Post Buy Requirement
Sudharsan Insulations
Chennai, Tamil Nadu, India
Verified Add Review

Our Products

  1. High Voltage Testers 4 Products available
  2. Test Kits 7 Products available
  3. Testing Equipment 5 Products available
  4. Transformers 3 Products available
  5. Relay Parts 12 Products available
  6. Power Supply System 4 Products available
  7. Others 12 Products available

Relay Parts #349634

C-50 Secondary Injection Over Current Relay Test Kit

  • Min. Order (MOQ) 1 Piece
  • Brand Name Sudharsan Insulation
  • Country of Origin India
  • Channels 2
  • Material MS
  • Model SI / C – 100 & SI / C – 50
  • Input 220V, 50Hz, 1Ph

Features

Features and performance similar to the types SI / CV- 50 and CV – 100, except that there is no provision of Auxiliary AC / DC outputs.

 

Dimensions

  • 425 x 390 x 280 mm, Wt. 28 Kg for SI / C-50
  • 495 x 450 x 300 mm, Wt. 35 Kg for SI / C-100

 

Specification

  • Type SI / C – 100 : AC Injection Current - Isolated from mains ( 60 sec rating), continuously adjustable from 0.01 to 100A on 3VA burden relay
  • Type SI / C – 50 : AC Injection Current - Isolated from mains ( 60 sec rating), continuously adjustable from 0.01 to 50A on 3VA burden relay.
View Complete Details

CV-30 Secondary Injection Over Current Relay Test Kit

  • Min. Order (MOQ) 1 Piece
  • Brand Name Sudharsan Insulation
  • Country of Origin India
  • Material MS
  • Dimensions 610 x 420 x 185 mm
  • Weight 25 Kg
  • Input 230V, 50Hz
  • AC Injection Current 0.01 - 30 Amps ( 60 Secs)
  • Aux. AC / DC Output 0 – 250v AC, 2A , 0 – 300v DC, 2A
  • Model Type SI / CV - 30 (Brief Case model)

Features

  • Assembled in VIP brief case.
  • Undistorted Sine wave Injection current.
  • Selection of either Current Injection or Auxiliary AC / DC output .
  • Digital ammeter and timer but no provision of AC / DC Voltmeter, which is to be measured externally.
View Complete Details

CV-10 Secondary Injection Over Current Relay Test Kit

  • Min. Order (MOQ) 1 Piece
  • Brand Name Sudharsan Insulation
  • Country of Origin India
  • Material MS
  • Dimensions 470 x 365 x 170 mm, Approx
  • Weight 12.5Kg
  • Model Type SI / CV - 10 (Brief Case model)
  • Input 230V, 50Hz
  • AC Injection Current 0.01 - 10 Amps ( 60 Secs)
  • Aux. AC / DC Output 0 – 250v AC, 0.75A, 0 – 300v DC, 0.5A

Features

  • Assembled in VIP/Aristocrat make moulded brief case.
  • Sine wave Injection current.
  • Selection of either Current Injection or Auxiliary AC / DC output .
  • Digital ammeter and timer but no provision of AC / DC Voltmeter, which is to be measured externally.
View Complete Details

SI/MCCB -1000-2000 MCCB Test Kit

  • Min. Order (MOQ) 1 Piece
  • Brand Name Sudharsan Insulations
  • Country of Origin India
  • Weight 52Kg
  • Model SI / MCCB - 1000/2000
  • Material MS
  • Dimensions 500 x 440 x 380 mm
  • Input 230V, 50Hz

Feature

Variant of Primary Injection kit SI / PIK but with provision for 4 digit auto ranging digital time interval meter.

