Thermocouples, or 4 RTDs. The connection for these channels through a special type of locking connector. The channel configuration can be done with LCD display via a touch screen keypad. The thermocouple microvolt & RTD ohm reading for each channel is monitored with CJC compensation. After the calibration process complete the PC software generates a report of actual calibrated values for the inputs. Our newly designed CALsys 650 Autocal model offers better esthetic design and is performance-wise upgraded to the next level. This model offers better cooling time which is 2 times faster than our old model and has stability 30% better than the old CALsys 650 Autocal model. Hence our new model not only saves an important time for our valuable customer but also provides better performance.
With the Tempsens make Compact Temperature Calibrator, you have chosen an extremely effective instrument that we hope will live up to all your expectations. This is a fast, timesaving, and reliable true industrial temperature calibrator designed for on-site use.

Kay Features:

  • Internal CJC compensation
  • Data Logging of the selected channel
  • Ethernet Communication with CALsys Model & PC/Laptop
  • USB connector for communication (Optional)
  • Easy-to-read color 7/5 Inch LCD display with a perfect overview of the actual status
  • Intuitive, fast, and user-friendly navigation
  • Four channels(one master and three test sensors ).high quality universal LEMO connector suitable both for T/C (J, K, N T, R, S, B type) and Rtd.
  • Includes Easy to use Connectors


Accessories:

  • Reference Standard Thermocouple ('K' Type T/C)
  • NABL accredited calibration certificate - 3 point
  • Operational Manual
  • Carry Case

 

Input(CALsys 650 Autocal): Four Channels (One master and three test sensors), high-quality LEMO connector suitable for both T/C and Rtd.

Software: The calibrator will be provided with software for data recording (Manual Mode) and report generation in Auto Mode.

View Complete Details

CALsys -1200 Autocal Portable Thermocouple And RTD Calibrator

1.90 Lakh /Piece Get Latest Price
  • Accuracy ±3°C
  • Weight 12 Kg
  • Temperature Range 250 °C to 1200 °C
  • Stability ±0.1°C at 250°C, ±0.2°C at 700°C, ±0.3°C at 1200°C
  • Radial Uniformity ±0.20°C at 250°C, ±0.24°C at 700°C, ±0.36°C at 1200°C
  • Immersion Depth 160mm
  • Insert OD Dimensions 37mm
  • Method of Control Self Tunned PID Controller
  • Heating Time 60 Min
  • Cooling time 150 min(1200⁰C to 250⁰C )
  • Resolution 0.1⁰C up to 999⁰C
  • Display Lcd, ⁰c or ⁰f User-selectable
  • Size (HxWxD) 405(H) x 205(W) x 285(D)
  • Power Requirements 230 VAC, 1.5 KW(50Hz)
  • Computer Interface Rs- 232
  • Calibration Accredited Calibration Certificate Provided
  • Environmental operating conditions 0 ⁰C to 40 ⁰C, 0 % to 90 % RH(non-condensing)
  • Specification valid in environmental conditions 13 ⁰C . 33 ⁰C
  • Data logging (CALsys 1200 Autocal) Data logging facility with logged data export to computer through LAN port (optional USB)

The CALsys 1200 Autocal is an automatic temperature calibration system for the Thermocouple and RTD's.
The system consists of Temperature bath and PC software, which together contribute to the whole cycle of auto-calibration process.
The system accepts 4 channels, 4 Thermocouples or 4 RTD's.The connection for these channels through special type of locking connectors. The channel configuration can be done with LCD display via touch screen keypad.
The thermocouple microvolt & RTD ohm reading for each channel is monitored with CJC compensation. After the calibration process complete the PC software generates a report of actual calibrated values for the inputs.

Key Features:

  • Easy-to-read color 7 Inch LCD display with a perfect overview of the actual status
  • Intuitive, fast and user-friendly navigation
  • 4 Channel Calibration (4 No's for Thermocouples or 4 No's for RTD's)
  • Includes Easy to use Connectors
  • Internal CJC compensation


Accessories:

  • Reference Standard Thermocouple ('N'Type T/C)
  • NABL accredited calibration certificate - 3 point
  • Operational Manual
  • Carry Case

 

Input (CALsys 1200 Autocal): Four Channels (One master and three test sensors), high-quality LEMO connector suitable for both T/C (J, K, N, T, R, S, B type) and Rtd.

