Features
4.3, 7 and 10.2 TFT Color display with Optional Pluggable I/O modules
Easy to connect and configure

Wide range of All-in-one (Digital and Analog) I/O modules

One USB Host port
One Ethernet port with multiple protocol support and FTP
One SD card slot for programming or data logging
Supports Horizontal and Vertical display orientation
High quality color display
Front Panel mounting with IP66 rating
Multilanguage support with true type Windows fonts
CE, UL Class I Div 2, RoHS

View Complete Details

Keypad Based HMI Pluggable I/O Flexi Panels

  • Power  + 24V DC ±15%   FP4020 - 2 W Max  FP4030 - 3 W Max
  • Bezel  IP66 rated Keypad
  • Operating Temperature  0o to 50oC
  • Storage Temperature  -20o to 80oC
  • Humidity  10% to 85% (Non condensing)
  • Communication Port  One Serial Port  (RS232 / RS422 / RS485 levels supported)
  • USB Device Port  As programming and monitoring port
  • Type of LCD  Multicolor Backlight LCD
  • Isolation  Isolation between communication and power   ports is 500 V DC for 1 Min.
  • Immunity to ESD  as per IEC61000-4-2
  • Immunity to Fast Transients  as per IEC61000-4-4
  • Immunity to Radiated electromagnetic field  as per IEC61000-4-3
  • Immunity to Conducted disturbances  as per IEC61000-4-6
  • Surge  as per IEC61000-4-5
  • Radiated emission  as per EN55011
Features
16 x 2 Text and 3.1 Graphical / Multicolor Backlight LCD Display

Floating point support, Bar graph, Built-in RTC

Integrated / Pluggable Digital and Analog Inputs and Outputs
Digital Outputs - OC / Relays
Analog Inputs for RTD, mV, mA, Thermocouple, 0 to 5 VDC, 0 to 10 VDC, -10 to +10VDC
Analog Outputs are 4-20 mA / 0-10 VDC
High Speed Counters and Timers
Support for Quadrature inputs and PWM output

Ladder editor with powerful instruction set

Support for Recipes
Communication Ports:One serial port to connect PLC at RS232 / 422 / 485 levels / Printer / Progamming PortOne USB (device) port as Programming Port
User defined Function keys to support various tasks
Alarms (Real Time & Historical)
Multilanguage (Unicode) support with true type Windowsfonts for graphical model
IP66 design. CE, UL approved. RoHS compliant

Operations

The FlexiPanelssupport Operator interface features. The user can also implement logic, specific to application using standard Ladder programming. A PLC logic block can be executed at power up, during every scan or upon a timer interrupt. The FlexiPanelsoperator interface functions revolve around Screens and Tasks that can be assigned to screens and application.

Integrated Digital I/OFP4030MR-L1208R model can have up-to 12 digital Inputs integrated to the unit. Digital inputs are high impedance 24 VDC. The unit can also have up-to 08 digital outputs. Outputs are 06 relays + 02 transistor outputs (NPN).

Pluggable I/O (Digital)FlexiPanelshave facility to support I/O using pluggable I/O modules. The I/O modules can be selected based on the application requirement. Each high speed I/O module can support 4 nos. of high speed inputs of 25KHz. Quadrature input of up-to 20KHz is also supported. Each high speed I/O Module can support 1 quadrature input of 20KHz or 2 quadrature inputs of 5KHz. Each high speed I/O Module can support up-to 2 PWM outputs of 10KHz. Up-to 3 I/O modules can be connected to FP4030MR-E model.

Analog I/OFP4030MR-E supports pluggable Analog I/O Modules. FlexiPanelscan have up-to 24 Analog inputs and / or 6 Analog outputs. The Analog inputs are 0-5 VDC, 0-10 VDC, 4-20 mA, mV, TC, RTD, - 10 to + 10 VDC and Analog outputs are 4-20mA / 0-10VDC. User can Plug only Analog I/O modules or use them in combination with Digital I/O.

