Three Phase Transformer

  • Ratio 440/200V
  • Rating: 15KVA
  • Insulation Level 0.66/2.5KV
  • Primary Tapping +2.5, +5%
  • Transformer Class ‘B’/’F’
  • App. Std. 11171/1985.
  • Construction Indoor, Varnish Impregnated dry type/Cast Resin in open execution.

Three phase transformers are designed to supply electric power to three-phase systems. These electrical devices have three circuit conductors and may or may not have a neutral wire. Three phase power is used by electric power distribution grids and to power large motors and other large loads. Three phase transformers carry many product specifications, including transformer type, winding turns, cooling method, core type, and mounting style. Performance specifications, regulatory approvals, and special features are also important parameters to consider. Performance specifications include operating frequency range, maximum primary voltage rating, maximum secondary voltage rating, maximum secondary current rating, power rating and operating temperature. Configuration styles for three phase transformers consist o f delta delta, delta wye (Y), wye (Y) wye (Y), wye (Y) delta, wye (Y) single phase, delta single phase.

View Complete Details

Single Phase Transformer

  • Ratio 415/230V
  • Rating 5KVA
  • Insulation Level 0.66/2.5KV
  • Primary Tapping +2.5, +5%
  • Transformer Class ‘B’/’F’
  • App. Std. 11171/1985
  • Construction Indoor, Varnish Impregnated dry type/Cast Resin in open execution

Single phase transformers may be used to increase or decrease the voltage from one side of the transformer to the other. The turn ratio or number of windings on the primary and secondary sides of the device determines the change in voltage. Step-up transformers produce a secondary voltage that is larger than the primary voltage. Step-down transformers have a secondary voltage that is smaller than the primary voltage. Variable single phase transformers are devices with a setting for changing the turn ratio as needed. One-to-one transformers well known as Isolation Transformer are single phase transformers with a turn ratio of 1:1.

View Complete Details

High Voltage Tester

49,000 - 50,000 /Piece Get Latest Price
  • Open Circuit Voltage 0to5KVOR0to 10 KVAC. The above voltage can be continuously varied from zero to full value and is continuously monitored by Analog/Digital Panel meter.
  • Test Current 2 mA to 20 mA OR 3 mA to 100 mA
  • Accuracy of Reading Power ±2%
  • Requirements Safety 230 volts AC, ± 10%, 50/60 Hz
  • Precautions Voltage on test terminals. High Voltage on test jig appears only after the variac is set to zero and gradually increased. There is a trip device to trip if the current increases than the required value
  • Trip settings The tripping can be reset by a pot which can be varied as peruse requirement
  • Open Circuit Voltage 0 to 30 KV OR 0 to 100 KV AC. The above voltage can be continuously varied from zero to full value and is continuously monitored by Analog/Digital Panel meter.
  • Test Current 5 mAto 50 mA OR 10 mAto 100 mA
  • Accuracy Of Reading ±2%
  • Power Requirements 230 volts AC, ± 10%, 50/60 Hz
  • Open Circuit Voltage 0 to 5 KV or 0 to 10 KVAC. The above voltage can be continuously varied from zero to full value and is continuously monitored by Analog/Digital Panel meter.
  •   Protection provided with zero start to prevent accident availability of High