Our Product / Services
Electronic Timers
2 Products availableMeasuring Instruments & Equipment
2 Products availableLimit Controller
2 Products availableProcess Control Equipment
2 Services availableAnalytical Instruments
1 Products availableLeading Manufacturer, Supplier & Retailer of BCAL 102 IR Temperature Calibrator, pH Meter, BCAL 502 IR Temperature Calibrator, RPMC 1700 4A Tachometer Calibrator and BCAL 1202 IR Temperature Calibrator.
Features :
Technical Details :
Accessories :
Optional :
SANSEL make digital pH meter is a precise and rugged instrument Carefully designed for the most accurate measurement of pH in Laboratories and industries. The instruments are completely IC version using “MOFSET” input “OP - AMP” and CMOS ICS. It is a met al cabinet of elegant shape. All the controls that are in regular use have been incorporated in the front panel for operational easy. The instrument is capable of measuring millivolts with auto. Polarity for redox potentials and potentiometric tirations. This instrument Operates from 180V to 230V AC 50Hz.
Features
Accessories
Optional
Specifications
Range | 0 to 14 pH / -1999 to +1999 mV |
---|---|
Input Impedance | > 10¹² Ohms |
Resolution | 0.01 pH / 1 mV |
Temperature Compensation | 0 to 50 °C(Manual) continuously Adjustable |
Display | 0.5” 3 ½ Digit 7 segment Red LED |
Accuracy | ± 0.01 pH ± 1 digit / ± 1 mV ± 1 digit |
Electrode | Combined Electrode with BNC attachment |
Input connection | BNC socket |
Operating Environment | 0 to 50 °C / 20 to 95 % RH non condensing |
Power supply | 230V AC / 50 Hz ± 10% |
Overall Dimension in mm | 185 x 235 x 75 (L x B x H) |
Instrument Weight | 1.7 kg(Approx.) |
Features :
Speifications
Accessories :
Optional :
The RPMC 1700 Series is high precision Tachometer calibrator, generates true reference rotation per minute (RPM). This calibrator uses “German technology” with high speed motor, high precision encoder and adoption of a new power full 32 bit CPU in control drive, featuring automated gain tuning function, stability, stable stop, rugged in use and many more.
Due to it’s light weight and rugged Aluminium enclosure, it is suitable for in-house and on-site calibration of contact / non contact Tachometer, Tacho coil, Tacho generator, RPM indicator, RPM transmitter, Speedo meter, Proximity sensor, Stroboscope, etc, .
Features :
Accessories :
Optional :
Specifications
Model | RPMC 1700 - 4A |
---|---|
Control Range | Contact : -12,000 to +12,000 RPM Non Contact : -1,80,000 0 to 1,80,000 RPM |
Resolution | 0.01 RPM |
Display Stability | Contact : ± 0.02 RPM, Non Contact : ± 0.2 RPM |
Stability | Contact : ± 0.2 RPM, Non Contact : ± 2 RPM |
Accuracy | Contact : ± 0.5 RPM, Non Contact : ± 5 RPM |
Display | 7” True colour TFT LCD Display with Touch screen |
Stability Time | Within 5 seconds |
Noise level | < 50dB |
Motor | Ultra stable motor with high resolution Encoder & Drive |
Power supply | 230V AC ± 10% / 50Hz (Optional 110V AC) |
Power Consumption | 750 VA |
Outer Enclosure Construction | Aluminium Anodised |
Overall Dimension | 260mm L x 440mm W x 230mm H (Approx) |
Instrument Weight | 15 kg(Approx.) |
SANSEL Model BCAL 1202, Black body Calibrator is used to measure the accuracy and performance of non-contact Thermometers. Infra red thermometer & online pyrometer calibration is performed by comparison of the temperature measured by UUC and target temperature indicated by the calibrator or using standard pyrometer. Focus the Unit Under Calibration (UUC) to be Calibrate to the target point given in BCAL 1202. Set the Temperature from the Touch screen display. Both True and set Temperature can be read. When Stabilization Occurs, Simply Read the Temperature and re-Calibrate the UUC. Applications in Energy - Production and Energy -Distribution Sectors Glass, Ceramic, Semi Conductor Industries Steel Material Processing Industries Calibration laboratories etc
Features :
Accessories :
Optional :
Specifications
Model | BCAL 1202 |
---|---|
Temperature Range | 500 to 1200°C |
Resolution | 0.1 °C |
Stability | ± 0.5 °C |
