2 Products availableLeading Manufacturer, Supplier & Retailer of Ladder Flammability Tester, Sample Die for Limiting Oxygen Index, Flammability Test, High Current Tester and Halogen Acid Gas Emission Test Apparatus.
model number: ssi 514 ftlt
standard number: ieee 383
this method covers a laboratory procedure for testing of bunch cables mounted vertically to determine their relative ability to resist flame prorogation. The test is conducted in open air environment only. instrument principlethis method covers a laboratory procedure for testing of bunch cables mounted vertically to determine their relative ability to resist flame prorogation. The test should demonstrate that the bunched cable doesnt propagate fire even after its outer covering and insulation have been destroyed in the area of flame impingement. standard the instrument conforms to ieee 383. instrument the instrument consists of ladder as sample stand burner stand ribbon type burner control panel complete with manometers for lpg and air temperature indicator one meter long thermocouple rubber pipe for lpg connection. |
Model Number: SSI 515.1
Standard Number: ASTM D 2863IS 10810
Correct and accurate sample is necessary for result accuracy and repeatability. The Sample Die is designed to produce equal sized samples for testing Limiting oxygen Index Test Apparatus.
The Die is specifically designed to make samples for Limiting Oxygen Index Test Apparatus. The Die is manufactured in three pieces. The upper and lower plates are support plates. The Middle plate has cut out for the samples as per the standard requirement.
The Die with sample is kept in Hydraulic press for formation of smooth and accurate samples to be tested in for Limiting Oxygen Index.
The UL test serves as a preliminary indicationfor Plasticscomponents acceptability for use as part of a device or appliance with respect to its flammability.The instrument is designed for both Vertical and Horizontal burning.
Model Number: SSI 595
The instrument is designed to test the current capacity of any wire by passing very high current through it. A wire is attached to the instrument and current is passed through it. The current is then gradually increased. The current at which the wire starts to burn is then noted.
The instrument consists of
The instrument is supplied with NABL Lab calibration for Ampere Meter. |
model number: ssi 518 hag
standard number: iec 754 pt 1 & 2is 10810 pt 59
compounds based on halogenated polymers and compounds containing halogenated additives emits harmful halogen acid gas while burning. These gases are corrosive and can prove harmful to property and humans in case of fire. instrument principlecompounds based on halogenated polymers and compounds containing halogenated additives emits harmful halogen acid gas while burning. These gases are corrosive and can prove harmful to property and humans in case of fire. Is 18010 (pt. 59) & iec 754-1-94 test determine the amount of halogen gas other than hydrofluoric acid evolved during the combustion of cables and other similar compounds. standardthe instrument is manufactured as per the is specification and confirm to test app., method 754 2 fig 4. instrumentthe instrument comprising of tubular furnace for temp. Up to1000oc +- 10oc. |
Model Number: SSI 569 TC
Standard Number: IS 1554IS 649
The insulation material in a cable is used to isolate the conductor from one another and from ground, as well as provide the necessary mechanical strength. The fundamental requirement of the insulation in an electric cable is that it withstand the voltage imposed on it in the service. Description The insulation material in a cable is used to isolate the conductor from one another and from ground, as well as provide the necessary mechanical strength. The fundamental requirement of the insulation in an electric cable is that it withstand the voltage imposed on it in the service. It is necessary that a evaluation of the condition on the insulation be made by imposing a higher voltage stress for a short duration. The DC High Voltage tester provides ideal condition to test any cable for its capability to withstand high DC voltage The Instrument consist of (for each station) Dimmer to increase / decrease the DC HV HT DC output points 2 KV Voltmeter. (other voltages available on request) Tripping Circuit Cable connectors Water Bath (to be purchased separately) |
Model Number: SSI 516 OF
Smoke Density Apparatus is used for measuring & observing the relative amount (Density) of smoke produced by the heating / burning (combustion) or decomposition of Oil and oil based material etc. under controlled conditions. Instrument PrincipleSmoke Density Apparatus is used for measuring & observing the relative amount (Density) of smoke produced by the heating / burning (combustion) or decomposition of Oil and oil based material etc. under controlled conditions.
The sample is heated under controlled temperature , through a specified designed heating system. A light source and a photo receptor is placed on either side of the chamber, and the percentage of light Transmitted / absorbed is displayed through a linear amplifier digital electronic photometer with 0 to 100% scale. The apparatus comes complete with timer with 1.5-second pulse at every 15 sec with hold facility, temperature controller for heating block and Roto Meter to control the air flow. InstrumentThe instrument comprising of
Heating Block Saturation Chamber (including sample holding area) Condensation / Smoke Chamber Electronic Photometric System Timer Specimen Holder Digital Temperature Controllers Rotometers |
The ISO test serves as a preliminary indication of Textile / plastics material acceptability for use as part of a device or appliance with respect to its flammability.The test is conducted in a Five sided chamber without the roof top.
Model Number: SSI 527
Standard Number: IS 10810 Pt 18
The Test is designde to test the evpouration or fading of color when exposed to direct sunlight. The Test is designde to test the evpouration or fading of color when exposed to direct sunlight. The sample is exposed to direct sunlight and is kept for a certian period of time. After the completion of the test, the color of the sample is compared with standard Grey Scale to determin the fading of the color. |
Model Number: SSI 516 SDASH
Standard Number: ASTM 2843, IS 13660 (Part 6/Sec9)
Smoke Density Apparatus is used for measuring & observing the relative amount (Density) of smoke produced by the burning (combustion) or decomposition of Plastic, Cables etc. under controlled conditions.
Model Number: SSI 569
Standard Number: IS 649IS 1554
The insulation material in a cable is used to isolate the conductor from one another and from ground, as well as provide the necessary mechanical strength. The fundamental requirement of the insulation in an electric cable is that it withstand the voltage imposed on it in the service. The insulation material in a cable is used to isolate the conductor from one another and from ground, as well as provide the necessary mechanical strength. The fundamental requirement of the insulation in an electric cable is that it withstand the voltage imposed on it in the service. It is necessary that a evaluation of the condition on the insulation be made by imposing a higher voltage stress for a short duration. The DC High Voltage tester provides ideal condition to test any cable for its capability to withstand high DC voltage The Instrument consist of Dimmer to increase / decrease the DC HV HT DC output points 2 KV Voltmeter. (other voltages available on request) Tripping Circuit Cable connectors Water Bath (to be purchased separately) |