Our Product / Services
Automation System
2 Products availableMeasuring Instruments & Equipment
2 Products availableElectrical & Electronic Testing Devices
2 Products availableGenerators, Turbines & Power Plants
1 Products availableInstrumentation & Control Equipment
1 Products availableSecurity And Inspection Devices
1 Products availableGPS, Navigation & Tracking Devices
1 Products availableInverters
1 Products availableUPS
1 Products availableOur Complete range of products are Spectrum Analyzer Training System (S-5022), Spectrum Analyzer Training System (S-5022A), Microstrip Systems Trainer, Antenna Systems Trainer and Power Scope.
We are offering Spectrum Analyzer, Click Here For Details. .
Additional Information:
Payment Terms : T/T
We offer optimum quality variable Power Scope for measuring high and floating voltage in the power, electronics and electrical field. We have carved a niche as one of the dependable Variable Power Scope Manufacturers and Suppliers in Mumbai. Utilization of superlative raw materials and advance technology machines enhance their durability and reliability. This High Power Scope is free from adapter and provides excellent performance. Their long lasting trouble free performance, make them highly popular among various educational field. We deliver S-9 Power Scope at brisk pace and that too at very moderate price.
Additional Information:
Payment Terms : T/T
Delivery Time : 12-16 weeks
Our company is counted as one amongst the forefront Digital Frequency Counter Suppliers in India. Catering the requirements of the national as well as international clients, the company has acquired noteworthy position amidst the reliable Portable Frequency Counter Exporters. Additionally, we offer Frequency Counters that comply with the international standards in terms of quality, performance and output.
Additional Information:
Payment Terms : T/T
International Electronics - A brief history of Product Development and Introduction 1957 : 1957 Company established IE started with design and manufacture of Radio Sets, Radiograms, Hi-Fi Audio Systems, Public Address Systems for large halls (upto 10, 000 seating capacity). 1961 : Applied for Oscilloscope Manufacturing License 1966 : Received the Oscilloscope License 1966-68 : Type 10-12U 4.5 MHz Oscilloscope free running general purpose 1968-70 : Type IE-15 15MHz Oscilloscope with Calibrated Vertical & Timebase The scope was generally similar to Tektronix 516 and was INDIA's first scope using rectangular CRT with 6x10cms display. The first unit was sold to VJTI Bombay Type IE-16 was a Double Beam Oscilloscope, specially developed for Dr. Bhavalkar of BARC, MOD Labs - Laser division Time Mark Generator - Oscilloscope Calibration Equipment for CMT Bangalore 1972-75 : TV Tuner with Electronic Tuning developed first time in India Hybrid TV set with 3 IC's developed first time in India 1975-76 : 15MHz Oscilloscope operating at 10KV -20deg to +55 deg to JSS 55555 specs developed first time in India, 70 nos supplied to Defence Oscilloscope Calibrator developed for Defence Inspection 1977-80 : Constant Amplitude RF Source developed and BRAND manufactured for PHILIPS AM Signal Generator with Digital Readout developed and BRAND manufactured for PHILIPS on black box concept 1980-81 : IE-369 TV Sweep Generator - India's first Sweep Generator, used by 100's of Small Scale TV manufacturers and Educational Institutions. Introduced a series of Single & Dual Trace Oscilloscopes which were marketed thru MELTRON a Maharashtra State Government Organization. 1982 : IE-459 Sweep Generator System with Plug-ins for PHILIPS service centers. System is unique in that plug-ins covered Audio Sweep, AM/FM Radio Sweep, TV IF & RF Sweep - with Markers. 1982-85 : 20MHz Ultra portable Oscilloscopes - IE-45 & IE-405 Dual Trace Oscilloscopes were introduced which would fit in an office brief case IE-1044 and IE-1035 Colour TV pattern Generators, developed first time in India 1985-87 : IE-900A 110MHz AM/FM Signal Generator with Counter was introduced IE-234 30MHz Oscilloscope with built-in counter and delayed sweep was introduced 1987-89 : IE-504 20MHz STORAGE Oscilloscope, developed first time in India IE-9 20MHz PowerScope with differential floating input. IE-495W 240MHz Wobbuloscope (sweep generator) with Synthesized Markers, developed first time in India - supplied in 100's to World Bank funded Educational Institutions 1989-90 : IE-522 20MS/s DSO with direct Hardcopy via centronics interface & FFT Analysis and Waveform Processing Software on PC via RS232 interface - India's first and only indigenously developed DSO. IE-531 5MHz DSO with Digital X-Y Storage 1991 : IE-837W 860MHz Wobbuloscope with Synthesized Markers - India's first and only indigenously developed 860MHz Wobbuloscope. 1992 : IE-567 25MHz DigiTestLab (10 in 1) comprising of: Digital Scope 20MS/s - 25MHz Analog Scope - Frequency Counter - Function Generator - Curve Tracer - Component Tester - Continuity Tester - Triple Power Supply - Centronics - RS232 1993-95 : Introduced a range of Low Cost Synthesized Signal / Sweep Generators - India's first IE-945 260MHz AM / FM(Stereo) Synthesized Signal Generator IE-1125 150MHz AM / FM(Stereo) Synthesized Signal Generator IE-1134 110MHz Sweep Generator with Synthesized Markers IE-936 300MHz AM / FM(Stereo) Synthesized Signal Generator + Sweep Generator + Synthesized Markers (settable with 1KHz reso) IE-8100 1GHz Frequency Counter/Timer 1995 97 : IE-9144 Synthesized Color Pattern Generator CABLE READY (PAL / NTSC) with 106 CHs preprogrammed with key-pad frequency entry. Video & Audio Input/Output IE-9036 Digital Frequency Response Meter IE-8955 Noise Generator 860MHz Introduced a range Digital Signal Level Meters for CATV offering unique features. Auto Tuning, Auto Attenutaion, 0.1dB reso, 1.5dB typ accy, SPECTRUM printout via Centronics, RS232 and AC/DC voltage measurements. 1997-99 : IE-5013 Remote Spectrum Monitor via Telephone / Modem IE-5004 860MHz Spectrum Analyzer with Tracking Generator Network Analyzer (Scalar) IE-4050 Service Test Station (4 in 1) comprising of 110MHz AM/FM Synthesized Signal Generator, 1MHz Function Gen, 110MHz Frequency Counter, 30V 1A Power Supply InPower54 Power Meter Software for YOKOGAWA WT130 (consultants for hardware interface) Model 9A Antenna & EMI/EMC Systems Trainer 2000 +
InPower54 Power Meter Software has been configured for Yokogawa Power Meter WT110 & WT130. The Power Meter can be interfaced to the PC via RS232 or GPIB. Thru the software the user has full control over all the setup functions of the power meter. Real time data can be captured and displayed as LED readouts as well as graphical trends etc. Easy Setup of Parameters The user can select upto 14 parameters, such as V, I, V/A, pF etc alongwith the Element No. Parameter selection is one by one and can be added to the list on the right hand side. (14 parameters selection is the limitation of WT130 Power Meter) LED Readout of Parameters Each LED window displays the instantaneous value of the parameters selected above (upto 14). Each window depicts the type and unit of the parameter. The sequence of display is the same as the list of selection above. Files can be saved to disk. User has to select the time interval between saving and total duration for which the data has to be captured. The maximum duration is 30 days or 10, 000 points of data storage, which ever is earlier, data is stored along with the Date and Time Stamp. Trend of Each Parameter The data of each LED window above is displayed as a Trend Graph. Each of the Trend window is placed identically to the LED windows for easy co-relation. The Upper/Lower display value of each window is individually adjustable. Trend of any 4 Parameters The Trend windows above are very useful for an overview of upto 14 trends. For detailed study any 4 of the 14 Trends can be studied in detail. Recall Saved File and Cursor Measurements Files saved on disk can be recalled. Any of the parameters can be observed in the windows. Cursor measurements of each of the parameter are possible, along with the Date and Time at which the measurement was made. Zooming is possible between two cursors. Harmonics The Harmonics data is retrieved at the end of each computation cycle. V, I and W up to 50th harmonic is displayed in the 3 windows. User can set the Cursor to the desired Harmonic (0 to 50th) to measure the individual harmonic values of each parameter. Listing of all the Harmonics is also available. User can save the data to file as well as obtain a printout.
We are the prominent Manufacturer, Exporter and Supplier Medium Wind Turbine. We offer premium quality Medium Wind Turbine fabricated from high grade components using advance technology. Clients can avail Medium Wind Turbine from us at the affordable price. Features :