Post Buy Requirement
SE

Swan Environmental Pvt.Ltd.

Add Review

Our Products

  1. Computer Monitor 6 Products available
  2. Surveillance Systems 4 Products available
  3. Measuring Instruments & Equipment 3 Products available
  4. Elemental Analyzer

    2 Products available
  5. PVC, PP & Plastic Products

    1 Products available
  6. Leak Detectors

    1 Products available
  7. Combustion Equipment

    1 Products available
  8. Laboratory Equipments

    1 Products available
  9. Others Products 25 Products available

Other Products / Services

Our product range contains a wide range of BTEX MONITORING SYSTEMS, AIR MONITORING SYSTEM, HYGIENE MONITORING DEVICE, NOISE MONITORING SYSTEM and Sterility Test Isolator

Particle Counters

Applications
  • Cleanroom verification
  • Clean Bench verification
  • Filter Testing
  • Facility Certification
  • Food Process Investigation
  • Hospital Surgical Room
  • Description

    • Handheld 2.83 LPM (Model 3886)
    • Portable Monitor 50LPM (Model 3910) / 28, 3 LPM (Model 3900)
    • Continues Monitor 2.83 LPM (Model 3714/3715)
    • Smallest and lightest portable particle counter in the industry (Model 3910)
    • Simultaneous measuremnt and display of 6 particle sizes
    • 0.3 micron sensitivity
    • 21 CFR part 11 compliant
    • Measures multi - parameters, air velocity, relative humidity, temperature, pressure
    • Meets ISO 14644-1, Federal standard 209 E, British Standard 5295 and EU-GMP
    • Measures multi -parameters, particle air velocity temperature, humidty, differential pressure
    • Multi-function, user -friendly monitoring software
    • 1PC system controls upto 128 sensors

    Benefits
    • Featherlight with an ultra-small footprint
    • Large Color Touch Screen
    • Multi-parameter: Particle, Airflow, Temperature, Humidity, Differential Pressure
    • Mulit-standard mode: ISO 14644, FS 209E, BS 5295, EU GMP
View Complete Details

BTEX MONITORING SYSTEMS

Applications

  • Petrochemical Industries
  • Traffic Pollution Monitoring

Description

Some VOCs like 1, 3 butadiene or benzene are known to be carcinogenic. The French ministerial recommendation (DGS / SD 7 B no 2005-273 of February 25th, 2005) relating to the evaluation of the consequences on health of air pollution due to traffic showed that those two compounds are critical. In petrochemicals, these compounds are also closely monitored.

Today, we offer a new option for the simultaneous analysis of 1, 3 Butadiene and the BTEX Benzene, Toluene, Ethylbenzene, Xylene) with the analyser. These instruments enable also to separate two interfering species : Cyclohexane (car traffic) and Styrene (petrochemicals).

Features:

  • Validated by the US EPA
  • Option chlorobenzene(s)
View Complete Details

FILTERS FOR STANDARD PROBES

Description
Filter carriers protect the humidity and temperature sensors against mechanical damage. Filters act as a protective barrier against contaminants/pollutants that can infl uence the sensor. When choosing the correct combination of fi lter carrier and fi lter there are many factors to consider. Specifi c conditions such as high air velocities, pollutants in the air, disinfection and cleaning measures, mechanical impacts, high bioactivity, condensation, airborne chemical contaminants and required response time are some of the many considerations.
View Complete Details

Agar Media Dispenser

Description
Autoclavable container: made of borosilicate glass and other autoclavable materials
  • Ideal for sterilization and subsequent distribution of agar
  • Dispensing volumes adjustable by dispensing pump
  • Airtight lid
  • After sterilization, upon reaching dispensing temperature, the desired volume of agar is dispensed to Petri dishes, tubes or vials simply by depressing the dispensing piston
  • Silicone tubing and cannula for dispensing in Petri Dishes, vials and test tubes avoiding the formation of air
  • A magnetic drive may be placed in the container to keep the agar Constantly agitated
  • Maximum capacity 2.5 litres
  • Port for addition of thermolabile substances after sterilization
  • Dehydrate medium and water are added direc to Agarfill container
View Complete Details

HYDROGEN PEROXIDE VAPOUR (HPV) GENERATOR

Applications
  • GMP cleanrooms
  • Aseptic processing
  • Biologics
  • Biomedical
  • Biosafety/security
  • Description
    • Large scale room/zone bio-decontamination
    • Parametric cycle control
    • Simple to operate plug and play system
    • Excellent material compatibility including sensitive electronics
    • Dual circuit technology for optimum cycle times
    • Gas distribution catalytic aerator included
    • Siemenscolour touch screen
    • GAMP compliant software
    • Compact and highly portable design
    • Easily cleanable external surface
    • Volt-free contacts for external signals
    • Integral thermal paper printer
    • Remote start/stop
    • Unique Bioquell parametric control process no need for gas cycle development
    • Cycle edit and store facility for new applications
    • Effective against a wide range of micro-organisms
    • Hydrogen peroxide vapour gas sensor
    Safe and simple to operate:
    • The control lectern is removed from the Bioquell Z-2 at an appropriate control point; the Bioquell Z-2 is then placed inside the contaminated zone
    • With the lectern in place outside the area to be decontaminated, the area is sealed with tape and any ventilation systems are isolated
    • Room dimensions are entered allowing the Bioquell Z-2 to calculate HPV cycle parameters. Final safety checks are made via the control panel on the lectern. The cycle can then be activated
    • Multi-directional nozzles deliver the vapour, switching to automatic aeration (via parametric control) after the gassing phase is complete
    • The touch screen displays the cycle progress and indicates when the cycle is complete
    • At the end of the cycle, HPV levels are manually checked from outside the room and the area is then rapidly put back into service
View Complete Details

