Our Products
Calibrators
2 Products availableData Loggers
2 Products availableIndustrial Valves
2 Products availableRotameters
2 Products availableWe offer a complete product range of Circular Chart Recorders, Turbine Type Flow Meter, Electromagnetic Flow Meter, Fuel Consumption Meter and Oval Gear Flow Meter
Dieselenginefuel consumption meteris creation from two Diesel flow sensor and one fuel calculator, full product is design, developed and tested by broiltech, and successfully run from last three years.
Broiltech fuel sensor is oval gear flow sensor, its measure and calculate total diesel quantity pass from
diesel tank to engine (a) and excess diesel return from engine to diesel tank (b), and after know both
diesel quantity its easy to calculate total fuel consumption of diesel generator (c) = (a) - (b),
and its our surety that our system accuracy: 0.5 % of real consumption.
Broiltech fuel calculator measure and calculate both fuel flow sensor fuel qty, fuel passing time and fuel consumptionalso broiltech fuel calculator optionally able to provide RS-485/RS-232 / pulse output against fix use qty for connectwith GPS and GPRS modem.
Technical data:
1) diesel flow sensor :one for inlet line and second for return line
Enclosure : Aluminum anodize
sensing element : Aluminum anodize oval gear
Accuracy (standard installation position):0.1 % fsd
power: 5 vdc to 24 vdc
diesel flow sensor selection:
Bt-DOFS-006 ------- up to 200 HP Diesel Engines
Bt-DOFS-008-------- 200 HP TO 400 HP Diesel Engines
BT-DOFS-012------- 400 HP TO 1000 HP Diesel Engines
BT-DOFS-020------- 1000 HP TO 1500 HP Diesel Engines
BT-DOFS-025------- 1500 HP TO 2000 HP Diesel Engines
Fuel calculator:
Fuel calculator with inbuild data logging and checking memory & extended usb port for data syncronize
Display: inline, return line and consume fuel qty and time, and flow rate
Measure unit: selection available: litter/gallon/meter3 and many moreStandard unit
Power: 5 Vdc to 24 Vdc
Calibration: easy to calibrate both connect fuel flow sensor
Option:
Fuel consumption meteravailable with digital output for connect to GPRS or GPS systemAvailable with GPS and GPRS system to monitoring vehicle fuel data via computer
Future:
Diesel generator fuel consumption meter available with bellow mention future:
Fuel calculator with inbuild data logging and checking memory & extended usb port for data syncronize- Indicate total fuel consumption by diesel engine- Indicate total fuel supply toward engine- Indicate total fuel return from engine- indicate total time of fuel consume with fuel supply and return time- indicate flow rate of inline and return line- Fuel measurement via positive displacement Base principle- Suitable with all diesel engine- On board power supply from engine battery 5vdc TO 29 VDC- It define you an accurate consumption of fuel so difficult to theft fuel from vehicle
Oval gear fuel flow meter is a positive displacement volumatric flow meter, available with RS485/Pulse/Current/Hart output and inbuild flowrate and totalize digital display,
positive displacement flow measurmenthas accuarate and precision teethed two oval shape gear, Gear rotate when flow pass on measuring chamber and Magnetic pickup sensor/ Hall sensor use for measuring rotation of gear, and each rotation equal to fix value of fluidvolume,
Digital Fuel Flow Meteravailable with :
--- Inline battery operated digital display
--- 4 to 20 mA output inline digital display
--- Panel mount digital display
--- Mechanical counter flow meter
Technical specification:
CE certified product
Working principle: oval gear positive displacement
Accuracy (standard installation position) : 0.1% FSD or 0.5%RSRepetability :0.01 %
Maximum working pressure:
MPa = 50 bar for aluminum body
MPa = 250 bar for s.s. body
above 250 bar please contact company
Fluid &Ambient temperature: -40 to 150C
Power voltage: 3 - 24V DC
Material of construction:
Rotor and casing : Aluminum anodize/ PPS/S.S-316O-ring : NBR/VITON/SILICONShaft : Stainless Steel/ hastelloy
1)Battery operated fuel flow meter:
Power voltage: 3.3 V10AH lithium batteries can be used more than 5 years in a row.
display mode:
Double row Liquid Crystal Display (LCD), as follows:
L XXX. X four instantaneous flow (m3 / h) or L/h
XX. XXXXXX eight cumulative flow (m3) or L
Cumulative flow: automatically expand the display precision, the cumulative flow values can be reset.
