Our offered Product range includes Fire Alarm Systems, Fire Lite Modules, Fire alarm Xenon Strobes system and Ceiling Mounting Sounder.

Fire Alarm Systems

The patented communication protocol has a unique design of Variable Time Communication VTC. This new technology allows the data packets to transmit on the Fire Detection Loop for along distances and does not gets a ected with the Cable Characteristics. This technology shall help a healthy communication at the worst site installation conditions, or even during the severe re conditions. The Soft Addressing shall allow automatic addressing from the Fire Alarm Control Panel, making the commissioning of the system an easy and fast task.

features

  • Complies to EN54 part 3 + A1
  • Connected and Powered from the loop
  • Soft Addressing
  • Safe Addressing
  • Inbuilt Short Circuit Isolator
  • High dB output up to 100dB @1m
  • Compact in size
  • Lockable base
View Complete Details

Fire Lite Modules

  • Normal operating voltage 24 VDC.
  • Maximum SLC loop voltag 28.0 VDC.
  • Maximum SLC loop current 230 μA.
  • Ambient Temperatur 32°F to 120°F (0°C to 49°C)
  • Relative Humidity 93% ± 2% RH (noncondensing) at 32°C

The FireLite BG-12LX is a state-of-the-art, dual-action (i.e., requires two motions to activate the station) pull station that includes an addressable interface (mounted inside) for FireLites addressable fire alarm control panels (FACPs). Because the BG-12LX is addressable, the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm.

features

Maintenance personnel can open station for inspection and address setting without causing an alarm condition.

Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm.

Handle latches in down position and the word ACTIVATEDappears to clearly indicate the station has been operated.

Captive screw terminals wire-ready for easy connection to SLC loop (accepts up to 12 AWG/3.25 mm wire).

Can be surface mounted (with SB-10 or SB-I/O) or semiflush mounted. Semi-flush mount to a standard singlegang, double-gang, or 4"" (10.16 cm) square electrical box.

Smooth dual-action design.

Meets ADAAG controls and operating mechanisms guidelines (Section 4.1.3[13]); meets ADA requirement for 5 lb. maximum activation force.

Highly visible.

Attractive shape and textured finish.

Key reset.

Includes Braille text on station handle.

Optional trim ring (BG12TR).

Meets UL 38, Standard for Manually Actuated Signaling Boxes.

View Complete Details

Fire Alarm Xenon Strobes System

The NX series Xenon strobe units are available in two power ratings, 2 watt or 5 watt. The NX2 is a 2 watt xenon with a red base and red lens. The NX5 is 5 watts with a red base and red lens. The strobes are designed with a distinctive shape enabling a large lens to be incorporated. The internal electronic design is engineered to maximise light output. The strobes are low profile and allow simple installation through separate terminals for both input and output wiring. The NX strobes can be integrated onto systems using other sounders and strobes from either the Morley-IAS portfolio or any other compatible systems.

features

Xenon strobe unit

Stand alone operation

Large strobe lens

IP44, IP55 or IP66 rated

Easy cable entry & exit

Separate terminals for in/out wiring

CE marked

specification

mechanical

Material ABS body Flammability UL94-HB Colour Red base and red lens Dimensions (H xWxD) 124 x 92 x 60 mm (using NBL base) 124 x 92 x 72 mm (using NBD or NBS base) Operating temperature -25C to + 70C Maximum humidity 93% @ 55C (NBD base)

View Complete Details

Ceiling Mounting Sounder

The NBS series of conventional sounders are designed for use either underneath detector bases or as a standalone low profile sounder. These sounders have been designed with an emphasis on acoustic efficiency resulting in an omnidirectional, high volume sound field. These high output levels are achieved with a low current draw. The integral electronics provide the user with a choice of either continuous or sweeping tones at a variety of frequencies. The NBS sounders are available in a choice two colours red or white and supplied with either 3 or 14 pre-configured sounder patterns/tones. The sounder can be used under any detector base with 60mm mounting centres and an external diameter of up to 102mm. Alternatively, it can be wall mounted as a stand-alone unit. The NBS sounders can be integrated onto systems using other sounders from the Morley-IAS portfolio or other compatible systems.

FEATURES

Ceiling mounting base sounder

78 - 93dBA at 1 metre @ 24Vdc

Internal volume control

Rugged construction, IP44 rated

Easy cable entry & exit

Designed to meet EN54: part 3

CE marked

SPECIFICATION

mechanicalMaterial ABS Flammability UL94-HB Colour Red or White Dimensions 30 x 117 (H x dia) mm including cover plate Operating temperature -30C to + 70C Maximum humidity 93% @ 40C Ingress protection IP44

electricalOperating voltage 9-33Vdc Current consumption 9.0mA @ 12Vdc 18mA @ 24Vdc Output (dB) 78 - 93dB(A) adjustable @24Vdc 87dB @1m(800Hz, 12Vdc) 93dB @1m (800Hz, 24Vdc) Number of tones NBS3 - 3 tones NBS14 - 14 tones