Post Buy Requirement
SIGMA INSTRUMENTS PVT.LTD
Vadodara, Gujarat, India
Add Review

Our Products #1630193

Gas Chromatograph

We are offering Gas Chromatograph. The latest in the series of the gcs. User friendly with minimum controls. The large double walled s.s. Oven means more space & easy changing of columns, option of detectors- tcd, fid, ecd, npd, fpd, etc. operation option of packed capillary column. Standard features include auto cooling, remote ignition, 15 temperature ramps to tackle any complex sample, storage of 15 methods for instant recall, temperature accuracy of + 0.1 deg c for oven, injector, detector. Operation from ambient to 4000 c for oven, injector & detector with control accuracy of + 0.1 deg c option of auto gas liquid sampling valves, protection against over temperature for oven, injector & detector and optional protection for operation against absence of carrier gas.
View Complete Details

Gas Chromatograph With Head Space

We are offering Gas Chromatograph with Head Space. Designed primarily for use with Sigma make Automated GC Model 606. It can be connected to any make GC with proper attachment. The features includes 6 vials of 20ml capacity, temperature controller having range from ambient to 200 Deg C with accuracy of + 0.1 Deg C to heat vial block, gas sampling valve, sample loop & samples transfer line. Sequences of Head space sampler like pressurizing, depressurizing samples injection & flushing are done through time event relay provided in GC.
View Complete Details

Column Conditioning Oven

This is a stand alone unit. Has high quality S.S. double walled construction using imported glass wool which provides stable temperature in oven. Permits conditioning of two columns at a time. The unit is provided with inlet & outlet gas lines with flow rates adjustable through needle valves. A temperature controller and pressure gauge are provided. The GC can thus work without interruption while the column gets conditioned separately.

View Complete Details

Headspace Sampler

Designed primarily for use with Sigma make Automated GC Model 606. It can be connected to any make GC with proper attachment. The features includes 6 vials of 20ml capacity, temperature controller having range from ambient to200 DegCwith accuracy of+0.1 Deg Cto heat vial block, gas sampling valve, sample loop & samples transfer line. Sequences of Head space sampler like pressurizing, depressurizing samples injection & flushing are done through time event relay provided in GC.

View Complete Details

Combined Nitrogen

The generator produces Nitrogen and Zero Air of GC grade purity sufficient for use with up to 2 GCs. It employs pressure swing adsorption technology to produce continuous supply of high purity gas. An oil free air compressor delivers filtered compressed air to a bed of Carbon Molecular Sieve and activated alumina. The adsorbent bed alternates
between purification and regeneration mode. Oxygen, moisture and other contaminants are removed to deliver pure, dry Nitrogen gas for use.

Additionally the compressed air is delivered to a bed of molecular sieve & activated alumina to remove water vapor, hydrocarbons and other impurities.

View Complete Details

Laboratory Tubular Split

Has been primarily developed for use in catalysis R & D labs and chemical engineering pilot plants. Each furnace has a height of 6 inches and outer diameter of 5 inches. The inner dia can be , 1/2, 1 or 1 inches. The furnace weighs about four kilograms. The inner tube is constructed of metal block of special alloy having high Thermal Conductivity which ensures high heat transfer rates allowing good temperature control. The construction is split-open type. It can be electrically heated upto550 Deg. C.For higher temperature, such furnaces can be specially constructed.

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us