Function KeysFlexiPanels HMIs are available with function keys and Numerical keypad for easy data entry. The Function keys also have built-in LEDs. These function keys are screen dependent Function Keys. User can assign any application related task / actions to these function keys.

AlarmsReal time and historical Alarms can be defined in FlexiPanels. User-friendly Alarm object can be defined on the display. Alarms can be real time or historical. Keys can be assigned to acknowledge Alarm, view and scroll.

RecipesRecipes data is stored in the FlexiPanelsmemory. With one button stroke, a set of data can be downloaded to the PLC. Once in the local memory, the recipes data can be edited using simple data entry objects.

Bitmaps / WizardsDifferent bitmaps can be embedded on the FlexiPanelsscreen (Graphical Model). Bitmaps can be imported into the application and displayed on the FlexiPanelsscreens. In addition, several wizards are supported to create commonly used objects such as Analog meters, Lamps, Buttons and Bar graphs.

Ladder SupportFlexiPanelssupport ladder functionality. User can define logic in the unit using FlexiSoftsoftware. The execution of ladder could be through communication port or through I/O. Only HMI version of FlexiPanelsalso support ladder functionality. It is used for critical applications where data is processed before sending it to controller. The FlexiLogicssupport following different types of instructions :

The execution of ladder logic is in microseconds. Ladder monitoring for debuggingis also supported in FlexiPanelsconfiguration software.

Multilanguage / Unicode SupportAll the languages are supported in the FlexiPanels(Graphical Model). The user can now display messages, alarms in any regional / local language. All Windowsfonts can also be used for text in an application.

Communication PortsFunction Keys based FlexiPanelshave one serial communication port. The serial port can be used for programming of FlexiPanels, printing screens (alphanumeric data), connecting to third party serial devices (barcode readers, temp scanners etc.) or to connect to a PLC or drive. User can configure serial port for RS232 or RS485 communication.

Configuration SoftwareFlexiSoftis a compact, Windowsbased software to configure the FlexiPanelsunits. User friendly configuration tools and easy approach, helps user create applications quickly and easily.

I/O Instructions
NO contact NC contact Output
Falling Edge Rising Edge Inverter
Inverter Coil Positive Pulse Contact Negative Pulse Contact
Positive pulse coil Negative Pulse Coil
 Data Transfer
MOV word MOV DWORD Invert Transfer
Table Initialize Table Block Transfer Table Invert Transfer
Data Exchange Multiplexer Demultiplexer
 Math
Addition Subtraction Multiplication
Division Addition with Carry Subtraction with Carry
Increment Decrement  
 Compare
Greater than Greater than or equal Equal
Not Equal Less Than Less than or Equal
 Logic
AND OR XOR
Shift Rotate
 Data Conversion
Hex to Ascii Ascii to Hex Absolute Value
7 segment decode Ascii conversion Binary Conversion
BCD conversion 2's complement word
2's complement Double word
Timer
TON TOFF TSS
Counter
Up counter UP Down Counter  
Program Control
Subroutine CALL Subroutine RET For
Next Master Control Set Master Control Reset
Jump Control Set Jump Control Reset En Intr
Dis Intr DT Step sequence Init
Step sequence Input Step sequence output
Function
Moving Average Digital Filter PID1,4
Upper limit Lower limit Maximum Value
Minimum Value Average Value Function generator
Special
Device Set Device Reset Register Set
Register Reset Set Carry Reset Carry
Encode Decode Bit Count Flip Flop
Direct I/O Set Calender Calender Operation

