Our Products
Laboratory Apparatus
2 Products availablePackaging Seals And Caps
2 Products availableWater Softening System
1 Products availableHeat Exchangers
1 Products availableHeaters, Thermostats & Heating Devices
1 Products availableWool
1 Products availablePVC, PP & Plastic Products
1 Products availableFilters & Filtration Systems
1 Products availableQuartz Ore
1 Products availableOur product range contains a wide range of Distillation Units Borosilicate Glass, QUARTZ DOUBLE DISTILLATION and Double Distillation Unit
VITSIL glass distillation units continue to be the most effective, economic method of producing ultra pure water for laboratory use.
By contrast de-ioniser are only effective in removing those substances which are ionized. Further the resins contribute organic impurities to water and an ideal environment for bacterial growth in course of time.
These distillation units are designed to produce a distillate of consistent purity. The unit consists of horizontal borosilicate boilers, condensers and quartz heater. All parts are replaceable.
The newly developed quartz heater is advantageous than chromium plated heaters used by other manufacturers. Chromium plated heaters react with acids during cleaning process.
Quartz heaters do not react with acids or water during cleaning or at elevated temperature unlike metallic ones. Quartz heaters are easy to assemble and dismantle, unlike metallic ones which are bulky.
MODEL No. | VBSD 1.5L | VBSD 4.0 L |
---|---|---|
Dist. Water Output cap. (Approx) |
1.5 lt/hr. | 4 lt/hr |
Electrical requirements | 230-250 volts single phase 1.5 kw Quartz heater |
230-250 volts single phase 3 kw Quartz heater |
Cooling water consumption | 50 lt/hr. | 60 lt/hr. |
Biological Activity | Pyrogen Free |
Pyrogen Free |
pH | 6 - 7 | 6 - 7 |
Double Distillation
MODEL No. | VBDD 1.5L | VBDD 4.0 L |
Dist. Water Output cap. (Approx) | 1.5 lt/hr | 4 lt/hr |
Electrical requirements | 230-250 volts single phase2 x 1.5 kw Quartz heater |
230-250 volts single phase 2 x 3 kw Quartz heater |
Cooling water consumption | 100 lt/hr. | 150 lt/hr. |
Biological Activity | Pyrogen Free |
Pyrogen Free |
pH | 6.9 - 7 | 6.9 - 7 |
supply of pyrogen free distilled water is basic requisite for many research, analytical & industrial laboratories. Moreover, the materials of the distillation apparatus and storage vessels, should be chosen so as to avoid diffusion of contamination into the distillate.
Quartz distillation units are manufactured from imported fused quartz tubes. The exceptionally high chemical purity and very low solubility of this material enables the production of very high performance system. The greatest possible attention has been taken for technical performance, simplicity of use and efficiency.
DESCRIPTION OF APPARATUS
The unit consist of a primary boiler with built-in heater.
The primary boiler has a O ring groove at the top, on which a silicone O ring sits. The secondary boiler with condenser is mounted on the primary boiler.
A double wall condenser ensures separate condensation of vapor coming from the two boilers using a single cooling circuit.
The whole unit is mounted on powder coated stand with electrical terminals for easy connection either to the mains or DAPS (Distillation Apparatus Power Supply) The bottom outlet is connected to a T joint of which one limb is connected by a rubber tubing & pinch cock for cleaning sediments in primary boiler by acid wash and other limb to the water leveller of DAPS.
DEMOUNTABLE MODEL
In view of calcium & magnesium deposits occurring in primary boiler and the difficulty involved in cleaning these deposits, made us to think of designing the apparatus, so that the primary boiler could be easily dismantled for easy cleaning of calcium & magnesium deposits.
Spare bottom boilers are available normally from ready stocks.
NNOVATIVE DESIGN
The primary boiler is being provided with a O ring which acts as a cushion on which secondary boiler and condenser unit is mounted.
DEMERITS IN OTHER BRANDS OF DISTILLERS
The distillers available in the market provide either glass flange with clamps or glass ball and socket connection. Glass connections are liable for breakages. The calcium & magnesium deposit forms around the ball joint, thereby, freezing the unit. The steam leaking at ball joint is a very common feature in other brands.
Silicone rubber boot & fiber glass insulated electrical connections withstand higher temperature and long lasting as compared to rubber boot & PVC insulated wire provided by other manufacturers.
Model No. | VQDD 1L | VQDD 1.5L | VQDD 2.0L | VQDD 2.5L | VQDD 5L |
---|---|---|---|---|---|
Dist. Water Output cap. (approx) | 1 lt/hr. | 1.5 lt/hr. | 2 lt/hr. | 2.5 lt/hr. | 5 lt/hr. |
Electrical requirements | 230 -250 volts single phase 2 kw |
230 -250 volts single phase 3 kw |
230 -250 volts single phase 3.5 kw |
230 -250 volts single phase 4.4 kw |
440 volts 3 phase 8.8 kw |
Cooling water consumption | 50 lt/hr. | 60 lt/hr. | 65 lt/hr. | 100 lt/hr. | 150 lt/hr. |
Biological Activity | Pyrogen Free | Pyrogen Free | Pyrogen Free | Pyrogen Free | Pyrogen Free |
pH | 6.9 - 7 | 6.9 - 7 | 6.9 - 7 | 6.9 - 7 | 6.9 - 7 |