 

Output

  • 3V / 1000Amp or as specified (1 min. rating) For SI / MCCB – 1000
  • 3V / 2000Amp or as specified (1 min. rating) For SI / MCCB - 2000
View Complete Details

SI-RCCB ELCB/RCD/RCCB Test Kit

  • Min. Order (MOQ) 1 Piece
  • Brand Name Sudharsan Insulations
  • Country of Origin India
  • Weight 7 Kg Apx
  • Model SI / RCCB
  • Dimensions 230 x 315 x 95 mm
  • Material MS
  • Input 230V, 50Hz
  • Output Mode 1 10 – 60mA for Domestic range
  • Output Mode 2 100 – 500mA for Industrial range

Features

  • Ideal for both Domestic and Industrial types.
  • Not suitable for DC systems and unearthed networks
  • mA Current Display with DPM – modules.
  • Range selection for 10 – 60mA / 100 – 500mA residual current.
  • Inexpensive, light weight, handy

 

Application

  • Testing of ELCB / RCD / RCCB
  • ELCB – Earth Leakage Circuit Breaker.
  • RCD - Residual Current Device.
  • RCCB – Residual current circuit breaker.
View Complete Details

2 In 1 SI/MCCB -1000-2000 MCCB Test Kit

  • Min. Order (MOQ) 1 Piece
  • Brand Name Sudharsan Insulations
  • Country of Origin India
  • Weight 52 Kg
  • Material MS
  • Model SI / MCB-MCCB 100 / 1000 / 2000 - (2 in 1)
  • Dimensions 500 x440 x 380 mm
  • Input 230V , 50Hz Single phase

Features

  • Mains Isolated single phase AC Injection Currents.
  • 2 in one test kit to test miniature circuit breaker (MCB) / Bimetal O/L relays up to 63A as well as molded case circuit breakers (MCCB) of upto 500 Amps.
  • Mode selector switch for MCB or MCCB testing.
  • Auto ranging digital Time Interval meter.
  • Compatible for NO / NC auxiliary trip contact selection.

 

Application

On- Line Production / Field or site testing of

  • Miniature Circuit breakers (MCB).
  • Bimetal Overload relays.
  • Moulded case circuit breakers (MCCB).

 

Output

Mode 1 : 0.01 to 100 Amp AC for MCBs

Mode 2

  • 100 to 1000 Amp AC for MCCBs
  • 100 to 2000 Amp AC for MCCBs
View Complete Details

MCB Bimetal Overload Relays Test Kit

  • Brand Name Sudharsan Insulations
  • Country of Origin India
  • Weight 33 Kg
  • Model SI / MCB – 100 & SI / MCB – 200
  • Dimensions 320 x 250 x 135 mm
  • Input 230V, 50Hz

Features

  • Mains isolated, distortion less sine wave AC injection current
  • Light weight and easily portable for “ ON – site” testing.
  • Compatible for NO / NC auxiliary trip contact selection.
  • Front panel equipment protected against mechanical damage with lockable cover.
  • 4 digit auto ranging Time Interval meter.

 

Output

Mains isolated A.C. Injection current continuously adjustable

  • From 0.01 Amp to 100 Amps . for SI / MCB - 100 ( 3 minutes rating)
  • From 0.01 Amps to 200Amps . for SI / MCB - 200 ( 3 minutes rating)
View Complete Details

PIK-5 Primary Injection Test Kit

  • Min. Order (MOQ) 1 Piece
  • Brand Name Sudharsan Insulations
  • Country of Origin India
  • Frequency 50
  • Model 5 & SI / PIK - 10 , (SI / PIK - 10T with extra timer)
  • Applications CT ratio testing, Primary injection relay testing
  • Input 220V to 240V, 50Hz , 1Ph

Features

  • Self contained fully integrated unit comprising MCB, Variac, Isolated wound Secondary Injection Transformer, Dual ratio C.T., and Digital Ammeter.
  • Input with 3 pin metal clad plug and socket.
  • Copper Bus bar output.
  • Push button operated Contactor with optional timer
  • Powder coated ms enclosure with front panel protection by a lockable cover.
  • Transportable on castor wheels.