Model Comparison

 Product   Model

 Display

LCD Life
at 25oC
Key

Memory

PLC 
Steps

Screen 
Memory

Local I/O

Expansion Serial 
Ports**

USB

RTC Power
Consu-mption
Weight
(Approx.)
FP4020 FP4020MR-L0808N 16x2 Text
Multicolor backlight
40000 hrs 18 Up-to
512 k
10 k Up-to
84 KB
8 DC in
8 NPN 0.5A
NA 1 Device Yes 2W 215 gms.
FP4020MR-L0808P 16x2 Text
Multicolor backlight
40000 hrs 18 Up-to
512 k
10 k Up-to
84 KB
8 DC in
8 PNP 0.5A
NA 1 Device Yes 2W 215 gms.
FP4020MR-L0808R 16x2 Text
Multicolor backlight
40000 hrs 18 Up-to
512 k
10 k Up-to
84 KB
8 DC in 6 Relays 2A
2 NPN 0.5A
NA 1 Device Yes 2W 220 gms
FP4030 FP4030MR-L1208R 128x64 
Graphical
Multicolor backlight
30000 hrs 18 Up-to
1.5 MB
10 k Up-to
1 MB
12 DC in 6 Relays 2A
2 NPN 0.5A
NA 1 Device Yes 3W 320 gms.
FP4030MR-E 128x64 
Graphical
Multicolor backlight
30000 hrs 18 Up-to
1.5 MB
10 k Up-to
1 MB
NA 3 1 Device Yes 3W 265 gms.























 

 Pluggable Expansion Modules (Digital I/O) Power Consumption Weight
 FPED0808P  8 Digital inputs (PNP or NPN) and 8 outputs (0.5A PNP transistor) 0.3 W 70 gms.
 FPED-HS-0808P#  8 Digital inputs and 8 Digital Outputs (PNP Type) 0.3 W 70 gms.
 FPED0808N  8 Digital inputs (PNP or NPN) and 8 outputs (0.5A NPN transistor) 0.3 W 70 gms.
 FPED-HS-0808N#  8 Digital inputs and 8 Digital Outputs (NPN Type) 0.3 W 70 gms.
 FPED0012R   12 Digital outputs (Relay) 0.3 W 90 gms.
 FPED1600   16 Digital inputs 0.3 W 65 gms.
 FPED0016N  16 Digital outputs (0.5A NPN transistor) 0.3 W 65 gms.
 FPED0016P  16 Digital outputs (0.5A PNP transistor) 0.3 W 75 gms.
 FPED-HS-0808RP  8 Digital inputs (PNP or NPN) and 8 outputs (6 Relay, 2 PNP) 0.3 W 70 gms.
 FPED-HS-0808RN  8 Digital inputs (PNP or NPN) and 8 outputs (6 Relay, 2 NPN) 0.3 W 70 gms.













 

 




 

 Pluggable Expansion Modules (Analog I/O) Power Consumption Weight
 FPEA0202L  2 Analog inputs (4-20mA, 0 – 20mA, 0 – 10 V, -10 to + 10V ranges) 
 2 Analog Outputs (4-20mA, 0 – 20mA, 0 – 10 V)
0.3 W 85 gms.
 FPEA0400L  4 Analog inputs (4-20mA, 0 – 20mA, 0 – 10 V, -10 to + 10V ranges) 0.3 W 80 gms.
 FPEA-0402U-16  4 Universal Analog Inputs (4-20mA, 0 – 20mA, TC , RTD, 
 0-5V, 0 – 10 V, 0-50mV, 0 - 100mv ranges)
 2 Analog Outputs (4-20mA, 0 – 20mA, 0 – 10 V). 
  All AI/O 16 bit resolution
0.3 W 90 gms.
 FPEA0800LC  8 Analog inputs (4-20mA) 0.3 W 90 gms.
 FPEA0800LV  8 Analog inputs (0-10VDC) 0.3 W 90 gms.


















