1 Products availableServo Voltage Stabilizer is commonly observed that, AC main supply is never 230 Volt or 415 Volt, but varies from 150 Volt - 300 volt and 300 Volt - 500 Volt. The difficulties caused by them are well known, such as Over Load Condition, Line Losses, Poor Power Factor and several other reasons. Generally constant voltage which is required to load is never constant, but in fluctuation manner. It is observed that during the daytime, the voltage is quiet low and during the night the Voltage is high then the normal.
This fluctuation in supply system results frequent breakdown, low production and also loss of energy. The performance of any electrical equipment is optimum at its rated voltage. Both over / under voltages are harmful for the system. The under voltage reduces efficiency whereas the over voltage shortens the life.
The power agencies insist the consumer to fix the capacitor to improve power factor to get better results in power saving. But Voltage is far more important factor to save the power loss.
In case of very Low / High voltages, the telecom systems are powered by DG sets. Our Line Conditioner Unit meets the requirement of input voltage variation from 110V - 280V (Single phase) and 300V - 500V (Three phase). 240V - 500V is also available on demand.
In India, there are large voltage variations in the mains power supply. To overcome this problem, we are offering Line Conditioner Unit.
Servo Stabilizers are automatic line Voltage corrector using synchronous motor in close loop control. The stabilizer employ continuously variable auto transformer, buck-boost transformer, AC synchronous motor, state of the art IC closed loop control system with all protection, metering, indication and control system to give desired output voltage within the specified limits for a range of input voltages. Provision for manual correction of voltage can also be provided.
S.NO. | PARAMETER | SINGLE PHASEUNIT | THREE PHASE UNIT |
---|---|---|---|
1 | Rating | 2 KVA to 50 KVA | 6 KVA to 2000 KVA |
2 | Input Voltage Range | a) 180V - 280V b) 160V - 280V c) 140V - 280V |
a) 350V - 470V b) 340V - 470V c) 320V - 470V d) 300V - 480V e) 270V - 480V f) 240V - 480V |
3 | Nominal Output Voltage | 230V | 400V |
4 | Output Voltage Accuracy | ± 1% | ± 1% |
5 | LineFrequency Variation | 47Hz-53Hz . | 47Hz-53Hz |
6 | Effect of Power Factor | None | None |
7 | Wave Form Distortion | None added | None added |
8 | Control | Digital/Analogue | Digital/ Analogue |
9 | Response Time | 10 ms. | 10m s. |
10 | Voltage Correction Rate 1. Air Cooled 2 Oil Cooled |
25V / Sec. 15V/ Sec |
40V / Sec 25V / Sec. |
11 | LCD Display (20 x 2 matrix) | Date & Time, Input Voltage, Output Voltage & Current | |
12 | Log book Memory (Non-volatile) |
|
|
13 | Programmable Features(Through 2-parallel way resettable passwords) | 1. HV cut-off set 2. LV cut-off set. 3. O/L trip set 4. Time delay set 5. Operating mode (auto/manual) |
|
14 | Cooling: 1. Air Cooled 2. Oil Cooled |
2 KVA to 40 KVA & above 5 KVA to 1000 KVA & above |
|
15 | Efficiency | 97% | |
16 | Protection | a) Automatic Switch-Off against: b) Under / Over-Voltage c) Over-Load & Short - Circuit d) Single Phasing |
|
17 | Surge Protection | Class C Type Secondary surge Protection |
Power is your Business Life Line. The more you have the better for your business growth and productivity and losing it may prove disastrous for your business. So, for uninterrupted power security and performance preserve it with online ups system. Our goal of zero defects and total customer satisfaction makes us the preferred supplier for many major companies in the electronics and information industries. At, our quality is measured by our products.
Our sophisticated technology has enable us to cater to varied needs of power distribution and backups, we provides a complete line of power electronics products. These include Online UPS up to 4000kva, battery chargers, Solar UPS System, Servo Stabilizer, Solar Inverters.
Moreover our vast industry experience and our presence have enabled us to offer our technologically advanced power solutions as per the requirements of our customer .As we lay considerable efforts to study the requirements and provide solution through continuously upgraded product by our continual research and development so as to offer our client.
Our UPS is fully Digital adopting a Signal Processing Unit that integrated all power stages as well as control functions. The system uses only 2 cards as compared to a large number of control cards used in conventional UPS Systems. Single Processing unit increases system through increases reliability.
