1 Services availableOur product range contains a wide range of ETAP Based System Stability Grid Stability Study for Cogeneration Projects, ETAP Based Short Circuit Analysis, ETAP Based Compliance Study for Certain Electrical Standards, ETAP Based Relay Coordination Study and ETAP Based Load Flow Study & Distribution Loss Assessment Service
Service offering provided to plants having large Internal Electrical network or having Co-generation to understand the impact of electrical disturbances on internal distribution as well as on Grid. To identify the causes of these disturbances & solutions to ensure trouble free generation & supply of power.
The offering involves visit of Electrical Expert and data collection from site on various load conditions of the facility. The collected data is then used to conduct Load flow study for various load conditions & then short circuit Analysis is conducted to generate report as per load.
Reality check of existing short circuit protection system. Short circuit & Fault Current ratings at HT, LT, PCC & MCC levels are calculated by the system precisely.Short circuit protection can be redesigned as per findings. Enhancement of facility uptime by ensuring fault is isolated by the nearest protection.
The offering involves Site Electrical data collection & running various simulation modules to check compliance to standards mentioned CEA 2010, Electricity Act (GOM/ GOI), IS 732, IS 3043, IS 60909, IS 62305, IEEE 1584 (2018), NFPA 70E, IEEE 519 (1992/ 2014)
The offering involves visit of Electrical Expert and collection of switch gear & actual relay settings and electrical data using Analysers from site on various load conditions. The collected data of switchgear & protection relay settings is the facility is fed to conduct Load flow study followed by short circuit analysis & Protection Relay coordination study.
The offering requires collecting Electrical infrastructure details and Electrical data collection using Power Quality Analysers by team of experienced Engineers. The collected data is then simulated in ETAP for conducting validation & load flow study. This service provides exact quantum of Loss with load & branch losses. Component wise loss can be identified viz. X’mer/ Cables. Solutions pertaining to correction & loss reduction can be designed & implemented to reduce losses