 






















































































View Complete Details

Touch Screen Based HMI Flexi Panels

  • Power + 24V DC ±15% FP4030MT - 3 W Max FP4035 - 3 W Max FP5043 - 5 W Max FP4057 - 7 W Max FP5070 - 9 W Max
  • Bezel  IP66 rated Touch Screen
  • Operating Temperature  0o to 50oC
  • Storage Temperature  -20o to 80oC
  • Humidity  10% to 85% (Non condensing)
  • Communication Port  One / Two Serial Ports**  (RS232 / RS422 / RS485 levels supported)
  • USB Device Port  As programming and monitoring port
  • USB Host port  Supports USB Memory drive
  • Ethernet Port  For connecting to a PLC, programming of  FlexiPanels®, a third party device, Drive or  remote monitoring (10 / 100 MBPS).
  • Type of LCD  Multicolor backlight / TFT Color Touch Screen
  • Supported Colors  32K for Color TFT LCD
  • Isolation  Isolation between communication and power   ports is 500 V DC for 1 Min.
  • Immunity to ESD  as per IEC61000-4-2
  • Immunity to Fast Transients  as per IEC61000-4-4
  • Immunity to Radiated electromagnetic field  as per IEC61000-4-3
  • Immunity to Conducted disturbances  as per IEC61000-4-6
  • Surge  as per IEC61000-4-5
  • Radiated emission  as per EN55011
Features
3 to 12.1 Graphical Touchscreen Multicolor / TFT Color Display

Floating point support, Bar graph, Built-in RTC

Ladder editor with powerful instruction set

Support for Recipes and 32K color Bitmaps for color LCD Models
Communication Ports:One / Two serial ports to connect PLC at RS232 / 422 / 485 levels / Printer / Programming PortOne USB (device) port as Programming PortOne USB (host) port to connect USB memory drive#One optional Ethernet port to connect PLC / Programming Port / Remote monitoring#
Dual Port communication supported for units with two serial ports
User defined Function keys to support various tasks
Data Logging, Transfer logged data on USB memory drive#
Trending (Real Time & Historical#)
Alarms (Real Time & Historical)
Multilanguage (Unicode) support with true type Windowsfonts
IP66 design. CE, UL approved. RoHS compliant
Common Programming software for the entire FlexiPanelsfamily.FREE!!

The FlexiPanelssupport Operator interface features. The user can also implement logic, specific to application using standard Ladder programming. A PLC logic block can be executed at power up, during every scan or upon a timer interrupt. The FlexiPanelsoperator interface functions revolve around Screens and Tasks that can be assigned to screens and application.

Function Keys
FlexiPanelsHMIs are also available with Touch Screen and Function keys. The Function keys also have built-in LEDs. The function keys are independent of Touch Screen. These function keys are screen dependent Function Keys. User can assign any application related task / actions to these function keys.

Touch Keys Task
Touch Keys in FlexiPanelscan be assigned Tasks for three instances: when the screen is touched, while the screen is touched and when the screen is released. Multiple tasks can be assigned to a touch key. In addition to above, tasks for data entry, alarm management etc. can be defined. These definitions allow Complete flexibility in cursor control and key operations when changing data.

Alarms
Real time and historical Alarms can be defined in FlexiPanels. User-friendly Alarm object can be defined on the display. Alarms can be real time or historical. Keys can be assigned to acknowledge Alarm, view and scroll.

Recipes
Recipes data is stored in the FlexiPanelsmemory. With one button stroke, a set of data can be downloaded to the PLC. Once in the local memory, the recipes data can be edited using simple data entry objects.

Bitmaps / Wizards
Different bitmaps can be embedded on the FlexiPanelsscreen. Transparent buttons can be used for data entry and set points on bitmap images. Bitmaps can be imported into the application and displayed on the FlexiPanelsscreens. In addition, several wizards are supported to create commonly used objects such as Analog meters, Lamps, Buttons and Bar graphs. 32K colors are supported for bitmaps.

Easy events logging and trend tracking
Touch Screen based FlexiPanelsmodels support data logging feature. A part of FlexiPanelsmemory can be allotted for data logging. Real time as well as Historical Trending is also supported. The user can also display multiple trends with different pen color on one screen.

