The output ratings for continuous duty are for the maximum output voltage. For lower voltage taps the permissible output with constant current must be correspondingly reduced. The output supply for an ambient temperature of maximum 45C & altitudes upto 1000 meters above sea level. In case of continuous duty with short time loads, Control Circuit Transformers can be subjected to upto 300 contactor operations per hour with the short time loads in excess of the continuous ratings. The restaurant drop of the on - load output voltage will not exceed 5%.
salient features of vpispecially designed step core for reduced lossesmultiple conductors for better heat dissipationvacuum pressure impregnated for better penetrationmechanical sturdy design to withstand vibrationsthermistors embedded in winding for over temperature protectionround coils for better short circuit withstand capacitylow noise
other specificationsinsulation class f as standard ; h class insulation can be provided on requesttermination: nickel plated brass bolts as standard , bus bars on requestnoise level less than 60db at rated load at 1 meter distance standard accessorieslifting lugsip 20 enclosurerelay for alarm and tripearthing boltsrating and diagram plate |
Typical Specifications for VPI Lighting Transformers
Rating | Standard Voltage Ratio | Dimensions | Losses | % Impedance | |||
L | W | H | No Load | Full Load | |||
10 | 415/415 | 600 | 600 | 600 | 160 | 220 | <4% |
25 | 415/415 | 700 | 700 | 700 | 280 | 600 | <4% |
30 | 415/415 | 700 | 700 | 700 | 300 | 625 | <4% |
40 | 415/415 | 830 | 700 | 720 | 350 | 650 | <4% |
50 | 415/415 | 900 | 750 | 750 | 375 | 800 | <4% |
60 | 415/415 | 950 | 775 | 875 | 400 | 825 | <4% |
70 | 415/415 | 950 | 775 | 900 | 600 | 850 | <4% |
75 | 415/415 | 1025 | 800 | 950 | 650 | 900 | <4% |
80 | 415/415 | 1050 | 800 | 950 | 700 | 1200 | <4% |
100 | 415/415 | 1050 | 800 | 950 | 750 | 1500 | <4% |
125 | 415/415 | 1080 | 800 | 1000 | 800 | 1800 | <4% |
150 | 415/415 | 1200 | 900 | 1000 | 1000 | 2400 | <4% |
200 | 415/415 | 1300 | 1000 | 1050 | 1300 | 3000 | <4% |
250 | 415/415 | 1300 | 1000 | 1300 | 1400 | 3600 | <4% |
350 | 415/415 | 1450 | 1000 | 1600 | 1600 | 4000 | <4% |
450 | 415/415 | 1650 | 1000 | 1650 | 1750 | 4500 | <4% |
500 | 415/415 | 1650 | 1400 | 1650 | 1800 | 5000 | <4% |
Impedance bond is one of the most important component in Railway SignalingImpedance Bond provides electrical continuity for traction return current despite discontinuity caused by Insulated JointsImpedance Bond Transforms and Transfers Signals between Tracks and Signaling Components located in the CabinsImpedance Bond offers high Impedance to the signals generatedfrom the components located inthe cabinsthus protecting them against surgesImpedance bond offers galvanic insulation between the components located in the Cabin and the track.