Software (CALsys 1200 Autocal): The calibrator should be provided with software for data recording (Manual Mode) and Test Certificate generation in Auto Mode.

View Complete Details

CALsys -100/40 Portable FPSC System Based Low Temperature Calibrator

5.85 Lakh /Piece Get Latest Price
  • Weight 13 Kg
  • Temperature Range -100 °C to 40 °C
  • Stability (30min) ±0.04 °C or Better
  • Radial Uniformity ±0.08°C or Better
  • Immersion depth 120 mm
  • Standard Fixed insert dimensions 6.5 mm x 4 holes
  • Method of control Self tuned PID Controller
  • Cooling time 70 Min ( Ambient 25°C to -100°C)
  • Resolution 0.1 °C (0.01 Optional)
  • Display LCD, °C or °F user-selectable
  • Computer Interface RS - 232
  • Environmental operating conditions 12 °C to 35 °C, 0 % to 90 % RH (non-condensing)
  • Specifications valid in environmental conditions 15°C … 30°C
  • Power Requirement 230 VAC, 350W
  • Dimensions 380(H) x 170(W) x 188(D) mm

Calsys -100/40 offers easy to use portable low-temperature calibrator with temperature range from -100 to 40°C. It is a highly stable standard furnace for calibrating RTD. This calibrator can be used on-site for ultra low-temperature calibration and also find application in aerospace, oil gas petrochemical, pharmaceutical industry, electric power, automotive and material process industry. The comparison volume is a metallic fixed block of special material, which has a fixed insert with 120mm long.
Low-temperature dry block furnace based on FPSC cooling system.This model provides special design isothermal enclosure which can calibrate sensor against the calibrator. The temperature of the calibrator is set and controlled by a self-tuned PID controller with automatic super fine adjustment.

Key Features:

  • Wide Operating Range (-100 to 40°C)
  • High Stability
  • PC interfacing
  • Simple to use and cost-effective
  • FPSC cooling system based calibrator


Accessories:

  • Reference Standard RTD
  • NABL accredited calibration certificate - 3 point
  • Software - Cal Soft including for setting bath temperature and monitoring the PV.
  • Graphical representations of PV/TIME with 2 hours data logging.
  • Operational Manual
  • Carry Case
View Complete Details

CALsys -30/110 Autocal Automatic Dry Block Calibrator

  • Temperature Range -30 to 110°C
  • Stability ±0.04°C at -30°C, ±0.06°C at 0°C, ±0.07°C at 110°C
  • Uniformity ±0.05°C at -35°C, ±0.07°C at 0°C, ±0.08°C at 110°C
  • Standard CE Certified
  • Temperature Resolution 0.1°C
  • Heating Time 10 min
  • Cooling Time 25 min
  • Fixed Insert Dimension 32 mm
  • Depth 120 mm
  • Method of control Digital Self Tuned PID Controller
  • Computer Interface RS - 232
  • Power Requirement 230 VAC, 500 W (50Hz)
  • Dimensions 380(H) x 170(W) x 188(D)mm
  • Instrument Weight 11 Kg(approx.)
  • Environmental Operating Conditions 0°C to 40°C, 0% to 90% RH (non-condensing)
  • Specifications valid in environmental conditions 13°C … 25°C

CALsys -30/110 Autocal is a Highly Stable Furnace for calibrating RTD. It offers a temperature range of -30 to 110°C. This calibrator can be used on-site for high-temperature calibration and applications like aerospace, oil gas petrochemical, pharmaceutical industry, electric power, automotive and material process industry. The comparison volume is a metallic fixed block of special material, which has a diameter of 32 mm and 120mm long. Low-temperature dry block furnace based on thermoelectric cooling circuitry.
The CALsys -30/110 Autocal is an automatic temperature of the calibration system for thermocouples and RTDs. The system consists of Temperature bath PC software, which together contributes to the whole cycle of the auto-calibration process. The system accepts 4 channels, 4 thermocouples, 4 RTDs.The channel configuration can be done with an LCD display via a touch screen keypad. The thermocouple microvolt & RTD ohm reading for each channel is monitored with CJC compensation. After the calibration process complete the PC software generates a report of actual calibrated values for inputs.