Power-fail protection: instrument coefficient, the Total flow values ten years is not lost when power supply drop.
2)Fuel flow meter Display with 4 to 20 mA Output
Power voltage: 24 V DC
Output signal: 4 TO 20 mA
optional : RS-485: HART protocol
Broiltech is producer of CE certified oval gear flow meter for measuring flow of fuel, kerosene, Gasoline, diesel, light oil, heavy oil, petrol , LDO, HDO, and other high viscous liquied.BROILTECH brand fuel flow meter is high accuracy oval gear positive displacement flow sensor,
Model no Line size Range Litter/pulse |
BT-DOFS-003 4mm-- 1/4” Thread 0.05~30L/H 0.000333 L/P |
BT-DOFS-004 4mm --1/4” Thread 0.2~60L/H 0.000416 L/P |
BT-DOFS-006 6mm --1/4” Thread 5~150L/H 0.000661 L/P |
BT-DOFS-008 8 mm--3/8” Thread 20~300L/H 0.0025 L/P |
BT-DOFS-012 12 mm--½” Thread 50~1200L/H 0.0025 L/P |
BT-DOFS-020 20 mm--3/4” Thread 150~2,000L/H 0.0154 L/P |
BT-DOFS-025 25 mm--1” Thread 200~4,000L/H 0.0256 L/P |
BT-DOFS-040 40 mm-- 1.5” Flange 00~10,000L/H 0.086 L/P |
BT-DOFS-050 50 mm-- 2” Flange 600~20,000L/H 0.19 L/P |
BT-DOFS-080 80 mm -- 3” Flange 1,000~50,000L/H 0.54 L/P |
BT-DOFS-100 100 mm-- 4” Flange 2,000~100,000L/H 1.0 L/P |
BT-DOFS-150 150 mm-- 4” Flange 5,000~150,000L/H 3.2 L/P |
Indiginiously design and developed precision oval gear for positive displacement flow sensor with pulse/ 4 to 20 mA/ RS 485 output,
Its measuring flow volume with two oval shape gear, Gear rotate when flow pass on measuring chamber and magnetic pickup sensor use for measuring nos of rotation of gear, and each rotation equal to fixvolume of fluid.
Oval gear fuel flow sensor technical specification:
CE certified product
Working principle: oval gear positive displacement
Accuracy (standard installation position) : 0.1% FSD or 0.5%RSRepeatability : 0.01%
Output signal: NPN Open collector : 5 vdc to 24 v dc
REED switch : 30 vdcMagnetic pickup coil : 12v dc to 24v dc
Maximum working pressure:
MPa = 50 bar for aluminum body
MPa = 250 bar for s.s. body
above 250 bar please contact company
Fluid &Ambient temperature: -40 to80/120/150C
Material of construction:
Rotor and casing : Aluminum anodize/ PPS/S.S-316
O-ring : NBR/VITON/SILICON
Shaft : Stainless Steel/ hastelloy
Model no Line size Range Litter/pulse
BT-DOFS-003 4mm-- 1/4 Thread 0.0530L/H 0.000333 L/P
BT-DOFS-004 4mm --1/4 Thread 0.260L/H 0.000416 L/P
BT-DOFS-006 6mm --1/4 Thread 5150L/H 0.000661 L/P
BT-DOFS-008 8 mm--3/8 Thread 20300L/H 0.0025 L/P
BT-DOFS-012 12 mm-- Thread 501200L/H 0.0025 L/P
BT-DOFS-020 20 mm--3/4 Thread 1502, 000L/H 0.0154 L/P
BT-DOFS-025 25 mm--1 Thread 2004, 000L/H 0.0256 L/P
BT-DOFS-040 40 mm-- 1.5 Flange 0010, 000L/H 0.086 L/P
BT-DOFS-050 50 mm-- 2 Flange 60020, 000L/H 0.19 L/P
BT-DOFS-080 80 mm -- 3 Flange 1, 00050, 000L/H 0.54 L/P
BT-DOFS-100 100 mm-- 4 Flange 2, 000100, 000L/H 1.0 L/P
BT-DOFS-150 150 mm-- 4 Flange 5, 000150, 000L/H 3.2 L/P
BROILTECH brand fuel flow sensor is high accuracy oval gear positive displacement flow sensor, its provide voltage pulse output against fuel flow volume.