Display | 4.3 inch True TFT DISPLAY with touch screen |
Accuracy | Better than ± 1% of reading |
Temperature Read out | °C |
Heating time | 60 minutes (Amb. to 1200 °C) |
Cooling time | 120 minutes (1200 to 100 °C) |
Stabilization time | 30 minutes |
Aperture area | 25 mm |
Emissivity | 0.95 |
Power supply | 230V AC ± 10% / 50Hz (Optional 110V AC) |
Power Consumption | 2200 VA |
Overall Dimension in mm | 350 x 352 x 210 (L x B x H)(Approx.) |
Instrument Weight | 12 kg(without carrying case)(Approx.) |
The RPMC 1700 Series is high precision Tachometer calibrator, generates true reference rotation per minute (RPM). This calibrator uses “German technology” with high speed motor, high precision encoder and adoption of a new power full 32 bit CPU in control drive, featuring automated gain tuning function, stability, stable stop, rugged in use and many more. Due to it’s light weight and rugged Aluminium enclosure, it is suitable for in-house and on-site calibration of contact / non contact Tachometer, Tacho coil, Tacho generator, RPM indicator, RPM transmitter, Speedo meter, Proximity sensor, Stroboscope, etc, .
Features :
Accessories :
Optional :
Specifications
Model | RPMC 1700 - 2A |
---|---|
Control Range | Contact : 0 to 6000 RPM Non Contact : 0 to 90,000 RPM |
Resolution | 0.1 RPM |
Display Stability | ± 0.1 RPM(for both Contact & Non Contact) |
Accuracy | Contact : ± 0.3 RPM, Non Contact : ± 5 RPM |
Display | 4.3” True colour TFT LCD Display with Touch screen |
Stability Time | Within 5 seconds |
Noise level | < 50dB |
Motor | Ultra stable motor with high resolution Encoder & Drive |
Power supply | 230V AC ± 10% / 50Hz (Optional 110V AC) |
Power Consumption | 750 VA |
Outer Enclosure Construction | Aluminium Anodised |
Overall Dimension | 260mm L x 440mm W x 230mm H (Approx) |
Instrument Weight | 13 kg(Approx.) |
The RPMC 1700 Series is high precision Tachometer calibrator, generates true reference rotation per minute (RPM). This calibrator uses “German technology” with high speed motor, high precision encoder and adoption of a new power full 32 bit CPU in control drive, featuring automated gain tuning function, stability, stable stop, rugged in use and many more. Due to it’s light weight and rugged Aluminium enclosure, it is suitable for in-house and on-site calibration of contact / non contact Tachometer, Tacho coil, Tacho generator, RPM indicator, RPM transmitter, Speedo meter, Proximity sensor, Stroboscope, etc, .
Features :
Accessories :
Optional :
Specifications
Model | RPMC 1700 - 3A |
---|---|
Control Range | Contact : 0 to 8000 RPM Non Contact : 0 to 1,20,000 RPM |
Resolution | 0.001 RPM |
Display Stability | Contact : ± 0.002 RPM, Non Contact : ± 0.01 RPM |
Stability | Contact : ± 0.1 RPM, Non Contact : ± 2 RPM |
Accuracy | Contact : ± 0.2 RPM, Non Contact : ± 5 RPM |
Display | 7” True colour TFT LCD Display with Touch screen |
Stability Time | Within 5 seconds |
Noise level | < 50dB |
Motor | Ultra stable motor with high resolution Encoder & Drive |
Power supply | 230V AC ± 10% / 50Hz (Optional 110V AC) |
Power Consumption | 750 VA |
Outer Enclosure Construction | Aluminium Anodised |
Overall Dimension | 260mm L x 440mm W x 230mm H (Approx) |
Instrument Weight | 13 kg(Approx.) |
SANSEL offers PROCESS INDICATORs are extremely versatile Indicators that can be used for a wide variety of applications. These Instrument offer extreme reliability and low cost for Process measurement and logging. PIJ - 542 A1 is a Microprocessor based instrumentation ensures accurate readings for all Linear Parameters. A number of programmable features including In-line calibration are standard. All the parameters are saved in a non volatile EEPROM memory which doesn't needs any external battery. PIJ-542 A1 can offer relay outputs for signals exceeding set points. Programmable Re Transmission output models are also available in addition to the industry standard 4 -20mA or 0 - 10V DC output. Optional RS 485 (2 wire ) output also provided for PC communication with PC Interface software & also with MODBUS RTU protocol.
