Post Buy Requirement
SE

Shakti Electrical Corporation

Add Review

Transformers

Leading Manufacturer, Supplier & Retailer of Isolation Transformer, Step down transformer, Step Down And Step Up / Booster Transformers, Distribution Transformers and step down transformers.

Isolation Transformer

An isolation transformer is a device which is used to decouple two circuits, the load connected to the output of Isolation transformer and to the input supply. Isolation transformer suppresses electrical noises which occur in the Transmission line, because of the other loads connected in parallel.

Shakti isolation transformer provided with Electromagnetic & Electrostatic shielding block transmission of DC signals from one Circuit to other but allows AC signal to transmit. It also prevents interference caused by ground loop.

Few Features of Shakti Isolation Transformer are:

  • Isolation of primary winding and secondary windings.
  • Electromagnetic & Electrostatic shielding.
  • Very Low Coupling Capacitance.
  • Provide isolated neutral.
  • Protects micro processor based equipment from dangerous noises and reduces failures.
  • Can be useful where machine earth cant be used.
  • By Providing Delta star isolation transformer in 3-ph models, the problem of earth or neutral in the input side is taken care for the safe operation of the load.
  • It arrest the noises of high frequency and noises generated by the usage of high current MCB, ACB, Induction furnace or other electro magnetic noises.
View Complete Details

Step Down Transformer

  • voltage 110/120 V, 1-Ph or 200/220 V
Step down transformer are designed, manufactured and supplied against specific requirement of supply voltage for the equipment. e.g. Equipments imported from American Countries work on supply voltage of 110120 V, 1-Ph or 200220 V, 3-Ph. Depending upon the type of equipment, Step up step down transformers can be supplied in both auto wound type or isolated type. Similarly step up or booster transformers are supplied for the areas, where the supply voltage is usually very low.
View Complete Details

Step Down And Step Up / Booster Transformers

All these transformers are designed, manufactured and supplied against specific requirement of supply voltage for the equipment. e.g. Equipments imported from American Countries work on supply voltage of 110/120 V, 1-Ph or 200/220 V, 3-Ph. Depending upon the type of equipment, Step up/ step down transformers can be supplied in both auto wound type or isolated type.

Similarly step up or booster transformers are supplied for the areas, where the supply voltage is usually very low.

View Complete Details

Distribution Transformers

  • Standard All transformers are designed manufactured and tested as per IS-1180 & IS-2026 (or any other prevailing standard)
  • Capacity 16 KVA to 2500 KVA
  • Type Indoor or Outdoor
  • Rated Voltage HV : 33 KV, 11 KV , 6.6 KV or 3.3 KV, LV : 11 KV, 6.6 KV, 3.3 KV or 0.433 KV
  • Cooling Naturally oil cooled (ONAN)
  • Conductor Aluminium (up to 500 KVA )/ Copper.
  • Vector Group Dyn-11 ( or any other group as per requirement)
  • Connection Terminals LV : Suitable Brass Metal Parts covered with porcelain Bushings up to 400 Kva and Epoxy Moulded Copper Bus - bar type metal part for 500 Kva and above.
  • Temperature Rise 45 C for oil & 55 C for windings.
  • Tappings 5 % in steps of 2.5 % (Other ranges also available as per requirement)
Standard Fittings

  • Aluminium plate with transformer details & diagram
  • Oil level indicator ( Flush type )
  • Conservator with oil filling point
  • Drain point with valve & plug
  • Filter point with valve & plug
  • Thermometer pocket
  • Thermometer ( Dial Type )
  • Lifting hooks (4 Nos )
  • Air release plug
  • Silica Gel Breather
  • Explosion vent pipe
  • Mounting channel
  • Earthing Terminals (2 Nos)
  • Radiators ( Fixed Type )
  • LT Cable Box
  • Unidirectional rollers
  • Bus bar arrangement ( above 315 KVA)
  • HT bushings with arcing horns
  • Inspection Window (250 KVA & above )
  • Additional neutral bushings for connecting to separate earth.
Optional Fittings
  • Winding Temperature Indicator (WTI)
  • Oil Temperature Indicator (OTI)
  • Magnetic oil level Gauge (MOG)
  • Buchholz Relay
  • Detachable Radiators
  • Marshalling Box (500 KVA & above )
  • HT Cable Box
  • Off load type tap changing switch ( Externally operated)
  • On Load Tap Changing Switch (OLTC) with Auto Regulator & RTCC.
Transformer DetailsDesign

All transformers are designed as per customer specific requirement keeping in mind the stringent requirements of prevailing standards to ensure long & trouble free working of the transformer,

Winding

Transformer Coils are made from paper covered or super enameled high quality copper or aluminium conductors of EC grade. Windings are done so as to meet all three fundamental requirements i.e. Mechanical, Electrical & Thermal.
Press board washers & spacers rigidly support the winding. Interlayer cooling ducts are provided to ensure that the temperature gradient between winding & oil hense the hot temperature spot is minimized & high life expectancy is achieved.,

InsulationThe insulating material is selected keeping in mind electrical mechanical & thermal properties of it. The principle component of insulation is pre-fabricated press board sheet.CoreAll Transformers are made with firm interleaved low loss cold rolled grain oriented (CRGO) silicon steel laminations with mitred joint design to ensure low losses, low magnetizing current & low noise. Stamping has insulating material coating on both side which is oil & heat resistant.TankAll tanks are made from hot rolled mild steel plates which are electrically welded. Suitable stiffeners are provided for robust construction. Sufficient cooling radiators made from pressed steel fins or elliptical tubs are provided to maintain the temperature rise within specified limits. All tanks are pressure tested before painting to ensure zero leakage.PaintTransformer Tank & all other fabricated items are thoroughly cleaned before painting. The interior of the tank is painted with two coats of oil & heat resistant zinc chromate primer. It is also applied to the tank exterior before applying two coats of weather proof very durable anti corrosive epoxy based synthetic paint.OilThe oil used for insulation, impregnation and as a coolant complies to IS-335 Every consignment received is throughly tested for all parameters like di-electric strength, acidity, resistivity, flash point etc before use.TestingEach Transformer is properly tested for all routine tests as per IS : 2026 with best of the available testing panel and meters regularly calibrated from approved labs. Any other specific test can be done on special demand of the customer on initial agreement.After Sales ServiceShakti believes in building relations beyond business so special emphasis is given to quality assuring long and trouble free working of our products. Even then just in case there is any trouble in the unit our expert service engineer is promptly deputed for rectification of the problem. We have a team of highly skilled and well trained expect service engineer at your disposal at all time.
View Complete Details

Step Down Transformers

Step Down Transformers can be supplied in both auto wound type or isolated type.
View Complete Details

Step Up Transformers

Step Up Transformers are supplied for the areas, where the supply voltage is usually very low.
View Complete Details

Booster Transformers

Booster Transformers are supplied for the areas, where the supply voltage is usually very low.
View Complete Details
Tell Us What are you looking for? Will call you back