Our Product / Services
Electronic Timers
2 Products availableMeasuring Instruments & Equipment
2 Products availableLimit Controller
2 Products availableProcess Control Equipment
2 Services availableIndustrial Chemicals
1 Products availableThe pH 600 - 1 series of pH Controller and Transmitter provides a reliable method of Monitoring, Controlling & Transmitting 4 - 20mA / RS 485 MODBUS RTU communication for Interfacing to PLC, Data logger, HMI, etc., . This product is suitable to measure pH in water treatment, Electrolytic water cleaning, Chemical Industries, Food Process, Waste Water treatment, Textile Industries & Neutralization process, etc., . This pH Controller & Transmitter can Measured using Industrial Combined pH Sensors, Temperature can be measured using temperature sensor.
Features :
Specifications :
The TDS 602 - 1 series of TDS Controller and Transmitter provides a reliable method of Monitoring, Controlling & Transmitting 4 - 20mA / RS 485 MODBUS RTU Communication for Interfacing to PLC & Data logger. This product is suitable to measure TDS in water treatment, Electrolytic water cleaning, Chemical Industries, Food Process, Waste Water treatment, Textile Industries & Neutralization process, etc., . This TDS Controller & Transmitter can Measured using Industrial TDS Sensors, Temperature can be measured using temperature sensor.
Features :
Specification :
Features :
Specification :
SANSEL Model HCAL 1104U – v2 Humidity and Temperature Generator is to perform a rapid & easy calibration of portable instruments, sensors, Transmitter and data logger of different manufacturers. Solid state Heating & Cooling technology with high performance humidification system, generate precision chamber stability & uniformity gradient range from 5 to 60°C(Temp.) / 5 to 95 % RH*(Humd.) / -25 to 40°C(Dew point)
Features
Accessories
Optional
Specifications
Model | HCAL 1104U – v2 |
---|---|
Control Range | Temperature : 5 to 60°C / Humidity : 5 to 95 % RH @ 25°C/ Dew point : -25 to 40°C (psychometric Converted Dew point) |
Resolution | 0.01 °C / %RH |
Stability | Better than ± 0.05 °C / 0.2 % @ 25°C |
Uniformity | ± 0.2 °C / 0.3 % RH @ 25°C |
Display | 7” True colour TFT LCD Display with Touch screen |
Test sensor insert port | Inter changeable Acrylic door Provided on front side of the chamber with pg21 gland (cable or sensor size range from 13 to 18mm) x 3nos |
External Humidifier Water tank capacity |
6 liters (approx.) (NOTE : 3 liter filling is enough for our application) |
Humidifier Liquid | Distilled water |
Humidifying Time | 2 %RH / sec (50 to 90 % RH) |
Dehumidifying Time | 6 %RH / sec (50 to 10 % RH) |
Test chamber area | 230mm DIA x 170mm Depth (Approx) |
Power supply | 230V AC ± 10% / 50Hz (Optional 110V AC) |
Power Consumption | 1000 VA |
Construction | Inner chamber SS 310 / outer MS powder coating |
Overall Dimension | 436mm L x 676mm W x 368mm H (Approx) |
Instrument Weight | 44 kg(without Accessories) + 6 kg (standard accessories) (Approx.) |
A large number of salts such as carbonates, bicarbonates, chloride, sulphates, phosphates & nitrates of calcium, magnesium, sodium, potassium, iron and manganese etc., are found dissolved in natural water. Similarly coastal marine water contains substantial quantity of these salts. A high content of dissolved solids elevates the density of water, influences Osmoregulation of fresh water organism and reduces solubility of gases thereby reducing the utility of water for drinking, irrigation and industrial purposes. Therefore, determination of Total Dissolved solids is one of the important parameters in water analysis. SANSEL make digital TDS meter TDS 100 is extremely useful for fast and accurate determination of Total Dissolved Solids in a liquid. The use of solid state technology and IC circuitry makes this instrument versatile and reliable. The multi position selector switch quickly sets the digital display to the desired test range. The instrument is ideal for testing of natural water, drinking water, waste water, brine solution, sea water and soluble salts, etc.,