Features :
Specifications :
Measurement of relevant Climatic data is becoming more and more important.This Humidity & Temperature Indicator offer Very Accurate Measurement of Relative Humidity and Temperature by Excellent readability of the very High intensity Seven Segment LED Display. The Humidity & Temperature Indicator Housed with roughest Case allow the use in tough industrial environments, Latest Technology and well Proven Sensor Guaranteed Highest Accuracy and Long Term Stable Measurement.
Features :
Specifications :
Optional :
SANSEL Model BCAL 1502, Black body Calibrator is used to measure the accuracy and performance of non-contact Thermometers. Infra red thermometer & online pyrometer calibration is performed by comparison of the temperature measured by UUC and target temperature indicated by the calibrator or using standard pyrometer. Focus the Unit Under Calibration (UUC) to be Calibrate to the target point given in BCAL 1502. Set the Temperature from the Touch screen display. Both True and set Temperature can be read. When Stabilization Occurs, Simply Read the Temperature and re-Calibrate the UUC. Applications in Energy - Production and Energy -Distribution Sectors Glass, Ceramic, Semi Conductor Industries Steel Material Processing Industries Calibration laboratories etc
Features :
Accessories :
Optional :
SANSEL Model TCAL 1503 series of Dry well Temperature calibrator range from -45 to 1200 °C in four model (TCAL 1503 / -45, TCAL 1503 / -35, TCAL 1503 / 300, TCAL 1503 / 600 & TCAL 1503 / 1200) are high precision, better resolution, stability, fast in heating and cooling. More well dia and depth to calibrate more number of temperature sensor at a time with better uniformity. These models can meet any calibration requirement in laboratories or in on site applications. This models are inbuilt measuring facility of the Thermocouples, RTD, Resistance, millivolt & milliamps to directly read the signals from most of the temperature sensors, indicator with sensor and Transmitter. Temperature range from -45 to 130 °C with high resolution 0.01 °C up to 130 °C. This model is mainly used in all industries, like Pharmaceutical, food, Research & calibration laboratories etc., These models are using 4.3” True colour TFT display with Touch screen, easy to read multi parameter at the same time like, Block temperature, set temperature, measure value, Real time clock with date & time, Control Output %, Stability time & status, Range of the equipment with necessary unit of measurement and three soft touch keys are used for measure configuration, settings, calibration etc., It has one more advantage of help menu for operating instruction of the equipment via the same screen , Hence no need of Hard copy of Instruction manual.