Ladder Support
FlexiPanelssupport ladder functionality. User can define logic in the unit using FlexiSoftsoftware. The execution of ladder could be through communication port or through I/O. Only HMI version of FlexiPanelsalso support ladder functionality. It is used for critical applications where data is processed before sending it to controller. The execution of ladder logic is in microseconds. Ladder monitoring for debugging is also supported in FlexiPanelsconfiguration software.

Multilanguage / Unicode Support
All the languages are supported in the FlexiPanels. The user can now display messages, alarms in any regional / local language. All Windowsfonts can also be used for text in an application.

Communication Ports
FlexiPanelshave upto two serial communication ports. Both the ports can be used for programming of FlexiPanels, printing screens (alphanumeric data), connecting to third party serial devices (barcode readers, temp scanners etc.) or to connect to a PLC or drive. Dual port feature is supported for FlexiPanelsmodels having 2 serial ports. User can configure these serial ports to connect 2 different devices supporting different protocols, such as PLC / Drives / DCS / SCADA etc.

Ethernet Port
FlexiPanelssupport optional Ethernet port (Modbus TCP/IP). It can be used to connect to a PLC and monitor machine / process status from remote location. The Ethernet port can also be used for remote Program upload / download in FlexiPanels.

Configuration Software
FlexiSoftis a compact, Windowsbased software to configure the FlexiPanelsunits.
User friendly configuration tools and easy approach, helps user create applications quickly and easily.

Model Comparison

 Product   Model

Display

LCD Life
at 25oC
Key
/TS

Memory

PLC 
Steps

Screen 
Memory

Logging Memory

Serial 
Ports **

USB

Ethernet
Port

RTC Power
Consum-ption
Weight
(Approx.)
FP4030MT FP4030MT
-Rev0#
128x64 
3” Multicolor 
Backlight
30000 hrs No
/ Yes
Up-to
1.5 MB
5 k Up-to
1 MB
NA    2** Device No Yes 3W 156 gms.
FP4030MT
-Rev1
128x64 
3” Multicolor 
Backlight
30000 hrs No
/ Yes
Up-to
1 MB
24 k Up-to
312 KB
NA 2** Device No Yes 3W 156 gms.
FP4035 FP4035T 320x240 QVGA
3.5" Color TFT
50000 hrs 6
/ Yes
Up-to
8 MB
160 k Up-to
6 MB
Up-to
2 MB##
1 Device
and Host
No Yes 3W 275 gms.
FP4035TN 320x240 QVGA
3.5" Color TFT
50000 hrs 6
/ Yes
Up-to
8 MB
160 k Up-to
6 MB
Up-to
2 MB##
1 Device
and Host
Yes Yes 3W 275 gms.
FP5043 FP5043T 480x272 WQVGA
4.3” Color TFT
30000 hrs No
/ Yes
Up-to
128 MB
160 k Up-to
45 MB
Up-to
20 MB
   2** Device
and Host
No Yes 5W 320 gms.
FP5043TN 480x272 WQVGA
4.3” Color TFT
30000 hrs No
/ Yes
Up-to
128 MB
160 k Up-to
45 MB
Up-to
20 MB
   2** Device
and Host
Yes Yes 5W 320 gms.
FP4057 FP4057T 320x240 QVGA
5.7" Color TFT
60000 hrs 6
/ Yes
Up-to
8 MB
160 k Up-to
6 MB
Up-to
2 MB##
2 Device
and Host
No Yes 7W 690 gms.
FP4057TN 320x240 QVGA
5.7" Color TFT
60000 hrs 6
/ Yes
Up-to
8 MB
160 k Up-to
6 MB
Up-to
2 MB##
2 Device
and Host
Yes Yes 7W 690 gms.
FP5070 FP5070T 800x480 WVGA
7" Color TFT
30000 hrs No
/ Yes
Up-to
128 MB
160 k Up-to
45 MB
Up-to
20 MB
2 Device
and Host
No Yes 9W 610 gms.
FP5070TN 800x480 WVGA
7" Color TFT
30000 hrs No
/ Yes
Up-to
128 MB
160 k Up-to
45 MB
Up-to
20 MB
2 Device
and Host
Yes Yes 9W 610 gms.
FP5121 FP5121T 800x600 SVGA
12.1" Color TFT
70000 hrs No
/ Yes
Up-to
128 MB
160 k Up-to
45 MB
Up-to
20 MB
2 Device
and Host
No Yes 16W 1.680 Kg
FP5121TN 800x600 SVGA
12.1" Color TFT
70000 hrs No
/ Yes
Up-to
128 MB
160 k Up-to
45 MB
Up-to
20 MB
2 Device
and Host
Yes Yes 16W 1.680 Kg
















































