Autoclaves

Applications
To meet the sterilization requirements in:
  • microbiology
  • medicine
  • podiatry
  • tattooing
  • body piercing
  • veterinary science
  • mycology
  • dentistry
  • prostheticsfabrication.
  • Description
    Autoclave, VWR VAPOUR-Line lite:

    AISI 340 stainless steel housing, easy to maintain and disinfect, aluminium inner chamber and ABS insulating lid with locking system.
    • Microprocessor controlled automatic thermoregulation
    • Digital temperature and sterilisation time display
    • Automatic ventilation valve and electronic temperature cut-off safety protection system
    • Reinforced heating element and PT100 accurate thermoprobe
    • Automatic sterilisation programmes
    • Instructions are GLP and EN 17205 compliant.
View Complete Details

Microbial Air Sampler

Applications
  • Clean Room
  • Isolator
  • Agro, Food, Dairy, Beverage Production sites
  • Microbiological Laboratory
  • Biotechnology Premises
  • Vaccine Production Plant
  • Waste Water Treatment Plant
  • School, University training and teaching
  • Hospital & Clinics
  • Indoor Air Quality
  • Public Health Authorities
  • Description
    DUO SAS SUPER 360:


    When the environment contamination is very low and the number of samples to be performed is high, the duration of the operations can be an important factor in the choice of SAS instrument. With two sampling heads that can operate simultaneously, DUO SAS 360 is the correct solution to sample 1000 L of air in less than 3 minutes.

    Features
    • Single body with two aspirating heads: two separate plates may be used for simultaneous sampling to differentiate microorganisms (onto two different media) or onto the same media
    • To calculate an average value and to obtain a more representative result
View Complete Details

SONIC WEATHER STATION

This AIO 2 integrates a unique low-power sonic anemometer, the Sonimometer, with a multi-element temperature sensor, fast-response capacitive relative humidity sensor, state-of-the-art barometric pressure sensor, and an internal flux-gate compass for automatic alignment of wind direction to magnetic north for quick deployment (true/magnetic North offset is adjustable by the user through software command).
The result is a professional grade, next-generation, compact all-in-one weather station designed for reliability, longevity, and ease of installation which can measure temperature, relative humidity, wind speed, wind direction and barometric pressure.
Robustness:
The small footprint and power efficiency of the AIO 2 make it ideal for remote regions, urban environments, air quality networks, construction/remediation sites, and other network applications.
Portability:
Designed for maximum portability and utility, the AIO 2 is uniquely applicable for rapid deployment
and use by one person under all conditions. The unit may be mounted on a tripod or vehicle mast.
Data logging:
Data output is a serial, digital message that can be interfaced to most data logging systems. Software is provided for user interface. Options are offered for wireless communication.
Accessories:
Carrying cases, compact quick deploy lightweight tripod and external power options.
Features:
All-In-One Measurement of Temperature, Relative Humidity, Wind Speed, Wind Direction & Baro-metric Pressure
Integrated Sonimometer Wind Sensor
Automatic Wind Direction Alignment to Magnetic or True North
Rugged, Reliable, Quick to Deploy
All Metal Construction
Weather Protected Multi-Sensor Design
No Moving Parts
Low Power Consumption
Digital Output
Proven Field-Use History

Applications
The most powerful package for optimizing your irrigation and Integrated Pest Management (IPM) decisions.
View Complete Details

TOTAL ORGANIC CARBON (TOC) ANALYZER

Applications
Measurement of TOC in purified water as per USP/EP and water for injectibles as per USP/EP/IP/JPWater purification plant validationValidation of water distribution systemMeasurement of TOC in Raw water / Feed waterCleaning Validation
Description
The TOC-L series of TOC analyzers adopts the 680C combustion catalytic oxidation method, which was developed by Shimadzu and is now used worldwide. While providing an ultra wide range of 4 g/L to 30, 000 mg/L, these analyzers boast a detection limit of 4 g/L through coordination with NDIR. This is the highest level of detection sensitivity available with the combustion catalytic oxidation method. In addition, the combustion catalytic oxidation method makes it possible to efficiently oxidize not only easily-decomposed, low-molecular-weight organic compounds, but also hard-to-decompose insoluble and macromolecular organic compounds.