TECHNICAL SPECIFICATIONS OF ON/OFF LINE UPS | |
---|---|
Range | 1 KVA to 10 KVA, Single Phase 5 KVA to 50 KVA, Three Phase |
Design | Modular for easy servicing Tropicalized to suit any working condition |
Input | Normal Voltage, 160 Volt (AC) to 280 Volt (AC) Single Phase, 270 Volt (AC) to 470 Volt (AC) Three Phase |
Nominal Frequency | 45 Hz to 55 Hz |
DC Voltage |
432 Volt 360 Volt / 384 Volt 48Volt /60Volt /120Volt/180Volt |
DC Voltage (Optional) | As per customer's requirement |
Output (Technology) | IGBT |
Output Voltage | 230Volts AC (Single Phase) 400/415 Volts AC (Three Phase) |
Voltage Regulation | +/-1% for DC I/P variation & O/P load variation 50Hz +/- 0.05Hz 50Hz +/- 0.05Hz Any optional frequency |
Wave Form | Pure Sine Wave |
Power Factor | 0.8 lagging to unity |
Harmonic Distortion | Less than 3% |
Inverter Efficiency | 93% for 360V DC and above 90% for 180V DC 85% for 48V DC/ 60V DC/ 72V DC/ 120V DC |
Crest Factor | 3:1 |
Overload | 125% for 5 Minutes 150% for 60 Sec |
Transient Recovery | Within 20 m sec ( 1 cycle) |
Phase Displacement | 1200 +/- 1o (For 3 Phase output) |
Audible Noise | Less than 45 Db ant 1 Meter |
Metering | Output Voltage, Analog/Digital (Optional) (As per customer choice) LED & Microprocessor based Digital LCD metering for multiple parameters shall be provided as optional in Higher Capacities. |
General Operation Temperature | 0oC to 50oC |
Humidity | Max 95%, Non-condensing |
Degree of Protection | IP 42 |
Protection (DC Under Voltage) (DC Over Voltage) (Output Under Voltage) (Output Over Voltage) (Output Over Load) (Output Short-circuit) |
Inverter Trips Inverter & Charger Trips Inverter Trips Inverter Trips Inverter Trips Inverter Trips |
Indication & Alarms | Mains On by Indicator Inverter On by Indicator |
(Mains Fall) (DC Low) (DC Over Voltage) (Output Under Voltage) (Output Over Voltage) (Output Overload) |
Indicator & Alarm Indicator & Alarm Indicator & Alarm Indicator & Alarm Indicator & Alarm Indicator & Alarm |
By Pass Facility (Static Bypass Switch) |
Manual Bypass Switch (Provided as Standard feature) Bi-directional (Optional) |
Isolation of Power (Input) (Output) (Battery) |
MCB Provided Switch / MCB (Optional) HRC fuse / MCB (Optional) |
Battery Bank (Capacity) |
Sufficient to sustain full for 10 min to 10 Hrs. or Any backup time required |
Type of Battery | SMF (Sealed Maintenance Free) or Tubular Stationary Lead-Acid Battery |
Accessories | Set of inter row & inter bank connectors with battery Battery mounting Rack (Optional) |
Application | Servers, Computer work stations, Network equipments. Telecom & Cellular equipments. Automatic Teller machines. Medical equipments, Fire protection equipments. Special Purpose machines.. |
UPS ON LINE IGBT HIGH FREQUENCYUPS | |
OVERVIEW:- | |
Its AVR function allows Input Voltage range from 70% to 125%. It is based on micro controls and there it has fewer components and highest reliability. It has ability to take care of Overload, Over Voltage, and Battery under Voltage, Short circuit and Shut down. The LCD / Digital display of UPS always keep the customer fully informed about the UPS condition. |
Transformers also provide an extremely useful feature called isolation, which is the ability to couple one circuit to another without the use of direct wire connections. There are applications where electrical isolation is needed between two AC circuits without any transformation of voltage or current levels. In these instances, transformers called isolation transformers having 1:1 transformation ratios are used.
Our Isolation Transformers isolate the equipments from noisy power line hence providing a better option to clients. These remove power line noise, surges, spikes and transients. It also provides high insulation resistance and provides complete electromagnetic and electrostatic shielding.
Our range of Isolation Transformers is designed as per the international standards which give an assurance to the customer on the high quality of the product. An isolation transformer does not have a direct electrical path from the power input side to the power output side. The term is also used to define how much electrical isolation exists between the input and output windings. For example when using line-voltage input transformers to power low voltage device handled by humans, a high degree of isolation is required for safety. Isolated transformers often use separate bobbins for the primary and secondary coil windings, but usually the windings are just wound on top of each other with insulation in between. There is usually an electrostatic shield between windings which is tied to transformer case.