 

Dimensions

  • 450 x 420 x 345 mm, Wt: 32 Kg. For 5 kVA unit
  • 580 x 590 x 420 mm, Wt: 66 Kg. For 10kVA unit

 

Output

  • 0 – 5V / 1000A ( 60 sec. Rating)
  • for 5 KVA unit – SI / PIK - 5
  • 0 – 5V / 2000A ( 60 sec. Rating)
  • for 10 KVA unit – SI / PIK -10
View Complete Details

PIK-20 Primary Injection Test Kit

  • Min. Order (MOQ) 1 Piece
  • Brand Name Sudharsan Insulations
  • Country of Origin India
  • Capacity 2000A
  • Frequency 50
  • Dimensions 720mm X 625mm X 690mm
  • Weight 96kg
  • Input 220V or 440Volts 50Hz
  • Model SI / PIK – 20 & SI / PIK - 15 (SI / PIK-15T with extra timer)

Features

  • Self contained fully integrated unit comprising MCB, Variac, Isolated wound Secondary Injection Transformer, Dual ratio C.T., and Digital Ammeter.
  • Input with 3 pin metal clad plug and socket.
  • Copper Bus bar output.
  • Push button operated contactor with optional timer Powder coated ms enclosure with front panel protection by a lockable cover.
  • Transportable on castor wheels.

 

Output

  • 0 - 5V / 2500A ( 60 sec. Rating) ( SI/ PIK 15)
  • 0 - 4V / 3000A ( 60 sec. Rating) ( SI/PIK 20)
View Complete Details

With Timer ELCB/RCD/RCCB Test Kit

  • Min. Order (MOQ) 1 Piece
  • Brand Name Sudharsan Insulations
  • Country of Origin India
  • Weight 10 Kg Apx
  • Model SI / RCCB – T (With Timer)
  • Dimensions 230 x 315 x 95 mm,
  • Input 230V, 50Hz
  • Output Mode 1 10 – 60mA for Domestic range
  • Output Mode 2 100 – 500mA for Industrial range

Features

  • Unit packed inside a VIP/Aristocrat suitcase.
  • mA Current LCD/LED display with DPM module.
  • 4 digit electronic timer with LED display to record trip time.
  • Ideal for both Domestic and Industrial types.
  • Not suitable for DC systems and unearthed networks.
  • Range selection for 10 – 60mA / 100 – 500mA residual current.
  • Inexpensive, light weight, handy.

 

Application

  • Testing of ELCB / RCD / RCCB
  • ELCB – Earth Leakage Circuit Breaker.
  • RCD - Residual Current Device.
  • RCCB – Residual current circuit breaker
View Complete Details

CV-200 Secondary Injection Over Current Relay Test Kit

  • Min. Order (MOQ) 1 Piece
  • Brand Name Sudharsan Insulation
  • Type Secondary Injection Relay Test Kit
  • Country of Origin India
  • Material MS
  • Model Number Type SI/CV - 200
  • Dimensions 530 x 510 x 570 mm, approx
  • Weight 59 Kg
  • Applications Secondary Injection Testing of StaticOver current/ Earth fault relays/ Electromagnet (CDG) relays
  • Input 220 – 240 V, 50Hz, 20 Amps
  • AC Injection current Isolated from Mains (60 Secs. Rating) Continuously adjustable from 0.01 – 200 Amps
  • Auxiliary Ac & Dc supply 0- 250 Volts, 0.5 Amps with only Dc Volt meter

Features

  • Undistorted Sine wave Injection Current.
  • Performance comparable to Alstom’s CFB Test kit.
  • Simultaneous availability of AC Injection Current and auxiliary AC / DC outputs.
  • Digital Panel meters for Volt / Amp / Timer.
  • Suitable for both NO / NC trip contacts of Relays under test.
  • Input overload protection with MCB for Current Injection and 0.5A glass fuse for Auxiliary AC/DC outputs.
  • Powder coated ms enclosure, portable with lifting handles and front panel protectionwith a lockable hinged cover.

 

Note : As the combined Ac & Dc voltmeter is not available, any one voltmeter ie. Either Ac or Dc voltmeter will be fitted to the test kit.