Features :
Accessories :
Optional
Specifications
Model | TDS 100 |
---|---|
Range | 0 – 20 ppm/ 200 ppm/ 2000 ppm/ 20ppt / 200ppt ( 5 range selection using front rotary switch ) |
Resolution | 0.01 / 0.1 / 1 for ppm & 0.01 / 0.1 for ppt |
Cell Constant | Adjustable with indication on display |
Temperature Compensation | 0 to 50 °C(Manual) continuously Adjustable |
Display | 0.5” 3 ½ Digit 7 segment Red LED |
Accuracy | ± 1 % of Range ± 1 digit |
Sensor | Platinum Conductivity cell(1.0 cell constant) with Banana male connector |
Input connection | Banana socket |
Operating Environment | 0 to 50 °C / 20 to 95 % RH non condensing |
Power supply | 230V AC / 50 Hz ± 10% |
Overall Dimension in mm | 185 x 235 x 75 (L x B x H) |
Instrument Weight | 2 kg(Approx.) |
SANSEL make digital Conductivity(EC) meter DCM 200 is extremely useful for fast and accurate determination of Conductivity in a liquid. The use of solid state technology and IC circuitry makes this instrument versatile and reliable. The multi position selector switch quickly sets the digital display to the desired test range. The instrument is ideal for testing of natural water, drinking water, waste water, brine solution, sea water and soluble salts, etc.,
Features :
Accessories :
Optional
Specifications
Model | DCM 200 |
---|---|
Range | 0 – 20 μS/ 200 μS/ 2000 μS/ 20 mS / 200 mS ( 5 range selection using front rotary switch ) |
Resolution | 0.01 / 0.1 / 1 for μS & 0.01 / 0.1 for mS |
Cell Constant | Adjustable with indication on display |
Temperature Compensation | 0 to 50 °C(Manual) continuously Adjustable |
Display | 0.5” 3 ½ Digit 7 segment Red LED |
Accuracy | ± 1 % of Range ± 1 digit |
Sensor | Platinum Conductivity cell(1.0 cell constant) with Banana male connector |
Input connection | Banana socket |
Operating Environment | 0 to 50 °C / 20 to 95 % RH non condensing |
Power supply | 230V AC / 50 Hz ± 10% |
Overall Dimension in mm | 185 x 235 x 75 (L x B x H) |
Instrument Weight | 2 kg(Approx.) |
SANSEL make digital ORP(Oxidation Reduction Potential)/ Redox meter is a precise and rugged instrument Carefully designed for the most accurate measurement of pH in Laboratories and industries. The instruments are completely IC version using “MOFSET” input “OP - AMP” and CMOS ICS. It is a met al cabinet of elegant shape. All the controls that are in regular use have been incorporated in the front panel for operational easy. The instrument is capable of measuring millivolts with auto. Polarity for redox potentials and potentiometric tirations. This instrument Operates from 180V to 230V AC 50Hz.
Features :
Accessories :
Specifications
Model | ORP 300 |
---|---|
Range | -1999 to +1999 mV |
Input Impedance | > 10¹² Ohms |
Resolution | 1 mV |
Display | 0.5” 3 ½ Digit 7 segment Red LED |
Accuracy | ± 1 mV ± 1 digit |
Electrode | ORP Electrode with BNC attachment |
Input connection | BNC socket |
Operating Environment | 0 to 50 °C / 20 to 95 % RH non condensing |
Power supply | 230V AC / 50 Hz ± 10% |
Overall Dimension in mm | 185 x 235 x 75 (L x B x H) |
Instrument Weight | 1.7 kg(Approx.) |
Clarity of water is extremely important in products destined for human consumption. Suspension free water is also considered necessary for industries manufacturing beverage, food products etc. Similarly, minimum limits of turbidity are required to be observed in drinking water & sewage disposals. SANSEL Digital Nephelometer Model DN 1000 are ideal instruments for measurement of suspensions. They consist of a light source focused on a test tube containing the sample solution under test. The light, reflected at right angle to the focused light by the suspension in the solution, is detected by the photo electric detector, amplified and displayed on a 3½ digit LED display.