Features
Extremely wide measurement range from 4 g/L to 30, 000 mg/L, applicable to everything from ultrapure water to highly contaminated water TOC-LCSH/CPH
  • Capable of TC, IC, TOC (= TC-IC), and NPOC measurement; options enable POC (volatile organic carbon), TOC via POC + NPOC, and even TN (total nitrogen) measurements
  • The blank check function evaluates system blanks by measuring ultrapure water processed automatically within the instrument
  • The automatic dilution function enables measurements up to 30, 000 mg/L
Reliable sample injection system
  • Automatic sample acidification and sparging
  • The automatic dilution function reduces sample salinity, acidity, and alkalinity, significantly extending the period of use of catalysts and combustion tubes (The period of use depends on the sample and measurement conditions.)
  • Stat or priority samples can be added at anytime to the analysis schedule without interrupting operation even when an autosampler is used
Select from 4 models to suit your application
  • The TOC-L series consists of a high-sensitivity model with a detection limit of 4 g/L, making it suitable for a variety of applications, including pure water measurements, and a standard model designed with cost performance in mind. Each analyzer is available as an LCD and keyboard-equipped standalone model, or as a PC-controlled model.
  • In addition, the USB format has been adopted as the external interface, enhancing the equipments versatility. Even the standalone models are capable of output to a general-purpose PC printer or to a USB memory stick.
Options to further enhance functionality
  • With the TOC-L series, numerous options enable a variety of functional enhancements. These include simultaneous measurement of TOC and TN (total nitrogen) (when a TN unit is added), the use of compressor air (when a carrier gas purification kit is added), and the measurement of gas samples and solid samples (when a gas sample injection kit and solid sample combustion unit are added).
  • Sea water sample measurement and small sample volume options have also been enhanced.
Space-saving and energy-saving design
  • The width of the instrument is 20 % less in comparison with conventional Shimadzu models. This enables more effective use of laboratory space. The instrument width is unchanged even when the TN unit is added.
This product conforms with Shimadzus ECO labeled product. Energy Saving: Power consumption reduced by 36 % (100 V) and 43 % (200 V) as compared to a conventional Shimadzu product. (Assuming 8 hours operation/day 5 days/week)
View Complete Details

Gas Leak Detector

Applications
The GasCheck G gas leak detector detects gases across a wide range of industries and applications, including:
  • Industrial
  • Refrigeration
  • Manufacturing
  • Quality Assurance
  • Laboratory
  • Medical
  • Research
  • Aircraft / wing tank entry
  • Automotive Manufacture
  • Fugitive Emissions
  • Gas Line Leakage
  • GIS Leakage
  • Sileage silos
  • Solvents in Clean Rooms
  • Description
    GasCheck G - Gas Leak Detector for Rapid, Accurate Gas Leak Measurement:
    The GasCheck G gas leak detector represents the latest in gas detection technology. Its advanced system of micro thermal conductivity enables improved sensitivity for the rapid, effective detection of gas leaks down to cc/sec, mg/m or ppm levels.
    Designed for the search and location of gas leaks, the GasCheck G leak detector provides you with effective detection of almost any gas or gas mixture. Robust and reliable, the GasCheck G leak detector gives stable, repeatable readings of the detected gas. The instruments LCD display, LED indicator and audible sounder clearly indicate the leak present.
    The GasCheck G leak detector automatically zeros to the ambient air around it when switched on and is ready to detect immediately. The instruments easy to use graphical interface and intuitive keypad allows for simple function, selection and adjustment.
    Upgradeable throughout the range, the GasCheck G gas leak detector is available in three distinct versions; G1, G2 and G3 with varied capabilities. Features can be easily added to upgrade the instrument without it having to be returned to the factory.
    Features
    • Micro Thermal Conductivity Sensor for enhanced sensitivity
    • Three variants available; G1, G2, G3
    • Choice of reading in cc/sec, mg/m or ppm
    • Graphical icon display menu for international markets
    • Rapidly detects almost any known gas or gas mixture particularly sensitive to ammonia, argon, butane, helium,
    hydrogen, SF6
    • Reliable, stable and repeatable readings
    • Conveniently calibrated against helium
    • LCD back lit display
    • Hand held and robust
View Complete Details

Colony Counter

Applications
Total number of colonies, Enterobacteria, nutrient disks and filter disks, chromogenic agar, high number of colonies (up to approx. 1.000 per Petri dish), bacteriophage plaque assay, inhibition zones and dark agar.
Description

High throughput analysis of bacterial colonies or bacteriophage plaques in less than a second. The schuett colonyQuant is comprised of a CCD-Firewire camera (colour) with autozoom and autofocus, a light-proof sample chamber and the software for automated colony counting.
Differentiation by colour, size and shape to be combined at choice by the user. Additional features allow for separating overlapping colonies. Settings to be stored and retrieved via mouse-click for future analysis of similar type samples. The system is straightforward to use and the software is Windows based. Results are presented as an image on your monitor or in a table exportable to Excel.
Unique to the schuett colonyQuant is its ability:

  • to process up to 400 Petri dishes per hour with up to 1.000 counts per dish.
  • accurate detection of difficult to identify colonies.
  • mixed cultures - differentiation of colonies with up to 8 colours simultaneously.
  • changeover from evaluating agar plates or to nutrient discs, to spiral plates, to inhibition zone analysis etc. can be effected by a simple mouse click.

The system has been designed for use with Petri dishes of 60 and 90 mm diameter. As a result of using a LED-array to illuminate the surface of the agar circular from the side a hereto unknown transparency and sharpness for detecting colonies can be observed.