Key Features:

  • High Accuracy
  • High Stability and Uniformity
  • Wide Temperature Range
  • PC Interfacing
  • Simple to Use and Cost-Effective


Accessories

  • Standard Accessories
  • Reference Standard PRT…Part No.TPRT-A-300
  • NABL accredited calibration certificate - 3 point
  • Software - Including for setting bath temperature and monitoring the PV. Graphical representations of PV/TIME.
  • Operational Manual


Input: Four Channels (One master and three test sensors), high-quality LEMO connector suitable for both T/C and Rtd.

Software: The calibrator will be provided with software for data recording (Manual Mode) and report generation in Auto Mode.

Data Logging: Data Logging facility with logged data export to the computer through  LAN port (Optional USB)

View Complete Details

Portable Thermocouple Calibrator (CALsys 1200)

1.26 Lakh /Piece Get Latest Price
  • Min. Order (MOQ) 1 Piece(s)
  • Weight 12 kg
  • Temperature Range 250°C to 1200°C
  • Stability ±0.1°C at 250°C, ±0.2°C at 700°C, ±0.3°C at 1200°C
  • Uniformity ±0.20°C at 250°C, ±0.24°C at 700°C, ±0.36°C at 1200°C
  • Standard CE Certified
  • Immersion depth 160mm
  • Insert OD Dimensions 37mm
  • Method of Control Self Tunned PID Controller
  • Heating Time 60 Min
  • Cooling time 150 min(1200⁰C to 250⁰C )
  • Resolution 0.1⁰C up to 999⁰C
  • Display LCD, ⁰C or ⁰F user-selectable
  • Size (HxWxD) 405(H) x 205(W) x 285(D)
  • Power Requirements 230 VAC, 1.5 KW(50Hz)
  • Computer Interface RS- 232
  • Calibration Accredited Calibration Certificate Provided
  • Environmental operating conditions 0 ⁰C to 40 ⁰C, 0 % to 90 % RH(non-condensing)
  • Specification valid in environmental conditions 13 ⁰C . 33 ⁰C
  • Data logging (CALsys 1200 Autocal) Data logging facility with logged data export to computer through LAN port (optional USB)

CALsys 1200 offers high-temperature range from 250°C to 1200°C. It is a highly stable standard furnace for calibrating Thermocouples / RTD. It has been designed for high-temperature range calibration and find application in the glass, electrical power, automotive & material processing industries.
The comparison volume is a metallic block of special material, which is 37 mm in diameter with 215 mm long. The temperature of the calibrator is set and controlled by a self-tuned PID controller with automatic super fine adjustment. Version with 3 zone furnace is also available.

Key Features:

  • Large Immersion Depths
  • Wide Operating Range (250 to 1200°C)
  • High Stability
  • PC interfacing
  • Simple to Use and Cost-Effective


Accessories:

  • Reference Standard Thermocouple ('N' Type T/C)
  • NABL accredited calibration certificate - 3 point
  • Software - Cal Soft including for setting bath temperature and monitoring the PV. Graphical representations of PV/TIME with 2 hours data logging.
  • Operational Manual
  • Carry Case

 

Input (CALsys 1200 Autocal): Four Channels (One master and three test sensors), high-quality LEMO connector suitable for both T/C (J, K, N, T, R, S, B type) and Rtd.

Software (CALsys 1200 Autocal): The calibrator should be provided with software for data recording (Manual Mode) and Test Certificate generation in Auto Mode.