Fuel flow sensor also available with optional linear voltage and current output its known as flow transmitter,
Fuel flow sensor available from minimum line size3 mm to maximum line size 150 mm,
Fuel flow sensor flow range start from 0.2 litter/hour to 1, 50, 000 litter/hour,
Fuel flow sensor available with NPN open connector and reed switch base pulse outputmodal aproved by legal metrology ( weight & measurement) india
BROILTECH Mechanical display oval gear positive displacementoil flow meter start from 25mm to 50 mm line size, analoge fuel flow meter available in threaded as well as flange conection,
Mechanical gear flow meter is best for application like : oil flow meter, diesel flow meter, petrol fuel flow meter, its best for any viscosity
Mechanical oval gear fuel flow metertechnical specification:
CE certified product
Working principle: oval gear positive displacement
Accuracy (standard installation position) : 0.5% FSD
Repeatability: 0.03%
Maximum working pressure: 2 MPa = 20 bar
Fluid &Ambient temperature: -40 to80C
Viscosity : 1000 cps maximum
Material of construction:
Rotor and casing : Aluminum anodize/S.S-316
O-ring : NBR/VITON/SILICON
Shaft : Stainless Steel
Process connection: standard thread
Flow range: as on bellow model no wise table
25mm mechanical fuel flow meterMODEL: BT OFMM- 025
Flow range: 20 TO 120 litter/Minuit
Accuracy : 0.5% FSD
40 mm mechanical fuel flow meterMODEL: BT-OFMM -40
Flow range: 25 TO 250 litter/Minuit
Accuracy : 0.5 % FSD
50mm analoge fuel flow meterMODEL: BT-OFMM-050
Flow range: 30 TO 300 litter/Minuit
Accuracy : 0.5 % FSD
Broiltech is producer of CE certified Mechanical oval gear flowmeter for measuring flow of fuel, kerosene, Gasoline, diesel, light oil, heavy oil, petrol , LDO, HDO, and other high viscous liquied.
BROILTECH brand fuel flow meteris high accuracy oval gear positive displacement flow meter, itsavailable with mechnical display so not require any power source,
Mechanical Fuel flow meteravailable from minimum line size 25 mm to maximum line size 50 mm,
Helical rotor Positive displacement base DIGITAL WATER FLOW METER developed by "BROILTECH" indiginiously first time in world for water industries,
Helical rotor Digital Water Meter design is proven for best accuracy and low pressure loss than turbine and oval gear, so customer got more flow rate and low power consumption, its also not effected on viscosity of liquied and temp. change.
its also use for various liquied flow measurement from low to high viscousity
digital water flow meter technical specification:
Model No: BT- PHTFS-D
Manufacturer: BROILTECH
Material of construction:
Enclosure : PA66 + GF
Rotor : PA66/POM/PPS
Shaft : Hard Stainless Steel-316
bearing : carbon/pom with hard S.S. BALL
Accuracy (standard installation position) : +/- 0.5 or 1% FSD
Repeatability : 0.05%
Maximum working pressure : 2.5 MPa
Fluid &Ambient temperature: -40 to 120 Deg. C
Connection: Thread (M)
1) Battery operated meter :
Power voltage: 3.0 Vbatteries can be used more than 1 years in a row.
display mode:
Double row Liquid Crystal Display (LCD), as follows:
L XXX. X four instantaneous flow (m3 / h) or L/h
L XXXX. X Partial total (m3 / h) or L/h
XXXXX.X*100 eight cumulative flow (m3) or L
XXXXX.X*100 eight cumulative flow (m3) or L( never reset total)
Cumulative flow: automatically expand the display precision, the cumulative flow/partial values can be reset.