Features :
Accessories :
Specifications
Model | DN 1000 |
---|---|
Range | 0 to 19.9 & 199.9 NTU |
Resolution | 0.1 NTU |
Detector | Photo Diode |
Display | 0.5” 3 ½ Digit 7 segment Red LED |
Test Tube | 30mm Dia Clear Glass Test tube x 4 nos |
Light Source | High Intensity 5mm White LED |
Operating Environment | 0 to 50 °C / 20 to 95 % RH non condensing |
Power supply | 230V AC / 50 Hz ± 10% |
Overall Dimension in mm | 220 x 200 x 110 (L x B x H) |
Instrument Weight | 2 kg(Approx.) |
We are a leading service provider for calibration of various types of parameters in all industries and our lab is accredited by (NABL)National Accreditation Board for Testing and Calibration laboratories from Chennai, Tamil Nadu, India.
Type of Instruments CalibratedGaugesVernier CaliperExternal Micrometer
Height gaugePlunger dial guageDepth gaugeSnap gauge, etc.
Features :
Specification :
Features :
Specifications :
Features :
Specifications
Model | BW 16 D |
---|---|
Range | 0 to 999999 Counts |
Display | 4 '' 6 digit, 7 Segment RED LED |
Input | 3-30V DC from Proximity sensor,Photo electric non-contact sensor,Encoder Potential free contact,Limit switch,etc |
Resolution | 1 count/pulse |
Sensor Supply | 12 V DC |
Power Supply | 230 VAC |
Features :
Specifications
Model | PI 590-1 |
---|---|
Input | : -75 to +75mV / 0 to +20mA / -10 to + 10V ( programmable Input Lo & Hi Limits) |
Range | -199999 to +199999 (programmable Range Lo & Hi Limits) |
Resolution | 0.00001 / 0.0001 / 0.001 / 0.01 / 0.1 / 1 (selectable) |
Accuracy | ± 0.1% of FS / ± 0.05 % of FS |
Display | 16 Character x 2 Line LCD |
Relay Output (Optional) | 2 NO , 2 COM 5 A Rated Relay with individual H / L set |
Re transmission Output | |
(Optional) | 4 - 20 mA (or) 0 - 10V DC (Factory Selectable) |
Sensor Supply | 24 V DC / 100 mA |
Working temperature | 0 - 50 ºC |
Power Supply | 90 to 270V AC / DC 50Hz |
Dimension | 96 x 96 x 65 mm. |
Weight | 200 grams (Approx.) |
Features :
Specification :
SANSEL offers PROCESS INDICATORs are extremely versatile Indicators that can be used for a wide variety of applications. These INSTRUMENT offer extreme reliability and low cost for Process measurement and logging. PI 542A is a Microprocessor based instrumentation ensures accurate readings for all LinearParameters. A number of programmable features including In-line calibration are standard. All the parameters are saved in a non volatile EEPROM memory which doesn't needs any external battery.PI 542A can offer relay outputs for signals exceeding set points. Programmable Re Transmission output models are also available in addition to the industry standard 4 -20mA or 0 - 10V DC output. Optional RS 485 (2 wire ) output also provided for PC communication with PC Interface software & also with MODBUS RTU protocol.
Features
Specification
Fetaures
Specification
Features
Specification
Features :
Specifications
The most time-consuming part of carrying out a microbial count is the actual counting process on petri dishes. Colony counters facilitate this task and as a result are essential in every bacteriological laboratory. Their particular advantages are the easy, rapid and reliable counting of bacterial colonies with very simple handling. SANSEL colony counter Model CC 100 is easy to use and allows fatigue-free and safe work thanks to its problem-free counting mechanism: Marking the colonies on the petri dish with the marker pen activates the counter.
Fearures :
Accessories :
Specifications
Model | CC 100 |
---|---|
Range | 0 to 9999 counts |
Input | Count Pulse for Electronic Marker Pen |
Resolution | 1 count |
Disk Diameter | 110 mm |
Display | 0.5” 4 Digit 7 segment Red LED |
Magnification | x1.7 Surface |
Count Reset | Push Button Provided on front panel |
Input connection | 2 Pin Female Socket |
Operating Environment | 0 to 50 °C / 20 to 95 % RH non condensing |
Power supply | 230V AC / 50 Hz ± 10% |
Overall Dimension in mm | 270 x 220 x 160 (L x B x H) |
Instrument Weight | 2.5 kg(Approx.) |
SANSEL Model TCAL 1402 / -20 Miniature calibrator bath are one of the smallest dry well calibrator in the world, which are ideally suited were necessary for fast calibration in process industries to calibrate Thermocouple, RTD, Indicator with sensor & transmitter with sensor. Temperature range of the TCAL 1402 / -20 covers from -15°C* to 75°C. These equipment are light weight, fast raising, quick settling, better stability & uniformity. TCAL 1402 / -20 Miniature calibrator bath’s temperature are adjusted simply using 4 keys on the controller, can be very quickly controlled the actual and set temperature can be displayed simultaneously on a 4+4 digit high brightness LCD. TCAL 1402 / -20 having interchangeable inserts to suit for calibration of different diameter of sensors (upto 16mm). Additional Inserts(optional) with special drillings are available to order.
