Post Buy Requirement
Straton Electricals Private Limited

Straton Electricals Private Limited

gstGST : 36AASCS1302A1ZS Add Review

Power Transformers

We offer a complete product range of 11KV Outdoor Resin Cast Potential Transformer, 11KV Indoor Resin Cast Current Transformer, 33KV Resin Cast Potential Transformer, Medium Voltage Indoor Resin Cast Potential Transformer and Medium Voltage Indoor Resin Cast Current Transformer

11KV Outdoor Resin Cast Potential Transformer

  • Min. Order (MOQ) 3 Piece
  • Type Outdoor Type
  • No. of phases Transformer Oil
  • Insulation class 33KV
  • Rated Voltage 36KV
  • Rated primary current (A) 50HZ
  • Rated secondary current (A) Solidly earthed
  • One minute power frequency withstandvoltage (KVrms) 33KV/RT3//110V/RT3
  • Rated continuous thermal current Star/Star
  • Burden (VA) Upto 200VA
  • Accuracy class 0.1 / 0.2
  • Applicable standard 1.2 Cont./1.9 for 8 hours
  • Mass approx. As per IS
View Complete Details

11KV Indoor Resin Cast Current Transformer

  • Min. Order (MOQ) 3 Piece
  • Type Resin Cast
  • No. of phases Single
  • Insulation class A
  • Rated Voltage Upto 11KV
  • Rated primary current (A) 500A
  • Rated secondary current (A) 1A/5A
  • Basic insulation level (KV) 12/28/70KVp
  • One minute power frequency withstandvoltage (KVrms) 28KV
  • Rated continuous thermal current 1.2 of rated current
  • Burden (VA) As per requirement
  • Accuracy class 0.2/0.5/5P10/PS
  • Applicable standard IS 2705 & IEC
  • Mass approx. 18Kg (Approx.)
View Complete Details

33KV Resin Cast Potential Transformer

  • Min. Order (MOQ) 3 Piece
  • Type Resin Cast
  • No. of phases 33KV/RT3
  • Insulation class 110V/RT3
  • Rated Voltage A
  • Rated primary current (A) 36/70/170KVp
  • Rated secondary current (A) 1.2 Cont./1.9 for 8 hours
  • Basic insulation level (KV) 170KVp
  • One minute power frequency withstandvoltage (KVrms) IS 3156
  • Rated continuous thermal current 33KV/RT3//110V/RT3
  • Burden (VA) Upto 200VA
  • Accuracy class 0.2
  • Applicable standard <50pc
View Complete Details

Medium Voltage Indoor Resin Cast Potential Transformer

  • Min. Order (MOQ) 3 Piece
  • System Voltage Upto 33kV
  • Type Single/three phase, multi-core/ratio
  • Applications Metering, Protection & Special protection
  • Construction Medium Voltage resin cast
  • Metering 0.2S, 0.5, 1.0
  • Protection 3P
  • Primary Upto 33KV
  • Secondary 110V AC

Medium Voltage resin cast Potential Transformers of single core for metering purpose are commonly used. Di-electric strength of the oil-impregnated paper insulation is preserved by hermetic sealing of the transformer.

Characteristics :

  • Non-ageing Epoxy with Class B insulation.
  • Non Hygroscopic.
  • Vacuum cast under controlled conditions.
  • Partial discharges as per allowable limits.
  • Designed to work in high ambient in enclosed switchgears.
  • Good mechanical stability under fault conditions.
View Complete Details

Medium Voltage Indoor Resin Cast Current Transformer

  • Min. Order (MOQ) 3 Piece
  • Applications Metering, Protection & Special protection
  • Construction Medium Voltage resin cast
  • System Voltage Upto 33kV
  • Type Single phase, multi-core/ratio
  • Metering 0.2S, 0.5, 1.0
  • Protection 5P10, 5P20, PS
  • Primary Upto 2500A
  • Secondary 1A / 5A
  • STC Upto 25KA

Medium Voltage resin cast Current Transformers can be equipped with one or more independent magnetic cores with equal or different characteristics for measuring, metering and/or protective purposes.

