Post Buy Requirement

Our Products

  1. Insecticides 7 Products available
  2. Fire Alarm Control Panel 3 Products available
  3. Electric Control Panels

    2 Products available
  4. Leak Detectors

    2 Products available
  5. Telecommunication Equipment & System

    2 Products available
  6. Security And Inspection Devices

    2 Products available
  7. Fire Fighting & Protection

    2 Products available
  8. Electric Circuit Components & Parts

    1 Products available
  9. Computer Cables, Adapters & Modules

    1 Products available
  10. Wires

    1 Products available
  11. Others Products 3 Products available

Other Products / Services

Our offered Product range includes RSCAT TRND 500/500(Blinking LED) Transducer Rodent Repellent System and RSCAT TRND 400/400(Blinking LED) Transducer Rodent Repellent System.

RSCAT TRND 500/500(Blinking LED) Transducer Rodent Repellent System

RSCAT UltrasonicPest Repellers are electronic transmitters of high frequency sound . They emit intensive sound at high decibel levelsthat is audible and painful to pests but inaudible to humans. The pests will usually leave the area being protected bythe ultrasound.They do not get killed.
The powerful sound waves generated by the transducers of RSCAT repellers are within the hearing range of many pets and cause them pain and discomfort. Sometimes they will leave the area being protected immediately, in other cases it will take as long as two to three weeks before significant reduction in infestation occurs.
RSCAT transducers are completely quiet. If you cannot hear do not thing that the unit is not working. You cannot hear ultrasound.

Features :

  • Each transducer covers an open area of 500 Sq feet where the average height of the ceiling is 12 feet. Even when installed in the false ceiling or false floorings it will cover an area of 500 sq. feet. The same is possible because of the transducer's streaming effect design.
  • Each transducer occupies a maximum space of 15 cubic.inches and aesthetically designed to match your décor.
  • Maximum Cable length per Rodent Console is 1000mtrs.
  • Being monopolar in nature. They can be installed in any sensitive area with zero risk of sparking.
  • The transducers can withstand high temperatures in the false ceilings and low temperatures in cold storages and air locks.
  • The transducers do not need a power connection.
  • The transducers can be tested on an audible range independently, by selecting the Transducer testing menu from the LCD panel.
View Complete Details

Double Door Hose Box

  • Frequency 50Hz, 60Hz
  • Weight 480 Gm
  • Length 5.5 inches
  • Width 2 inches
  • Height 11 inches
  • Number Of Doors Double Door

Features of Products :

  • The double door FRP hose box can accommodate maximum 15mtr wire and one branch pipe.
  • It is made from Fibre Glass material with ISO-Italic Resins.
  • It has Al Powder coated handle & S.S./brass hinges with brass screws.
  • It has two 40 X 3mm S.S. flat from top to bottom for extra strength.
  • It has glass/acrylic sheet on door embedded in EPDM rubber gasket for easy fixing.
  • FRP thickness will be 1.5-2.0mm.
  • It comes in red color.
  • All dimensions specified above are in mm.
  • Hose Boxes come in M.S, Al and FRP.
View Complete Details

VAVA Annunciation Panel

  • Power Consumption 15 Watts.
  • Operating Voltage 230 V AC.
  • LED matrix 7*90 with 3mm LED.
  • LED color Red
  • No. of Events Six.
  • Number of Messages Six + One(default When No Event).
  • Number of Sounds Six.
  • Screen Size 2" * 18".
  • Working temperature 0 to 50 degree C.
  • Construction Metal Enclosure wall mounted.
  • Size 22" x 4" x 8".

Features of Products :

  • Six potential free contact input for six events.
  • At each event custom set message is displayed and prerecorded announcement is activated.
  • Event messages can be edited by connecting IBM keyboard directly to the display.
  • RS485 output for repeater.
  • 2000 characters can be saved in memory.
View Complete Details

Digital Addressable Water Leak Detection System- SYNOPSYS

  • Supply Voltage 230V AC – 50Hz +/- 10 %
  • LCD Display Backlit
  • Max. Cable length 150 meters
  • Relay Type Leak Common Relay output
  • Audible Sounder for Alarm
  • External Hooter 24VDC
  • Fuse 2 Amp
  • Current consumption standby 0.4Amp
  • Alarm State 1 Amp
  • Working temperature 10 to 50 *C
  • Construction Metal Enclosure Wall mounted
  • Size ( HXWXD) 240x240x100 mm

The water leak system comprises of a Master Water leak detection panel (SY-3618), Distance locator Slave modules (MD-450), sensor cable (Synopsys WD-AS) and alarm sounders. The Water leak detection sensor cable typically used to detect water leaks in critical rooms to monitor leakage and to extend alarm to the BMS.
The MD-450 is locally placed in the Server rooms, and communicates with the Master Synopsys Panel through RS-485. It serves as an interface between the Master and the Sensor Cable. The Master panel SY-3618 is to be installed in the BMS room. The master panel will communicate with the clients BMS integration PC-side software using Modbus. The panel will activate a common sounder once the leak/fault is detected. The Master is equipped with a touch screen display and will display the name of the slave and the distance where the leak is been detected in meters.

Salient Features :-

  • Operates on 230V 50 HZ AC
  • Has potential free output and LED indication.
  • Displays distance to leak location in meters.
  • Indicates cable break condition.
  • Maximum length of linear leak detection cable is 150meters.
  • Can detect leak anywhere along the entire cable length.
  • Built in audio sounder and common hooter output.
  • Easy to install and operate.
  • Self-restoring.
  • Soft membrane switches.
  • Communicates with the Master using RS485.
View Complete Details

Water Leak Detection Module Je 1141

  • Supply Voltage 230V AC – 50Hz +/- 10 %
  • Response Time < 3 Sec.
  • Weight 1kg (approx.)
  • Output to WLD Cable Isolated A.C. Supply 12V.
  • SPDT single contact NO-NC.
  • Current consumption standby 0.4Amp.
  • Alarm State 0.8 Amp.
  • Working Temp. -10 to 50Degree C.
  • Size HXWXD 120X200X75mm
  • Size ( HXWXD) 120x200x75 mm
  • Construction Metal Enclosure Wall mounted

The water leak system comprises of a Main zone water leak panel, interface modules, sensor cable and alarm sounders. The water leak panel has potential free relay contacts which extends alarms to BMS.
The Water leak detection sensor cable typically used to detect water leaks in critical rooms to monitor leakage and optionally extend alarm in the BMS. The Cable draws excitation signal from a start of the line module. It serves as an interface between the Water leak detection panel and the Sensor Cable. The Start of Line Interface Module is locally placed in the False Flooring, and shall be connected to the WLD Panel through standard Cu- Ar Cable.
Testing procedure involves physical application of a wet cloth to the cable, to test the relay operation. The Panel sounds the Alarms, and optionally notifies the BMS system.

