Post Buy Requirement
ST

Servostar Transformer Ind.

Verified Add Review

Other Products / Services

We offer a complete product range of 3 Phase Servo Voltage Stablizer, LINEAR SERVO STABILIZER, ISOLATION & ULTRA ISOLATION TRANSFORMER, power conditioning electronic instruments and 3 phase voltage stabilizer system

Offline Ups

Output Voltage, AnalogDigital (Optional) (As per customer choice) LED & Microprocessor based Digital LCD metering for multipleparameters shall be provided as optional in Higher Capacities, Its AVR function allows Input Voltage range from 70% to 125%. It is based on micro controls and there it has fewer components and highest reliability. It has ability to take care of Overload, Over Voltage, and Battery under Voltage, Short circuit and Shut down. The LCD Digital display of UPS always keep the customer fully informed about the UPS condition.
View Complete Details

3 Phase Servo Voltage Stablizer

Servo Voltage Stabilizer is commonly observed that, AC main supply is never 230 Volt or 415 Volt, but varies from 150 Volt - 300 volt and 300 Volt - 500 Volt. The difficulties caused by them are well known, such as Over Load Condition, Line Losses, Poor Power Factor and several other reasons. The three phase servo voltage stabilizer helps in constant voltage which is required to load is never constant, but in fluctuation manner. It is observed that during the daytime, the voltage is quiet low and during the night the Voltage is high then the normal.

S.No. Parameter Single PhaseUnit Three Phase Unit
1 Rating 2 KVA to 50 KVA 6 KVA to 2000 KVA
2 Input Voltage Range a) 180V - 280V
b) 160V - 280V
c) 140V - 280V
a) 350V - 470V
b) 340V - 470V
c) 320V - 470V
d) 300V - 480V
e) 270V - 480V
f) 240V - 480V
3 Nominal Output Voltage 230V 400V
4 Output Voltage Accuracy ± 1% ± 1%
5 LineFrequency Variation 47Hz-53Hz 47Hz-53Hz
6 Effect of Power Factor None None
7 Wave Form Distortion None added None added
8 Control Digital/Analogue Digital/Analogue
9 Response Time 10 ms. 10m s.
10 Voltage Correction Rate
1. Air Cooled
2 Oil Cooled
25V / Sec.
15V/ Sec
40V / Sec
25V / Sec.
11 LCD Display (20 x 2 matrix) Date & Time, Input Voltage, Output Voltage & Current
12 Log book Memory (Non-volatile)
  • No. of Hrs. of operation on mains.
  • Peak Current demand.
  • Nos. of Abnormal High Voltage cut-off events.
  • Nos. of Abnormal Low Voltage cut-off events.
  • No. of Hrs. of operation on DG.
13 Programmable Features(Through 2-parallel way resettable passwords) HV cut-off set
.LV cut-off set.
O/L trip set
.Time delay set
Operating mode (auto/manual)
14 Cooling:
1. Air Cooled
2. Oil Cooled
2 KVA to 40 KVA & above
5 KVA to 1000 KVA & above
15 Efficiency 97%
16 Protection a) Automatic Switch-Off against:
· Under / Over-Voltage
· Over-Load & Short - Circuit
· Single Phasing
17 Surge Protection Class C Type Secondary surge Protection





















View Complete Details

Servo Stabilizer Single Phase

  • Efficiency >/- 98%
  • NPUT RANGES 1 PHASE 140-280V, 170-270V, 196-265V OR ANY OTHER INPUT RANGES AS PER REQUIREMENT OF THE CLIENTS.
  • INPUT FREQUENCY 48 TO 52 HZ
  • OUTPUT VOLTAGE RNGE SINGLE PHASE 230/240V +/- 1%
  • ACCURACY/REGULATION +/- 1%
  • OUTPUT FREQUENCY 50HZ
  • OUTPUT WAVEFORM TRUE TO INPUT
  • MODE OF OPERATION AUTO/MANUAL
  • VOLTAGE CORRECTION SPEED 6V TO 40 VOLTS (AS PER REQUIREMENT)
  • RESPONSE TIME LESS THAN 10M/SEC
  • CORRECTION METHOD STEP-LESS CORRECTION THROUGHT VARIABLE TRANSFORMER
  • TYPE OF COOLING ONAN
  • OPERATING TEMPERATURE 45 DEG. C ABOVE AMBIENT
  • INSULATION CLASS CLASS B TO F
  • DUTY CYCLE 100 CONTINUOUS
  • AUTO TRANSFORMER COPPER ELECTROLYTIC GRADE, HEAVY DUTY
  • BUCK BOOST TRANSFORMEMR COPPER ELECTROLYTIC GRADE, HEAVY DUTY
  • SEVO MOTOR HIGH TORQUE, QUICK RESPONSE
  • CONTOL CIRCUIT FULLY AUTOMATIC IC BASED SOLID STAT, GLASS EPOXY CONTROL CARD FOR EASY ON LINE SERICE ABILITY
  • DIGITAL CONTROL CARD DISPLAY HAVING FOLLOWING FEATURES :-  DIGITAL WITH CLASS 1 ACCURACY INPUT VOLTAGE OUTPUT VOLTAGE OUTPUT CURRENT (AUTO SCROLLING)
  • AUTO PROTECTION ALARM UNDER VOLTAGE, AUTO RESET OVER VOLTAGE, AUTO RESET SHORT CIRCUIT                
  • INDICATIONS MAINS ON UNDER VOLTAGE OVER VOLT OVER LOAD
  • LOAD APPLICATION CAPACITIVE, RESISTIVE, ANY COMBINATION OF THE LOAD
  • COMPONENT LOSSES AS PER IS : 9815
  • LOAD LOSSES AS PER IS : 9815
  • NO LOAD CURRENT AS PER IS : 9815
  • QUALITY PROSESS ISO : 9001 : 2008
  • IS STANDRAD IS : 9815, IS : 2026, IS : 335
The Single Phase Servo Voltage Stabilizer is equipped with a fully automatic IC based Solid Stat with Glass Epoxy control card for easy online service ability. The mode of operation is automatic and manual as per the need of the customers. The single phase servo voltage stabilizers price is quite affordable as per the Indian markets and has a lot many technical features. The input and the output voltage can be seen on the Digital Control Card Display and is very efficient to use. It has different Input range, from 140-280V, 170-270V, 196-265V as per the requirement of the clients and the input frequency is from 48-50Hz. The voltage correction speed is also as per the requirement from 6V to 40V with a unique response time of less than 10MSec. There is an auto protection alarm and works in Under Voltage, auto reset, Over Voltage and Short Circuit. The display indicator indicates when the Mains on, Under Voltage, Over Voltage and Overload.
View Complete Details