View Complete Details

CV-100 Secondary Injection Over Current Relay Test Kit

  • Min. Order (MOQ) 1 Piece
  • Brand Name Sudharsan Insulation
  • Country of Origin India
  • Material MS
  • Frequency 50
  • Model Number SI / CV – 50 & SI / CV – 100
  • Input: 220V, 50Hz, 1Ph
  • Applications Secondary Injection Testing of Static-Over current/Earth fault relays/Electromagnet (CDG) relays

Features

Undistorted Sine wave Injection Current.

  • Performance comparable to Alstom.s CFB Test kit.
  • Simultaneous availability of AC Injection Current and auxiliary AC / DC outputs.
  • Digital Panel meters for Volt / Amp / Timer.
  • Suitable for both NO / NC trip contacts of Relays under test.
  • Input overload protection with MCB for Current Injection and 0.5A glass fuse for Auxiliary AC/DC outputs.
  • Powder coated ms enclosure, portable with lifting handles and front panel protection with a lockable hinged cover.

 

Dimensions

  • 425x390x280mm, Wt 28Kg for CV- 50
  • 560x450x300mm, Wt 42Kg for CV- 100

 

Specification

Type SI / CV – 100

AC Injection Current - Isolated from mains (60 sec rating), continuously adjustable from 0.01 to 100A on 3VA burden relay.

Auxiliary output - continuously rated, non isolated from mains

  • 0 – 250V, 0.75 A AC
  • 0–300V, 0.5A DC

 

Type SI / CV – 50

AC Injection Current - Isolated from mains ( 60 sec rating), continuously adjustable from 0.01 to 50A on 3VA burden relay.

Auxiliary Output –continuously rated, non isolated from mains

  • 0 – 250V, 0.75 A AC
  • 0–300V, 0.5A DC
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • Mr. S. P. Rajah (Sudharsan Insulations)
  • 91-92, Developed Industrial Estate, Perungudi, Chennai, Tamil Nadu - 600096
  • https://www.sudharsaninsulations.in
  • Share us via
  • Call 08068051313 Ext. 064
Manufacturer of Relay Parts from Chennai, Tamil Nadu by Sudharsan Insulations
Post Buy Requirement
Sudharsan Insulations

Sudharsan Insulations

Verified Add Review

Our Products

  1. Relay Parts 12 Products available
  2. Test Kits 7 Products available
  3. Testing Equipment 5 Products available
  4. Power Supply System 4 Products available
  5. High Voltage Testers 4 Products available
  6. Transformers 3 Products available
  7. Auto Transformer

    2 Products available
  8. Digital Analyzers

    1 Products available
  9. Voltage Transformers

    1 Products available
  10. Test Bench

    1 Products available
  11. Others Products 7 Products available

Relay Parts

We are leaders in the market for providing best range of C-50 Secondary Injection Over Current Relay Test Kit, CV-30 Secondary Injection Over Current Relay Test Kit, CV-10 Secondary Injection Over Current Relay Test Kit, SI/MCCB -1000-2000 MCCB Test Kit and SI-RCCB ELCB/RCD/RCCB Test Kit

C-50 Secondary Injection Over Current Relay Test Kit

  • Min. Order (MOQ) 1 Piece
  • Brand Name Sudharsan Insulation
  • Country of Origin India
  • Channels 2
  • Material MS
  • Model SI / C – 100 & SI / C – 50
  • Input 220V, 50Hz, 1Ph

Features

Features and performance similar to the types SI / CV- 50 and CV – 100, except that there is no provision of Auxiliary AC / DC outputs.

 

Dimensions

  • 425 x 390 x 280 mm, Wt. 28 Kg for SI / C-50
  • 495 x 450 x 300 mm, Wt. 35 Kg for SI / C-100

 

Specification

  • Type SI / C – 100 : AC Injection Current - Isolated from mains ( 60 sec rating), continuously adjustable from 0.01 to 100A on 3VA burden relay
  • Type SI / C – 50 : AC Injection Current - Isolated from mains ( 60 sec rating), continuously adjustable from 0.01 to 50A on 3VA burden relay.
View Complete Details

