Our Products
Measuring Instruments & Equipment
2 Products availableGas Analyzers
1 Products availableLeak Detectors
1 Products availableFilters
1 Products availableData Loggers
1 Products availableWe offer the best product range of TURBIDITY METER.
Industry-leading precision, sensitivity, and dependability in one of the most innovative handheld turbidity meters available on the market! NOW WATERPROOF!
The multi-detector optical configuration assures long term stability and minimizes stray light and color interferences. All turbidity readings are determined by the process of signal averaging over a 5 second period. This minimizes fluctuations in readings attributed to large particles and results in rapid, highly repeatable measurements. Ideally suited for both low-level drinking water applications as well as monitoring high turbidity in the field.
Benchtop Model:ROTRONIC provides a high-end laboratory device the HygroLab C1 for water activity measurements with up to four probes. Connect station probes and insertion probes for measuring water activity in cheese, meat, tobacco, building materials, animal feed, pharmaceuticals products and much more.
Validated softwareEasy-to-use and intuitive, the laboratory grade indicator can be used by anyone. HW4 running on a PC provides remote monitoring with charting and data recording functions.
Portable Model:In many situations it can be very useful to measure water activity in production or storage rooms, e.g. inspection of bulk materials to ensure they meet specifications.
The Quantek Model 905V is a pharmaceutical headspace oxygen analyzer. Use it for headspaceoxygen analysis in pharmaceutical products vials, blister packs, or bottles. Achieve results with as little as 0.5cc of headspace.
Pharmaceutical preparations packaged in vials are often gas-flushed to provide a specificatmosphere in the vial, with defined levels of oxygen, nitrogen or other gases. Depending onthe product, these vials can range in size from 1 ml to 250 ml or larger. Small vials present somedifficulty for oxygen analysis because the sample volume available is often quite small. A one ml vial, for example, may have only 0.5 ml of headspace gas. For direct analysis with a pharmaceutical oxygen analyzer, the instrument must be capable ofanalyzing very small volumes. Our pharmaceutical oxygen analyzer is designed for this process.
The GasCheck G gas leak detector represents the latest in gas detection technology. Its advanced system of micro thermal conductivity enables improved sensitivity for the rapid, effective detection of gas leaks down to cc/sec, mg/m or ppm levels.
Designed for the search and location of gas leaks, the GasCheck G leak detector provides you with effective detection of almost any gas or gas mixture. Robust and reliable, the GasCheck G leak detector gives stable, repeatable readings of the detected gas. The instruments LCD display, LED indicator and audible sounder clearly indicate the leak present.
The GasCheck G leak detector automatically zeros to the ambient air around it when switched on and is ready to detect immediately. The instruments easy to use graphical interface and intuitive keypad allows for simple function, selection and adjustment.
Upgradeable throughout the range, the GasCheck G gas leak detector is available in three distinct versions; G1, G2 and G3 with varied capabilities. Features can be easily added to upgrade the instrument without it having to be returned to the factory.
Probes for Relative HumidityFilter carriers protect the humidity and temperature sensors against mechanical damage. Filters act as a protective barrier against contaminants/pollutants that can infl uence the sensor. When choosing the correct combination of fi lter carrier and fi lter there are many factors to consider. Specifi c conditions such as high air velocities, pollutants in the air, disinfection and cleaning measures, mechanical impacts, high bioactivity, condensation, airborne chemical contaminants and required response time are some of the many considerations.
Plastic filter carrierMaximum temperature 120 CMechanical protection
Metal filter carrierMaximum temperature 200 CMechanical protection
Autonomous wireless data loggers:
Radio frequency:
High storage capacity:
Data security:
LAN interface:
Network connection:
USB wireless adapter:
Radio frequency: