Our Products
Non-corrosive and durable metal is used for their production in order to lift-up its quality and performance. We are a reputed Manufacturer, Exporter and Supplier of Digital Flame Photometer from Haryana, India. Its features of longevity, strength and perfect designs contribute well to their extensive demand. One can get hold of our Digital Flame Photometer at the most discounted prices. Order retail or bulk timely delivery is always executed!
Specifications
Model | S-931 |
---|---|
Range | Na : 0-100 ppm, k : 0-100 ppm, ca : 15-100 ppm (optional) li : 10-100 ppm (optional) |
Sensitivity | sodium (na) : 5 ppm, potassium (k) : 5 ppm, calcium (ca) : 10 ppm (optional), lithium (li) : 10 ppm (optional) |
Readout | 2 ½ digit bright red led display |
Accuracy | ± 2 % up to 40 ppm ± 5 % above 40 ppm |
Ignition system | with external lgniter |
Dimensions | 355w x 245h x 230dmm (approx. ) |
Weight | 7. 5 kg. (approx. ) |
Measurement system | measures one element at a time |
Repetability | ± 2 counts |
Detector | silicon photodiode |
Filters | narrow band interference glass filters |
Nebulizer | black bakelite, axial flow type |
Flame system | lpg and dry oil free air |
Warm up | time 10 minutes |
Power | 230 v± 10? ,50hz |
Model | S-931 |
---|---|
Range | Na : 0-100 ppm, k : 0-100 ppm, ca : 15-100 ppm (optional) li : 10-100 ppm (optional) |
Sensitivity | sodium (na) : 5 ppm, potassium (k) : 5 ppm, calcium (ca) : 10 ppm (optional), lithium (li) : 10 ppm (optional) |
Readout | 2 ½ digit bright red led display |
Accuracy | ± 2 % up to 40 ppm ± 5 % above 40 ppm |
Ignition system | with external lgniter |
Dimensions | 355w x 245h x 230dmm (approx. ) |
Weight | 7. 5 kg. (approx. ) |
Measurement system | measures one element at a time |
Repetability | ± 2 counts |
Detector | silicon photodiode |
Filters | narrow band interference glass filters |
Nebulizer | black bakelite, axial flow type |
Flame system | lpg and dry oil free air |
Warm up | time 10 minutes |
Power | 230 v± 10? ,50hz |
Compressor Unit S-930
Air supply | by oil free mini compressor unit with pressure regulator |
---|---|
Combustion | gas LPG controlled by precision regulator |
Power | 230v± 10 ,50hz |
Dimension | 275w x192h x 240d mm |
Weight | 6. 25 kg. (approx) |
Accessories | *instrument with na & k filters *sample holders *instruction manual *dust cover *mains lead *air and gas tubing along with end clamps *chimney *capability tubes *cleaning wires. |
Technical Specifications
Model | S-932 |
---|---|
Range | Na: 0-200 meq/l Ca: 0-2 meq/l K : 0-100 meq/l Li: 0-10 meq/l |
Sensitivity | Sodium (Na) : 5 ppm Potassium (K) : 5 ppm Calcium (Ca) : 10 ppm (Optional) Lithium (Li) : 10 ppm (Optional) |
Readout | Dual 2½ digit bright red LED display |
Accuracy | + 2% upto 100 meq/l + 5% above 100 meq/l |
Ignition System | With external lighter |
Dimensions | 355W X 245H X 230Dmm (Approx.) |
Weight | 7.5 Kg. (Approx.) |
Measurement System | Measures one element at a time |
Repetability | ± 2 Counts |
Detector | Silicon Photodiode |
Filters | Narrow band interference glass filters |
Nebulizer | Black bakelite, axial flow type |
Flame System | LPG and dry oil free air |
Warm Up Time | 10 minutes |
Power | 230 V± 10?,50HZ |
Compressor Unit
Air Supply | By oil free mini compressor unit with pressure regulator |
---|---|
Combustion | GAS LPG controlled by precision regulator |
Power | 230V± 10?,50Hz |
Dimension | 275W X192H X 240D mm |
Weight | 6.5kg. (Approx) |
Accessories | *instrument with Na & K Filters *Sample Holders *Instruction Manual * *Air and Gas Tubing along with End Clamps *Chimney *Capability Tubes *Cleaning Wires. |
It is all about quality and so we never ever sacrifice with it! The Microprocessor Flame Photometer that we deal in is designed by our team of experienced professionals under the strict eye of experts using latest technologies. The Microprocessor Flame Photometers – 935, provided by us, find their usage for the determination of sodium, potassium, calcium and lithium. They are equipped with advanced engineering techniques and latest microcontroller technology. Also, they have soft touch membrane key for ease of operations.
Technical Specifications
Mode | General | Serum | Urine |
---|---|---|---|
Range | Na: 0 - 100 ppm Upto 250 meq/l, 1:100 dil K: 0 - 100 ppm Upto 250 meq/l, 1:100 dil Ca: 0 - 100 ppm Upto 250 meq/l, 1:100 dil Li: 0 - 100 ppm Upto 250 meq/l, 1:100 dil |
Na: 0 - 200 1:100 dil K: 0 - 10 1:100 dil - Li: 0 - 2 1:5 dil |
Na: 0 - 250 1:100 dil K: 0 - 100 1:100 dil Ca: 0 - 10 1:2 dil - |
Sensitivity | General: Na: 0.5 ppm, K: 0.5 ppm, Li: 0.5 ppm, Ca: 15 ppm | ||
Filters | Na & K supplied (Ca & Li are optional at extra cost) | ||
Resolution | 0.1 ppm/meq | ||
Reproducibility | < 1% coefficient of variation for 20 consecutive samples using 10 ppm Na set as maximum standard | ||
Curve Fit Accuracy | < 2% error when 3 ppm Na/K and 5 ppm Li are set as maximum standards | ||
Display | 20 x 4 alphanumeric LCD with backlit | ||
Average Time | In-built in software | ||
Flame System | LPG and dry oil free air | ||
Detector | Silicon photodiode | ||
Calibration | Upto 5-Point calibration with curve fitting software | ||
Gas Control | Adjustable with knobs | ||
Ignition System | Auto ignition | ||
Automiser | Axial flow type | ||
Printer | Provision for attachment of dot matrix printer or HP laserjet/ inkjet (non-windows) printers with centronics parallel interface | ||
RS-232C | Available (PC software at extra cost) | ||
Power | 230 V + 10% AC, 50 Hz | ||
Dimensions | 285 x 255 x 210 mm (L x B x H) (Approx.) | ||
Weight | 7.5 Kg (Approx.) | ||
COMPRESSOR UNIT | |||
Air Supply | By oil free mini compressor unit with pressure regulator | ||
Combustion Gas | LPG controlled by precision regulator | ||
Power | 230 V + 10% AC, 50 Hz | ||
Dimensions | 290 x 255 x 210 mm (L x B x H) (Approx.) | ||
Weight | 8 Kg (Approx.) |