Additional Information:

Payment Terms : T/T

Delivery Time : 4-6 Weeks

Specification

Temperature Range 250 to 1200oC
Temperature Resolution 1.0oC
Stability ±0.1oC at 250oC
±0.2oC at 700oC
±0.4oC at 1200oC
Uniformity ±0.4oC at 1200oC
±0.24oC at 700oC
±0.26oC at 1200oC
Controlling Sensor PT/RH-PT T/C
Method of Control Digital self tuned PID Controller
Insert Construction Dia 37 x 215 mm long (2X6mm & 2X8 mm holes) of 160mm insertion dept
Time to Reach Max Temp 1.5 Hrs
Cooling Time 1200oC to 250oC 180 Mins
Computer Interface RS - 232
Operating Temperature 20 to 45oC
Power Requirement 230 VAC, 1.5 KW
Dimensions 405(H) x 205(W) x 285(D) mm
Weight Approx 14 Kg

Download


Download Detail File : Click Here
View Complete Details

CALsys -15/110 Peltier Based Temperature Calibrator

1.30 Lakh /Piece Get Latest Price
  • Min. Order (MOQ) 1 Piece(s)
  • Standard CE Certified
  • Temperature Range -15 to 110°C
  • Stability ±0.03°C at -15°C, ±0.05°C at 0°C, ±0.07°C at 110°C
  • Uniformity ±0.05°C at -15°C, ±0.07°C at 0°C, ±0.09°C at 110°C
  • Temperature Resolution 0.1°C
  • Time to Reach Min. Temp 25 Mins
  • Controlling Sensor Precision PRT
  • Insert Construction Dia 24x120 mm long, 3x6 mm hole with 115mm insertion depth
  • Method of control Digital self tuned PID Controller
  • Computer Interface RS - 232
  • Operating Temperature 20 to 25°C
  • Power Requirement 230 VAC, 500W
  • Dimensions 380(H) x 170(W) x 188(D) mm
  • Instrument Weight 60 Kg

CALsys -15/110 offers medium temperature range from -15°C to 110°C. It is highly stable standard temperature source for calibrating RTD/Thermocouple.
It has Peltier elements to generate stable temperatures in the well. The comparison volume is a metallic block of aluminum, which has a diameter of 24mm and 120mm length.

Key Features:

  • High Stability
  • Portability
  • PC Interfacing
  • Simple to use and cost-effective


Accessories:

  • Reference standard PRT
  • NABL accredited calibration certificate - 3 point
  • Software - cal soft including for setting bath temperature and monitoring the PV. graphical representations of PV/time with 2 hours data logging.
  • Operational manual
  • Carry case

Additional Information:

Payment Terms : T/T

Delivery Time : 4-6 Weeks

Download


Download Detail File : Click Here

Specification

Temperature Range 15 to 110oC
Temperature Resolution 0.1oC
Stability ± 0.03oC at-15oC
±0.05oC at 0oC
±0.07oC at 110oC
Uniformity ±0.05oC at -15oC
±0.07oC at 0oC
±0.09oC at 110oC
Controlling Sensor Precision PRT
Method of Control Digital self tuned PID Controller
Removable Insert Construction Dia 24 x 120 mm
long, 3 x 6 mm hole with 115mm insertion depth
Time to Reach Max/Min Temp 25 Mins
Operating Temperature 20 to 25oC
Computer Interface RS - 232
Power Requirement 230 VAC, 500 W
Dimensions 380(H) x 170(W) x 188(D) mm
Weight Approx 14 Kg





View Complete Details

Tempmet 09 Precision Thermometer

30,000 /Piece Get Latest Price
  • Weight Approx.0.25 Kg (Include Battery)
  • Operation Temperature and Humidity 0°C ~ 50°C, <80% RH
  • Storage Temperature and Humidity -10 °C ~ 60 °C, <70% RH
  • Power Requirement (AA Size) batteries, up to 1500 hours of continuous work time
  • Input Protection at Thermocouple Input 24V AC/DC Maximum
  • Dimension(Without holster) 115 mm X 70 mm x 30 mm (LxWxH)
  • Thermocouple K, S, E, T, J, R, B, N
  • RTD Pt1000, Cu50, Cu10
  • mV -100 to 200mV
  • mA -2 to 24 mV
  • Resistance 0 to 500 Ohms
  • Unit Ohms, mA, mV, °C, F, K
  • Resolution 0.000°C/0.000°F, 0.000 A/V/mA/mV