Features

  • Software for selection according to colour, size and shape
  • Light-proof sample chamber with camera (colour), Live-image and circular LED-illumination
  • Image acquisition and simultaneous evaluation within seconds
  • Tables and images may be stored digitally, results for each counted colony reviewable
  • Agar plates, nutrient disks, plaque assays, Inhibition zone analysis, Spiral plating
  • Mixed cultures, separates up to 8 colours simultaneously
  • Sectorial evaluation, 90% option
View Complete Details

Combustion Analyser

Applications
To optimize any combustion process in order to comply with ambient air laws applicable for various industries.
Description
Professional flue gas analyser that combines high quality of sample conditioning with great measurement accuracy contained in a compact soft casing.
Analyser is equipped with heated hose with heated filter, built-in high efficient condensation dryer.
It can be fitted with up to 9 sensors (electrochemical cells and NDIR sensors).
Has built-in pressure sensor, large internal memory for results and built-in ribbon printer for standard(non-thermal) paper.

Features

  • Equipped with up to 7 electrochemical cells
  • Equipped with up to 2 NDIR sensors
  • Built-in 58mm ribbon, graphic printer
  • Built-in rechargeable battery for up to 8 hours of operation
  • Built-in Peltier dryer with peristaltic pump for condensate removal
  • Equipped with heated hose with built-in heated gas filter
  • Heated hose with standard M30x1 fitting, fits all madur gas probes with K-type thermocouples
  • Additional gas filter with condensate trap
  • Differential pressure sensor - for measurements of chimney draft and flow velocity (with help of Pitot tube)
  • Soot measurement program
  • Measurements of gas and ambient temperatures, optionally 2 additional inputs for temperature sensors
  • Analogue outputs (4-20mA / 0-10V) - optional
  • Built-in large memory for results, two formats of data savings
  • Calculations of many additional parameters
  • Firmware for gas calibrations
View Complete Details

COMPRESSED AIR QUALITY MEASUREMENT SYSTEM

Applications
To meet the compressed air quality standards in:
  • Pharmaceutical Industries
  • Food Industries
  • Description
    • For Oil Mist, Water Vapour, CO, CO2, NO+, NO2, H2S, SO2
    • Mandatory as per USP - NF 24, EP 4-2.1.6, IP-2.1.1 and BP-2.1.6
    • Based on color change detector tube

View Complete Details

AIR MONITORING SYSTEM

The On-Line Continuous Ambient Air Monitoring Station is used for the measurement of PM10& PM2.5, CO, SO2, NOx& O3in the ambient environment. It is CPCB / USEPA approved and meets thelatestspecifications of National Ambient Air Quality Standards.

Applications

To maintain the air quality as per the prescribedNational Ambient Air Quality Standards.
View Complete Details

Colorimetric Gas Detection Tubes

Applications
Fire & Rescue ServicesOil Refining PlantsChemical PlantsMarine & Shipping TechnologiesMining & UndergroundLaboratories & Schools
Description
Offers quick on-the-spot measurement of various gases and vapors. The tubes are available for over 500 gases, easy to read, with a sharp & clear color change and proved accuracy with no need for calibration.

View Complete Details

HYGIENE MONITORING DEVICE

Applications
  • Food processing plants
  • Breweries especially for beer
  • Processed meats
  • Frozen seafood
  • Beverages
  • Dairy plants
  • Personal care
  • Healthcare
  • Yogurt and soya milk manufacturers
  • Description

    ATP pens are designed specifically for measuring contamination on surfaces. As you knowwherever food residue is present, there is a risk of microbial contamination. While culture tests can detect the presence of microorganisms, ATP tests also detect the presence of food residues and therefore provide a more complete indicator of risk.

    Kikkoman Lumitester PD - 30 & LuciPac Pen is a unique system, tool measurement with the patented recycling technology platform that enables detection of enzymatic roprietary ATP (adenosine triphosphate) and biological degradation products of ATP is ADP (adenosine diphosphate) and AMP (adenosine monophosphate) .

    Kikkoman PD-30 is the only one patented instrument to measure both ATP+AMP

    Lumitester PD-30 and LuciPac-Pen is a system that is simple, accurate, and provides important information that is needed to run the monitoring process efficient and effective sanitation costs

View Complete Details

NOISE MONITORING SYSTEM

Applications
To measure the ambient environmental noise.
Description
Noise Monitoring System is a fully integrated solution for unattended noise monitoring applications featuring an internal web server for system configuration, live data streaming, data management and battery powered operation providing true flexibility for both short and long term measurements
The measurement capabilities are optimized for noise monitoring applications . It measures and stores results suitable for automatic automatic reports, detailed information for advanced post-processing analysis and streams live data stream for real time noise monitoring.

SV 200

SV 200 Noise Monitoring Station is a fully integrated solution for unattended noise monitoring applications featuring an internal web server for system configuration, live data streaming, data management and battery powered operation providing true flexibility for both short and long term measurements.
The measurement capabilities of the SV200 are optimized for noise monitoring applications. It measures and stores results suitable for automatic reports, detailed information for advanced post-processing analysis and streams live data stream for real time noise monitoring. Standard measurement functionality includes multi-profile data logging, real time 1/1 and 1/3-octave logging, audio event recording and statistical analysis. Measuring capabilities can be extended with real time audio streaming and weather condition monitoring. SV 200 can be used for both and 0 and 90 reference direction, typically used for aircraft and environmental noise. The reference direction is user selectable in the instrument configuration.
The weatherproof housing protects SV 200 noise monitoring station against extreme weather conditions while fulfilling class 1 accuracy. Special attention was given to the highly efficient windscreen which reduces noise, even at high wind speeds. Internal heating and rugged a dual layer housing enables the SV 200 to operate from -30C up to +60C and humidity up to 100% RH.
SV 200 has a 2, 45 Ah internal Li-Ion battery and interface for connecting solar panels. A waterproof mains adapter for charging the battery and powering the station is also included. The system is specially designed for easy installation - SV 200 is small, light weight and easy to install by a single person.
The SV 200 is available with an integrated low power 3G modem or Wi-Fi access point. The implementation of advanced and highly reliable communication protocol gives the user full control of the station, offers easy to use data transmission, real time data publication and live audio streaming. Station configuration and data management is done by using a web browser or the SvanPC++ RC server application.