Features :
Accessories
Optional
Specifications
Model | TCAL 1402 / -20 |
---|---|
Temperature Range | -15* to 75°C (extended model available upto 110°C on request) (* @ Ambient 25°C) |
Resolution | 0.1 °C |
Stability | ± 0.1 °C |
Axial + Radial Uniformity | Better than ± 0.3 °C |
Display | 0.58” (15mm)(Block) / 0.3”(7.8mm) (Set) 4 digit LCD Display with 4 keys |
Accuracy | ± 0.3 °C |
Temperature Read out | °C |
Heating time | 15 mins (Amb. to 75°C) |
Cooling time | 20 mins (25 to -15°C) |
Stabilization time | 3 minutes |
Well Dimension | 16 x 100 mm (dia. x height), 80mm (immersion depth) |
Standard well holes in mm | 5.2 , 6.2 |
Power supply | 230V AC ± 10% / 50Hz (Optional 110V AC) |
Power Consumption | 500 VA |
Overall Dimension in mm | 260 x 145 x 290 (L x B x H)(Approx.) |
Instrument Weight | 8 kg(Approx.) |
Features :
“SANSEL” series TCAL 1501 / 250 is a micro controller based precision “Liquid temperature calibrator” generates true reference temperature. The temperature controller of the calibrators uses a auto tune FUZZY PID controller algorithm. This response closely follows the heating curve of an actual thermal system. Place the Thermometers, Thermocouples & RTDs to be calibrated in the calibrator. Set the temperature from the 4.3 inch true TFT display with touch screen. Both Block and set temperature can be read. When stabilization occurs, Simply read the temperature and re-calibrate the Thermometer, sensor etc, . or comparison with master RTDs reading.
Features :
Specifications :
Accessories :
SANSEL Model TCAL 1402 / 500 Miniature calibrator bath are one of the smallest dry well calibrator in the world, which are ideally suited were necessary for fast calibration in process industries to calibrate Thermocouple, RTD, Indicator with sensor & transmitter with sensor. Temperature range of the TCAL 1402 / 500 covers from Ambient + 5°C to 500°C. These equipment are light weight, fast raising, quick settling, better stability & uniformity. TCAL 1402 / 500 Miniature calibrator bath’s temperature are adjusted simply using 4 keys on the controller, can be very quickly controlled the actual and set temperature can be displayed simultaneously on a 4+4 digit high brightness LCD. TCAL 1402 / 500 having interchangeable inserts to suit for calibration of different diameter of sensors (upto 20mm). Additional Inserts(optional) with special drillings are available to order.
Features :
Accessories
Optional
Specifications
Model | TCAL 1402 / 500 |
---|---|
Temperature Range | Amb.+5 to 500°C |
Resolution | 0.1 °C |
Stability | ± 0.1 °C @ 200°C |
Axial + Radial Uniformity | Better than ± 0.5 °C |
Display | 0.58” (15mm)(Block) / 0.3”(7.8mm) (Set) 4 digit LCD Display with 4 keys |
Accuracy | Better than ± 1 °C |
Temperature Read out | °C |
Heating time | 40 °C / minute |
Cooling time | 30 °C / minute |
Stabilization time | 3 minutes |
Well Dimension(dia. x height) | 20 x 90 mm |
Standard well holes in mm | 6.2 , 6.2 |
Power supply | 230V AC ± 10% / 50Hz (Optional 110V AC) |
Power Consumption | 750 VA |
Overall Dimension in mm | 150 x 90 x 190 (L x B x H)(Approx.) |
Instrument Weight | 2 kg(Approx.) |
SANSEL Model TCAL 1402 / 300 Miniature calibrator bath are one of the smallest dry well calibrator in the world, which are ideally suited were necessary for fast calibration in process industries to calibrate Thermocouple, RTD, Indicator with sensor & transmitter with sensor. Temperature range of the TCAL 1402 / 300 covers from Ambient + 5°C to 300°C. These equipment are light weight, fast raising, quick settling, better stability & uniformity. TCAL 1402 / 300 Miniature calibrator bath’s temperature are adjusted simply using 4 keys on the controller, can be very quickly controlled the actual and set temperature can be displayed simultaneously on a 4+4 digit high brightness LCD. TCAL 1402 / 300 having interchangeable inserts to suit for calibration of different diameter of sensors (upto 20mm). Additional Inserts(optional) with special drillings are available to order.