Features of Products :

  • Given an isolated supply AC supply to water leak cable to avoid oxidation or erosion of cables over a period of time.
  • The module can be connected to water leak Detection Annunciation Panel.
  • The module provides potential free relay output.
  • The module comes in ABS enclosure.
  • The module has compact and elegant looks.
View Complete Details

Addressable Water Leak Detection Cable WD-AS

  • Material PVC Twisted Pair With Stainless Steel 316 Elements
  • Leader Cable 3 mtrs
  • Dimensions 3.5mm dia
  • No. of Wires 4 – 2 water sensitive and two data sensitive
  • Max cable length 150 mtrs
  • Std cable lengths 10, 15, 20, 25, 30 and so on upto 150 mtrs.
  • Guarantee 12 months from the date of supply.

Water Leak Detection Conventional System (WD-AS) uses water leak cable in conjunction with Water Leak Panels to detect water under floors.

Features of Products :

  • Water Leak Detection cable consists of four conductors, two water sensitive and two data.
  • The cable is restorable and corrosion resistant and does not require replacement after being wet.
  • Cable can be installed in the path of a potential water leak.


Installation and Testing :

  • Installation: Install the WLD cable on the floor. Connect the leader end of WLD cable to WLD Panel.
  • Testing: Immerse the WLD cable in water to stimulate a water leak. An alarm will be sent to WLD Panel and the display the leak distance in meters. Dry the WLD Cable to restore in normal mode.
View Complete Details

Conventional Water Leak Cable WD-CS

  • Material PVC Twisted Pair With Stainless Steel 316 Elements
  • Leader Cable 3 mtrs
  • Dimensions 3.5mm dia
  • No. of Wires Two
  • Max cable length 200 mtrs
  • Std cable lengths 10, 15, 20, 25, 30 and so on upto 200 mtrs.
  • Guarantee 12 months from the date of supply.
  • Cable lengths It comes in multiple of 5mtrs

Water Leak Detection Conventional System (WD-CS) uses water leak cable in conjunction with Water Leak Panels to detect water under floors.

Features of Products :

  • PVC twisted pair with stainless steel 316 elements.
  • The cable is restorable and corrosion resistant and does not require replacement after being wet.
  • Cable can be installed in the path of a potential water leak.


Installation and Testing :

  • Installation: Install the WLD cable on the floor. Connect the leader end of WLD cable to WLD Panel.
  • Testing: Place a wet cloth over the WLD cable to stimulate a water leak. The length of cable in contact with wet cloth should be at least 3-inches. An alarm will be sent to WLD Panel. Dry the WLD Cable to restore in normal mode.
View Complete Details

RSCAT TRND 400/400(Blinking LED) Transducer Rodent Repellent System

RSCAT UltrasonicPest Repellers are electronic transmitters of high frequency sound . They emit intensive sound at high decibel levelsthat is audible and painful to pests but inaudible to humans. The pests will usually leave the area being protected bythe ultrasound.They do not get killed.
The powerful sound waves generated by the transducers of RSCAT repellers are within the hearing range of many pets and cause them pain and discomfort. Sometimes they will leave the area being protected immediately, in other cases it will take as long as two to three weeks before significant reduction in infestation occurs.
RSCAT transducers are completely quiet. If you cannot hear do not thing that the unit is not working. You cannot hear ultrasound.

Features :

  • Each transducer covers an open area of 400 Sq feet where the average height of the ceiling is 12 feet. Even when installed in the false ceiling or false floorings it will cover an area of 400 sq. feet. The same is possible because of the transducer's streaming effect design.
  • Each transducer occupies a maximum space of 15 cubic.inches and aesthetically designed to match your décor.
  • Maximum Cable length per Rodent Console is 1000mtrs.
  • Being monopolar in nature. They can be installed in any sensitive area with zero risk of sparking.
  • The transducers can withstand high temperatures in the false ceilings and low temperatures in cold storages and air locks.
  • The transducers do not need a power connection.
  • The transducers can be tested on an audible range independently, by selecting the Transducer testing menu from the LCD panel.
View Complete Details

Digital Addressable Water Leak Detection Panel

  • Weight 3 Kgs Approx
  • Supply Voltage 230V AC – 50Hz +/- 10 %
  • Dimensions 250(H) X 250(W) X 110(D) mm.
  • LCD Display Backlit.
  • Internal Sounder Buzzer to indicate alarm and fault.
  • External Sounder Hooter 24V DC.
  • Fuse 1 Amp.
  • Working Temp. 0 to 50Degree C
  • Construction M.S powder coated

This water leak system comprises of a Distance Locator panel, sensor cable and alarm sounders. The water leak panel has potential free relay contacts which extends alarms to BMS.
The Water leak detection sensor cable typically used to detect water leaks in critical rooms to monitor leakage and optionally extend alarm in the BMS. It serves as an interface between the Water leak detection panel and the Sensor Cable. The Start of Line Interface Module is locally placed in the False Flooring, and shall be connected to the WLD Panel through standard Cu- Ar Cable.
The WLD Panel is be capable of supplying power to the interface modules, and serves as the annunciation of alarms through LCD fascia. The panel activates common sounder. Testing procedure involves physical application of a wet cloth to the cable, to test the relay operation. The Panel sounds the Alarms, and optionally notifies the BMS system.

Features of Products :

  • The Distance Locator Panel operates on 230V AC supply with battery backup. It will provide supervision of interface modules The features of the Synopsys Distance Locator panel are as follows:
  • LCD Display to indicate the module number and the distance to leak location in meters.
  • The panel also displays a cable fault in case of cable break condition.
  • A modbus output is provided for BMS communication.
  • The system is equipped with a built-in audible sounder and a common hooter.
  • A common relay output is given along with the common alarm relay out.

Datasheet


Download Detail File : Click Here

Tender Specification


Download Detail File : Click Here
View Complete Details

Water Leak Detection Touch Screen Conventional Panel Sy T103

  • Supply Voltage 230V AC – 50Hz +/- 10 %
  • Display Touch Screen, 3.2TFT
  • SPDT single contact NO-NC
  • Internal sounder Buzzer to indicate Leak and fault
  • External Sounder Hooter 24V DC.
  • Fuse 1Amp.
  • Response Time < 2 Sec
  • Alarm State 0.8 Amp
  • Working Temp. 10 to 50Degree C
  • Construction Metal Enclosure Wall
  • Weight 4.5 Kgs Aprrox
  • Size ( HXWXD) 270x360x115 mm

The water leak system comprises of a touch screen water leak panel, sensor cable and alarm sounders. The water leak panel has potential free relay contacts which extends alarms to BMS.
The Water leak detection sensor cable typically used to detect water leaks in critical rooms to monitor leakage and optionally extend alarm in the BMS. The WLD panel is enabled with a touch screen display, which makes the use of switches redundant.
Testing procedure involves physical application of a wet cloth to the cable, to test the relay operation. The Panel sounds the Alarms, and optionally notifies the BMS system.

Salient Features :

  • The panel equipped with Touch Screen Display can monitor up to 8 Zones:
  • Zone sensitivity feature is provided which enables the user to set the sensitivity of sensing cables as per the site requirements.
  • Zone addressing facility is provided in the settings which enables the user to name the zones as per the site specifications.
  • Zones can be isolated at Power on/Reset.
  • Event log of 100 events is provided.
  • Input to water leak cable is an isolated Ac supply which ensures the cable will not be subject to oxidation and erosion over time avoiding the degradations problems associated with DC system.
  • Zone wise potential free relay output is provided for BMS.
  • Compact and elegant looks.
  • Panel is equipped with cable break condition where zone window turns blue in case if the cable is disconnected or if it breaks.
  • Cable break condition is implemented in the system which will give an alarm for the zone whose cable has been damaged or removed. The respective zone window will turn blue.
View Complete Details

Jay JE-1141 Conventional Fire Alarm Panel

  • Size 375 (H) mm x 300 (W) mm x 100 (D) mm
  • Material M.s. Powder Coated.
  • Operating Temprature 10- 49 degree C
  • Cabling Four wire to be looped.