Features

  • All in one design for portable, mobile and permanent noise monitoring installations
  • Real-time 1/1 or 1/3 octave analysis
  • Audio events recording
  • Rugged housing protecting the system against harsh environmental conditions (IP66)
  • Integrated electrostatic actuator for full system verification
  • Class 1 according to IEC 61672
  • Integrated high speed 3G or Wi-Fi modem
  • Automatic time synchronization
  • Large windscreen against high-speed wind
  • Intelligent heater protecting microphone against humidity
  • Live audio & data streaming capabilities
  • Low power consumption, integrated Li-Ion battery and direct connection for solar panels
  • Highly reliable and secure data push and configuration pull communication protocol
  • Both, server and web based system configuration
  • Community & airport characteristics available simultaneously
View Complete Details

Sterility Test Isolator

Applications
  • Sterility Test
  • Hospital Pharmacy
  • Life Sciences research
  • Clinical trails
  • Description
    Modular aseptic processing solution in convenient configurations to meet your workflow
    Air cleanliness ISO 5 and Grade A working environment with integrated Bioquell HPV 6-log bio-decontamination for peace of mind
    Fast cycles and quick turnaround between tests - get more from your day.
    The Bioquell QUBE is a modular aseptic working system consisting of a series of major components :
    • QUBE HPV Module (QHPV) (M1)
    • QUBE Extension Module (QEXT) (M9)
    • QUBE Connecting Interface Modules (Open Connection or Sealed Door) (M11)
    • QUBE Material Transfer Device (QMTD - Right or Left Side) (M2 or M3)
    • Undertake aseptic processing in a Bioquell QUBE, a cost-effective modular aseptic workstation system with built- in rapid bio-decontamination. The combination of uni-directional airflow, an ISO 5 and Grade A working environment and hydrogen peroxide vapour (HPV) rapid bio-decontamination ensures the Bioquell QUBE is suitable for applications such as pharmacy compounding, sterility testing, and many others. Performance is assured by using Bioquell approved hydrogen peroxide solution. The Bioquell QUBE modules allow a variety of configurations that tailor the workspace to the needs of the specific process.
      • Fully validated sterility test unit with built-in biodecontamination system
      • Ergonomically designed using latest manufacturing techniques, Rapid sporocidal bio-decontamination process with high level validated 6-log sporocidal reduction
      • Intelligent modular design provides users flexibility in selecting the suitable configuration for their process
      • Air cleanliness ISO5 and grade A working environment with integrated bioquell HPV 6-log biodecontamination
      • Integrated environmental monitoring for total viable and non-viable practical monitoring.
      Bioquell QUBE with extension module and materials transfer device, ideal for phamaceutical compounding.
      Key features

      A modern ISO 5 Grade A chamber with uni-directional air flow that includes a high definition colour touch panel with intuitive icon driven interface, glove ports with safe change gloves, RFID enabled hydrogen peroxide filling and pneumatic seals with pressure monitoring for repeatable chamber integrity.
      Chamber pressure can be controlled from +100pa to -100 pa and there is a built-in aeration capability with every module for fast decontamination cycles. The system has been engineered to keep noise levels low and a 316 Grade stainless steel level floor has been provided throughout the system along with an integral thermal paper printer to keep a record of the bio-decontamination cycle and key GMP parameters.
      Ergonomically designed, the Bioquell QUBE provides an integrated footrest and foot switches for door activation.It uses novel plastics technology to enable excellent cleanability.

View Complete Details

CONTINUOUS BLACK CARBON ANALYSER

Applications
The BC-1050 is simple, reliable, cost effective and produces defendable BC (Black Carbon) data with high time resolution that may be used for:
Air quality surveillance
Global warming studies
Particulate emissions studies
Near-roadside monitoring
Visibility studies
Features:
1-minute resolution (1-hour default)
1 ng sensitivity
2 channels OC (375 nm) & EC (935 nm) are available
Very inexpensive compared to competing products
16.7 LPM (FRM-like) & 5 LPM configurations available
Std. PM cut point, with PM or other cut points are available
Outputs are virtually identical to competing brands
The Met One Instruments BC-1050 Black Carbon Monitor measures black carbon through optical
attenuation and absorption principles in both the infrared and ultraviolet spectral regions. The BC-1050 offers improved traceability for the measurement of black carbon (BC) compared to traditional filter-based optical techniques through its unique factory calibration process and through the incorporation of standard EPA-style sampling inlets.
This approach, which is based on the method used to both calibrate and operate the Instruments of beta attenuation mass monitors, will both insure an unbiased sampling protocol and improve inter-unit reproducibility of equipment returned for service and redeployment.
Measurement Principle:
As ambient air containing BC is continuously deposited onto optically transmissive filter media, the attenuation of dual IR / UV light sources passing through the collected BC is monitored. This information is stored and subsequently used to calculate both BC and UV-absorbing particulate matter.
Time-resolution is user-selectable with 1-min minimum. The filter advance frequency is user selectable and may be based on either UV or IR absorbance reaching a predetermined level, or based on time (i.e., once each hour).
View Complete Details