Power-fail protection: instrument coefficient, the Total flow values ten years is not lost when power supply drop.
2) Display with 4 to 20 mA Output
Power voltage: 24 V DC
Output signal: 4 TO 20 mA
Helical flow Metermodel no wise Technical data:
Model no Connection(M) Range
BT-PHTFS-004 1/4 BSP 540400 L/H
BT-PHTFS-008 1/2 BSP 101501500 L/H
BT-PHTFS-012 3/4BSP 505005000 L/H
BT-PHTFS-020 1 BSP 8080008000 L/H
BT-PHTFS-025 1.25 BSP 100100010000 L/H
BT-DFS-600 40 mm --1.5 Thread 72, 00L/H
BT-DFS-700 50 mm --2 Thread 10500L/H
digital water flow meter is best economical solution of water consumption measurement at industrial and residential application, digital water flow meter available with battery operated display plus optional pulse output for water billing system and WATER AMR application
Fully stainless steel Helical flow meters are positive displacement meters with a very favorable low pressure drop behavior. therefore perfectly suited for the flow measurement of very high viscosity fluids. Due to wide measuring ranges, high accuracy and resolution helical flow meters are an excellent choice for laminating systems, painting systems, adhesive dispense systems, as well as batching systems for various fluids.
Helical Rotor flow sensor / meter General Technical data:
Material of construction:
Enclosure : S.S-304/S.S-316
Rotor : S.S-304/Titanium/ Aluminumanodized
Shaft : Hard Stainless Steel-316 withcarbon Bearing
Accuracy : +/- 0.5 or 1% FSD
Repeatability : 0.1%
Maximum working pressure: 6 MPa
Fluid &Ambient temperature: -20 to 120 Deg. C
Connection: Thread (M/F) or flange
1) Pulse output Helical flow sensor:
Power voltage: 12 V DC
Output signal: NPN open connector
Output:
high electric level : High than 8 VDC( input voltage 12 VDC)
low electric level : lower than 0.8 VDC( input voltage 12 VDC)
2) Battery operated helical flow meter:
Power voltage: 3.3 V10AH lithium batteries can be used more than 5 years in a row.
display mode:
Double row Liquid Crystal Display (LCD), as follows:
L XXX. X four instantaneous flow (m3 / h) or L/h
XX. XXXXXX eight cumulative flow (m3) or L
Cumulative flow: automatically expand the display precision, the cumulative flow values can be reset.Power-fail protection: instrument coefficient, the Total flow values ten years is not lost when power supply drop.
3) Helical rotor flow meter with 4 to 20 mA Output:
Power voltage: 24 V DC
Output signal: 4 TO 20 mA
Helical rotorflow sensor and meter model no wise Technical data:
Model no Line size Range
BT-HTFS-004 04 mm 40400 L/H
BT-HTFS-012 12 mm 6006000 L/H
BT-HTFS-025 25 mm 100010000 L/H
BT-HTFS-040 40 mm 200020000 L/H
BT-HTFS-050 50 mm 400040000 L/H
BT-HTFS-080 80 mm 10000100000 L/H
BT-HTFS-100 100 mm 20000200000 L/H
BT-HTFS-150 150 mm 30000300000 L/H
BT-HTFS-200 200 mm 80000800000 L/H
Applications:Polyurethane and polymer
Light and heavy fuel oil
Petrochemical products
Thixotropical fluids
Fat and oils with varying viscosities
Hydraulic test rigs with varying viscosities and fluids
Water / glycol mixtures
Crude oil, furnace oil, and all viscous liquid even viscosity change withTemperature
Hygienic liquied and sanitary application special full S.S.- 316 liquid turbine flowmeterproduced by broiltech for water, food, beverage and pharmacy application,
Liquidflow sensor / meterGeneral Technical data:
Material of construction:
Enclosure: S.S-316
Rotor: S.S-304
Shaft: Hard Stainless Steel-316 with
carbon bush
Accuracy: +/-0.5 or 1%FSD
Repeatability: 0.1%
Maximum working pressure: 6 MPa
Fluid &Ambient temperature: -20 to 120 Deg. C
Connection:Triclamp conection
1) Pulse output sensor:
Power voltage: 12 V DC
Output signal: NPN open connector
Output:
high electric level : High than 8 VDC( input voltage 12 VDC)
low electric level: lower than 0.8 VDC( input voltage 12 VDC)
2) Battery operated meter:
Power voltage: 3.3 V10AH lithium batteries can be used more than 5 years in a row.
