1 Products availableCentrifugal Blowers move air by means of centrifugal force generated by a rotating cylindrical impeller. Used for applications where increased air pressure, increased static pressure or high airflow is required. Centrifugal Blowers have a small outlet, which concerntrates air in a single direction and are therefore suitable for localMore..
Specifications
Model | Supply Voltage | Frequency Hz |
Current A |
Speed RPM |
Max Air Flow CFM |
Max Static Pressure | Capacitor μF | |
Pa | mm of H2O | |||||||
CB 1665 W | Single Phase 110V | 60 | 4.2 | 2500 | 480 | 570 | 57 | 18 |
CB 1665 X | Single Phase 230V | 50 | 2.1 | 2200 | 420 | 570 | 48 | 6 |
CB 1665 Y | Three Phase 230V | 60 | 2 | 2500 | 480 | 570 | 57 | - |
CB 1665 Y | Three Phase 415V | 50 | 1 | 2250 | 420 | 570 | 48 | - |
Air Flow Vs Static Pressure
Dimensions
Wiring Diagram
Short Black wires & connect the capacitor as shown. To change the direction, connect the supply wire from White to Red.
Wiring Diagram
Red wires are for running winding & Black wires are for starting winding. To Change the direction, interchange Black wire or Red wire.
Wiring Diagram For Three Phase Blower
To Change the direction, interchange any two wires between U, V & W. For 415 V supply, wires are connected in Star configuration. Short White, Black & Blue wire & then insulate properly.
Wiring Diagram For Three Phase Blower
To change the direction, interchange any two wires between U, V & W. For 230 V 3 Ph supply, wires are connected in Delta Configuration.
Specifications
Model | Supply Voltage | Frequency Hz |
Current A |
Speed RPM |
Max Air Flow CFM |
Max Static Pressure | Capacitor μF | |
Pa | mm of H2O | |||||||
CB 1255 W | Single Phase 110V | 60 | 0.9 | 2600 | 240 | 300 | 30 | 6 |
CB 1255 X | Single Phase 230V | 50 | 0.4 | 2600 | 240 | 285 | 29 | 1.85 |
CB 1255 Y | Three Phase 230V | 60 | 0.5 | 2600 | 240 | 300 | 30 | - |
CB 1255 Y | Three Phase 415V | 50 | 0.2 | 2600 | 240 | 285 | 29 | - |
Air Flow Vs Static Pressure
Dimensions
Wiring Diagram
Wiring Diagram for Single Phase Blower
Ensure that impeller is rotating in counter clockwise direction. Airflow is maximum.
Short Black wires & connect the capacitor as shown. To change the direction, connect the supply wire from White to Red.
Wiring Diagram
Red wires are for running winding & Black wires are for starting winding. To Change the direction, interchange Black wire or Red wire.
Wiring Diagram For Three Phase Blower
To Change the direction, interchange any two wires between U, V & W. For 415 V supply, wires are connected in Star configuration. Short White, Black & Blue wire & then insulate properly
Wiring Diagram For Three Phase Blower
To change the direction, interchange any two wires between U, V & W. For 230 V 3 Ph supply, wires are connected in Delta Configuration.
Additional Information:
Payment Terms : L/C, D/A, D/P, T/T, Western Union,
Delivery Time : 3 Days
Specifications
Model | Supply Voltage | Frequency Hz |
Current A |
Speed RPM |
Max Air Flow CFM |
Max Static Pressure | Capacitor μF | |
Pa | mm of H2O | |||||||
CB 1040 W | Single Phase 110V | 60 | 0.4 | 2800 | 100 | 100 | 24 | 2.5 |
CB 1040 X | Single Phase 230V | 50 | 0.2 | 2400 | 100 | 100 | 20 | 1 |
CB 1040 Y | Three Phase 230V | 60 | 0.2 | 2800 | 100 | 100 | 24 | - |
CB 1040 Y | Three Phase 415V | 50 | 0.1 | 2400 | 100 | 100 | 20 | - |
Air Flow Vs Static Pressure
Dimensions
Wiring Diagram
Wiring Diagram for Single Phase Blower
Ensure that impeller is rotating in counter clockwise direction. Airflow is maximum.
Short Black wires & connect the capacitor as shown. To change the direction, connect the supply wire from White to Red.
Wiring Diagram
Red wires are for running winding & Black wires are for starting winding. To Change the direction, interchange Black wire or Red wire.
Wiring Diagram For Three Phase Blower
To Change the direction, interchange any two wires between U, V &W. For 415 V supply, wires are connected in Star configuration. Short White, Black & Blue wire & then insulate properly.
Wiring Diagram For Three Phase Blower