Post Buy Requirement
SC

Standard Control Panel Pvt. Ltd.

Add Review

Other Products / Services

We offer the best product range of Apfc Relay.

Load Sharing Panel

  • Rated Service Voltage 690v
  • Rated Insulation 1000v
Applications-Power distribution through main & DG Supply, Type Tested for-Short Time Current withstand Temperature Rise Degree of Protection, Bus Bar System-Interleaved above 1600A, Ref. Standard-IEC61439-12009, IS:8623
View Complete Details

Auto Main Failure Panel

  • Applications Operation, Control & protection of distribution network with or without PLC/BMS Connectivity
  • System 3 Phase, 3 or 4 wire, 50Hz
  • Rated Current Upto 6300 Amps
  • Operational Voltage 110/230v 415v AC
  • Rated Insulation 1000v
  • Rated Service Voltage 690v
  • Ambient Temperature 45 Deg C
  • Short Time Current 50KA for 1Sec, 105KA peak
  • Degree of Protection IP42-IP54
  • Form of Sepration Upto 3B/4B (Optional Type 5)
  • Type Tested for Short Time Current withstand Temperature Rise Degree of Protection
  • Bus Bar System Interleaved above 1600A
  • Bus Bar Aluminium or Copper
  • Ref. Standard IEC61439-12009, IS:8623
  • Feeder Configuration Semi Drowout or Fix Type

Auto Main Failure Panels, also known as AMF panels, are used to automatically changeover from mains electricity supply to stand-by generator or gen set on failure of the mains supply. When the mains supply is restored, the system automatically changes back and stops the gen set. The stand-by generator will be eventually shut down after a short cooling down period.
We manufacture and supply AMF (Auto Mains Failure) Panel as per the specific requirements of the clients. These panels are used for controlling power supply in various industries like processing plants, hospitals etc. On the request of the clients, we customized these panels (both automatic and manual modes) to meet client-specific requirements.

View Complete Details

Auto Load Sharing Panel

  • Applications Power distribution through main & DG Supply
  • System 3 Phase, 3 or 4 wire, 50Hz
  • Rated Current Upto 6300 Amps
  • Operational Voltage 110/230v 415v AC
  • Rated Insulation 1000v
  • Rated Service Voltage 690v
  • Ambient Temperature 45 Deg C
  • Short Time Current 50KA for 1Sec, 105KA peak
  • Degree of Protection IP42-IP54
  • Form of Sepration Upto 3B/4B (Optional Type 5)
  • Type Tested for Short Time Current withstand Temperature Rise Degree of Protection
  • Bus Bar System Interleaved above 1600A
  • Bus Bar Aluminium or Copper
  • Ref. Standard IEC61439-12009, IS:8623
  • Feeder Configuration Semi Drowout or Fix Type
We are leading supplier of this product.
View Complete Details

Variable Frequency Drive

  • Applications Readymade as per customer specification for various type of industries, Indoor or outdoor metering, control, protection, relay & automation for LV panel PLC & RELAY Based
  • System 3 Phase, 3 or 4 wire, 50Hz
  • Rated Current Upto 4000 Amps
  • Operational Voltage 24/110/230v 415v AC
  • Rated Insulation 1000v
  • Rated Service Voltage 690v
  • Ambient Temperature 45 Deg C
  • Short Time Current 50KA for 1Sec, 105KA peak
  • Degree of Protection IP42-IP54
  • Form of Sepration Upto 3B/4B
  • Type Tested for Short Time Current withstand Temperature Rise Degree of Protection
  • Bus Bar System Interleaved above 1600A
  • Bus Bar Aluminium or Copper
  • Ref. Standard IEC61439-12009, IS:8623
  • Feeder Configuration Semi Drowout or Fix Type

A Variable Frequency Drive (VFD) is a type of motor controller that drives an electric motor by varying the frequency and voltage supplied to the electric motor. Other names for a VFD are variable speed drive, adjustable speed drive, adjustable frequency drive, AC drive, microdrive, and inverter. Sometimes your work space is dusty, dirty, wet, humid, corrosive, or hot. In those harsh environments, you cannot just mount your VFD exposed. You need a VFD Control panel an enclosure that protects the VFD and other electric components.

