Our Products
Our product range contains a wide range of high Pressure Valves, pressure valve, MANIFOLD VALVES : SERIES - MFV2 (Two Way), bleed valve and MONOFLANGE VALVES : SERIES - FMV
FEATURES
Available in SS316, NACE certified on requestHeat Code Traceable to certified material test reportLow operating torquesPTFE packing standard, Graphite packing for hightemperature on requestAvailable with 2 way, 3 way and 5 way valve.Available with Pipe to Pipe, Pipe to Flange, Flange toFlange, Remote, Remote mounting Base vent, Base, Direct and Integral mounting.Convenient method of blocking, bleeding and calibratingpressure instruments.Designed for connection system impulse line & transferCombine the function of a tee, calibration valve, isolationvalve, all tubing and fittings in a sigle valve configuration.Standard port sizes up to 1/2NPT/BSP/BSPTEvery valve is factory tested
OPERATING PARAMETERS
Pressure Rating : upto 6000 psig (408 bar) at CWP
Temperature Rating : -54C to 232C with PTFE packing
: upto 426C with optional graphite packing
TESTING
Standard Test : Each Valve is factory tested with nitrogen at 1000 psig (69 bar) for leakage at the seat andpacking, the maximum allowable leak rate of 0.1 sccm
Optional Hydrostatic test : This test is performed with de-ionised water at 1.5 time the working pressure.
APPLICATIONS
General Plant Service
Pressure Instrumentation devices
Differential pressure Instrumentation devices
Pressure equalization
Block and bleed applications
Venting
Description |
Features and Benefits |
1. Bar Handle |
To operate and control the valve flow. |
2. Set Screw |
Lock the handle with stem. |
3. Stem |
i) Rolled and silver plated stem threads for excellent performance and extended service life. ii) Burnished stem at packing area to ensure low torque operation of the valve & reduction in packing wear |
4. Stem Tip |
17‐4 PH Stainless Steel hardened non rotational self centering stem tip for superior and repeatable positive bubble tight shut off. |
5. Packing Adjuster |
Makes external adjustment to set the perfect sealing of gland packing. |
6. Lock Nut |
For safety to prevent accidental valve disassembly. |
7. Bonnet |
Directly screwed to the main body. |
8. Packing |
Packing below the threads protects the flow stream from lubricant contamination on the threads or wash out and also protect the stem threads from potential damaging effects of the media. |
9. Washer |
For sealing between body and bonnet assembly. |
10. Locking Pin |
To prevent accidental loosening / disassembly of valve. |
11. Dust Cap |
Protects the stem from foreign particles. |
FEATURES
Available with OS & Y bolted bonnet, integral screwed bonnet and bolted bonnet design.
ANSI B16.5 Flanged Inlet Connections 1/2" to 2" Sizes.
Class 150 rated to Class 2500 rated.
API Flanged Inlet Connections also available.
1/2" - 14 NPT (Female) Standard Outlet.
1/4" x 18 NPT (Female) Standard Vent.
Standard Material of construction: SS316 / SS316L, CarbonSteel and Duplex.
Fire Safe designed to meet BS 6755 Part 2/API 607 areavailable on request.
Material Traceability to EN10204 3.1.B (Body only).
Anti Blow-Out stem & low operating torque.
Bubble tight shut off seats 17-4 PH tips standard.
PTFE is a standard Valves Packing, Graphite is also availableon request.
Every Valve is Factory Tested.
OPERATING PARAMETERS
Pressure Rating : Class 150 to Class 2500 in accordance with ASME B16.5.
Temperature Rating : Up to 204C with PTFE Packing.
Up to 428C with Graphite Packing.
APPLICATIONS
Double block & bleed instrument isolation.
Gauge isolation, Instrument drain.
Chemical injection connection, Sampleconnection.
Chemical seal instrument isolation.
Piping / instrument interface.
Direct mounting of instruments.
Remote mounting of instruments.