Features of Products :

  • The panel ranges from 2 to 64 zones.
  • The panel complies with IS 2189 specification.
  • The panel has separate fire and fault indications.
  • The panel also has separate fire and common fault relay.
  • The panel comprises of a 4Amp powe supply unit.
  • Battery backup is provided along with the AC supply.


Technical Specification :
INTERNAL POWER SUPPLY UNIT

  • Constant potential battery charger 14.5V DC.
  • Output Current limited to 3 A.
  • Mains supply input voltage range 230V AC + or 10 %, 50 Hz.
  • Total panel quiescent current 50mA nominal.
  • Approx. Standby time 4.5 Ah Batt. 24 hrs.
  • Battery recharge time from discharge 3 Hr. approx.


INTERNAL RELAY CONTACT RATING

  • Fire Relay 5 Amp. S.P. 240 V DC.


Panel Indications :

  • System ON Green LED - System normal.
  • Fire Red LED MCP/Detector activated.
  • Zone fault Amber LED Indicates zone wiring detector fault.
  • Zone fire Red LED indicates zone where fire has been detected.


External Controls :

  • Sound : To sound external as well as internal sounders.
  • Silence : To silence external as well as internal sounders.
  • Reset : Lamp test & resets the panels.
View Complete Details

Water Leak Detection Conventional Panel ... JAY 3523

  • Supply Voltage 230V AC – 50Hz +/- 10 %
  • Response Time < 3 Sec.
  • Weight 3 Kgs Aprrox.
  • LCD Display Backlit.
  • Relay Zone Relay’s and one common Relay.
  • SPDT single contact NO-NC.
  • Internal Sounder Buzzer to indicate Leak.
  • External Sounder Hooter 24VDC.
  • Current consumption standby 0.4Amp.
  • Alarm State 0.8 Amp.
  • Working Temp. 10 to 50Degree C.
  • Construction Metal Enclosure Wall mounted.
  • Size ( HXWXD) : 270x360x115 270x360x115 mm

The water leak system comprises of a Main zone water leak panel, interface modules, sensor cable and alarm sounders. The water leak panel has potential free relay contacts which extends alarms to BMS.
The Water leak detection sensor cable typically used to detect water leaks in critical rooms to monitor leakage and optionally extend alarm in the BMS. The Cable draws excitation signal from a start of the line module. It serves as an interface between the Water leak detection panel and the Sensor Cable. The Start of Line Interface Module is locally placed in the False Flooring, and shall be connected to the WLD Panel through standard Cu- Ar Cable.
The WLD Panel is be capable of supplying power to the interface modules, and serves as the annunciation of alarms through LCD fascia. The panel activates common sounder. Testing procedure involves physical application of a wet cloth to the cable, to test the relay operation. The Panel sounds the Alarms, and optionally notifies the BMS system.

Features of Products :

  • The panel equipped with LCD Display can monitor 20 Zones.
  • Input to water leak cable is an isolated Ac supply which ensures the cable will not be subject to oxidation and erosion over time avoiding the degradations problems associated with DC system.
  • The panel is equipped with SPDT keypad for navigation.
  • Compact and elegant looks.

Tender Specification


Download Detail File : Click Here
View Complete Details

Disabled Persons Toilet Alarm System

Having a differently-abled persons’ toilet alarm system installed in your residential or commercial property is significantly essential if a mobility-impaired or differently-abled person’s will be using your toilet or bathroom. A differently-abled toilet alarm is a simple yet extremely useful system that can be facilely installed in all sorts of bathrooms and helps to alert and notify fellow building dwellers if any differently-abled person’s is in trouble or distress while using the toilet or bathroom. These alarms are triggered and activated by pulling on a cord. This differently-abled person’s toilet alarm system also ensures the safety of a differently-abled person’s while on  the property and enables more independence and privacy while using the bathroom.

Let us walk you through the differently-abled toilet alarm features

  • Simple 2 wire operation for all field devices
  • Control Panel supporting up to 4 zones
  • Simple maintenance
  • On-board buzzer in both Control Panel
  • Zone LED indication on Control Panel
  • Full range of field devices available (i.e. Pull Cord, Cancel, Reset & Remote Indicator)
  • Control Panel with potential free alarm output for BMS integration.
  • Differently abled WC sticker

This differently-abled persons’ toilet alarm system is available as a single zone kit that can be expanded up to 4 zones (where one zone is usually used for each toilet). It has been designed for use in differently-abled persons’ abodes to meet the requirements of BS8300.

 

Ideally suited for

  • Health Centers 
  • Sheltered Housing 
  • Public Buildings
  • Commercial Buildings 
  • Care Homes 
  • Assisted Living Establishments
  • Shops 
  • Schools
  • Sports Facilities 
  • Cinema
  • Granny Flats

Download


Download Detail File : Click Here
View Complete Details

Single Door Hose Box

  • Material Mild Steel
  • Thickness 0-15mm
  • Door Style Single
  • Length 270mm
  • Width 227mm
  • Height 50mm

Features of Products :

  • The single door FRP hose box can accommodate maximum 15mtr wire.
  • It is made from Fibre Glass material with ISO-Italic Resins.
  • It has Al Powder coated with one extra key.
  • It has two 40 X 3mm s.s. flat from top to bottom for extra strength.
  • It has glass embedded in EPDM rubber gasket for easy fixing.
  • FRP thickness will be 1.5-2.0mm.
  • It comes in red color.
  • All dimensions specified above are in mm.
  • Hose Boxes come in M.S, Al and FRP.

Diagram


Download Detail File : Click Here
View Complete Details

Gas Release Conventional Fire Alarm Panel

  • Supply Voltage 230V AC – 50Hz +/- 10 %
  • Battery voltage 24V DC
  • Power output 850mW
  • Normal Operating voltage 24VDC.
  • Hooter Output 1A.
  • EOL Resistor 4.7K, 1/4watt.
  • Solenoid nominal V & I 24VDC 1A.
  • Loop Resistance 50Ω

Functions : After fire in both the zones following operation takes place in sequence, the timer starts. The delay can be set from 0 to 250 sec with the help of dip switch. The Panels Timer LED On and potential Free Timer Relay operates. After the delay is over, relay of solenoid valve operates, 24 V DC output for Solenoid valve and potential Free Gas Release relay also operates.

Abort : After cross zoning the time delay starts and for some reason we do not want to release gas, then short the terminals of ABORT and timer stops. Abort LED on the Panel will glow. Once we release Abort switch then again Timer starts and after set delay, relay of solenoid valve operates.

Manual Release : The Manual release can be achieved by shorting manual release terminals and with set time delay, relay of solenoid valve operates.

