We are leaders in the market for providing best range of DEFLUORIDATION SYSTEMS, TURBINE - AGITATOR CONTROLLER, Turbine Agitator Controllers and defluoridation system

DEFLUORIDATION SYSTEMS

The demand for safe drinking water is increasing day by day due to burgeoning population and industrial growth. The portability of water from natural sources has become questionable owing to various types of contamination. The quality of water from underground sources on which most of the Indian population depends, is determined by the geological structure of the site and varies widely. The contamination of water with fluoride has been identified in ground water from major parts of India. Because of this, the people in over 15 states have fallen victims. Excess of fluoride over 1.5 ppm (mg/l) in drinking water causes Fluorosis (Dental & Skeletal) and it has become essential to take remedial measures to solve this mammoth problem.

Today's process of Defluoridation is being done by using Activated Alumina or by Reverse Osmosis methods, both of which result in further contamination of ground water due to wastages. Hence the need of the hour is not just Defluoridation but also to prevention of wastages getting into ground.

MAIN ADVANTAGES :
  • No addition of any chemical to remove fluoride
  • No pre of post treatment of water
  • Electrochemically generated aluminium hydroxide is more active
  • Helps in charge neutralisation of other colloidal impurities
  • Automatic removal of other contaminants such as Ca, Mg, HCO3-, Fe2+ etc to certain extent
METHOD:

The system involves a simple mechanism of ELECTROCHEMICAL PROCESS, hence there is no necessity of addition of any chemical. It is a combination of electro-precipitation, electro-coagulation and electro-flotation.

OTHER ADVANTAGES:
  • No usage of chemical for regeneration (as in case of Activated Alumina)
  • No chemical cleaning of Electrodes
  • No further ground water contamination (as in case of Reverse Osmosis)
  • No wastage of water (as in case of Reverse Osmosis)
  • The cheapest method
  • No special training required and can be operated by unskilled persons
  • Most efficient, reliable and simple system
  • Automatic removal of hardness to certain extent
  • No change in pH value
  • Highly reliable and proven technology
  • Community model, hence simple logistics to supply fluoride-free water to villages
View Complete Details

TURBINE - AGITATOR CONTROLLER

  • Agitator exclusively designed with 6 spouts, three of them radial with a centrifugal movement to produce a rotation of liquid, and three of them axial to stir the bottom.
  • Dismountable turbine without edges, for greater security.
  • Direct transmission shaft in stainless steel.

Motor IP55

Three-phase230/400 V 50Hz230/460 V 60Hz

Single-phase230/460 V 60Hz230V 50Hz115/230V 60Hz

12V- DC12V DC

Power-0.6 HP12V DC 80W

View Complete Details

Electrical Controller

  • Type Automatic
  • Voltage 220V
  • Display Type Digital
  • Frequency 50Hz
  • Driven Type Electric
  • Certificate CE Certified
  • Current Type AC, DC

Controller, according to pH/ conductivity/ flow/ external signals, controls the network through automatic regulation of a MULTIFERIC dosing pump with several heads by means of an inverter.

View Complete Details

Turbine Agitator Controllers

We are offering turbine agitator controllers.Agitator exclusively designed with 6 spouts, three of them radial with a centrifugal movement to produce a rotation of liquid, and three of them axial to stir the bottom.Dismountable turbine without edges, for greater security.Direct transmission shaft in stainless steel.Motor ip55three-phase 230400 v 50hz 230460 v 60hzsingle-phase 230460 v 60hz 230v 50hz 115230v 60hz12v dc 12v dcpower 0.6 hp 12v dc 80w
View Complete Details

Defluoridation System

Main Advantages : No addition of any chemical to remove fluorideNo pre of post treatment of waterElectrochemically generated aluminium hydroxide is more activeHelps in charge neutralisation of other colloidal impuritiesAutomatic removal of other contaminants such as Ca, Mg, HCO3-, Fe2+ etc to certain extentMethod: The system involves a simple mechanism of ELECTROCHEMICAL PROCESS, hence there is no necessity of addition of any chemical. It is a combination of electro-precipitation, electro-coagulation and electro-flotation. Other Advantages: No usage of chemical for regeneration (as in case of Activated Alumina)No chemical cleaning of ElectrodesNo further ground water contamination (as in case of Reverse Osmosis)No wastage of water (as in case of Reverse Osmosis)The cheapest methodNo special training required and can be operated by unskilled personsMost efficient, reliable and simple systemAutomatic removal of hardness to certain extentNo change in pH valueHighly reliable and proven technologyCommunity model, hence simple logistics to supply fluoride-free water to villages
View Complete Details

Skid Mounted Dosing System