display mode:
Double row Liquid Crystal Display (LCD), as follows:
L XXX. Xfour instantaneous flow (m3 / h) or L/h
XX. XXXXXX eight cumulative flow (m3)or L
Cumulative flow: automatically expand the display precision, the cumulative flow values can be reset.
Power-fail protection: instrument coefficient, the Total flow values ten years is not lost when power supply drop.
3) Display with 4 to 20 mA Output
Power voltage: 24 V DC
Output signal: 4 TO 20 mA
Turbine flow sensormodel no wise Technical data:
Model noLine sizeRange
BT-DTFS-00404 mm40400 L/H
BT-DTFS-01212 mm6006000 L/H
BT-DTFS-02525 mm100010000 L/H
BT-DTFS-04040 mm200020000 L/H
BT-DTFS-05050 mm400040000 L/H
BT-DTFS-08080 mm10000100000 L/H
BT-DTFS-100100 mm20000200000 L/H
BT-DTFS-150150 mm30000300000 L/H
BT-DTFS-200200 mm80000800000 L/H
producer and developer of turbine flow meter from minimum line size 4 mm to maximum 400 mm, above 400 mm produced as per customer requirement,
Turbine flow meter is best for measuring flow of liquied and gas,
Turbine flow meter available with1) inline battery operated display ( EX OR ip-65)2) 4 to 20mA output 2wire display(EX)3) 4 to 20mA + RS 485 output diplay( EX)4) 4 to 20mA + HART output diplay( EX)
Turbine flow meter General Technical data:
Material of construction:
Enclosure : S.S-304/S.S-316
Rotor : S.S-304
Shaft : Hard Stainless Steel-316 withcarbon bush
Accuracy : +/- 0.2% or 0.5 % FSD
Connection : Thread (M/F) or flange
1) Battery operated Turbine flow meter :
Power voltage: 3.3 V10AH lithium batteries can be used more than 5 years in a row.
display mode:
Double row Liquid Crystal Display (LCD), as follows:
L XXX. X four instantaneous flow (m3 / h) or L/h
XX. XXXXXX eight cumulative flow (m3) or L
Cumulative flow: automatically expand the display precision, the cumulative flow values can be reset.Power-fail protection: instrument coefficient, the Total flow values ten years is not lost when power supply drop.