View Complete Details

FP3 Flexi Panels PC

4.3 to 10.2 TFT Color display with touch screen
Two serial communication interfaces (One RS232 and One RS232/RS485)

One USB programming port

One USB Host port
One Ethernet port
One SD card slot
Supports Horizontal and Vertical display orientation
High quality color display
Front Panel mounting with IP66 rating
Multilanguage support with true type Windows fonts
CE, UL Class I Div 2, RoHS
View Complete Details

LED Panel PC

10.1 WSVGA TFT LED Panel with Resistive Touchscreen
Embedded Intel Atom E3845 Processor, Quad-core, 1.91 Ghz
Supports one internal SATA 2.5 SSD/HDD and 1 mSATA port
System memory up to 8 GB DDR3L 1066/1333 SDRAM
Fanless design
RS-232/422/485 selectable through BIOS
Windows 7/8/10 support
View Complete Details

Keypad Based HMI Flexi Panels

  • Power  + 24V DC ±15%   FP4020 - 2 W Max  FP4030 - 3 W Max
  • Bezel  IP66 rated Keypad
  • Operating Temperature  0o to 50oC
  • Storage Temperature  -20o to 80oC
  • Humidity  10% to 85% (Non condensing)
  • Communication Port  One Serial Port  (RS232 / RS422 / RS485 levels supported)
  • USB Device Port  As programming and monitoring port
  • Type of LCD  Multicolor Backlight LCD
  • Isolation  Isolation between communication and power   ports is 500 V DC for 1 Min.
  • Immunity to ESD  as per IEC61000-4-2
  • Immunity to Fast Transients  as per IEC61000-4-4
  • Immunity to Radiated electromagnetic field  as per IEC61000-4-3
  • Immunity to Conducted disturbances  as per IEC61000-4-6
  • Surge  as per IEC61000-4-5
  • Radiated emission  as per EN55011
16 x 2 Text and 3.1 Graphical / Multicolor Backlight LCD Display

Floating point support, Bar graph, Built-in RTC

Ladder editor with powerful instruction set

Support for Recipes
Communication Ports:One serial port to connect PLC at RS232 / 422 / 485 levels / Printer / Progamming PortOne USB (device) port as Programming Port
User defined Function keys to support various tasks
Alarms (Real Time & Historical)
Multilanguage (Unicode) support with true type Windowsfonts for graphical model
IP66 design. CE, UL approved. RoHS compliant
Common Programming software for the entire FlexiPanelsfamily.FREE!!

The FlexiPanelssupport Operator interface features. The user can also implement logic, specific to application using standard Ladder programming. A PLC logic block can be executed at power up, during every scan or upon a timer interrupt. The FlexiPanelsoperator interface functions revolve around Screens and Tasks that can be assigned to screens and application.

Function Keys
FlexiPanelsHMIs are available with function keys and Numerical keypad for easy data entry. The Function keys also have built-in LEDs. These function keys are screen dependent Function Keys. User can assign any application related task / actions to these function keys.

