Our Products
Industrial Coverall
2 Products availablePesticides & Insecticides
2 Products availableOur product range contains a wide range of Corrosion Inhibitor For Oil Line, Corrosion Inhibitor For Water Injection and Acid Corrosion Inhibitor
Physical State :The material shell be a free flowing homogenous liquid at 24±2o C, free from visible impurities Viscosity of the product at 300 rpm using a fann VG Mater or Equipment at 24 ± 2oC cp - 200 (maximum) Corrosivity of the Neat Product, mpy -1.0 (maximum) Compatibility and Emulstication : The material shall be compatible with the mixture and shall not from emulsion. Tendency of the Product with a Mixture of Untreated Crude Oil Mix (prepared by mixing 140 ml of Crude Oil with 60 ml of AR Grade Xylene) and Brine Corrodant at 24 ± 2oC :The interface sludge pad thickness shall not be more then 5% after five houre. Thermal Stability Test :The material shall be stable up to 80 ± 2oC Performance Tests :
Performance Evaluation :Calculate the Efficincy of the Inhibitor by comparing the Weight Loss of the Coupon in inhibited System with that in Uninhibited System(Blank test without inhibotor addition) after tests under both Static And Dynemic Conditions and Visually examine the condition of the Coupons efter each test : Inhibition Efficiency of the corrosion inhibitor should not be less then 80% in each case of static and dynemic Tests. Inhibited Test Coupons shall be free erom pits and scratches on visual inspection, under Static as well as Dynamic test condition. Note :The Source of Crude Oil is to be specified for individual requirments of different Assets. Paking :New HDPE Barrel containing 190 kg Material of type 2A Class-L quality conforming to IS-6312 / IMDG mark capacity 220 litres Marking :Each barrel should have clear legible marking as given below :
Physical State :The material shell be in the form of homogenous and free flowing liquid at 24±2o C and shall be free from visible impurities Miscibility and compatibility with sea water : Should be miscible and compatible Compatibility with other water injuction chemicals in use : should pass compatibility test Thermal Stability Test :should be stable up to 90 ± 5oC Viscosity of Neat Corrosion Inhibitor at 300 rpm at 24 ± o using a Fann VG Meter or Equivalent : 200 (Maximum) Corrosivity of Neat Product Product with API Steel coupon when exposed for 7 days at ambient temperature under open conditions, mpy : 1.0 (Maximum) Performance Tests :
Performance Evaluation :Calculate the Efficincy of the Inhibitor by comparing the Weight Loss of the Coupon in inhibited System with that in Uninhibited System(Blank test without inhibotor addition) after tests under both Static And Dynemic Conditions and Visually examine the condition of the Coupons after each test : Inhibition Efficiency of the corrosion inhibitor should not be less then 80% in each case of static and dynemic tests. Inhibited Test Coupons shall be free from pits and scratches on visual inspection, under Static as well as Dynamic test condition. Note :In case compatibility (at SL no. 3) is also to be seen with bactericides, same shall be specified by concerned user group Asset / Basin Paking :New HDPE Barrel containing 180 kg net material of capacity 220 it and IS6312 / IMDG mark. Marking :Each barrel should have clear legible marking as given below :
Being a distinguished Manufacturer, Supplier and Exporter of Acid Corrosion Inhibitor, we endeavor to achieve 100% customer satisfaction. Our wide range is manufactured using first-rate raw material. We meet the highest standards and parameters of quality set by the industry. Its optimum performance, high purity and longer shelf life set it apart from the rest. It is available for economical prices.
Corrosion Test :
Test Parameters | Inhibitor Type |
Grade II | |
Test Temperature, oC | 120±2 |
Test Pressure, Psi | 1000 |
Condition of test | Static |
Duration of Test hours | 6 |
Acid Volume / Test coupan Surface Area ml / sq inches | 75 |
Type of Steel | N - 80 |
Type of Acid | Hydrochloric (15% w/w ) |
Concentration of inhibitor ml / litre | 30 |
Results Reequired | |
Corrosion without pitting, g/cm2(maximum) | 0.024 |