INSTANTANEOUS MICROBIAL DETECTION IN WATER

Applications
  • Filling Line Cleaning / Clean-In-Place (CIP)
  • Pretreatment and Reverse Osmosis (RO) Effectiveness
  • Storage Tank Sampling
  • Point-of-Use Sampling
  • Water System Validation
  • Routine Water Sampling
  • Description
    Water Sampling with the IMD-W System: One Method, Many Applications.
    Purified water has many uses throughout the biologics, pharmaceutical, and medical device industries from cleaning equipment after manufacturing, to heating and cooling for sterilization and sanitization, to providing the base constituent of life-sustaining therapies. Because of the many uses for highly purified water, there are many ways to use the IMD-W system, an instantaneous microbial detection system for pharmaceutical grade waters.

    Flexibility to Meet All of Your Application Needs:On-line, At-line, and In Laboratory.
    The IMD-W system has been designed specifically with flexibility of use in mind. The system may be used in a laboratory setting for the testing of individual samples, and also can be placed online for continuous monitoring.

    Benefits

    • Improved product quality
    • Better risk management
    • Enhanced process understanding
    • Energy savings
    • Improved resource allocation and labor efficiencies

    Features

    • Real-time results without staining or reagents
    • Detects particles and determines biologic status simultaneously
    • Enhanced interferent discrimination
    • Built-in purge and cleaning processes
    • Automated sample collection
    • Automated system suitability routine
    • 21 CFR Part 11 compliant
    • Integrated touch screen user interface
    • Data may be exported for offline analysis and storage
    • Flexible communications interface for networking; can be controlled externally by common industrial control systems (e.g. SCADA, PLC)
View Complete Details

PORTABLE AEROSOL MOBILITY SPECTROMETER

Applications
  • Personal Nanoparticle/Aerosol Exposure Measurement
  • Workplace protection factor measurement of respirators
  • Atmospheric process studies
  • Air pollution and air quality measurements
  • Combustion and engine exhaust emission measurements
  • Filtration studies
  • Inhalation toxicology studies
  • Indoor air quality studies

Description

PAMS is an electrical mobility size spectrometer designed for portable, mobile, or handheld aerosol sampling applications. It provides the number-weighted diameter distribution of aerosols over the entire submicrometer range (10 to 863nm) in one scan. The unit uses a nonradioactive bipolar aerosol charger to allow easy access to sampling sites with tight safety regulations. Its bipolar charger significantly reduces measurement uncertainty of larger particles in the submicrometer range.


Features:
  • Electrical mobility size spectrometer designed for portable, mobile, or handheld aerosol sampling applications
  • Provides number-weighted diameter distribution of aerosols over the entire submicrometer range (10 to 863nm) in one scan
  • Uses a non-radioactive bipolar aerosol charger to allow easy access to sampling sites with tight safety regulations
  • Bipolar charger significantly reduces measurement uncertainty of larger particles in the submicrometer range
  • Can be used in two modes: Single diameter count mode: to get a total count within a narrow size range or Size
distribution mode: to get an automated size distribution measurement over desired size range or size resolution
  • Stand-alone, battery-operated instrument; no external computer needed.
  • Weighs only 4.5 kg and measures 23 x 23 x 15 cm.
View Complete Details

ELECTRICAL LOW PRESSURE IMPACTOR

Applications
  • Combustion studies
  • Air quality measurements
  • Occupational health and safety studies
  • Automotive exhaust measurements
  • Blow-by gas measurements
  • Particle charge distribution measurements
  • Pharmaceutical inhaler studies
  • Filter grade efficiency studies
  • Nanotechnology
  • Description
    ELPI+ :
    ELPI+ (Electrical Low Pressure Impactor) is an improved version of the widely used and well characterized ELPI -system. ELPI+ enables measurement of real-time particle size distribution and concentration in the size range of 6 nm 10 m with 10 Hz sampling rate. The ELPI+ features include real-time stand-alone operation, wide sample concentration range, wide particle size range and robust structure for operation even in harsh conditions. In addition to gaining real-time particle size distribution data, the ELPI+ can be used for real-time particle charge distribution and for gravimetric impactor measurements. The use of impactor technology also enables post-measurement chemical analysis of size classified particles. All these features make the ELPI+ and ideal choice in wide range of particle measurement applications including combustion aerosol and engine exhaust studies, pharmaceutical inhaler development, air quality monitoring and general aerosol research.
    Features:
    • Wide particle size range; 6 nm 10 m
    • 14 particle size fractions
    • 10 Hz sampling rate
    • Possibility to collect size classified particles for chemical analysis
    • Wide operational concentration range
    • Independent stand-alone operation or control via laptop using ELPI+VI software
    • Large 7" WVGA display with graphic user interface
    • Analogue inputs and outputs
View Complete Details

PORTABLE FTIR GAS ANALYSER

Applications
Stack testing according to USEPA methods 320 and 321 or European standards