Features of Products :

  • Operates on 230V supply with battery backup with built in charging.
  • Low battery visual warning with audible tone.
  • LED indication for Timer On, Abort and Gas Release.
  • Relay output for actuators.
  • Zone disable facility.
  • Solenoid Output with time delay.
  • Made from M.S. CRCA rugged with powder coated finish.
View Complete Details

Jay Je-190 (ERTL) Conventional Fire Alarm Panel

Features of Products :

  • The panel ranges from 2 to 64 zones.
  • The panel complies with IS 2189 specification.
  • The panel has separate fire and fault indications.
  • The panel also has separate fire and common fault relay.
  • The panel comprises of a 2Amp powe supply unit.
  • Battery backup is provided along with the AC supply.
  • The panel is equipped with a 24VdC piezoelectric buzzer for fault and fire.


Technical Specification :
INTERNAL POWER SUPPLY UNIT

  • Constant potential battery charger 27.5V DC Adjustable.
  • Output Current limited to 2 A.
  • Low battery voltage monitored at 18 V DC Adjustable.
  • Battery charger monitoring for failure.
  • Mains supply monitoring for failure.
  • Mains supply input voltage range 230V AC + or 10 %, 50 Hz.
  • Total panel quiescent current 50mA nominal.
  • Approx. Standby time 4.5 Ah Batt. 36 hrs.
  • Battery recharge time from discharge 1 Hr. approx.


INTERNAL RELAY CONTACT RATING

  • Fire Relay 5 Amp. S.P. 240 V DC.
  • Common fault relay 5 Amp. S.P. 240 V DC.
  • Aux. Fire relay 5 Amp. S.P. 240 V AC.


Panel Indications :

  • System ON Green LED - System normal.
  • Common Fault Amber LED Internal buzzer will sound intermittently.
  • Common Fire Red LED - Detector activated.
  • Zone fault Amber LED Indicates zone wiring and detector faults.
  • Zone fire Red LED indicates zone where fire has been detected.
  • AC fail Amber LED Indicates loss of mains.
  • DC fail Amber LED Indicates battery fault.
  • Batt. Low Amber LED Indicates battery supply below 18V DC


External Controls :

  • Sound : To sound external as well as internal sounders.
  • Silence : To silence external as well as internal sounders.
  • Reset : Lamp test & resets the panels.
  • Isolate : The zone to add/clean detectors.
  • Test : International standard walk test.
View Complete Details

JE-190 Public Addressable System

Features of Products :

  • The panel consists of 2 to 60 Zones.
  • The panel complies with IS 2189 specification.
  • The panel has separate fire and fault indications.
  • The panel also has separate fire and common fault relay.
  • The panel comprises of a 4Amp power supply unit.
  • Battery backup is provided along with the AC supply.
  • The panel is equipped with a 24VdC piezoelectric buzzer for fault and fire.


Technical Specification :
INTERNAL POWER SUPPLY UNIT

  • Constant potential battery charger 27.5V DC Adjustable.
  • Output Current limited to 2 A.
  • Low battery voltage monitored at 18 V DC Adjustable.
  • Battery charger monitoring for failure.
  • Mains supply monitoring for failure.
  • Mains supply input voltage range 230V AC + or – 10 %, 50 Hz.
  • Total panel quiescent current 50mA nominal.
  • Approx. Standby time 4.5 AH 36 hrs.
  • Battery recharge time from discharge 1 Hr. approx.


INTERNAL RELAY CONTACT RATING

  • Fire Relay 5 Amps S.P. 240 V DC.
  • Common fault relay 5 Amps S.P. 240 V DC.
  • Aux. Fire relay 5 Amps S.P. 240 V AC.


Panel Indications :

  • System ON Green LED - System normal.
  • Common Fault Amber LED – Internal buzzer will sound intermittently.
  • Common Fire Red LED - Detector activated.
  • Zone fault Amber LED – Indicates zone wiring and detector faults.
  • Zone fire Red LED – indicates zone where fire has been detected.
  • AC fail Amber LED – Indicates loss of mains.
  • DC fail Amber LED – Indicates battery fault.
  • Batt. Low Amber LED – Indicates battery supply below 18V DC.


External Controls :

  • Sound : To sound external as well as internal sounders.
  • Silence : To silence external as well as internal sounders.
  • Reset : Lamp test & resets the panels.
  • Isolate : The zone to add/clean detectors.
  • Test : International standard walk test.
  • Auto/manual : Amplifier in auto/manual mode.
  • Volume : Increase/ decrease amplifier volume.
  • Call All : Announcement to all zones simultaneously.
  • Selected switch for individual zone announcement.

Wiring Diagram


Download Detail File : Click Here
View Complete Details

JE-1141 Public Addressable System

Features of Products :

  • The panel consists of 2 to 60 Zones.
  • The panel complies with IS 2189 specification.
  • The panel has separate fire and fault indications.
  • The panel also has separate fire and common fault relay.
  • The panel comprises of a 4Amp power supply unit.
  • Battery backup is provided along with the AC supply.(Optional)
  • The panel is equipped with a 24VdC piezoelectric buzzer for fault and fire.


Technical Specification :
INTERNAL POWER SUPPLY UNIT

  • Constant potential battery charger 27.5V DC Adjustable
  • Output Current limited to 2 A
  • Mains supply input voltage range 230V AC + or – 10 %, 50 Hz
  • Total panel quiescent current 50mA nominal
  • Approx. Standby time 4.5 AH 36 hrs.
  • Battery recharge time from discharge 1 Hr. approx.


INTERNAL RELAY CONTACT RATING

  • Fire Relay 5 Amps S.P. 240 V DC
  • Common fault relay 5 Amps S.P. 240 V DC
  • Aux. Fire relay 5 Amps S.P. 240 V AC


Panel Indications :

  • System ON Green LED - System normal
  • Common Fault Amber LED – Internal buzzer will sound intermittently
  • Common Fire Red LED - Detector activated
  • Zone fault Amber LED – Indicates zone wiring and detector faults
  • Zone fire Red LED – indicates zone where fire has been detected


External Controls :

  • Sound - To sound external as well as internal sounders.
  • Silence - To silence external as well as internal sounders.
  • Reset - Lamp test & resets the panels.
  • Auto/manual - Amplifier in auto/manual mode.
  • Volume - Increase/ decrease amplifier volume.
  • Call All - Announcement to all zones simultaneously.
View Complete Details

Analog Annunciator Panel

  • Operating Voltage 230 V AC 50Hz
  • LED color Red
  • No. of inputs up to 60 Zones
  • Potential free output up to 60 Zones
  • Power consumption 15Watts
  • Working temperature 0 to 50 degree C
  • Construction Metal Enclosure wall mounted
  • Battery Backup Voltage 24V
  • Current rating of battery 4.5mAH

Salient Features :

  • Repeater panel is available up to 60 zones
  • Potential free output (Optional).
  • LED’s are available for giving an indication to the user about the event.
  • The Repeater panel can work on 24V input or a potential free input from a relay.
  • The panel works on 230V/50Hz AC supply and also works on battery.
  • Common hooter output is also available for indication.
  • Lamp test function is available to check if all the indications are working.
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