Features :
Accessories
Optional
Specifications
Model | TCAL 1402 / 300 |
---|---|
Temperature Range | Amb. to 300°C |
Resolution | 0.1 °C |
Stability | ± 0.1 °C |
Axial + Radial Uniformity | Better than ± 0.3 °C |
Display | 0.58” (15mm)(Block) / 0.3”(7.8mm) (Set) 4 digit LCD Display with 4 keys |
Accuracy | ± 0.3 °C |
Temperature Read out | °C |
Heating time | 25 °C / minute |
Cooling time | 15 minutes (300 to 100 °C) |
Stabilization time | 3 minutes |
Well Dimension(dia. X height) | 20 x 90 mm |
Standard well holes in mm | 6.2 , 6.2 |
Power supply | 230V AC ± 10% / 50Hz (Optional 110V AC) |
Power Consumption | 500 VA |
Overall Dimension in mm | 150 x 90 x 190 (L x B x H)(Approx.) |
Instrument Weight | 2 kg(Approx.) |
These are Master Thermocouple without Cold Junction. This range is based on popular Standard Thermocouple range, Sensitivity & Length.
MTC are highly accurate and stable Thermocouple with minimum uncertainties. It offer wide temperature range which is ideal for all industrial applications. The size, length and Thermocouple Material are such that give the best and most stable results.
Features :
Specifications
Type | N / K | R / S |
---|---|---|
Material | NiCrSi-NiSi /NiCr-NiAl | Pt-13RhPt /Pt-10RhPt |
Temperature Range | upto 1200 | upto 1500 |
Sensitivity | 39 - 41 μV /°C | 6 - 12 μV /°C |
Accuracy ±1.1 | ±1.1 °C or ±0.4% | ±0.6 °C or ±0.1% |
Sheath Diameter | 6mm | 6mm |
Sheath Length | 300mm, 450mm,600mm | 300mm, 450mm,600mm |
Cable Length | 1000mm or as Required | 1000mm or as Required |
Outer Sheath | Inconel | Ceramic |
End Connection Flying Lead | Flying Lead | Flying Lead |
SANSEL Model TCAL 1401 / -30 Dry well Temperature calibrator are high performance for industrial atmosphere and covering temperature range from -30* to 100°C. Which are ideally suited onsite calibration of thermocouple, RTDs, Indicator with sensors & 4-20mA signal transmitter with indicator in Food, Pharmaceutical and all types of process industries. Having it’s advantage of user friendly, light weight, portable, fast settling, better uniformity and accuracy over a wide temperature range. TCAL 1401 / -30 having interchangeable inserts to suit for calibration of different diameter of sensors (upto 16mm). Additional Inserts(optional) with special drillings are available to order.
Features :
Accessories
Optional
Specifications
Model | TCAL 1401 / 600 |
---|---|
Temperature Range | Amb.+5 to 600°C |
Resolution | 0.1 °C |
Stability | ± 0.1 °C |
Axial + Radial Uniformity | Better than ± 1 °C |
Display | 0.58” (15mm)(Block) / 0.3”(7.8mm) (Set) 4 digit LCD Display with 4 keys |
Accuracy | Better than ± 1 °C |
Temperature Read out | °C |
Heating time | 30 mins (Amb. To 600 °C) |
Cooling time | 25 mins (600 to 100 °C) |
Stabilization time | 15 minutes |
Well Dimension(dia. X height) | 30 x 110 mm |
Standard well holes in mm | 4.2, 6.2 , 6.2 & 8.5 |
Power supply | 230V AC ± 10% / 50Hz (Optional 110V AC) |
Power Consumption | 1200 VA |
Overall Dimension in mm | 285 x 125 x 275 (L x B x H)(Approx.) |
Instrument Weight | 7.5 kg(without well insert)(Approx.) |
Features :
SSPRT is Highly Accurate Platinum Resistance Thermometer(PT 100) offer the temperature range of - 80 to 660ºC. SSPRT gives the benefit of high accuracy and low drift in a solid metal case. Wire wound resistance element give good stability with low temperature coefficient and high accuracy.