SL NO. | PHASE | SINGLE PHASE |
---|---|---|
1. | Input Voltage | 220 Volts |
2. | Output Voltage | 220 Volts |
3. | Transformer Ratio | 1:1 |
4. | Power Factor | 0.75 Lag to lead |
5. | Frequency | 50 Hz |
6. | VI Electric strength | 1500 V AC for 120 sec. |
7. | Insulation esistance | More Than 100M Ohms. |
8. | Capacitance Coupling | 0.01 PF 100 db |
9. | Common Mode attenuation | 100 db |
10. | Class Of Insulation | Class 'F' |
11. | Losses | 5% |
12. | Ambient emperature | 0-50o C |
13. | Duty Cycle | Continuous |
14. | Lamination | Cargo |
15. | Construction | as per IS :2026 |
We have marked a distinct position in the market by offering superior quality Electrical Control Panel. The offered control panel is manufactured using the best quality components and ultra-modern technology in sync with industry norms. Provided control panel is available in variegated designs, sizes and shapes as per the needs of our clients. Apart from this, clients can avail this control panel from us at market leading prices.
FEATURES :We offer high quality Step Down Transformers. It is hard wired, durable with a heavy duty chord. It has a 100 Watt maximum capacity and can be used continuously over a period of time. It has one grounded outlet in front of unit (accepts 3 or 2 prong US and Euro plugs) and reduces the voltage to the fit the next level of desired use. Perhaps it will go to some point in a factory, shop, home or even the much smaller applications and be reduced again to fit a lower voltage piece of equipment.
Step Down Transformers have a primary winding of higher number of turns than the secondary winding. Since power is fixed, lowered voltage results in increased amperage; the lowering of voltage is inversely proportional and results in increase of amperage. Our Step Down Transformers are relatively simple in design and they have the exact ratio of windings in each circuit so as to deliver the appropriate current and voltage. Application, budget and other factors must be considered before installing a particular transformer. Both incoming and outgoing voltages must be known prior to selecting any Step Down Transformer.
We offer all our products as per ISI specifications which give an assurance to the customer on the quality of our product. We are equipped with an R&D unit and testing tools and section which has got all tools and testing facilities that support us in supplying products as per clients specific requirement.
We supply a gamut of Buck-Boost Transformer that is widely used in Servo Stabilizers and can be customized as per the specific requirements of our clients. These boost transformers are made in compliance of necessary standards. Some of boost transformers features are:
Buck Boost devices are used to make small adjustments to incoming voltages such as lighting applications.
We offer high grade buck-boost converter coils, which are manufactured using excellent quality materials to last for a long period of time. We pack these buck-boost converter coils in appropriate packaging for their safe delivery to our clients. Our dexterity lies in developing them as per the specifications of our clients.
Industrial Battery Chargers Sen Pandit Stabilizerhas been a valued supplier to couple of customers for their customized requirement on Industrial Battery Chargers in India. These Industrial Battery Chargers are being used along with couple of Equipments which require DC voltage to run them and once Batteries get discharged the same needs to be brought back to station for Charging and restage. It has been designed CVCC (Constant Voltage Constant Current Chargers ) for such applications wherein customer can use Sealed Batteries Also and enjoy the luxury of using product with best of the life from Batteries.
Sen Pandit StabilizerBattery chargers can also be used for UPS applications where in majorly all Multinational UPS manufacturers Have 4 amps chargers for sizing up to 10KVA UPS systems. Customers who look for larger backups need additional Charger to charge batteries which becomes a big issue for End customers. We have ensured that customers can feel Comfortable technically by adding additional charger along with their UPS and procure batteries of higher capacities too now.
TECHNICAL FEATURES:
Sen Pandit Stabilizeroffers a finest range of solar panels / modules in mono/ multi crystalline and thin film modules of all types and sizes. We ensure fabricating these products as per the requisites of customers, and design and engineer the products with high precision so as to derive exact final output.
We have advanced facility and equipments for production of panel and modules and each and every panel goes through stringent testing so that outstanding final product is derived. We make these solar panels/solar modules available at leading and competitive rates for our customers.
Solar Energy in India represents one of the Biggest Opportunities in the Energy Sector. The Government has recognized Indias massive potential in Solar Energy and has planned a huge subsidy scheme through the Jawaharlal Nehru National Solar Mission (JNNSM).While currently the Support is mainly targeted towards big commercial plants, its only a matter of time before distributed residential systems become widespread. Some states like Gujarat and Rajasthan are also independently supporting solar energy through subsidies and grants.