Features :
Accessories :
Optional
Specifications
Model | TCAL 1503 / -45 |
---|---|
Temperature Range | -45* to 130 °C * @ 23 °C Ambient |
Resolution | 0.01 °C |
Stability | ± 0.02 °C |
Radial Uniformity | Better than ± 0.02 °C |
Axial Uniformity (40mm) | ± 0.1 °C at -45 °C ± 0.1 °C at -30 °C ± 0.05 °C at 0 °C ± 0.05 °C at 100 °C ± 0.2 °C at 130 °C |
Display | 4.3” True colour TFT display with touch screen |
Temperature Read out | °C / °F (selectable) |
Cooling time | 30 mins (25 to -45 °C) 15 mins (25 to -30 °C) 65 mins (130 to 25 °C) |
Heating time | 25 mins (25 to 130 °C) 75 mins (-45 to 130 °C) 52 mins (-45 to 25 °C) |
Stabilization time | 10 minutes |
Well Dimension(dia. x height) | 30 x 160 mm |
Test sensor immersion depth | 130 mm |
Standard well holes in mm | Insert No. 1 5.1, 6.2, 6.2 & 8.1, Insert No. 2 6.2, 6.2 & 10.2 |
Measure inputs | RTD – PT 100, PT 1000, TC – J, K, R, S, T, E, B, N , Analog – mA, mV, Ohms |
Switch Test | Provided |
UUC sensor supply output | 24V DC ± 10% / 50mA max. |
Power supply | 230V AC ± 10% / 50Hz (Optional 110V AC) |
Power Consumption | 500 VA |
Overall Dimension in mm | 390 x 185 x 356 (L x B x H)(Approx.) |
Instrument Weight | 16.6 kg(with well insert)(Approx.) |
SANSEL Model TCAL 1503 series of Dry well Temperature calibrator range from -35 to 1200 °C in four model (TCAL 1503 / -35, TCAL 1503 / 300, TCAL 1503 / 600 & TCAL 1503 / 1200) are high precision, better resolution, stability, fast in heating and cooling. More well dia and depth to calibrate more number of temperature sensor at a time with better uniformity. These models can meet any calibration requirement in laboratories or in on site applications. This models are inbuilt measuring facility of the Thermocouples, RTD, Resistance, millivolt & milliamps to directly read the signals from most of the temperature sensors, indicator with sensor and Transmitter. Temperature range from -35 to 130 °C with high resolution 0.01 °C up to 130 °C. This model is mainly used in all industries, like Pharmaceutical, food, Research & calibration laboratories etc., These models are using 4.3” True colour TFT display with Touch screen, easy to read multi parameter at the same time like, Block temperature, set temperature, measure value, Real time clock with date & time, Control Output %, Stability time & status, Range of the equipment with necessary unit of measurement and three soft touch keys are used for measure configuration, settings, calibration etc., It has one more advantage of help menu for operating instruction of the equipment via the same screen , Hence no need of Hard copy of Instruction manual.
Features :
Accessories :
Optional :
Specifications
Model | TCAL 1503 / -35 |
---|---|
Temperature Range | -35* to 130 °C * @ 23 °C Ambient |
Resolution | 0.01 °C |
Stability | ± 0.02 °C |
Radial Uniformity | Better than ± 0.05 °C |
Axial Uniformity (40mm) | ± 0.2 °C at -35 °C ± 0.15 °C at -15 °C ± 0.07 °C at 0 °C ± 0.15 °C at 100 °C ± 0.2 °C at 130 °C |
Display | 4.3” True colour TFT display with touch screen |
Temperature Read out | °C / °F (selectable) |
Cooling time | 25 mins (25 to -35 °C) 15 mins (25 to -30 °C) 65 mins (130 to 25 °C) |
Heating time | 25 mins (25 to 130 °C) 75 mins (-35 to 130 °C) 52 mins (-35 to 25 °C) |
Stabilization time | 10 minutes |
Well Dimension(dia. x height) | 30 x 160 mm |
Test sensor immersion depth | 130 mm |
Standard well holes in mm | Insert No. 1 5.1, 6.2, 6.2 & 8.1, Insert No. 2 6.2, 6.2 & 10.2 |
Measure inputs | RTD – PT 100, PT 1000, TC – J, K, R, S, T, E, B, N , Analog – mA, mV, Ohms |
Switch Test | Provided |
UUC sensor supply output | 24V DC ± 10% / 50mA max. |
Power supply | 230V AC ± 10% / 50Hz (Optional 110V AC) |
Power Consumption | 500 VA |
Overall Dimension in mm | 390 x 185 x 356 (L x B x H)(Approx.) |
Instrument Weight | 16.6 kg(with well insert)(Approx.) |
SANSEL Model TCAL 1401 / 1200 Dry well Temperature calibrator are high performance for industrial atmosphere and covering temperature range from 500 to 1200°C. Which are ideally suited onsite calibration of thermocouple, RTDs, Indicator with sensors & 4-20mA signal transmitter with indicator in Glass, Steel, Forging and all types of process industries. Having it’s advantage of user friendly, light weight, portable, fast settling, better uniformity and accuracy over a wide temperature range. TCAL 1401 / 1200 having interchangeable inserts to suit for calibration of different diameter of sensors (upto 39mm). Additional Inserts(optional) with special drillings are available to order.
