Post Buy Requirement
ST
Coimbatore, Tamil Nadu, India
Add Review

Other Products / Services #5851409

Our Complete range of products are Solar Power Solutions Integrator and Ultra Isolation Transformer Closed Model.

Micro Controller Mother Board

  • Single phase capacity 1 to 25 kva
  • Three phase (air cooled) 3 to 150 kva
  • Three Phase (oil cooled) 3 to 2000 kva
  • Input voltage range 170-270 Single phase 295-465 volts three phase 195-270 Single phase 340-465 volts three phase 205-270 single phase 360-465 volts three phase
  • Special range As per customer requirements
  • Output voltage 220/230/240 V AC in single phase 380/400/415 V AC in three phase
  • System Unbalanced/balanced type
  • Connection Star/Delta or Star/Star
  • Output Voltage regulation (+/-) 1% from no load to full load
  • Servo motor drive model -A AC Servo Synchronous Motor - Small
  • Correction speed 35 V/sec-1 ph, 60 V/sec-3 ph
  • Response time Above 60 milli. sec.
  • Servo motor model-B DC servo motor
  • Correction speed Upto 105 V/sec.
  • Response time 10 milli.sec.
  • Operating frequency 47 to 53 HZ
  • Output waveform True reproduction of input
  • Insulation Class "B"
  • Short circuit percentage and period 300 % for 250 milli sec.
  • Overload capacity 120 % for 1 minute
  • Effect of load P.F on OP Volts Nil
  • Waveform distortion Nil
  • Duty Cycle 100 % continuous
  • Ambient Upto 45c max above ambient Relative humidity upto 90%
  • System construction As per IS:9815
  • Enclosure Powder coated
  • Efficiency Better than 98% (electrical consumption saved)
  • Environment Designed for indoor / outdoor tropical use
  • Mounting On wheels
  • Earthing Earthing terminals provided

Micro controller-2016 Features:

LCD monitor is used to view of input & output voltage, Output current and freis quency.
Auto/manual output on.
Output ON adjustable time delay
Over load cut off time setting
Voltage cut off time setting
Last 30 fault events Data log view
Output voltage adjustable setting (210-245)Volt
Sensitivity and regulation adjustable
Microcontroller based Programmable Control circuits

Salient Features:
High efficiency & Fast response.Wide input voltage range & Audiable alarm for trip conditions.99.99% failure proof control circuit.No over under, shoots and hunting.Built in bypass switch upto 100 Kva.Less active component avoids failure ratings.Special electronic circuit to operate on gensets.No effect of power factor and frequency variations.Single PCB for three phase sensing and correction.Voltage at speed related to rate of fluctuations and avoids oscillations & hunting In dc motor drive.Variable speed high torque dc servo motor proportionally controls corrections.Rugged and smooth ac motor drive control through optoisolator circuit which is Highly reliable.Separate isolated PCB for triac switching for motor.

High Reliablity :
High reliability due to digital and controlling using micro controllerAll components sourcedfrom reputed manufacturers, confirm to IS/BS/VDU standardsAll raw material inspection as per internal components manualIndividual assemblies and sub assemblies tested separately.Individual assemblies tested on full load at 55 deg c in oven for 48 hours to minimize failureFinal equipment tested for accelerated life test to identify and replace any weak links.

Productions:
Input and Output Low Voltage protections.Input and Output High Voltage protections.Phase rotation/single phasing preventer.Input protection using HRC fuse.Control circuit protection using fast blow fuse.Electronic overload protection.

LCD Specifications:
16*4 lcd display is used for easy reading of parameters.True rms sensing and reading of voltage and current.100 event error log facilities for easy diagnosation of fault level.Internal variable timer is adopted for on time delay and overload trip of scvs.Selectable phase reverse function.Selectable auto on function.Less analog circuit and hence failure rate is reduced.Built in digital meter for monitoring the voltage / current & frequency.Separate isolated PCB for triac switching for motor.