LINEAR SERVO STABILIZER

  • Capacity 100 KVA TO 2000 KVA
  • Type Suitable for Balanced Load & Balanced Supply
  • Application Indoor / Outdoor Type (Optional)
  • Phase 3 Phase, 4 Wires
  • Frequency 50Hz.
  • Input Voltage 300-460V, 340-460V, 360-460V (Phase to Phase)
  • Output Voltage 400V /415V ±1% (Phase to Phase)
  • Response Time Fraction of Second
  • Speed of Correction 8-16V/Sec.
  • Mode of Operation Automatic/Manual/Hand Control
  • Suitability Suitable for all Power Factors
  • Wave Form Distortion Nil
  • Duty Cycle 100% Continuous
  • Efficiency 98%
  • Cooling ONAN (Oil Natural Air Natural)
  • IS Standard IS : 2026
  • Transformer Oil IS : 335
  • Operating Temperature 0° C to 50° C above ambient
  • Lamination Used CRGO Lamination – M4 Grade
  • Copper Used 99.9% Pure Electrolytic Grade
  • Carbon Rollers Used High Grade Graphite Rollers
LT Automatic Voltage Stabilizers holds potential for units having either LT supply or low capacity HT connection. The range of Input supply for which the stabilizer is designed depends upon the voltage condition at the supply point.
View Complete Details

Amf Panel

An uninterruptible power supply (UPS) system is your bridge between mains power and your backup generators. Automatic mains failure (AMF) panels also referred to as automatic transfer switch (ATS) panels make the power switch to emergency standby generators in the event of a significant loss of mains power or total blackout. Without AMF panels, generators need to be operated manually and that can mean lost data, potential damage to electrical equipment and huge amounts of disruption.
View Complete Details

ISOLATION & ULTRA ISOLATION TRANSFORMER

  • Isolation Transformer Specifications Phase
  • Single Phase Input Voltage
  • 220 Volts Input Voltage
  • 220 Volts Transformer Ratio
  • 1:1 Power Factor
  • 0.75 Lag to lead Frequency
  • 50 Hz VI Electric strength
  • 1500 V AC for 120 sec. Insulation esistance
  • More Than 100M Ohms. Capacitance Coupling
  • 0.01 PF 100 db Common Mode attenuation
  • 100 db Class Of Insulation
Transformers also provide an extremely useful feature called isolation, which is the ability to couple one circuit to another without the use of direct wire connections. There are applications where electrical isolation is needed between two AC circuit without any transformation of voltage or current levels. In these instances, transformers called isolation transformers having 1:1 transformation ratios are used.
View Complete Details

Online UPS

  • Technical Specifications of On/Off line UPS Range
  • 1 KVA to 10 KVA, Single Phase 5 KVA to 50 KVA, Three Phase Design
  • Modular for easy servicing Tropicalized to suit any working condition  Input
  • Normal Voltage, 160 Volt (AC) to 280 Volt (AC) Single  Phase, 270 Volt (AC) to 470 Volt (AC) Three Phase Nominal Frequency
  • 45 Hz to 55 Hz DC Voltage (50 KVA & Above)  (10 KVA to 45 KVA) (1KVA to 7.5 KVA)
  • 432 Volt 360 Volt / 384 Volt  48Volt /60Volt /120Volt/180Volt DC Voltage (Optional)
Its AVR function allows Input Voltage range from 70% to 125%. It is based on micro controls and there it has fewer components and highest reliability. It has ability to take care of Overload, Over Voltage, and Battery under Voltage, Short circuit and Shut down. The LCD Digital display of UPS always keep the customer fully informed about the UPS condition.
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us