2) Turbine flow meter with 4 to 20 mA Output
Power voltage: 24 V DC
Output signal: 4 TO 20 mAOptional: RS 485
Turbine flowMetermodel no wise Technical data:
Model no Line size Range
BT-DTFS-004 04 mm 40400 L/H
BT-DTFS-012 12 mm 6006000 L/H
BT-DTFS-025 25 mm 100010000 L/H
BT-DTFS-040 40 mm 200020000 L/H
BT-DTFS-050 50 mm 400040000 L/H
BT-DTFS-080 80 mm 10000100000 L/H
BT-DTFS-100 100 mm 20000200000 L/H
BT-DTFS-150 150 mm 30000300000 L/H
BT-DTFS-200 200 mm 80000800000 L/H
Special purpose Accurate and reliable electromegnetic flow meter and sensor for batching, BTU, heat calculation and measuring application. available with 24V DC , 230 v ac and battery operated power supply solution,
Broil senostek industries has Exclusive developed and produced this product BT MFT modal flow meter at india factory, its has no MID certificate, if you want MID Certification than we supply AFLOWT germany production,
"Electromagnetic Flow Meter "
Specification:
Parameter | Value |
Nominal diameter of the pipeline, DN | 15 1000 |
Accuracy, % | from 0.5% / 1% |
Maximum pipeline pressure, MPa/bar | 2.5/25 |
Minimum conductivity, S/cm | 5 |
Fluid temperature range, | minus 10 150 |
Ambient temperature range, | 5 50 |
Minimum straight pipe runs | 5 DN upstream and 2 DN downstream |
Protection | IP65 |
Power supply, VDC | 24, 230 v ac , battery operated |
LCD;
pulse outputs; logical and digital4 to 20 Ma outputalarm output ( high or low)
RS-485 interface (Modbus).
flanges and housing carbon steel / Stainless steel
lining PTFE;
electrodes stainless steel. hestroloy, titanium or customer require special material as per customer application
available in sizes from DN 15 to 10000 mm
bidirectional flow measurement (on request);
full-bore meter design eliminates pressure loss in measurement section;
no filtering required;
short straight pipe runs required for installation;
protection against unauthorized access;
Broil sensotek industriesVortex Flowmeterbases onKarman vortex streetPrincipalfor detection and metering the liquid, gas and steam. It is widely used in Petroleum, chemical, metallurgy, heat supply
industry, etc.
for steam and gas application available with pressure and temperature compensating,
1) Technical Specification :
Process media : Gas, liquid, air, steam, vapor
Enclosure :1Cr18Ni9Ti
Accuracy : +/- 0.5 for liquied,
: 1% for gas and steam
Repeatability : 0.2%
Flow range: Liquid:0.4-7.0m/s;
:Gas:4.0-60.0m/s;
:Steam:5.0-70.0m/s
Maximum working pressure: 6 MPa
Fluid &Ambient temperature: -40 to 350 Deg. C
Connection: Thread (M/F) or flange
2) DISPLAY
Power voltage: 3.3 V10AH lithium batteries can be used more than 5 years in a row. OR 24 v dc
display mode:
Liquid Crystal Display (LCD), as follows:
L XXX. X four instantaneous flow (m3 / h) or L/h
XX. XXXXXX eight cumulative flow (m3) or L
Pressure, temperature reading
Cumulative flow: automatically expand the display precision, the cumulative flow values can be reset.
Power-fail protection: instrument coefficient, the Total flow values ten years is not lost when power supply drop.
3) output:3 wire pulse
: 2 wire 4 to 20 mA
: RS-485
: HART
Measuring ranges for liquid : water
Flow rate: m3/hour
Line size |
Minimum flow rate |
Maximum flow rate |
O/P HZ range |
Temp. |
15 |
1 |
6 |
90-900 |
25°C |
20 |
1.2 |
8 |
40-600 |
25°C |
25 |
2 |
16 |
35-400 |
25°C |
32 |
2.2 |
20 |
20-250 |
25°C |
40 |
2.5 |
25 |
10-240 |
25°C |
50 |
3.5 |
35 |
8-190 |
25°C |
65 |
6 |
60 |
7-150 |
25°C |
80 |
13 |
130 |
6-110 |
25°C |
100 |
20 |
200 |
5-90 |
25°C |
125 |
30 |
300 |
4.5-76 |
25°C |
150 |
50 |
500 |
3.58-60 |
25°C |
200 |
100 |
1000 |
3.2-48 |
25°C |
250 |
150 |
1500 |
2.5-37.5 |
