Our Products
Calibrators
2 Products availableData Loggers
2 Products availableIndustrial Valves
2 Products availableRotameters
2 Products availableWe offer a complete product range of Temperature Sensors, Temperature Sensor (Type J, Simplex), Plastic Water Flow Sensor, Liquid flow Helical Rotor sensor and meter and Turbine flow sensor
plastic helical rotorwater flow sensor is positive displacement base principle with low pressure loss, high accuracy and not depend on viscosity so its best option for dispensing and metering application for all liquid.
broil developed and designed helical rotor plastic water flow sensor withpulse output, fully inhouse facility including injection moulding machine and owen mould and tools,
Plastic flow sensor is best for water and liquid automatic dispensing machine, its also best for water AMR SYSTEM,
Water flow sensor pulse output :
Material of construction:
Enclosure : PA66 + GF
Rotor : PA66/POM/PPS
Shaft : Hard Stainless Steel-316
bearing : carbon/pom with hard S.S. BALL
Accuracy (standard installation position) : +/- 0.5 or 1% FSD
Repeatability : 0.05%
Maximum working pressure : 2.5 MPa
Fluid &Ambient temperature: -40 to 120 Deg. C
Connection: Thread (M)
1) Pulse output sensor :
a) Hall sensor
Power voltage: 5 to 24 V DC/ Low power: 2 to 5 V DC
Output signal: NPN open connector
Output:
high electric level : High than 4.5 VDC( input voltage 5 VDC)
low electric level : lower than 0.5 VDC( input voltage 5 VDC)
b) Reed sensor
c) pick up coil - two wire/ amplified three wire option
Helicalrotor water flow sensor model no wise Technical data:
Model no Connection(M) Range Pulse/Litter
BT-PHTFS-004 1/4 BSP 540400 L/H 4200
BT-PHTFS-008 1/2 BSP 101501500 L/H 1200
BT-PHTFS-012 3/4BSP 505005000 L/H 215
BT-PHTFS-020 1 BSP 8080008000 L/H97
BT-PHTFS-025 1.25 BSP 100100010000 L/H 52
BT-DFS-600 40 mm --1.5 Thread 72, 00L/H 29
BT-DFS-700 50 mm --2 Thread 10500L/H 14
Water flow sensor with food grade plastic material, Very good repetabilityworking temperature up to 120 deg cavailable with optional battery operated display and panel mount display
BROIL Developed and Produced helical rotor flow sensor specially for Liquid dispensing industries,
now a day liquid dispensing industries use plastic turbine flow sensor its k factor change with flow rate so
for solution we developer helical rotor plastic flow sensor with same pulse k factor for full range also provide
very good accuracy and repeatability in full range of measurement With very low pressure loss.
Plastic Helical flow meters are positive displacement meters with a very favorable low pressure drop behavior. therefore perfectly suited for the flow measurement of very high to low viscosity fluids. Due to wide measuring ranges, high accuracy and resolution helical flow meters are an excellent choice for laminating systems, painting systems, adhesive dispense systems, as well as batching systems for various fluids.
Tchnical specification of plastic helical rotor flow sensor and meter
Material of construction:
Enclosure : PA66 + GF
Rotor : PA66/POM/PPS
Shaft : Hard Stainless Steel-316
bearing : carbon/pom with hard S.S. BALL
Accuracy (standard installation position) : +/- 0.5 or 1% FSD
Repeatability : 0.05%
Maximum working pressure : 2.5 MPa
Fluid &Ambient temperature: -40 to 120 Deg. C
Connection: Thread (M)
1) Pulse output sensor :
a) Hall sensor
Power voltage: 5 to 24 V DC/ Low power: 2 to 5 V DC
Output signal: NPN open connector
Output:
high electric level : High than 4.5 VDC( input voltage 5 VDC)
low electric level : lower than 0.5 VDC( input voltage 5 VDC)
b) Reed sensor
c) pick up coil - two wire/ amplified three wire option
2) Battery operated meter :
Power voltage: 3.0 Vbatteries can be used more than 1 years in a row.
display mode:
Double row Liquid Crystal Display (LCD), as follows:
L XXX. X four instantaneous flow (m3 / h) or L/h
L XXXX. X Partial total (m3 / h) or L/h
XXXXX.X*100 eight cumulative flow (m3) or L
XXXXX.X*100 eight cumulative flow (m3) or L( never reset total)
Cumulative flow: automatically expand the display precision, the cumulative flow/partial values can be reset.
Power-fail protection: instrument coefficient, the Total flow values ten years is not lost when power supply drop.
