Our Products
Thermocouple
2 Products availableMeasuring Instruments & Equipment
2 Products availableSensors And Transducers
1 Products availableSecurity, Metal & Leak Detectors
1 Products availableSensors
1 Products availableWe offer a complete product range of Temperature Calibration Bath (TB-1100), Temperature Calibration Bath (TB-250), Temperature Calibration Bath (TB-600), Temperature Calibration Bath (TB-30) and Technical Specifications
Specifications
STEM O. D. | 6 mm |
---|---|
STEM Length | 300 mm |
Extension Length | 1 mt. Long Telephone Cord |
Holding | PVC Handle |
Accuracy | 1/10 DIN |
Range | -200o C. to 300o C. |
Periodicity of Calibration | 6 Months |
Calibration Certificate | Third party Calibration report by NABL LAB |
The Film PRTDSA | Wire wound PRTDS |
---|---|
Good vibration resistance. | Moderate to poor in vibration as per basic coil support. |
Poor to thermal shock/cycling. | Moderate to good again thermal shock. |
Limited temperature range. We recommend ambient to 250oC. only. | Vast temperature range -200oC to 650oC. |
Poor repeatability. | Good repeatable. |
Small in dimension as small as (1.5mm L x 1.5mm B x 1.2mm H). | Quite long in size compared to thin film (15mm min). |
Measuring current limitation to 1mA. High self heating. | Measuring current as high as 10 mm can be used. |
Mineral Insulated Metal Sheathed Thermocouple Cable :
MIMS thermocouple technology has brought revolution in the TE industries as it has clear winning edge over conventional ceramic twin bore insulator T/C.
Manufacturing Process :
MIMS cable are manufactured by using a higher diameter tubes and conductors. The conductors are inserted into metal pipe. The conductors are properly spaced in the pipe by using crushable MgO blocks. These MgO blocks provides insulation between the conductors as ell as with the wall. Also these blocks maintains the geometry, i.e. the position of conductors. The operation required to manufacture MIMS cable are :
|
MIMS T/C | Conventional T/C |
---|---|
Flexible in construction one can bend the T/C as requirement. | Cannot be bent |
Hermetically sealed construction less prone to de-calibration due to adulteration by atmosphere. | Open construction can get attached by atmosphere at high temperature and calibration may get shifted quickly |
Small diameter T/C as small as 0.5 mm is possible | Dimensional restriction |
Fast response | Slow in response |
In horizontal mounting at high temperature (Over 800oC.) sagging cannot create any problem of getting shorted etc. | Can get short due to bending |
Due to flexibility it can reach measuring point hard to reach. | Can not |
Effect of vibration is very less | Susceptible to failure in vibration |