Specifications 01

RTD + T/C type RTD + T/C range Accuracy
Pt100 -200 C ~ +850 C ±0.02% RDG +0.060oC
Pt1000 -140 C ~ +320 C --
Cu50 -50 C ~ +150 C ± 0.080oC
Cu100 -50 C ~ +150 C ± 0.060oC
Ω -0.000 ~ 2200 Ω ±0.02% RDG +50mΩ
mV -100.0 ~ +200.0mV ±0.015% RDG +10μV
mA -2.0 ~ +24.0mA ±0.03% RDG +3μA
K -200oC ~ +1372oC ±0.50oC
S -0.0 ~ 1768oC ±0.8oC
E -200 ~ +1000oC 0.40oC
T -200 ~ +400oC ±0.50oC
J -210 ~ +1200oC ±0.50oC
R 0.0 ~ 1768oC ±0.8oC
B 300 ~ +1820oC ±0.9oC
N -200 ~ +1300oC ±0.50oC

Specificarion 02

Operation Temperature and Humidity 0 C ~ 50 C, <80% RH
Storage Temperature and Humidity -10 C ~ 60 C, <70% RH
Power Requirement (AA Size) batteries, up to 1500 hours of continuous work time
Input Protection at Thermocouple Input 24V AC/DC Maximum
Dimension(Without holster) 115 mm X 70 mm x 30 mm(LxWxH).
Weight Approx.0.25 Kg (Include Battery)
Input
Thermocouple K, S, E, T, J, R, B, N
RTD Pt1000, Cu50, Cu10
mV -100 to 200mV
mA -2 to 24 mV
Resistance 0 to 500 Ohms
Unit Ohms, mA, mV, oC, F, K
Resolution 0.000°C/0.000°F, 0.000 A/V/mA/mV

Download


Download Detail File : Click Here
View Complete Details

Tempmet 08 Precision Thermometer

12,000 /Piece Get Latest Price
  • Weight Approx.0.25 Kg (Include Battery)
  • Operation Temperature and Humidity 0°C ~ 50°C, <80% RH
  • Storage Temperature and Humidity -10 C ~ 60 C, <70% RH
  • Input Protection at Thermocouple Input 24V AC/DC Maximum
  • Dimension(Without holster) 115 mm X 70 mm x 30 mm (LxWxH)
  • Thermocouple K, S, E, T, J, R, B, N
  • RTD Pt100
  • Unit °C, F, K
  • Resolution 0.0°C/0.0°F

Specifications 01

RTD + T/C type RTD + T/C range Accuracy
Pt100 -200 C ~ +850 C ±0.05oC
K -200 C ~ +1372 C ±1.50oC
S 0 C ~ 1768 C ±2.40oC
E -200 C ~ +1000 C ±1.20oC
T -200 C ~ +400 C ±1.20oC
J -210 C ~ +1200 C ±1.20oC
R 0oC ~ +1768°C ±2.40oC
B 300oC ~ +1820oC ±2.40oC
N -200oC ~ +1300oC ±1.80oC

Specifications 02

Operation Temperature and Humidity 0 C ~ 50 C, <80% RH
Storage Temperature and Humidity -10 C ~ 60 C, <70% RH
Power Requirement (AA Size) bayyeries, up to 1500 hours of continuous work time
Input Protection at Thermocouple Input 24V AC/DC Maximum
Dimension(Without holster) 115 mm X 70 mm x 30 mm(LxWxH).
Weight Approx.0.25 Kg (Include Battery)
Input
Thermocouple K, S, E, T, J, R, B, N
RTD Pt100
Unit oC, F, K
Resolution 0.0oC/0.0oF

Download


Download Detail File : Click Here
View Complete Details
Tell Us What are you looking for? Will call you back