List of Other Products by Synopsys Tech Pvt Ltd. from Mumbai, Maharashtra.
Post Buy Requirement

Our Products

  1. Insecticides 7 Products available
  2. Fire Alarm Control Panel 3 Products available
  3. Electric Control Panels

    2 Products available
  4. Leak Detectors

    2 Products available
  5. Telecommunication Equipment & System

    2 Products available
  6. Security And Inspection Devices

    2 Products available
  7. Fire Fighting & Protection

    2 Products available
  8. Electric Circuit Components & Parts

    1 Products available
  9. Computer Cables, Adapters & Modules

    1 Products available
  10. Wires

    1 Products available
  11. Others Products 3 Products available

Our Products

We offer a complete product range of RSCAT TRND 500/500(Blinking LED) Transducer Rodent Repellent System and RSCAT TRND 400/400(Blinking LED) Transducer Rodent Repellent System

RSCAT TRND 500/500(Blinking LED) Transducer Rodent Repellent System

RSCAT UltrasonicPest Repellers are electronic transmitters of high frequency sound . They emit intensive sound at high decibel levelsthat is audible and painful to pests but inaudible to humans. The pests will usually leave the area being protected bythe ultrasound.They do not get killed.
The powerful sound waves generated by the transducers of RSCAT repellers are within the hearing range of many pets and cause them pain and discomfort. Sometimes they will leave the area being protected immediately, in other cases it will take as long as two to three weeks before significant reduction in infestation occurs.
RSCAT transducers are completely quiet. If you cannot hear do not thing that the unit is not working. You cannot hear ultrasound.

Features :

  • Each transducer covers an open area of 500 Sq feet where the average height of the ceiling is 12 feet. Even when installed in the false ceiling or false floorings it will cover an area of 500 sq. feet. The same is possible because of the transducer's streaming effect design.
  • Each transducer occupies a maximum space of 15 cubic.inches and aesthetically designed to match your décor.
  • Maximum Cable length per Rodent Console is 1000mtrs.
  • Being monopolar in nature. They can be installed in any sensitive area with zero risk of sparking.
  • The transducers can withstand high temperatures in the false ceilings and low temperatures in cold storages and air locks.
  • The transducers do not need a power connection.
  • The transducers can be tested on an audible range independently, by selecting the Transducer testing menu from the LCD panel.
View Complete Details

Double Door Hose Box

  • Frequency 50Hz, 60Hz
  • Weight 480 Gm
  • Length 5.5 inches
  • Width 2 inches
  • Height 11 inches
  • Number Of Doors Double Door

Features of Products :

  • The double door FRP hose box can accommodate maximum 15mtr wire and one branch pipe.
  • It is made from Fibre Glass material with ISO-Italic Resins.
  • It has Al Powder coated handle & S.S./brass hinges with brass screws.
  • It has two 40 X 3mm S.S. flat from top to bottom for extra strength.
  • It has glass/acrylic sheet on door embedded in EPDM rubber gasket for easy fixing.
  • FRP thickness will be 1.5-2.0mm.
  • It comes in red color.
  • All dimensions specified above are in mm.
  • Hose Boxes come in M.S, Al and FRP.
View Complete Details

VAVA Annunciation Panel

  • Power Consumption 15 Watts.
  • Operating Voltage 230 V AC.
  • LED matrix 7*90 with 3mm LED.
  • LED color Red
  • No. of Events Six.
  • Number of Messages Six + One(default When No Event).
  • Number of Sounds Six.
  • Screen Size 2" * 18".
  • Working temperature 0 to 50 degree C.
  • Construction Metal Enclosure wall mounted.
  • Size 22" x 4" x 8".

Features of Products :

  • Six potential free contact input for six events.
  • At each event custom set message is displayed and prerecorded announcement is activated.
  • Event messages can be edited by connecting IBM keyboard directly to the display.
  • RS485 output for repeater.
  • 2000 characters can be saved in memory.
View Complete Details

Digital Addressable Water Leak Detection System- SYNOPSYS

  • Supply Voltage 230V AC – 50Hz +/- 10 %
  • LCD Display Backlit
  • Max. Cable length 150 meters
  • Relay Type Leak Common Relay output
  • Audible Sounder for Alarm
  • External Hooter 24VDC
  • Fuse 2 Amp
  • Current consumption standby 0.4Amp
  • Alarm State 1 Amp
  • Working temperature 10 to 50 *C
  • Construction Metal Enclosure Wall mounted
  • Size ( HXWXD) 240x240x100 mm

The water leak system comprises of a Master Water leak detection panel (SY-3618), Distance locator Slave modules (MD-450), sensor cable (Synopsys WD-AS) and alarm sounders. The Water leak detection sensor cable typically used to detect water leaks in critical rooms to monitor leakage and to extend alarm to the BMS.
The MD-450 is locally placed in the Server rooms, and communicates with the Master Synopsys Panel through RS-485. It serves as an interface between the Master and the Sensor Cable. The Master panel SY-3618 is to be installed in the BMS room. The master panel will communicate with the clients BMS integration PC-side software using Modbus. The panel will activate a common sounder once the leak/fault is detected. The Master is equipped with a touch screen display and will display the name of the slave and the distance where the leak is been detected in meters.

Salient Features :-

  • Operates on 230V 50 HZ AC
  • Has potential free output and LED indication.
  • Displays distance to leak location in meters.
  • Indicates cable break condition.
  • Maximum length of linear leak detection cable is 150meters.
  • Can detect leak anywhere along the entire cable length.
  • Built in audio sounder and common hooter output.
  • Easy to install and operate.
  • Self-restoring.
  • Soft membrane switches.
  • Communicates with the Master using RS485.
View Complete Details

Water Leak Detection Module Je 1141

  • Supply Voltage 230V AC – 50Hz +/- 10 %
  • Response Time < 3 Sec.
  • Weight 1kg (approx.)
  • Output to WLD Cable Isolated A.C. Supply 12V.
  • SPDT single contact NO-NC.
  • Current consumption standby 0.4Amp.
  • Alarm State 0.8 Amp.
  • Working Temp. -10 to 50Degree C.
  • Size HXWXD 120X200X75mm
  • Size ( HXWXD) 120x200x75 mm
  • Construction Metal Enclosure Wall mounted

The water leak system comprises of a Main zone water leak panel, interface modules, sensor cable and alarm sounders. The water leak panel has potential free relay contacts which extends alarms to BMS.
The Water leak detection sensor cable typically used to detect water leaks in critical rooms to monitor leakage and optionally extend alarm in the BMS. The Cable draws excitation signal from a start of the line module. It serves as an interface between the Water leak detection panel and the Sensor Cable. The Start of Line Interface Module is locally placed in the False Flooring, and shall be connected to the WLD Panel through standard Cu- Ar Cable.
Testing procedure involves physical application of a wet cloth to the cable, to test the relay operation. The Panel sounds the Alarms, and optionally notifies the BMS system.