View Complete Details

Air Insulated Bus Duct

  • Type Totally enclosed, Air insulated, Non segregated
  • Applications Operation, Control & protection of distribution network with or without PLC/BMS Connectivity
  • System 3 Phase, 3 or 4 wire, 50Hz
  • Rated Current Upto 6300 Amps
  • Operational Voltage 415v AC
  • Rated Insulation 1000v
  • Rated Service Voltage 690v
  • Ambient Temperature 45 Deg C
  • Short Time Current 50KA for 1Sec, 105KA peak
  • Degree of Protection IP42 for indoor installation, IP55 for outdoor installation
  • Form of Sepration Upto 3B/4B (Optional Type 5)
  • Type Tested for Short Time Current withstand Temperature Rise Degree of Protection
  • Enclosure Epoxy Powder Cated CRCA Sheet
  • Neutral 50% / 100% (Optional)
  • Earthing Separate Earth bus provided on enclosure
  • Bus Bar Insulation Black PVC insulation with colour coding for phase identification black matt paint for bus bar rating 2500A and above
  • Ref. Standard IEC61439-12009, IS:8623

We offer highly efficient HT/LT Bus Duct and rising mains. This is offered with both indoor and outdoor construction with IP42/55 degree of protection. The type of bus duct is offered in aluminum and copper based and manufactured as per the International Standards. SCPPL designs bus duct systems in a way that it allows you to have multiple outputs from it without any power loss. Our manufactured Bus Bar Chambers needs very less maintenance.

View Complete Details

Electrical Distribution Box

  • System 3 Phase, 3 or 4 wire, 50Hz
  • Rated Current Upto 4000 Amps
  • Operational Voltage 110/230v 415v AC
Electrical distribution box is a panel or enclosure that houses the fuses, circuit breakers and ground leakage protection units where the electrical energy, which is used to distribute electrical power to numerous individual circuits or consumer points, is taken in from the transformer or an upstream panel. An MDB typically has a single or multiple incoming power sources and includes main circuit breakers and residual current or earth leakage protection devices.
View Complete Details

Power Distribution Box

A motor control center (MCC) is an assembly of one or more enclosed sections having a common power bus and principally containing motor control units. Motor control centers are in modern practice a factory assembly of several motor starters. A motor control center can include variable frequency drives, programmable controllers, and metering and may also be the electrical service entrance for the building. Motor control centers have been used by the automobile manufacturing industry which used large numbers of electric motors. Today they are used in many industrial and commercial applications. Where very dusty or corrosive processes are used, the motor control center may be installed in a separate air-conditioned room, but often an MCC will be on the factory floor adjacent to the machinery controlled.
View Complete Details

It Panel Board

An MDB is a panel or enclosure that houses the fuses, circuit breakers and ground leakage protection units where the electrical energy, which is used to distribute electrical power to numerous individual circuits or consumer points, is taken in from the transformer or an upstream panel. An MDB typically has a single or multiple incoming power sources and includes main circuit breakers and residual current or earth leakage protection devices.
View Complete Details

Apfc Relay

APFC or Automatic Power Factor Control Panels are mainly used for the improvement of Power Factor. Power Factor can be explained as ratio of active power to apparent power and it is a key factor in measuring electrical consumption. Everyone knows that how costly electricity has become in present time. Therefore it becomes utmost important to cut down on electrical consumption for reducing expenditure. APFC Panels come real handy in the achievement of this purpose Use of these control panels becomes indispensable in those industries where electrical installations are meant to supply to large electrical load.
View Complete Details

Control Panel Cabinet

  • System 3 Phase, 3 or 4 wire, 50Hz
  • Rated Current Upto 6300 Amps
  • Operational Voltage 110/230v 415v AC
Control panel cabinet is used for distribution and control of various power source used in industry. Normally Power Control Centers is installed near power source hence fault level is high. Busbar system in Power Control Centers are designed to suit the fault level as well as temperature rise to 40c above ambient. Ample space is provided for cable termination. Various protections viz short circuit, overload, earth fault, under voltage etc are provided to protect source and equipment.
View Complete Details