FEATURES
Available in SS316, NACE certified on requestHeat Code Traceable to certified material test reportLow operating torquesPTFE packing standard, Graphite packing for hightemperature on requestAvailable with 2 way, 3 way and 5 way valve.Available with Pipe to Pipe, Pipe to Flange, Flange toFlange, Remote, Remote mounting Base vent, Base, Direct and Integral mounting.Convenient method of blocking, bleeding and calibratingpressure instruments.Designed for connection system impulse line & transferCombine the function of a tee, calibration valve, isolationvalve, all tubing and fittings in a sigle valve configuration.Standard port sizes up to 1/2NPT/BSP/BSPTEvery valve is factory tested
OPERATING PARAMETERS
Pressure Rating : upto 6000 psig (408 bar) at CWP
Temperature Rating : -54C to 232C with PTFE packing
: upto 428C with optional graphite packing
TESTING
Standard Test : Each Valve is factory tested with nitrogen at 1000 psig (69 bar) for leakage at the seat andpacking, the maximum allowable leak rate of 0.1 sccm
Optional Hydrostatic test : This test is performed with de-ionised water at 1.5 time the working pressure.
APPLICATIONS
Pressure and Differential pressure Instrumentations
Description |
Features and Benefits |
1. Bar Handle |
To operate and control the valve flow. |
2. Set Screw |
Lock the handle with stem. |
3. Stem |
i) Rolled and silver plated stem threads for excellent performance and extended service life. ii) Burnished stem at packing area to ensure low torque operation of the valve & reduction in packing wear |
4. Stem Tip |
17‐4 PH Stainless Steel hardened non rotational self centering stem tip for superior and repeatable positive bubble tight shut off. |
5. Packing Adjuster |
Makes external adjustment to set the perfect sealing of gland packing. |
6. Lock Nut |
For safety to prevent accidental valve disassembly. |
7. Bonnet |
Directly screwed to the main body. |
8. Packing |
Packing below the threads protects the flow stream from lubricant contamination on the threads or wash out and also protect the stem threads from potential damaging effects of the media. |
9. Washer |
For sealing between body and bonnet assembly. |
10. Locking Pin |
To prevent accidental loosening / disassembly of valve. |
11. Dust Cap |
Protects the stem from foreign particles. |
FEATURES
Available in SS316 all wetted parts in accordance with NACE MR01-75
Heat Code Traceable to certified material test report
Rugged and compact design
Quick opening and closing
Straight and angle flow Patterns
Panel mountable
Flow coefficient (Cv) from 0.11 to 0.70
Orifice sizes : 0.080" (2mm), 0.125" (3.2mm), 0.250" (6.4mm)
Variety of end configurations includes SEALEXCEL
Well-Lok Tube Fittings, Male/Female NPT, BSPT and BSPP
pipe connection.
Every valve is factory tested
OPERATING PARAMETERS
Pressure Rating : upto 3000 psig (206 bar) at CWP
Temperature Rating : -28C to 93C
FEATURES
Available in SS316L
Heat Code Traceable to certified material test report
Compact and convenient installation
Vent tube design prevents accidental removal of the stem
Vent tube directs excess liquid or gas from system line
Flow coefficient (Cv) 0.25
Orifice size 0.125" (3.20mm)
Variety of end configurations includes SEALEXCEL
Well-Lok Tube Fittings, Male/Female NPT, and SAE pipe
connection
Every valve is factory tested
OPERATING PARAMETERS
Pressure Rating : upto 10000 psig (689 bar) at CWP
Temperature Rating : -54C to 454C
FEATURES
ANSI B16.5 Flanged Inlet Connections 1/2" to 2" Sizes.
Class 150 rated to Class 2500 rated.
API Flanged Inlet Connections also available.
10 mm and 15 mm Full bore Valve design.
1/2" - 14 NPT (Female) Standard Outlet.
1/4" x 18 NPT (Female) Standard Vent, 1/2" x 14 NPT
(Female) optional vent.
Standard Material of construction: SS316 / SS316L, Carbon
Steel and Duplex.
Fire Safe designed to meet BS 6755 Part 2/API 607 are
available on request.
Material Traceability to EN10204 3.1.B (Body only).
Anti Blow-Out stem & low operating torque.
Valves are available with Packing, PTFE, PEEK or Graphite.
Bubble tight shut off.
Every Valve is Factory Tested
OPERATING PARAMETERS
Pressure Rating : Class 150 to Class 2500 in
accordance with ASME B16.5.
Temperature Rating : Up to 204C.
APPLICATIONS
Double block & bleed instrument isolation.
Gauge isolation, Instrument drain.
Chemical injection connection, Sample connection.
Chemical seal instrument isolation.
Piping / instrument interface.
Direct mounting of instruments.
Remote mounting of instruments.