CV-30 Secondary Injection Over Current Relay Test Kit

  • Min. Order (MOQ) 1 Piece
  • Brand Name Sudharsan Insulation
  • Country of Origin India
  • Material MS
  • Dimensions 610 x 420 x 185 mm
  • Weight 25 Kg
  • Input 230V, 50Hz
  • AC Injection Current 0.01 - 30 Amps ( 60 Secs)
  • Aux. AC / DC Output 0 – 250v AC, 2A , 0 – 300v DC, 2A
  • Model Type SI / CV - 30 (Brief Case model)

Features

  • Assembled in VIP brief case.
  • Undistorted Sine wave Injection current.
  • Selection of either Current Injection or Auxiliary AC / DC output .
  • Digital ammeter and timer but no provision of AC / DC Voltmeter, which is to be measured externally.
View Complete Details

CV-10 Secondary Injection Over Current Relay Test Kit

  • Min. Order (MOQ) 1 Piece
  • Brand Name Sudharsan Insulation
  • Country of Origin India
  • Material MS
  • Dimensions 470 x 365 x 170 mm, Approx
  • Weight 12.5Kg
  • Model Type SI / CV - 10 (Brief Case model)
  • Input 230V, 50Hz
  • AC Injection Current 0.01 - 10 Amps ( 60 Secs)
  • Aux. AC / DC Output 0 – 250v AC, 0.75A, 0 – 300v DC, 0.5A

Features

  • Assembled in VIP/Aristocrat make moulded brief case.
  • Sine wave Injection current.
  • Selection of either Current Injection or Auxiliary AC / DC output .
  • Digital ammeter and timer but no provision of AC / DC Voltmeter, which is to be measured externally.
View Complete Details

SI/MCCB -1000-2000 MCCB Test Kit

  • Min. Order (MOQ) 1 Piece
  • Brand Name Sudharsan Insulations
  • Country of Origin India
  • Weight 52Kg
  • Model SI / MCCB - 1000/2000
  • Material MS
  • Dimensions 500 x 440 x 380 mm
  • Input 230V, 50Hz

Feature

Variant of Primary Injection kit SI / PIK but with provision for 4 digit auto ranging digital time interval meter.

 

Output

  • 3V / 1000Amp or as specified (1 min. rating) For SI / MCCB – 1000
  • 3V / 2000Amp or as specified (1 min. rating) For SI / MCCB - 2000
View Complete Details

SI-RCCB ELCB/RCD/RCCB Test Kit

  • Min. Order (MOQ) 1 Piece
  • Brand Name Sudharsan Insulations
  • Country of Origin India
  • Weight 7 Kg Apx
  • Model SI / RCCB
  • Dimensions 230 x 315 x 95 mm
  • Material MS
  • Input 230V, 50Hz
  • Output Mode 1 10 – 60mA for Domestic range
  • Output Mode 2 100 – 500mA for Industrial range

Features

  • Ideal for both Domestic and Industrial types.
  • Not suitable for DC systems and unearthed networks
  • mA Current Display with DPM – modules.
  • Range selection for 10 – 60mA / 100 – 500mA residual current.
  • Inexpensive, light weight, handy

 

Application

  • Testing of ELCB / RCD / RCCB
  • ELCB – Earth Leakage Circuit Breaker.
  • RCD - Residual Current Device.
  • RCCB – Residual current circuit breaker.
View Complete Details

2 In 1 SI/MCCB -1000-2000 MCCB Test Kit

  • Min. Order (MOQ) 1 Piece
  • Brand Name Sudharsan Insulations
  • Country of Origin India
  • Weight 52 Kg
  • Material MS
  • Model SI / MCB-MCCB 100 / 1000 / 2000 - (2 in 1)
  • Dimensions 500 x440 x 380 mm
  • Input 230V , 50Hz Single phase

Features

  • Mains Isolated single phase AC Injection Currents.
  • 2 in one test kit to test miniature circuit breaker (MCB) / Bimetal O/L relays up to 63A as well as molded case circuit breakers (MCCB) of upto 500 Amps.
  • Mode selector switch for MCB or MCCB testing.
  • Auto ranging digital Time Interval meter.
  • Compatible for NO / NC auxiliary trip contact selection.