Features :
Accessories :
Optional :
Specifications
Model | TCAL 1401 / 1200 |
---|---|
Temperature Range | 500 to 1200°C |
Resolution | 1 °C |
Stability | ± 2 °C |
Axial + Radial Uniformity | Better than ± 2 °C |
Display | 0.58” (15mm)(Block) / 0.3”(7.8mm) (Set) 4 digit LCD Display with 4 keys |
Accuracy | Better than ± 2°C |
Temperature Read out | °C |
Heating time | 50 mins (Amb. To 1200 °C) |
Cooling time | 120 mins (1200 to 100 °C) |
Stabilization time | 30 minutes |
Well Dimension(dia. X height) | 39 x 150 mm |
Standard well holes in mm | 5.2, 6.2, 6.2, 10.1 & 12.1 |
Power supply | 230V AC ± 10% / 50Hz (Optional 110V AC) |
Power Consumption | 1900 VA |
Overall Dimension in mm | 340 x 175 x 425 (L x B x H)(Approx.) |
Instrument Weight | 18 kg(without well insert)(Approx.) |
“SANSEL” series TCAL 1501 / - 40 is a micro controller based precision “ LOW TEMPERATURE LIQUID BATH” generates true reference temperature with high resolution and stability. The temperature controller of the bath uses a auto tune FUZZY PID controller algorithm. This fast response closely follows the cooling curve of an actual thermal system. Place the Thermometers, Thermocouple & RTDs to be calibrated in the bath. Set the temperature from the 4.3 inch true TFT display with touch screen. Both liquid and set temperature can be read. When stabilization occurs, Simply read the temperature and re-calibrate the Thermometer, sensor etc, . or comparison with master RTDs reading.
Features :
Specifications :
Accessories
SANSEL Model TCAL 1401 / 600 Dry well Temperature calibrator are high performance for industrial atmosphere and covering temperature range from Amb.+5 to 600°C. Which are ideally suited onsite calibration of thermocouple, RTDs, Indicator with sensors & 4-20mA signal transmitter with indicator in Food, Pharmaceutical and all types of process industries. Having it’s advantage of user friendly, light weight, portable, fast settling, better uniformity and accuracy over a wide temperature range. TCAL 1401 / 600 having interchangeable inserts to suit for calibration of different diameter of sensors (upto 30mm). Additional Inserts(optional) with special drillings are available to order. ECONOMY DRY BLOCK TEMPERATURE CALIBRATOR For Thermocouple & RTD Sensor Calibration MODEL : TCAL 1401 / 600 “ Total Solution Under One Roof ” Manufacturing, Servicing & Calibration 15.
Features :
Accessories :
Optional
Specifications
Model | TCAL 1401 / 600 |
---|---|
Temperature Range | Amb.+5 to 600°C |
Resolution | 0.1 °C |
Stability | ± 0.1 °C |
Axial + Radial Uniformity | Better than ± 1 °C |
Display | 0.58” (15mm)(Block) / 0.3”(7.8mm) (Set) 4 digit LCD Display with 4 keys |
Accuracy | Better than ± 1 °C |
Temperature Read out | °C |
Heating time | 30 mins (Amb. To 600 °C) |
Cooling time | 25 mins (600 to 100 °C) |
Stabilization time | 15 minutes |
Well Dimension(dia. X height) | 30 x 110 mm |
Standard well holes in mm | 4.2, 6.2 , 6.2 & 8.5 |
Power supply | 230V AC ± 10% / 50Hz (Optional 110V AC) |
Power Consumption | 1200 VA |
Overall Dimension in mm | 285 x 125 x 275 (L x B x H)(Approx.) |
Instrument Weight | 7.5 kg(without well insert)(Approx.) |
SANSEL Model TCAL 1503 series of Dry well Temperature calibrator range from -100 to 1200 °C in four model (TCAL 1503 / -100, TCAL 1503 / -45, TCAL 1503 / -100, TCAL 1503 / 300, TCAL 1503 / 600 & TCAL 1503 / 1200) are high precision, better resolution, stability, fast in heating and cooling. More well dia and depth to calibrate more number of temperature sensor at a time with better uniformity. These models can meet any calibration requirement in laboratories or in on site applications. This models are inbuilt measuring facility of the Thermocouples, RTD, Resistance, millivolt & milliamps to directly read the signals from most of the temperature sensors, indicator with sensor and Transmitter. Temperature range from -100 to 40 °C with high resolution 0.01 °C up to 40 °C. This model is mainly used in all industries, like Pharmaceutical, food, Research & calibration laboratories etc.,
These models are using 4.3” True colour TFT display with Touch screen, easy to read multi parameter at the same time like, Block temperature, set temperature, measure value, Real time clock with date & time, Control Output %, Stability time & status, Range of the equipment with necessary unit of measurement and three soft touch keys are used for measure configuration, settings, calibration etc., It has one more advantage of help menu for operating instruction of the equipment via the same screen , Hence no need of Hard copy of Instruction manual.