25°C |
300 |
200 |
2000 |
2.2-30.6 |
25°C |
Measuring ranges for gas : density : 1.12, and pressure 1 bar
Flow rate: m3/hour
Line size |
Minimum flow rate |
Maximum flow rate |
O/P HZ range |
Temp. |
15 |
5 |
30 |
460-3700 |
25°C |
20 |
6 |
50 |
220-3400 |
25°C |
25 |
8 |
60 |
180-2700 |
25°C |
32 |
14 |
100 |
130-1400 |
25°C |
40 |
18 |
180 |
90-1550 |
25°C |
50 |
30 |
300 |
80-1280 |
25°C |
65 |
50 |
500 |
60-900 |
25°C |
80 |
70 |
700 |
40-700 |
25°C |
100 |
100 |
1000 |
30-570 |
25°C |
125 |
150 |
1500 |
23-490 |
25°C |
150 |
200 |
2000 |
18-360 |
25°C |
200 |
400 |
4000 |
13-325 |
25°C |
250 |
600 |
6000 |
11-220 |
25°C |
300 |
1000 |
10000 |
9-210 |
25°C |
Measuring ranges for Saturated Steam : above 10 bar pressure please contact company
Flow rate: kg/hour
Pressure [Linesize] |
1 |
3 |
5 |
7 |
10 |
15 |
5-30 |
6.5-70 |
8-110 |
10-150 |
12-198 |
25 |
10-120 |
15-250 |
20-400 |
20-500 |
25-700 |
40 |
25-350 |
40-700 |
45-1100 |
50-1400 |
64-1928 |
50 |
48-600 |
65-1200 |
80-2000 |
95-2500 |
111-3340 |
80 |
100-1200 |
150-2500 |
180-4200 |
205-5400 |
250-7232 |
100 |
180-2300 |
250-4800 |
290-7200 |
360-8900 |
425-12400 |
150 |
400-4800 |
550-10000 |
700-16000 |
820-21000 |
980-28500 |
200 |
800-9800 |
1100-20000 |
1200-32000 |
1500-38500 |
1750-53800 |
250 |
1200-14000 |
1800-32000 |
21000-50000 |
2400-61500 |
27500-85000 |
300 |
1800-22000 |
2500-48000 |
30000-70000 |
3500-89000 |
41000-123500 |
Mechanical oval gear OIL flow meter
BT-RDOFM- line size
Broil sensotek industries, producer cast steel , cast iron, stainless steel and cast aluminium oval gear mechanical flow meter,
broil has variety of counter foroil flow meteras per customer requirement
1)only cumulative total, no resettable total
2)cumulative total + resettable total
3)cumulative total + pulse output/4 to 20 mA output
4)cumulative total + resettable total
+ pulse output/4 to 20 mA output
Broiltech is producer of CE certified mechanical oval gear fuel flow meter for measuring flow of fuel, kerosene, Gasoline, diesel, light oil, heavy oil, petrol , LDO, HDO, wine, bear, alcohol, milk, juice, coffee, tea, all chemical and pharmaceutical drug
BROILTECH brand fuel flow meter is high accuracy oval gear positive displacement flow meter.
MechanicalOil flow meter General Technical data:
CE certified product
Working principle: oval gear positive displacement
Accuracy (standard installation position) :0.5% FSD/ 0.2 %fsd
Repeatability: 0.03%
Maximum working pressure: 2 MPa = 20 bar
Fluid &Ambient temperature: -40 to100C
Viscosity : 1000 cps maximum
Material of construction:
Rotor and casing : cast iron / cast steel / stainless steel / aluminium
O-ring : NBR/VITON/SILICON
Shaft : Stainless Steel
Process connection: standard flange
Broil senostek industries has Exclusive collaborate with Germany & Russia producer for sales and service Ultrasonic flow meter,
leading GERMAN/RUSSIAN company for Electromagnetic flow meter /Ultrasonic flow meter / Vortex flow meter with OIML, MID, 2014/32/EC, EX , AND IP 65 APPROVAL,
Also production licencee for produce flow meter for nuclear power plant,
Ultrasonic flow meter battery operated
Advantages:OIML / MID 001 / 2014/32/EC certified
independent of power failure and power-off;
independent of water pollution level (filters not required);
no pressure loss in pipeline;
high stability of measurement;
electronic unit positioned directly on spool piece;
LCD on/off button for battery charge saving;
easy commissioning;
Application:residential water consumption metering (cold and hot tap water);
water consumption metering at industrial enterprises;
water metering at pipeline control points;
irrigation.