 

Application

On- Line Production / Field or site testing of

  • Miniature Circuit breakers (MCB).
  • Bimetal Overload relays.
  • Moulded case circuit breakers (MCCB).

 

Output

Mode 1 : 0.01 to 100 Amp AC for MCBs

Mode 2

  • 100 to 1000 Amp AC for MCCBs
  • 100 to 2000 Amp AC for MCCBs
View Complete Details

MCB Bimetal Overload Relays Test Kit

  • Brand Name Sudharsan Insulations
  • Country of Origin India
  • Weight 33 Kg
  • Model SI / MCB – 100 & SI / MCB – 200
  • Dimensions 320 x 250 x 135 mm
  • Input 230V, 50Hz

Features

  • Mains isolated, distortion less sine wave AC injection current
  • Light weight and easily portable for “ ON – site” testing.
  • Compatible for NO / NC auxiliary trip contact selection.
  • Front panel equipment protected against mechanical damage with lockable cover.
  • 4 digit auto ranging Time Interval meter.

 

Output

Mains isolated A.C. Injection current continuously adjustable

  • From 0.01 Amp to 100 Amps . for SI / MCB - 100 ( 3 minutes rating)
  • From 0.01 Amps to 200Amps . for SI / MCB - 200 ( 3 minutes rating)
View Complete Details

PIK-5 Primary Injection Test Kit

  • Min. Order (MOQ) 1 Piece
  • Brand Name Sudharsan Insulations
  • Country of Origin India
  • Frequency 50
  • Model 5 & SI / PIK - 10 , (SI / PIK - 10T with extra timer)
  • Applications CT ratio testing, Primary injection relay testing
  • Input 220V to 240V, 50Hz , 1Ph

Features

  • Self contained fully integrated unit comprising MCB, Variac, Isolated wound Secondary Injection Transformer, Dual ratio C.T., and Digital Ammeter.
  • Input with 3 pin metal clad plug and socket.
  • Copper Bus bar output.
  • Push button operated Contactor with optional timer
  • Powder coated ms enclosure with front panel protection by a lockable cover.
  • Transportable on castor wheels.

 

Dimensions

  • 450 x 420 x 345 mm, Wt: 32 Kg. For 5 kVA unit
  • 580 x 590 x 420 mm, Wt: 66 Kg. For 10kVA unit

 

Output

  • 0 – 5V / 1000A ( 60 sec. Rating)
  • for 5 KVA unit – SI / PIK - 5
  • 0 – 5V / 2000A ( 60 sec. Rating)
  • for 10 KVA unit – SI / PIK -10
View Complete Details

PIK-20 Primary Injection Test Kit

  • Min. Order (MOQ) 1 Piece
  • Brand Name Sudharsan Insulations
  • Country of Origin India
  • Capacity 2000A
  • Frequency 50
  • Dimensions 720mm X 625mm X 690mm
  • Weight 96kg
  • Input 220V or 440Volts 50Hz
  • Model SI / PIK – 20 & SI / PIK - 15 (SI / PIK-15T with extra timer)

Features

  • Self contained fully integrated unit comprising MCB, Variac, Isolated wound Secondary Injection Transformer, Dual ratio C.T., and Digital Ammeter.
  • Input with 3 pin metal clad plug and socket.
  • Copper Bus bar output.
  • Push button operated contactor with optional timer Powder coated ms enclosure with front panel protection by a lockable cover.
  • Transportable on castor wheels.

 

Output

  • 0 - 5V / 2500A ( 60 sec. Rating) ( SI/ PIK 15)
  • 0 - 4V / 3000A ( 60 sec. Rating) ( SI/PIK 20)
View Complete Details

With Timer ELCB/RCD/RCCB Test Kit

  • Min. Order (MOQ) 1 Piece
  • Brand Name Sudharsan Insulations
  • Country of Origin India
  • Weight 10 Kg Apx
  • Model SI / RCCB – T (With Timer)
  • Dimensions 230 x 315 x 95 mm,
  • Input 230V, 50Hz
  • Output Mode 1 10 – 60mA for Domestic range
  • Output Mode 2 100 – 500mA for Industrial range

Features

  • Unit packed inside a VIP/Aristocrat suitcase.
  • mA Current LCD/LED display with DPM module.
  • 4 digit electronic timer with LED display to record trip time.
  • Ideal for both Domestic and Industrial types.
  • Not suitable for DC systems and unearthed networks.
  • Range selection for 10 – 60mA / 100 – 500mA residual current.
  • Inexpensive, light weight, handy.