Process monitoring

Formaldehyde emissions monitoring from biogas plants: VDI 3862 Blatt 8:2014-01

Stack testing according to British Technical Guidance note M22: Measuring stack gas emissions using FTIR instruments, Environment Agency, Version 3, March 2012

Reduction of greenhouse gas emissions by cattle -research
Description
Gasmet DX4000 is a portable FTIR gas analyzer which is typically used in stack emissions monitoring, comparison measurements, catalytic process control and other applications where multiple gas compounds need to be accurately monitored in hot & humid sample gas. The corrosion resistant sample cell is heated to 180 C, which ensures that the sample stays in gaseous phase even with high concentrations of H2O or corrosive gases.
Gasmet DX4000 comes equipped with easy-to-use Calcmet software, which can display the concentration results in ppm, mg/Nm3or Vol-%. All measurement data can be stored for further analysis.
Gasmet DX4000 is typically set-up to measure H2O, CO2, CO, NO, NO2, N2O, SO2, NH3, CH4, HCl, HF and different VOCs. Additional gases can be added without any hardware changes. Measurement ranges can be selected from sub-ppm until vol-% level.
Gasmet DX4000 can be supplied with the Gasmet portable sampling system. This system utilizes hot-and-wet measurement principle (no drying or dilution), which ensures that the analysis is done with a representative sample. There are two stage particulate filtration: first one in sampling probe (2 m) and second one in sampling system (0.1 m).
The portable sampling unit can be optionally equipped with a ZrO2sensor for accurate oxygen measurement.
Gasmet DX4000 has received the coveted MCERTS certification for stack emissions monitoring. There is also VDI 3862 standard for measuring formaldehyde emissions from biogas plants in Germany.

Key Advantages:
  • Easily configurable application for new gas components
  • Post-measurement data processing tools are unique to Gasmet
  • Wide range of applications
View Complete Details

MERCURY VAPOUR INDICATOR

Applications
  • Manufacturing
  • Recycling
  • Fluorescent lamp reprocessing plants
  • Mining
  • Petroleum
  • Hydrocarbon
  • Refining
  • Bioremediation
  • Gold mining
  • Illegal Dumping of Chemicals
  • Mercury Clean Up
  • Description
    Mercury Detector Accurately Detects Vapours in just 3 seconds!
    No Saturation, No Regeneration - Eliminating Instrument Downtime
    The Mercury Vapour Indicator (MVI) is a revolutionary mercury detector, detecting mercury vapours in just 3 seconds! The instruments dual beam UV absorption technology means MVI does not saturate or need regenerating between readings - like traditional gold film detection methods - eliminating instrument downtime. Fast and accurate, the MVI mercury detector gives a real time response and is ready to detect instantly. MVI provides continuous readings and offers two detection ranges: 0.1 to 200 and 1.0 to 1999 microgram/cubic meter.
    MVI is a portable mercury vapour detector that utilises a high performance pump for fast indication and recovery. The instruments audible alarm and large digital display clearly indicate the levels of mercury present.
    Ergonomically designed with simple, one handed operation MVI mercury vapour detector is the ideal survey unit for rapid and accurate mercury detection.
    Features
    • Dual beam UV absorption technology
    • No saturation, no regeneration eliminates instrument downtime
    • Fast, 3 second response
    • Range: 0.1 to 200 and 1.0 to 1999 microgram / cubic meter
    • Highly accurate measurement
    • Continuous 6 hour operation
    • High performance pump for fast indication and recovery
    • Ready to detect within minutes
    • PTFE probe with moisture trap filter
    • Large digital display
    • Simple, one-handed operation
    • Audible alarm
    • Robust and portable
View Complete Details

BUNSEN BURNER WITH GAS

Description

Safety Bunsen Burner for lab tasks such as sterilizing, heating or scarfing.

  • Ideal for use in microbiological safety cabinets or in the chemical laboratory.
  • Housing made of polished stainless steel and safety glass. UV- and solvent resistant, flame-sterilizable, easy to clean.
  • Suitable for use with natural gas (central gas supply in the lab) or propane/butane gas (mobile with gas cartridges/bottles).
  • Easiest exchange of burner head, no need for tools.

Features

Schuett Phoenix II with highest safety standard (certified according to DIN 30665 part 1, DIN-DVGW Reg.NG-2211AR0750):

  • Controlled burn-time 1 sec 120 min (adjustable)
    • Burn-time displayed in all modes of operation
  • Automated safety shutdown if not in use
  • Sensor activation 1x/2x
  • Overheating protection/burner control by sensors,
    • e.g. temperature of the burner head (Warning remark in the display)
  • Exact economic flame adjustment
  • Stable flame, even at strong currents
  • Flame and ignition monitoring
  • Tilting to the right or to the left side.

Benefits

Unique comfortable Bunsen Burner with outstanding quality features:

  • Easy-to-read highlighted colour display
  • Multilingual menu navigation in most international languages
  • Information and warning remarks in written form
  • Self-explanatory operation
  • Unique joystick navigation
  • Gas and air adjustment with Click-Stop-feature
  • Comfortable operation optionally by hand, foot-switch or motion sensor mode

Schuett phoenix II eco(without display/sensor, with foot-switch)Start/stop flame by foot-switch or press button by hand (ON/OFF).Low-cost model, best suited for microbiological safety cabinets.