Features :
Accessories :
Optional :
Specifications
Model | TCAL 1503 / -100 |
---|---|
Temperature Range | -100* to 40 °C * @ 25 °C Ambient |
Resolution | 0.01 °C |
Stability | ± 0.05 °C |
Radial Uniformity | Better than ± 0.05 °C |
Display | 4.3” True colour TFT display with touch screen |
Temperature Read out | °C / °F (selectable) |
Cooling time | 90 mins |
Stabilization time | 10 minutes |
Well Dimension(dia. x height) | 30 x 120 mm |
Test sensor immersion depth | 115 mm |
Standard well holes in mm | Insert No. 1 5.1, 6.2, 6.2 & 8.1, Insert No. 2 6.2, 6.2 & 10.2 |
Measure inputs | RTD – PT 100, PT 1000, TC – J, K, R, S, T, E, B, N , Analog – mA, mV, Ohms |
Switch Test | Provided |
UUC sensor supply output | 24V DC ± 10% / 50mA max. |
Power supply | 230V AC ± 10% / 50Hz (Optional 110V AC) |
Power Consumption | 500 VA |
Overall Dimension in mm | 356 x 210 x 534 (L x B x H)(Approx.) |
Instrument Weight | 16 kg(with well insert)(Approx.) |
“SANSEL” series TCAL 1501 / - 80 is a micro controller based precision “ULTRA LOW TEMPERATURE LIQUID BATH” generates true reference temperature with high resolution and stability. The temperature controller of the bath uses a auto tune FUZZY PID controller algorithm. This fast response closely follows the cooling curve of an actual thermal system. Place the Thermometers, Thermocouple & RTDs to be calibrated in the bath. Set the temperature from the 4.3 inch true TFT display with touch screen. Both liquid and set temperature can be read. When stabilization occurs, Simply read the temperature and re-calibrate the Thermometer, sensor etc, . or comparison with master RTDs reading.
Features :
Specifications :
Accessories :
Features :
Measurement of relevant climatic data is becoming more and more important in Clean room , Storage, Manufacturing, Testing and Calibration lab, Research lab etc, . This Humidity, Temperature & Pressure indicator offer very accurate measurement of Relative Humidity, Temperature and Absolute pressure (or) differential pressure by excellent readability of very high intensity seven segment LED display.
The Humidity , Temperature & Pressure indicator housed with rugged case allow to use in tough industrial environments, Latest technology and well proven sensor guaranteed high accuracy and long term stable measurement.
Features :
Specifications
Model | H TP-196 |
---|---|
Display | 3 line 4digit ,0.5” 7 segment LED |
Parameter | T e mp, Humidity & Absolute or differential (pressure) |
Range | 0 to 60°C / 0to100%RH/ 0 to 2000mbarA or ±50pa |
Resolution | 0.01°C / 0.1%RH / 1mbar A (or) 0.01pa |
Set point | Low & High for all three parameter |
Relay | 2 relay with 5A rating with selectable parameter |
Sensor | P T-100, Humidity & Pressure sensor with 2m cable |
Operating Environment | 0 to 5 0 ° C / 20 to 95 %RH Non cond e n s i n g |
Supply | 9 0 to 270V AC / 50Hz |
Dimension | 100 mm W x 250 mm H x60 mm D |
Mounting | W a ll mountable with key hole provision |
Buzzer | Inbuilt |
Weight | 640gms |