View Complete Details

Online UPS

  • Input Voltage 415V+10%-20%
  • Battery Type SMF/ Tubular/ Automotive
  • Model 3 PH Input/ 3PH Output
  • Rating 5KVA200KVA
  • Input Frequency 50Hz(+/_)5%
  • Output Frequency 50Hz(+/_)1%
  • Crest Factor 3:1
  • Wave Form Sinusoidal
  • T.H.D Less than 3% on Liners Loads
  • Inverter Efficiency Better than 85%
  • DC Voltage 120 V To 384 V
  • Humidity 0-95% Non Condensing
  • Operating Temperature 0-45℃
  • Audible Noise Less Than 50dB
View Complete Details

Automatic Power Factor Control Panel

Advantages:
Reduction in maximum demandLow power factor penalty can be avoidedExtended life for shift gears, capacitors & cablesAvoid manual disruptionMicro processor based automatic controller displayWe provide solutions for improving plant power factor by installing our APFC panel

Features:
Product range : 20 KVAr to 500KVArAll major components of standard make like SLEMENS, L&T, and HAVELLSSERVOCOM Provides multiple stages, like 8, 12, 16moreBy using special designed electronic control circuit

View Complete Details

Solar Power Solutions Integrator

High Performance::
Power tolerance of to +3% provides a stable, high-energy system outputBetter performance under low light conditionMore power per unit area for cost effectiveEngineering excellence:Increased cell to frame clearance reduces the effect of soilingHigh wind/snow load tolerance (pass mechanical load test of 5400pa)

Reliability & Clarifications:
Product range : 20 KVAr to 5000KVAr25 tears limited warranty on power output5 year product warrantyIEC 61215, IEC 61730

Features:
Transformer with peak efficiency (96.0%)Isolation of primary & secondary circuitWide operating temp.ranges:-25 C to +70 CFull power up to 57 C (without de rating)Rs 485 (ELA485) communication interfacesIntelligent MPP trackingSuitable for indoor and outdoor application (Ip65)Without fan (for 2.5 to 9.9KVA models)Simple and direct on-screen dada display (for 5kVA model)

View Complete Details

Electric Transformers

Servocom Features:

Servocom Transformers are used to step up and step down the voltage for imported machinery and to eliminate all the negative transients in the electrical supply and also, to avoid the neutral wire problems, isolation transformers will be used where neutral wire is taken in the secondary usage.
Other Transformers are of Five Types:
Control transformers
Auto transformers
Step up transformers
Step down transformers
Isolation transformers

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

List of Other Products by SERVOCOM TECHNOLOGIES from Coimbatore, Tamil Nadu.
Post Buy Requirement
ST
Add Review

Other Products / Services

Our Complete range of products are Solar Power Solutions Integrator and Ultra Isolation Transformer Closed Model.

Micro Controller Mother Board

  • Single phase capacity 1 to 25 kva
  • Three phase (air cooled) 3 to 150 kva
  • Three Phase (oil cooled) 3 to 2000 kva
  • Input voltage range 170-270 Single phase 295-465 volts three phase 195-270 Single phase 340-465 volts three phase 205-270 single phase 360-465 volts three phase
  • Special range As per customer requirements
  • Output voltage 220/230/240 V AC in single phase 380/400/415 V AC in three phase
  • System Unbalanced/balanced type
  • Connection Star/Delta or Star/Star
  • Output Voltage regulation (+/-) 1% from no load to full load
  • Servo motor drive model -A AC Servo Synchronous Motor - Small
  • Correction speed 35 V/sec-1 ph, 60 V/sec-3 ph
  • Response time Above 60 milli. sec.
  • Servo motor model-B DC servo motor
  • Correction speed Upto 105 V/sec.
  • Response time 10 milli.sec.
  • Operating frequency 47 to 53 HZ
  • Output waveform True reproduction of input
  • Insulation Class "B"
  • Short circuit percentage and period 300 % for 250 milli sec.
  • Overload capacity 120 % for 1 minute
  • Effect of load P.F on OP Volts Nil
  • Waveform distortion Nil
  • Duty Cycle 100 % continuous
  • Ambient Upto 45c max above ambient Relative humidity upto 90%
  • System construction As per IS:9815
  • Enclosure Powder coated
  • Efficiency Better than 98% (electrical consumption saved)
  • Environment Designed for indoor / outdoor tropical use
  • Mounting On wheels
  • Earthing Earthing terminals provided

Micro controller-2016 Features:

LCD monitor is used to view of input & output voltage, Output current and freis quency.
Auto/manual output on.
Output ON adjustable time delay
Over load cut off time setting
Voltage cut off time setting
Last 30 fault events Data log view
Output voltage adjustable setting (210-245)Volt
Sensitivity and regulation adjustable
Microcontroller based Programmable Control circuits