Features of Products :

  • Given an isolated supply AC supply to water leak cable to avoid oxidation or erosion of cables over a period of time.
  • The module can be connected to water leak Detection Annunciation Panel.
  • The module provides potential free relay output.
  • The module comes in ABS enclosure.
  • The module has compact and elegant looks.
View Complete Details

Addressable Water Leak Detection Cable WD-AS

  • Material PVC Twisted Pair With Stainless Steel 316 Elements
  • Leader Cable 3 mtrs
  • Dimensions 3.5mm dia
  • No. of Wires 4 – 2 water sensitive and two data sensitive
  • Max cable length 150 mtrs
  • Std cable lengths 10, 15, 20, 25, 30 and so on upto 150 mtrs.
  • Guarantee 12 months from the date of supply.

Water Leak Detection Conventional System (WD-AS) uses water leak cable in conjunction with Water Leak Panels to detect water under floors.

Features of Products :

  • Water Leak Detection cable consists of four conductors, two water sensitive and two data.
  • The cable is restorable and corrosion resistant and does not require replacement after being wet.
  • Cable can be installed in the path of a potential water leak.


Installation and Testing :

  • Installation: Install the WLD cable on the floor. Connect the leader end of WLD cable to WLD Panel.
  • Testing: Immerse the WLD cable in water to stimulate a water leak. An alarm will be sent to WLD Panel and the display the leak distance in meters. Dry the WLD Cable to restore in normal mode.
View Complete Details

Conventional Water Leak Cable WD-CS

  • Material PVC Twisted Pair With Stainless Steel 316 Elements
  • Leader Cable 3 mtrs
  • Dimensions 3.5mm dia
  • No. of Wires Two
  • Max cable length 200 mtrs
  • Std cable lengths 10, 15, 20, 25, 30 and so on upto 200 mtrs.
  • Guarantee 12 months from the date of supply.
  • Cable lengths It comes in multiple of 5mtrs

Water Leak Detection Conventional System (WD-CS) uses water leak cable in conjunction with Water Leak Panels to detect water under floors.

Features of Products :

  • PVC twisted pair with stainless steel 316 elements.
  • The cable is restorable and corrosion resistant and does not require replacement after being wet.
  • Cable can be installed in the path of a potential water leak.


Installation and Testing :

  • Installation: Install the WLD cable on the floor. Connect the leader end of WLD cable to WLD Panel.
  • Testing: Place a wet cloth over the WLD cable to stimulate a water leak. The length of cable in contact with wet cloth should be at least 3-inches. An alarm will be sent to WLD Panel. Dry the WLD Cable to restore in normal mode.
View Complete Details

RSCAT TRND 400/400(Blinking LED) Transducer Rodent Repellent System

RSCAT UltrasonicPest Repellers are electronic transmitters of high frequency sound . They emit intensive sound at high decibel levelsthat is audible and painful to pests but inaudible to humans. The pests will usually leave the area being protected bythe ultrasound.They do not get killed.
The powerful sound waves generated by the transducers of RSCAT repellers are within the hearing range of many pets and cause them pain and discomfort. Sometimes they will leave the area being protected immediately, in other cases it will take as long as two to three weeks before significant reduction in infestation occurs.
RSCAT transducers are completely quiet. If you cannot hear do not thing that the unit is not working. You cannot hear ultrasound.

Features :

  • Each transducer covers an open area of 400 Sq feet where the average height of the ceiling is 12 feet. Even when installed in the false ceiling or false floorings it will cover an area of 400 sq. feet. The same is possible because of the transducer's streaming effect design.
  • Each transducer occupies a maximum space of 15 cubic.inches and aesthetically designed to match your décor.
  • Maximum Cable length per Rodent Console is 1000mtrs.
  • Being monopolar in nature. They can be installed in any sensitive area with zero risk of sparking.
  • The transducers can withstand high temperatures in the false ceilings and low temperatures in cold storages and air locks.
  • The transducers do not need a power connection.
  • The transducers can be tested on an audible range independently, by selecting the Transducer testing menu from the LCD panel.
View Complete Details

Digital Addressable Water Leak Detection Panel

  • Weight 3 Kgs Approx
  • Supply Voltage 230V AC – 50Hz +/- 10 %
  • Dimensions 250(H) X 250(W) X 110(D) mm.
  • LCD Display Backlit.
  • Internal Sounder Buzzer to indicate alarm and fault.
  • External Sounder Hooter 24V DC.
  • Fuse 1 Amp.
  • Working Temp. 0 to 50Degree C
  • Construction M.S powder coated

This water leak system comprises of a Distance Locator panel, sensor cable and alarm sounders. The water leak panel has potential free relay contacts which extends alarms to BMS.
The Water leak detection sensor cable typically used to detect water leaks in critical rooms to monitor leakage and optionally extend alarm in the BMS. It serves as an interface between the Water leak detection panel and the Sensor Cable. The Start of Line Interface Module is locally placed in the False Flooring, and shall be connected to the WLD Panel through standard Cu- Ar Cable.
The WLD Panel is be capable of supplying power to the interface modules, and serves as the annunciation of alarms through LCD fascia. The panel activates common sounder. Testing procedure involves physical application of a wet cloth to the cable, to test the relay operation. The Panel sounds the Alarms, and optionally notifies the BMS system.

Features of Products :

  • The Distance Locator Panel operates on 230V AC supply with battery backup. It will provide supervision of interface modules The features of the Synopsys Distance Locator panel are as follows:
  • LCD Display to indicate the module number and the distance to leak location in meters.
  • The panel also displays a cable fault in case of cable break condition.
  • A modbus output is provided for BMS communication.
  • The system is equipped with a built-in audible sounder and a common hooter.
  • A common relay output is given along with the common alarm relay out.

Datasheet


Download Detail File : Click Here

Tender Specification


Download Detail File : Click Here
View Complete Details

Water Leak Detection Touch Screen Conventional Panel Sy T103

  • Supply Voltage 230V AC – 50Hz +/- 10 %
  • Display Touch Screen, 3.2TFT
  • SPDT single contact NO-NC
  • Internal sounder Buzzer to indicate Leak and fault
  • External Sounder Hooter 24V DC.
  • Fuse 1Amp.
  • Response Time < 2 Sec
  • Alarm State 0.8 Amp
  • Working Temp. 10 to 50Degree C
  • Construction Metal Enclosure Wall
  • Weight 4.5 Kgs Aprrox
  • Size ( HXWXD) 270x360x115 mm

The water leak system comprises of a touch screen water leak panel, sensor cable and alarm sounders. The water leak panel has potential free relay contacts which extends alarms to BMS.
The Water leak detection sensor cable typically used to detect water leaks in critical rooms to monitor leakage and optionally extend alarm in the BMS. The WLD panel is enabled with a touch screen display, which makes the use of switches redundant.
Testing procedure involves physical application of a wet cloth to the cable, to test the relay operation. The Panel sounds the Alarms, and optionally notifies the BMS system.