Schuett phoenix II standard(colour display, language selection, sensor and foot- switch)Start/Stop flame by activating sensor 1x/2x, use foot switch or press button by hand (ON/OFF). Burn-time displayed.
Schuett phoenix II accu(colour display, language selection, sensor and built-in high-power battery)Start/stop flame by activating sensor 1x/2x, use foot-switch or press button by hand (ON/OFF). Burn-time and battery status displayed. Built-in high-power battery for up to 30 hours operating time. With high-speed battery charger incl. overcharge protection. Ideal for mobile operation.

View Complete Details

TUBULAR CENTRIFUGES

Applications
Purification of Fuel Oils for emergency power generators
Purification of Lubricating Oils
Purification of Rollin Oil, Quenching Oil and Hydraulic Oil
Purification of Waste Oil
Removal of foreign matters from lost-wax
Clarification of lacquer and solvent type paint.
"Solid-Liquid" separation of resin and slurry containing organic solvents
Recovery of catalyses
Pressurized "Solid-liquid" separation of heavy oil and waste plastics at high temperature.
TRV Decanters play a majot role in the PET plants.
Description
Many TSM Decanters are employed in he sludge volume reducing process of the wastewater treatment plants. They are also installed in feces, garbage and cattle-stall effluent treatment plants. TSM stands for the Triple-Saving Machine. It reduces maintenance labor, power consumption and flocculant consumption.
Features
  • Compactly built machine
  • Low Noise:The optional cover reduces it further down to 80dB or less
  • Easy and Quick Installation:limited number of anchor bolts
  • Little Power Consumption:20-40% less than the conventional ones
  • Wear resistive tile chips on the screw conveyor flight:less spare parts and less repair expenses
  • Both the TSM dewaterer and thickener accomplish high solid recovery.
  • As the liquid collecting cover and the discharge port are separated, this unit can be disassembled without disconnecting the liquid piping's from the unit.
View Complete Details

RAPID & NON - DESTRUCTIVE GROWTH DIRECT SYSTEM

Applications
    • Environmental Monitoring
  • Sterility Testing
  • Bioburden Testing
  • Description
    The Growth Direct System consists of an automated imaging instrument that analyzes user-prepared proprietary consumables called Growth Cassettes. The system and consumables were designed to optimize test performance and ease-of-use. In addition to rapid enumeration of microbes compared to the culture method, a major attribute of theGrowth DirectSystem is the automated handling and analysis capability that reduces hands-on time required by technical staff.
    • The growth direct system is the first and only automated system that addresses all key microbial QC applications like sterility, environmental monitoring water and bioburden
    • Rapid micro biosystem's growth direct test uses digital imaging technology that automatically enumerates micro colonies days earlier than the traditional plate methods
    • The system captures the fluroscence (autofluroscence) that is emitted by all living cells
    • A positive result will be available within hours and a final result in about half the time of the compendial test
    • The system monitors tthe internal opeations of incubators including tempearatutre humidity and capacity
    • Growth direct automatic detection methods can minimize manual errors and ultimately reduce expenses
    • For sterility testing the system ensures the oxygen free status of the anaerobic sample
    • Different incubation temperatures can be programmed in single unit
View Complete Details

RAPID BIO-MASS DETECTION SYSTEM

Applications
  • Measurement of Adenosine Triphosphate (ATP) to obtain a complete microbial quantitative measurement.
  • True and rapid measurement of total living organisms
  • First line of defense for microbiological thretats control in all type of fluids like potable / raw water / purified water measurement
  • Prominent tool to identify the source of bio burden in purified water
  • Validation of water distribution points
  • Second generation ATP allows to be appiled to essential any application where microbial growth is of concern
  • Real time microbial monitoring leads to more productivity/profitability
  • Description
    Luminultra 2ndgeneration ATP test kits developed for rapid determination of microbial population of almost all fluid samples from drinking water to industrial process water, chemical products and waste water.ATP Bioluminescence assay is the best solution to overcome the traditional method problems. Because of its speed and specificity to biological activity, ATP measurement can play a key role in defending against failing drinking water quality, including those encountered during routine operation.
    Advantages
    • It is fast results are available in a matter of minutes rather than days
    • It is complete since ATP is present in all cells, it provides a direct indication of the total microbial population.
    • It is portable the test can be performed reliably in the field, thereby eliminating sample transportation and processing times, providing on-the-spot results for real-time troubleshooting.
    • Immediate investigation to solve the incursions to save time costs and reduce risk
    • To release the production immediate without wait for seven days culture test result
    It is the first line of defense in identifying threats, after which follow-up testing to identify problematic species can be undertaken. This is a tremendous advantage which allows operators to take immediate action to solve microbiological build-ups or incursions to save time, costs and reduce risks and you need not to wait for traditional seven days results to release the batch of bottles after getting fast and immediate results from ATP method.
    Features
    • First line of defense for microbiological threats control in all type fluids like drinking water/waste water, Upstream oil and gas, metal working fluids, chemicals, personal care products.
    • Measurement of Adenosine Triphosphate (ATP), obtain a complete and fully-quantitative measure of total microbial content in less than 5 minutes.
    • It measures true total bioburden
    • Second generation ATp allows to be applied to essential any application where microbial growth is of concern.
    • Luminultra technology is rapid, accurate, complete, quantitative and reliable
    • Real time feedback increases productivity and profitability
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us