Salient Features:
High efficiency & Fast response.Wide input voltage range & Audiable alarm for trip conditions.99.99% failure proof control circuit.No over under, shoots and hunting.Built in bypass switch upto 100 Kva.Less active component avoids failure ratings.Special electronic circuit to operate on gensets.No effect of power factor and frequency variations.Single PCB for three phase sensing and correction.Voltage at speed related to rate of fluctuations and avoids oscillations & hunting In dc motor drive.Variable speed high torque dc servo motor proportionally controls corrections.Rugged and smooth ac motor drive control through optoisolator circuit which is Highly reliable.Separate isolated PCB for triac switching for motor.

High Reliablity :
High reliability due to digital and controlling using micro controllerAll components sourcedfrom reputed manufacturers, confirm to IS/BS/VDU standardsAll raw material inspection as per internal components manualIndividual assemblies and sub assemblies tested separately.Individual assemblies tested on full load at 55 deg c in oven for 48 hours to minimize failureFinal equipment tested for accelerated life test to identify and replace any weak links.

Productions:
Input and Output Low Voltage protections.Input and Output High Voltage protections.Phase rotation/single phasing preventer.Input protection using HRC fuse.Control circuit protection using fast blow fuse.Electronic overload protection.

LCD Specifications:
16*4 lcd display is used for easy reading of parameters.True rms sensing and reading of voltage and current.100 event error log facilities for easy diagnosation of fault level.Internal variable timer is adopted for on time delay and overload trip of scvs.Selectable phase reverse function.Selectable auto on function.Less analog circuit and hence failure rate is reduced.Built in digital meter for monitoring the voltage / current & frequency.Separate isolated PCB for triac switching for motor.

View Complete Details

Online UPS

  • Input Voltage 415V+10%-20%
  • Battery Type SMF/ Tubular/ Automotive
  • Model 3 PH Input/ 3PH Output
  • Rating 5KVA200KVA
  • Input Frequency 50Hz(+/_)5%
  • Output Frequency 50Hz(+/_)1%
  • Crest Factor 3:1
  • Wave Form Sinusoidal
  • T.H.D Less than 3% on Liners Loads
  • Inverter Efficiency Better than 85%
  • DC Voltage 120 V To 384 V
  • Humidity 0-95% Non Condensing
  • Operating Temperature 0-45℃
  • Audible Noise Less Than 50dB
View Complete Details

Automatic Power Factor Control Panel

Advantages:
Reduction in maximum demandLow power factor penalty can be avoidedExtended life for shift gears, capacitors & cablesAvoid manual disruptionMicro processor based automatic controller displayWe provide solutions for improving plant power factor by installing our APFC panel

Features:
Product range : 20 KVAr to 500KVArAll major components of standard make like SLEMENS, L&T, and HAVELLSSERVOCOM Provides multiple stages, like 8, 12, 16moreBy using special designed electronic control circuit

View Complete Details

Solar Power Solutions Integrator

High Performance::
Power tolerance of to +3% provides a stable, high-energy system outputBetter performance under low light conditionMore power per unit area for cost effectiveEngineering excellence:Increased cell to frame clearance reduces the effect of soilingHigh wind/snow load tolerance (pass mechanical load test of 5400pa)

Reliability & Clarifications:
Product range : 20 KVAr to 5000KVAr25 tears limited warranty on power output5 year product warrantyIEC 61215, IEC 61730

Features:
Transformer with peak efficiency (96.0%)Isolation of primary & secondary circuitWide operating temp.ranges:-25 C to +70 CFull power up to 57 C (without de rating)Rs 485 (ELA485) communication interfacesIntelligent MPP trackingSuitable for indoor and outdoor application (Ip65)Without fan (for 2.5 to 9.9KVA models)Simple and direct on-screen dada display (for 5kVA model)

View Complete Details

Electric Transformers

Servocom Features:

Servocom Transformers are used to step up and step down the voltage for imported machinery and to eliminate all the negative transients in the electrical supply and also, to avoid the neutral wire problems, isolation transformers will be used where neutral wire is taken in the secondary usage.
Other Transformers are of Five Types:
Control transformers
Auto transformers
Step up transformers
Step down transformers
Isolation transformers

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us