 

Application

  • Testing of ELCB / RCD / RCCB
  • ELCB – Earth Leakage Circuit Breaker.
  • RCD - Residual Current Device.
  • RCCB – Residual current circuit breaker
View Complete Details

CV-200 Secondary Injection Over Current Relay Test Kit

  • Min. Order (MOQ) 1 Piece
  • Brand Name Sudharsan Insulation
  • Type Secondary Injection Relay Test Kit
  • Country of Origin India
  • Material MS
  • Model Number Type SI/CV - 200
  • Dimensions 530 x 510 x 570 mm, approx
  • Weight 59 Kg
  • Applications Secondary Injection Testing of StaticOver current/ Earth fault relays/ Electromagnet (CDG) relays
  • Input 220 – 240 V, 50Hz, 20 Amps
  • AC Injection current Isolated from Mains (60 Secs. Rating) Continuously adjustable from 0.01 – 200 Amps
  • Auxiliary Ac & Dc supply 0- 250 Volts, 0.5 Amps with only Dc Volt meter

Features

  • Undistorted Sine wave Injection Current.
  • Performance comparable to Alstom’s CFB Test kit.
  • Simultaneous availability of AC Injection Current and auxiliary AC / DC outputs.
  • Digital Panel meters for Volt / Amp / Timer.
  • Suitable for both NO / NC trip contacts of Relays under test.
  • Input overload protection with MCB for Current Injection and 0.5A glass fuse for Auxiliary AC/DC outputs.
  • Powder coated ms enclosure, portable with lifting handles and front panel protectionwith a lockable hinged cover.

 

Note : As the combined Ac & Dc voltmeter is not available, any one voltmeter ie. Either Ac or Dc voltmeter will be fitted to the test kit.

View Complete Details

CV-100 Secondary Injection Over Current Relay Test Kit

  • Min. Order (MOQ) 1 Piece
  • Brand Name Sudharsan Insulation
  • Country of Origin India
  • Material MS
  • Frequency 50
  • Model Number SI / CV – 50 & SI / CV – 100
  • Input: 220V, 50Hz, 1Ph
  • Applications Secondary Injection Testing of Static-Over current/Earth fault relays/Electromagnet (CDG) relays

Features

Undistorted Sine wave Injection Current.

  • Performance comparable to Alstom.s CFB Test kit.
  • Simultaneous availability of AC Injection Current and auxiliary AC / DC outputs.
  • Digital Panel meters for Volt / Amp / Timer.
  • Suitable for both NO / NC trip contacts of Relays under test.
  • Input overload protection with MCB for Current Injection and 0.5A glass fuse for Auxiliary AC/DC outputs.
  • Powder coated ms enclosure, portable with lifting handles and front panel protection with a lockable hinged cover.

 

Dimensions

  • 425x390x280mm, Wt 28Kg for CV- 50
  • 560x450x300mm, Wt 42Kg for CV- 100

 

Specification

Type SI / CV – 100

AC Injection Current - Isolated from mains (60 sec rating), continuously adjustable from 0.01 to 100A on 3VA burden relay.

Auxiliary output - continuously rated, non isolated from mains

  • 0 – 250V, 0.75 A AC
  • 0–300V, 0.5A DC

 

Type SI / CV – 50

AC Injection Current - Isolated from mains ( 60 sec rating), continuously adjustable from 0.01 to 50A on 3VA burden relay.

Auxiliary Output –continuously rated, non isolated from mains

  • 0 – 250V, 0.75 A AC
  • 0–300V, 0.5A DC
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us