Salient Features :

  • The panel equipped with Touch Screen Display can monitor up to 8 Zones:
  • Zone sensitivity feature is provided which enables the user to set the sensitivity of sensing cables as per the site requirements.
  • Zone addressing facility is provided in the settings which enables the user to name the zones as per the site specifications.
  • Zones can be isolated at Power on/Reset.
  • Event log of 100 events is provided.
  • Input to water leak cable is an isolated Ac supply which ensures the cable will not be subject to oxidation and erosion over time avoiding the degradations problems associated with DC system.
  • Zone wise potential free relay output is provided for BMS.
  • Compact and elegant looks.
  • Panel is equipped with cable break condition where zone window turns blue in case if the cable is disconnected or if it breaks.
  • Cable break condition is implemented in the system which will give an alarm for the zone whose cable has been damaged or removed. The respective zone window will turn blue.
View Complete Details

Jay JE-1141 Conventional Fire Alarm Panel

  • Size 375 (H) mm x 300 (W) mm x 100 (D) mm
  • Material M.s. Powder Coated.
  • Operating Temprature 10- 49 degree C
  • Cabling Four wire to be looped.

Features of Products :

  • The panel ranges from 2 to 64 zones.
  • The panel complies with IS 2189 specification.
  • The panel has separate fire and fault indications.
  • The panel also has separate fire and common fault relay.
  • The panel comprises of a 4Amp powe supply unit.
  • Battery backup is provided along with the AC supply.


Technical Specification :
INTERNAL POWER SUPPLY UNIT

  • Constant potential battery charger 14.5V DC.
  • Output Current limited to 3 A.
  • Mains supply input voltage range 230V AC + or 10 %, 50 Hz.
  • Total panel quiescent current 50mA nominal.
  • Approx. Standby time 4.5 Ah Batt. 24 hrs.
  • Battery recharge time from discharge 3 Hr. approx.


INTERNAL RELAY CONTACT RATING

  • Fire Relay 5 Amp. S.P. 240 V DC.


Panel Indications :

  • System ON Green LED - System normal.
  • Fire Red LED MCP/Detector activated.
  • Zone fault Amber LED Indicates zone wiring detector fault.
  • Zone fire Red LED indicates zone where fire has been detected.


External Controls :

  • Sound : To sound external as well as internal sounders.
  • Silence : To silence external as well as internal sounders.
  • Reset : Lamp test & resets the panels.
View Complete Details

Water Leak Detection Conventional Panel ... JAY 3523

  • Supply Voltage 230V AC – 50Hz +/- 10 %
  • Response Time < 3 Sec.
  • Weight 3 Kgs Aprrox.
  • LCD Display Backlit.
  • Relay Zone Relay’s and one common Relay.
  • SPDT single contact NO-NC.
  • Internal Sounder Buzzer to indicate Leak.
  • External Sounder Hooter 24VDC.
  • Current consumption standby 0.4Amp.
  • Alarm State 0.8 Amp.
  • Working Temp. 10 to 50Degree C.
  • Construction Metal Enclosure Wall mounted.
  • Size ( HXWXD) : 270x360x115 270x360x115 mm

The water leak system comprises of a Main zone water leak panel, interface modules, sensor cable and alarm sounders. The water leak panel has potential free relay contacts which extends alarms to BMS.
The Water leak detection sensor cable typically used to detect water leaks in critical rooms to monitor leakage and optionally extend alarm in the BMS. The Cable draws excitation signal from a start of the line module. It serves as an interface between the Water leak detection panel and the Sensor Cable. The Start of Line Interface Module is locally placed in the False Flooring, and shall be connected to the WLD Panel through standard Cu- Ar Cable.
The WLD Panel is be capable of supplying power to the interface modules, and serves as the annunciation of alarms through LCD fascia. The panel activates common sounder. Testing procedure involves physical application of a wet cloth to the cable, to test the relay operation. The Panel sounds the Alarms, and optionally notifies the BMS system.

Features of Products :

  • The panel equipped with LCD Display can monitor 20 Zones.
  • Input to water leak cable is an isolated Ac supply which ensures the cable will not be subject to oxidation and erosion over time avoiding the degradations problems associated with DC system.
  • The panel is equipped with SPDT keypad for navigation.
  • Compact and elegant looks.

Tender Specification


Download Detail File : Click Here
View Complete Details

Disabled Persons Toilet Alarm System

Having a differently-abled persons’ toilet alarm system installed in your residential or commercial property is significantly essential if a mobility-impaired or differently-abled person’s will be using your toilet or bathroom. A differently-abled toilet alarm is a simple yet extremely useful system that can be facilely installed in all sorts of bathrooms and helps to alert and notify fellow building dwellers if any differently-abled person’s is in trouble or distress while using the toilet or bathroom. These alarms are triggered and activated by pulling on a cord. This differently-abled person’s toilet alarm system also ensures the safety of a differently-abled person’s while on  the property and enables more independence and privacy while using the bathroom.

Let us walk you through the differently-abled toilet alarm features

  • Simple 2 wire operation for all field devices
  • Control Panel supporting up to 4 zones
  • Simple maintenance
  • On-board buzzer in both Control Panel
  • Zone LED indication on Control Panel
  • Full range of field devices available (i.e. Pull Cord, Cancel, Reset & Remote Indicator)
  • Control Panel with potential free alarm output for BMS integration.
  • Differently abled WC sticker

This differently-abled persons’ toilet alarm system is available as a single zone kit that can be expanded up to 4 zones (where one zone is usually used for each toilet). It has been designed for use in differently-abled persons’ abodes to meet the requirements of BS8300.

 

Ideally suited for

  • Health Centers 
  • Sheltered Housing 
  • Public Buildings
  • Commercial Buildings 
  • Care Homes 
  • Assisted Living Establishments
  • Shops 
  • Schools
  • Sports Facilities 
  • Cinema
  • Granny Flats

Download


Download Detail File : Click Here
View Complete Details

Single Door Hose Box

  • Material Mild Steel
  • Thickness 0-15mm
  • Door Style Single
  • Length 270mm
  • Width 227mm
  • Height 50mm

Features of Products :

  • The single door FRP hose box can accommodate maximum 15mtr wire.
  • It is made from Fibre Glass material with ISO-Italic Resins.
  • It has Al Powder coated with one extra key.
  • It has two 40 X 3mm s.s. flat from top to bottom for extra strength.
  • It has glass embedded in EPDM rubber gasket for easy fixing.
  • FRP thickness will be 1.5-2.0mm.
  • It comes in red color.
  • All dimensions specified above are in mm.
  • Hose Boxes come in M.S, Al and FRP.

Diagram


Download Detail File : Click Here
View Complete Details

Gas Release Conventional Fire Alarm Panel

  • Supply Voltage 230V AC – 50Hz +/- 10 %
  • Battery voltage 24V DC
  • Power output 850mW
  • Normal Operating voltage 24VDC.
  • Hooter Output 1A.
  • EOL Resistor 4.7K, 1/4watt.
  • Solenoid nominal V & I 24VDC 1A.
  • Loop Resistance 50Ω

Functions : After fire in both the zones following operation takes place in sequence, the timer starts. The delay can be set from 0 to 250 sec with the help of dip switch. The Panels Timer LED On and potential Free Timer Relay operates. After the delay is over, relay of solenoid valve operates, 24 V DC output for Solenoid valve and potential Free Gas Release relay also operates.

Abort : After cross zoning the time delay starts and for some reason we do not want to release gas, then short the terminals of ABORT and timer stops. Abort LED on the Panel will glow. Once we release Abort switch then again Timer starts and after set delay, relay of solenoid valve operates.

Manual Release : The Manual release can be achieved by shorting manual release terminals and with set time delay, relay of solenoid valve operates.