SSPRT is constructed with a 6 mm outer diameter of Inconel sheath of high durability. SSPRT is available in different accuracies and length. A special powder mixture is filled into the sensor capsule to support the element from mechanical shocks.
Features :
Specifications :
Features :
We are a leading service provider for calibration of various types of parameters in all industries and our lab is accredited by (NABL)national accreditation board for testing and calibration laboratories from Chennai, Tamil Nadu, India.
Very Low Pressure ± 25 mbar
Type of Instruments CalibratedManometerLow pressure Transducer/TransmitterGaugesDifferential Pressure Indicator/TranmitterPressure Data LoggerPressure switchLow pressure Calibrators, etc.,
Absolute Pressure: 0.60 bar to 2 bar
Type of Instruments CalibratedBarometersAneroid barometerAbsolute gaugesAbsolute pressure sensor/TranmitterAbsolute pressure indicator/ controllerLogger and Calibrators etc
Vacuum: -0.1 bar to -0.99 bar
Type of Instruments CalibratedVacuum GaugeVacuum Tranduer/TransmitterVacuum Indicator/Controller/SwitchVacuum LoggerCalibrators etc.,
Pressure(Hydraulic and Pneumatic) 1 bar to 1000 bar and 0.1 bar to 35 bar
Type of Instruments CalibratedPressure CalibratorsPressure TransducerPressure TransmitterDigital Pressure GaugesPressure ControllerPnueumatic pressure gaugesHydraulic Pressure gaugesDifferential pressure indicators, etc.,
Mass/Weight 1 mg to 50 kg
Type of Instruments Calibrated(Accuracy class: E2, F1, F2, M1, M2, ETC., )Standard weight boxWeights, etc., Weighing Scale and Balance 1mg to 300 KgMicro balanceAnalytical balanceDigital balanceWeighing Scale
Volume 1µl to 5l
Type of Instruments CalibratedPipetteBuretteFlaskbeakerAll types of measuring cylinder
Acoustic Pressure : Range 94 & 114 DB
Type of instruments Calibratedsound level meter, etc., Contact RPM/Tachometer: 100 RPM to 10000 RPMNon - Contact RPM/Tachometer: 12 RPM to 99950 RPMType of Instruments CalibartedContact & Non contact type RPM IndicatorContact & Non contact type TachometerCentrifugal, etc., Dimensional(Basic Instrument, Gauge, etc., )Vernier CalipersExternal MicrometerPlunger Dail GaugeLever Type DailBore GaugeHeight GaugesDepth MicrometerDepth GaugesThickness GaugesSnap GaugeFeeler gaugeInternal Micrometerwidth GaugeDial Caliper GaugeMicrometer SettingPlain Plug GaugePistol CaliperThread Measuring WiresMeasuring Pin
We are a leading service provider for calibration of various types of parameters in all industries and our lab is accredited by (NABL)National Accreditation Board for Testing and Calibration laboratories from Chennai, Tamil Nadu, India.
Temperature(Contact) Range from -80 deg C to 1500 deg c
Type of Instruments Calibrated:Digital ThermometerGlass ThermometerDry block Calibrators
Thermocouple and RTD probesThermistorsTemperature RecorderTemperature Scanner/Data loggerTemperature Indicator with sensorTemperature GaugeTemperature TransmitterTemperature bath, etc., Mapping and Validation for single or multi pointFreezerincubatorovenfurnanceStorage roomsclean roomsdryercold roomsEnvironmental chambersHumidity Indicator/chamber, etc., Temperature(Non-Contact)Range from 0 deg c to 1500 deg c
Type of Instruments Calibrated
Non-Contact PyrometersIR thermometerBlack Body Source, ect., Humidity: Range from 5 to 60 deg c & 10 to 95%
Type of Instruments CalibratedHumidity sensors/TransmitterHumidity/Temperature loggerAnalog hygrometerdigital thermal hygrometerThermo hygro graphHumidity chamber etc., Note: Price May vary based on quantity and instruments