LCD;
Universal output;
RS-485 interface (Modbus)
wired or wireless M-Bus interface on request.
Portable Ultrasonic Digital flow meter
Broil senostek industries has Exclusive collaborate with Germany & Russia producer for sales and service Electromagnetic flow meter,
Leading GERMAN/RUSSIAN company for Electromagnetic flow meter /Ultrasonic flow meter / Vortex flow meter with OIML, MID, 2014/32/EC, EX , AND IP 65 APPROVAL,
Also production licencee for produce flow meter for nuclear power plant,
OIML / MID 001 / 2014/32/EC certified
digital data processing, short measuring time, high interference protection;
automatic adjustment;
reversible stream measurement in pipeline;
low frequency transformer for corrosion pipelines and liquids with high quantity of
hard particles;
mode for mass and heat calculation using volume, temperature and pressure
value;
sensor LCD, definition of 640*480;
SD-card zipping;
USD-interface;
impact-resistant case of IP 67;
explosion safe version.
Specification:
Parameter | Value |
Pipe size, DN, mm | 20 5 000 |
Flow velocity range, m/s | 0.1 20 |
Accuracy, % | from 1.5 |
Fluid temperature range, ? | minus 30 150 |
Ambient temperature for transmitter, ? | minus 10 50 |
Transmitter / transducers protection | IP67 |
Number of stored sets of site parameters | 200 |
Measurement and error data logging capacity, number of records | 100 000 |
Storage rate, s | 1 300 |
Power supply:- buttery, V- external power supply, VDC- via 220VAC/=12VDC charger | 3.6 1030220VAC 50Hz |
Battery uninterrupted operation, hrs. | up to 24 |
Transmitter weight, kg | under 3 |
Transmitter dimensions, mm | 285 250 125 |
LCD;
pulse output;
RS-232 interface;
USB.
digital data processing, short measuring time, high interference protection;
automatic adjustment;
BROILTECHThermal mass flow meter for detection and metering the gas and air. Its work on principal of calorie amount taken away from the heated sensor by a fluid flow is calibrated to the mass of flow,
Thermal mass flow meter use for measuring : air, nitrogen, argon, co2, chlorine, ethane, ethylene, methane, ammonia, helium, hydrogen, bio gas,
Thermal mass gas flow meter
1) Technical specification :
Type : Inline and Insertion
Medium : All kinds of gases (pure & stable except for acetylene)
Accuracy : 1%
Repeatability : 0.2% full scale meter
Ambient Temperature : -40C to 50C
Medium Temperature : -40C to 260 C
Environmental Pressure : 1 MPa, 2.5 MPa
Protection : Water Proof, Explosion Proof
Material of construction : S.S. 316 (Standard) other on request
INLINE TYPE CONECTION : FLANGE
,
2) DISPLAY
Power voltage: 85 v ac 250 v ac OR 24V DC 10%
display mode:
Liquid Crystal Display (LCD), as follows:
L XXX. X four instantaneous flow (m3 / h) or L/h
XX. XXXXXX eight cumulative flow (m3) or L
temperature reading
Cumulative flow: automatically expand the display precision, the cumulative flow values can be reset.
Power-fail protection: instrument coefficient, the Total flow values ten years is not lost when power supply drop.
3) output :3 wire pulse
: 2 wire 4 to 20 mA
: RS-485
: HART
Upper Range Value of Common Gas
(Unit: Nm3/h. The follow table can be extended)
The flow rate in standard condition: The flow rate is in the condition of 20?temperature and 101.325kPa pressure.
The unit of flow rate is optional: Nm3/h, Nm3/min, L/h, L/min, t/h, t/min, kg/h or kg/min.