Features of Products :

  • Operates on 230V supply with battery backup with built in charging.
  • Low battery visual warning with audible tone.
  • LED indication for Timer On, Abort and Gas Release.
  • Relay output for actuators.
  • Zone disable facility.
  • Solenoid Output with time delay.
  • Made from M.S. CRCA rugged with powder coated finish.
View Complete Details

Jay Je-190 (ERTL) Conventional Fire Alarm Panel

Features of Products :

  • The panel ranges from 2 to 64 zones.
  • The panel complies with IS 2189 specification.
  • The panel has separate fire and fault indications.
  • The panel also has separate fire and common fault relay.
  • The panel comprises of a 2Amp powe supply unit.
  • Battery backup is provided along with the AC supply.
  • The panel is equipped with a 24VdC piezoelectric buzzer for fault and fire.


Technical Specification :
INTERNAL POWER SUPPLY UNIT

  • Constant potential battery charger 27.5V DC Adjustable.
  • Output Current limited to 2 A.
  • Low battery voltage monitored at 18 V DC Adjustable.
  • Battery charger monitoring for failure.
  • Mains supply monitoring for failure.
  • Mains supply input voltage range 230V AC + or 10 %, 50 Hz.
  • Total panel quiescent current 50mA nominal.
  • Approx. Standby time 4.5 Ah Batt. 36 hrs.
  • Battery recharge time from discharge 1 Hr. approx.


INTERNAL RELAY CONTACT RATING

  • Fire Relay 5 Amp. S.P. 240 V DC.
  • Common fault relay 5 Amp. S.P. 240 V DC.
  • Aux. Fire relay 5 Amp. S.P. 240 V AC.


Panel Indications :

  • System ON Green LED - System normal.
  • Common Fault Amber LED Internal buzzer will sound intermittently.
  • Common Fire Red LED - Detector activated.
  • Zone fault Amber LED Indicates zone wiring and detector faults.
  • Zone fire Red LED indicates zone where fire has been detected.
  • AC fail Amber LED Indicates loss of mains.
  • DC fail Amber LED Indicates battery fault.
  • Batt. Low Amber LED Indicates battery supply below 18V DC


External Controls :

  • Sound : To sound external as well as internal sounders.
  • Silence : To silence external as well as internal sounders.
  • Reset : Lamp test & resets the panels.
  • Isolate : The zone to add/clean detectors.
  • Test : International standard walk test.
View Complete Details

JE-190 Public Addressable System

Features of Products :

  • The panel consists of 2 to 60 Zones.
  • The panel complies with IS 2189 specification.
  • The panel has separate fire and fault indications.
  • The panel also has separate fire and common fault relay.
  • The panel comprises of a 4Amp power supply unit.
  • Battery backup is provided along with the AC supply.
  • The panel is equipped with a 24VdC piezoelectric buzzer for fault and fire.


Technical Specification :
INTERNAL POWER SUPPLY UNIT

  • Constant potential battery charger 27.5V DC Adjustable.
  • Output Current limited to 2 A.
  • Low battery voltage monitored at 18 V DC Adjustable.
  • Battery charger monitoring for failure.
  • Mains supply monitoring for failure.
  • Mains supply input voltage range 230V AC + or – 10 %, 50 Hz.
  • Total panel quiescent current 50mA nominal.
  • Approx. Standby time 4.5 AH 36 hrs.
  • Battery recharge time from discharge 1 Hr. approx.


INTERNAL RELAY CONTACT RATING

  • Fire Relay 5 Amps S.P. 240 V DC.
  • Common fault relay 5 Amps S.P. 240 V DC.
  • Aux. Fire relay 5 Amps S.P. 240 V AC.


Panel Indications :

  • System ON Green LED - System normal.
  • Common Fault Amber LED – Internal buzzer will sound intermittently.
  • Common Fire Red LED - Detector activated.
  • Zone fault Amber LED – Indicates zone wiring and detector faults.
  • Zone fire Red LED – indicates zone where fire has been detected.
  • AC fail Amber LED – Indicates loss of mains.
  • DC fail Amber LED – Indicates battery fault.
  • Batt. Low Amber LED – Indicates battery supply below 18V DC.


External Controls :

  • Sound : To sound external as well as internal sounders.
  • Silence : To silence external as well as internal sounders.
  • Reset : Lamp test & resets the panels.
  • Isolate : The zone to add/clean detectors.
  • Test : International standard walk test.
  • Auto/manual : Amplifier in auto/manual mode.
  • Volume : Increase/ decrease amplifier volume.
  • Call All : Announcement to all zones simultaneously.
  • Selected switch for individual zone announcement.

Wiring Diagram


Download Detail File : Click Here
View Complete Details

JE-1141 Public Addressable System

Features of Products :

  • The panel consists of 2 to 60 Zones.
  • The panel complies with IS 2189 specification.
  • The panel has separate fire and fault indications.
  • The panel also has separate fire and common fault relay.
  • The panel comprises of a 4Amp power supply unit.
  • Battery backup is provided along with the AC supply.(Optional)
  • The panel is equipped with a 24VdC piezoelectric buzzer for fault and fire.


Technical Specification :
INTERNAL POWER SUPPLY UNIT

  • Constant potential battery charger 27.5V DC Adjustable
  • Output Current limited to 2 A
  • Mains supply input voltage range 230V AC + or – 10 %, 50 Hz
  • Total panel quiescent current 50mA nominal
  • Approx. Standby time 4.5 AH 36 hrs.
  • Battery recharge time from discharge 1 Hr. approx.


INTERNAL RELAY CONTACT RATING

  • Fire Relay 5 Amps S.P. 240 V DC
  • Common fault relay 5 Amps S.P. 240 V DC
  • Aux. Fire relay 5 Amps S.P. 240 V AC


Panel Indications :

  • System ON Green LED - System normal
  • Common Fault Amber LED – Internal buzzer will sound intermittently
  • Common Fire Red LED - Detector activated
  • Zone fault Amber LED – Indicates zone wiring and detector faults
  • Zone fire Red LED – indicates zone where fire has been detected


External Controls :

  • Sound - To sound external as well as internal sounders.
  • Silence - To silence external as well as internal sounders.
  • Reset - Lamp test & resets the panels.
  • Auto/manual - Amplifier in auto/manual mode.
  • Volume - Increase/ decrease amplifier volume.
  • Call All - Announcement to all zones simultaneously.
View Complete Details

Analog Annunciator Panel

  • Operating Voltage 230 V AC 50Hz
  • LED color Red
  • No. of inputs up to 60 Zones
  • Potential free output up to 60 Zones
  • Power consumption 15Watts
  • Working temperature 0 to 50 degree C
  • Construction Metal Enclosure wall mounted
  • Battery Backup Voltage 24V
  • Current rating of battery 4.5mAH

Salient Features :

  • Repeater panel is available up to 60 zones
  • Potential free output (Optional).
  • LED’s are available for giving an indication to the user about the event.
  • The Repeater panel can work on 24V input or a potential free input from a relay.
  • The panel works on 230V/50Hz AC supply and also works on battery.
  • Common hooter output is also available for indication.
  • Lamp test function is available to check if all the indications are working.
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us