Our Products
Level Transmitters
2 Products availableIndustrial & Engineering Products
2 Products availableFlow Meters
1 Products availableFilters
1 Products availableCalibrators And Monitoring Systems
1 Products availablePressure Switches
1 Products availableWe offer a complete product range of Full View Glass with Tri-clover connection
The Scientific Hydrostatic Level Indicator is a robust diaphragm type gauge with a dial read out. It is designed for easy on site adjustment to take account of varying liquid density.
This gauge requires no power source and is suitable for fitting to tanks, which may be used for different liquids where the specific gravity may change. These externally mounted version is suitable for general application, though it is particularly suitable for marine applications.
SDSPLT static pressure level indicator transmitter assembled with advanced pressure sensor and double layers cable which are our original creation with wear resistant and water proof featutes can meet the demands of various extreme service conditions. Full welding stainless steel armored tube structure ensures the measurement in the corrosive liquids.The measured medium can be water, oil, acid, alkali or viscous liquid.Advanced in technology, precise in measure, reliable in quality, easy in installation, SDSPLT transmitter is an ideal and economical level instrument for process measure and control system.
SDSPLT level indicator transmitter is tailored for liquid sulfur and high temperature naphthol and combined with previous international application experiences. This product with stainless steel armored welding cable and adopted with special high temperature large diaphragm sensor can be used to measure high temperature nd strong viscosity medium and can solve other measuring difficulties process industry.
Ultrasonic level meter is manufactured byScientific Devices, absorbed many kinds of level meter advantage, achieve full digital, humanized design concept, now become our last update and high end products, use cast aluminium and waterproof housing, use international common appliance connector, with standard wire connector, easy to install and with waterproof sealing cover, has perfect liquid level monitoring measuring, data transfer and human-machine communication features, use big display for the operation manu, can recode ten interrerence echo point, use import industrial class single chip, digital temperature compensation and use about ten relatived specific IC ship with wide input voltage.
With a strong anti-interference, can be set for the upper and lower liquid level limitation and output adjust, also with on site display, selectable analog, switch and RS485 output, at the same time support RS485 (Modbus) serial mode debug menu, to make up for the lack of display function, convenient interface and related facilities, also intelligent software design, for make up to no display, also can use external adjustment resistor to set internal parameters. Easy to connect with the relative facility, no need to connect with industrial media to meet most of the level measurement requirements, accordingly , it can completely solve the blockage, leakage, corrosion, maintenance inconvenience shortcomings from the traditional measurement of pressure, capacitive, float type winding.
Applications
Water and water meter treatment Pumping stations, collection wells, biochemical reactions pool, settling ponds Electricity, mining Mortar Pool, coal slurry pond, water treatment.
Range | : | 0.3 – 5 M, 0.3 – 8 M, 0.5 -10M, 0.7 – 20 M, 1 – 30 M |
Blind Spot | : | <0.3 M |
Sensor | : | ABS |
Enclosure | : | IP 65 |
Process Connection | : | 1½ ” BSP (M)/ Flanged |
Launch Angle | : | 12° Minimum |
Power Supply | : | 24 VDC |
Level Display | : | 4 Digit LCD |
Temperature | : | -10 ° C to 75° C |
Accuracy | : | ± 0.3 % |
Scientific Devices Averaging Pitot Tube is a primary flow measuring element based on the principal of measurement of differential pressure across the high & low pressure port. The differential pressure created due to the obstruction of Pitot Tube inserted from the top in the main stream of the fluid flow through the pipe line.
Specification
* | Multiport averaging for light rate of accuracy. |
* | Repeatibility of reading upto 0.1% + |
* | High flow rate turndown ration |
* | Low permanent pressure loss. |
* | Suitable for liquid, Gas & Steam flow application. |
* | Available in various material like SS316, SS316/SS304, SS304L etc. |
* | Compatible for a wide range of fluid. |
* | For large pipeline economical as compare to other type of differential pressure measurement flow meter. |
This complete assembly comprises a D.P. Transmitter for 4-20mA analog output & an averaging pitot tube assembly as a primary flow sensing elements.
A most reliable & economical instrument for low measurement of Gas, Liquid & Steam application:
Specification
* | Choice of linear or square root output. |
* | A/D or D/A converter not required as the electronic unit can be directly hooked up with the control system. |
* | Piezo resistive sensor for temperature & pressure compensation. |
* | Programmable engineering units for display |
A Flow switch is normally a simple device that monitors flow and sends a trip signal to another device such as a Pump to protect it. Flow switches are used for Pump protection, Cooling Circuit protection, high & low flow rate alarm and general flow monitoring.
32
Fluid | : | Clear Liquids & Gases |
Density / Sp. Gravity | : | Up to 2.95 |
Viscosity | : | Up to 20 cp |
Design Temperature | : | Up to 160°c |
Design Pressure | : | Up to 7 Kg/cm² |
Range | : | 2.2 to 800 M³/hr of Water /Liquid 0.1 to 300 Nm³/hr of Air/Gas at NTP |
Line Size | : | 25 NB to 150 NB |
Available Materials | : | Brass/SS316 |
Connection | : | 1” BSP (M)/1″ NTP (M) |
Accuracy | : | ±1% of FSD |
It is an instrument used to measure instant flow rate of Liquids and Gases. It is installed in the pipe line vertically upward with flanged or screwed connection.
Fluid | : | Liquids & Gases |
Density / Sp. Gravity | : | Up to 2.95 |
Viscosity | : | Up to 200 cp |
Design Temperature | : | Up to 150°C |
Design Pressure | : | Up to 15 Kg/cm² Depending on Model |
Measuring Range | : | 2.5 to 40,000 LPH of Water/Liquid & 0.1 to 750 Nm³/hr of Air/Gas at NTP |
Line Size | : | Up to 4″ NB |
Available Materials | : | MS/CS/SS304/SS304L/SS316/SS316L/PTFE lined MS or SS |
Connection | : | Flanged to ASA/BS/DIN/ Triclover Standard Screwed to BSP/NPT(M/F) |
Accuracy | : | ±2% of FSD & ±1.5% on request |
It is an instrument used to measure instant flow rate of Liquids and Gases. Can be used for metering of translucent/opaque fluids under high operating pressure and temperature.
Fluid | : | Liquids & Gases |
Density / Sp. Gravity | : | Up to 2.95 |
Viscosity | : | Up to 200 cp |
Design Temperature | : | Up to 150°C |
Design Pressure | : | Up to 25 Kg/cm² |
Measuring Range | : | 100 to 40,000 LPH of Water/Liquid 3.3 to 1400 Nm³/hr of Air/Gas at NTP |
Line Size | : | Up to 4″ NB |
Available Materials | : | SS304/SS304L/SS316/SS316L/PTFE lined on SS |
Connection | : | Flanged to ASA/BS/DIN/ Triclover Standard Screwed to BSP/NPT(M/F) |
Accuracy | : | ±2% of FSD & ±1.5% on request |
Enclosure | : | Weather proof, IP-65 / Flame Proof |