3) Display with 4 to 20 mA Output
Power voltage: 24 V DC
Output signal: 4 TO 20 mA
Helical flow sensor model no wise Technical data:
Model no Connection(M) Range Pulse/Litter
BT-PHTFS-004 1/4 BSP 540400 L/H 4200
BT-PHTFS-008 1/2 BSP 101501500 L/H 1200
BT-PHTFS-012 3/4BSP 505005000 L/H 215
BT-PHTFS-020 1 BSP 8080008000 L/H 97
BT-PHTFS-025 1.25 BSP 100100010000 L/H 52
Turbine flow sensor heart is high accurate and balanced turbine rotor and pickup coil, mehaniccal energy ( velocity) of fluid passing through the flow meter rotate a rotor, an angular velocity of rotor proportional to fluid flow rate (mechanical energy /velocity) in the flow path , through pickup coil generate electrical frequency proportional to angular velocity of turbine rotor, and flow rate of fluid,
Turbine flow sensor output is direct pick up coil / amplified pulse/ linear current or voltage
Turbine flow sensor with explosion proof headTurbine flow sensor with two pulse output for custody transfer appliction,
Broiltech RTD temperature sensor is fine accuracy and CE certified temperature sensor.Broiltech RTD temperature sensor available in with: PT-100, PT-1000 AND PT-10 element, with different material of construction and dimension as per customer requirement.
1) RTD PT-100 Temperature Sensor (simplex/Duplex)
RTD, PT-100/1000/10 Temperature Sensor
Certificate: CE
Principle: basic physical property of a metal is that its electrical resistivity changes with temperature.
Type: 2/3 Wire, simplex /duplex
Sheath Dia: minimum 1 mm to 20 mm
Sheath Length: minimum 10mm to as you require
Sheath material: S.S-304/310/316/446, Nickel, Inconel-601, Incoloy-800, Ceramic Tube, Porcelain, Aluminum Oxide
Accuracy: As Per Din/ANSI Std.
Construction: simplex/duplex/triplex
Termination Head: Weatherproof/Explosion proof/Plug/Bare wire
Connection: Standard Thread/Flange/Tri-clover (as you require)
Insulation: ceramic BID/MGO powder/mineral insulated
Minimum: -200C to maximum 650C^
Head : Cast Al. Weatherproof OR 2.5 Meter S.S. Breaded Teflon Cable
RTD Platinum temperature sensor is CE certified, available in flamproof and wetherproof enclosure, available in CLASS-A/B accuracy
Helical rotor polycarbonate flow meter and sensor
Material of construction:
Enclosure :PC + GF
Rotor : PA66/POM/PPS
Shaft : Hard Stainless Steel-316
bearing : carbon/pom with hard S.S. BALL
Accuracy (standard installation position) : +/- 0.5 or 1% FSD
Repeatability : 0.05%
Maximum working pressure : 2.5 MPa
Fluid &Ambient temperature: -40 to 120 Deg. C
Connection: Thread (M)
1) Pulse output sensor :
a) Hall sensor
Power voltage: 5 to 24 V DC/ Low power: 2 to 5 V DC
Output signal: NPN open connector
Output:
high electric level : High than 4.5 VDC( input voltage 5 VDC)
low electric level : lower than 0.5 VDC( input voltage 5 VDC)
b) Reed sensor
c) pick up coil - two wire/ amplified three wire option
2) Battery operated meter :
Power voltage: 3.0 Vbatteries can be used more than 1 years in a row.
display mode:
Double row Liquid Crystal Display (LCD), as follows:
L XXX. X four instantaneous flow (m3 / h) or L/h
L XXXX. X Partial total (m3 / h) or L/h
XXXXX.X*100 eight cumulative flow (m3) or L
XXXXX.X*100 eight cumulative flow (m3) or L( never reset total)
Cumulative flow: automatically expand the display precision, the cumulative flow/partial values can be reset.
Power-fail protection: instrument coefficient, the Total flow values ten years is not lost when power supply drop.
3) Display with 4 to 20 mA Output
Power voltage: 24 V DC
Output signal: 4 TO 20 mA
Helical flow sensor model no wise Technical data:
Model no Connection(M) Range Pulse/Litter
BT-PHTFS-004 1/4 BSP 540400 L/H 4200
BT-PHTFS-008 1/2 BSP 101501500 L/H 1200
BT-PHTFS-012 3/4BSP 505005000 L/H 215
BT-PHTFS-020 1 BSP 8080008000 L/H 97
BT-PHTFS-025 1.25 BSP 100100010000 L/H 52