Characteristics :

  • Non-ageing Epoxy with Class B insulation.
  • Non Hygroscopic.
  • Vacuum cast under controlled conditions.
  • Partial discharges as per allowable limits.
  • Designed to work in high ambient in enclosed switchgears.
  • Good mechanical stability under fault conditions.
View Complete Details

33KV Indoor Resin Cast Current Transformer

  • Min. Order (MOQ) 3 Piece
  • Type Resin Cast
  • No. of phases Single
  • Insulation class A
  • Rated Voltage Upto 11KV
  • Rated primary current (A) 500A
  • Rated secondary current (A) 1A/5A
  • Basic insulation level (KV) 12/28/70KVp
  • One minute power frequency withstandvoltage (KVrms) 28KV
  • Rated continuous thermal current 1.2 of rated current
  • Burden (VA) As per requirement
  • Accuracy class 0.2/0.5/5P10/PS
  • Applicable standard IS 2705 & IEC
  • Mass approx. 18Kg (Approx.)
View Complete Details

6.6KV Indoor Resin Cast Current Transformer

  • Min. Order (MOQ) 3 Piece
  • Type Resin Cast
  • No. of phases Single
  • Insulation class A
  • Rated Voltage Upto 11 KV
  • Rated primary current (A) 3000A
  • Rated secondary current (A) 1A/5A
  • Basic insulation level (KV) 7.2/20/60 KVP
  • One minute power frequency withstandvoltage (KVrms) 20KV
  • Rated continuous thermal current 1.2 of Rated Current
  • Burden (VA) As per Requirement
  • Accuracy class 0.25
  • Applicable standard IS 2705 & IEC
  • Mass approx. 10 Kg Approx.
View Complete Details

6.6KV Resin Cast Potential Transformer

  • Min. Order (MOQ) 3 Piece
  • Type Resin Cast
  • No. of phases 6.6KV/RT3
  • Insulation class 110/RT3
  • Rated Voltage 7.2/20/60KVp
  • Rated primary current (A) IS 3156
  • Rated secondary current (A) 1.2Cont./1.5 for 30Sec
  • Basic insulation level (KV) One end earthed type
  • One minute power frequency withstandvoltage (KVrms) 11KV HRC Fuse
  • Rated continuous thermal current Star/Star
View Complete Details

11KV Resin Cast Potential Transformer

  • Min. Order (MOQ) 3 Piece
  • Type Resin Cast
  • No. of phases 11KV/RT3
  • Insulation class 110/RT3
  • Rated Voltage 12/28/75KVp
  • Rated primary current (A) IS 3156
  • Rated secondary current (A) 1.2Cont./1.5 for 30Sec
  • Basic insulation level (KV) One end earthed type
  • One minute power frequency withstandvoltage (KVrms) 11KV HRC Fuse
  • Rated continuous thermal current Star/Star
View Complete Details

Medium Voltage Outdoor Resin Cast Potential Transformer

  • Min. Order (MOQ) 3 Piece
  • System Voltage Upto 33kV
  • Type Single/three phase, multi-core/ratio
  • Applications Metering, Protection
  • Construction Outdoor Resin Cast
  • Metering 0.2, 0.5, 1.0
  • Protection 3P
  • Primary Upto 33KV
  • Secondary 110V AC

Medium Voltage Oil Cooled Potential Transformers of single core for metering purpose are commonly used. Di-electric strength of the oil-impregnated paper insulation is preserved by hermetic sealing of the transformer.

Characteristics:

  • Oil / Paper Insulation.
  • High insulation reliability.
  • Metal parts corrosion resistive.
  • Porcelain bushing suitable for polluted atmosphere.
  • Easily accessible to LV terminals.
View Complete Details
Tell Us What are you looking for? Will call you back