Alarms
Real time and historical Alarms can be defined in FlexiPanels. User-friendly Alarm object can be defined on the display. Alarms can be real time or historical. Keys can be assigned to acknowledge Alarm, view and scroll.

Recipes
Recipes data is stored in the FlexiPanelsmemory. With one button stroke, a set of data can be downloaded to the PLC. Once in the local memory, the recipes data can be edited using simple data entry objects.

Bitmaps / Wizards
Different bitmaps can be embedded on the FlexiPanelsscreen (Graphical Model). Bitmaps can be imported into the application and displayed on the FlexiPanelsscreens. In addition, several wizards are supported to create commonly used objects such as Analog meters, Lamps, Buttons and Bar graphs.

Ladder Support
FlexiPanelssupport ladder functionality. User can define logic in the unit using FlexiSoftsoftware. The execution of ladder could be through communication port or through I/O. Only HMI version of FlexiPanelsalso support ladder functionality. It is used for critical applications where data is processed before sending it to controller. The execution of ladder logic is in microseconds. Ladder monitoring for debugging is also supported in FlexiPanelsconfiguration software.

Multilanguage / Unicode Support
All the languages are supported in the FlexiPanels(Graphical Model). The user can now display messages, alarms in any regional / local language. All Windowsfonts can also be used for text in an application.

Communication Ports
Function Keys based FlexiPanelshave one serial communication port. The serial port can be used for programming of FlexiPanels, printing screens (alphanumeric data), connecting to third party serial devices (barcode readers, temp scanners etc.) or to connect to a PLC or drive. User can configure serial port for Rs232 or RS485 communication.

Configuration Software
FlexiSoftis a compact, Windowsbased software to configure the FlexiPanelsunits.
User friendly configuration tools and easy approach, helps user create applications quickly and easily.

 Product   Model

Display

LCD Life
at 25oC
Key

Memory

PLC 
Steps

Screen 
Memory

Serial 
Ports

USB

RTC Power
Consumption
Weight
(Approx.)
 FP4020 FP4020MR 16x2 Text
Multicolor backlight
40000 hrs 18  Up-to
512 k
10 k Up-to
84 kB
1 Device Yes 2 W 172 gms.
 FP4030 FP4030MR 128x64 Graphical
Multicolor backlight
30000 hrs 18

Up-to
1.5 MB

10 k Up-to
1 MB
1 Device Yes 3 W 255 gms.






 


















View Complete Details

Gateway Protocol Converters

Features
DIN Rail or Panel Mounted compact Protocol Converter
DB9 Serial ports in any combination of RS232 / RS422 / 2 or 4 wire RS485 / CMOS
Connects PLC to PLC or PLC to a Modbus Network (as a Master or Slave)
Allows data sharing between PLC, Invertors, Controllers and other network devices
Common model for connecting different devices. Several PLC and Invertors supported
Direct connection to the Programming terminal saves additional hardware
Low power consumption of only 2.5 Watts
Common Programming software for the entire Gateway family.FREE!!
CE with UL certification
View Complete Details

Current Isolator

Features
DIN Rail or Panel Mounted compact Current Isolator
Isolated Input, Output and Power Supply (3 Port Isolation)
4-20 mA Input
4-20 mA isolated output
Output zero and span set by use of potentiometer
Additional isolated + 24V DC power source for loop powering
View Complete Details

LCD Flow Rate Indicator / Totalizer

Features
Compact 1 / 8 DIN size case
Two pulse and three control inputs
2 relays (NO) of 5 A and 250 V OR 2 Open Collector Outputs; 100 mA maximum
One 4-20 mA analog output
RS232 / RS485 port for serial communication and printing
Password security for function keys
+24 VDC unregulated O/P for AC powered unit
NVRAM to retain data on power failure
Both inputs can have up-to 16 points linearizing K factor
View Complete Details

RS485 Signal Converters / Repeaters

  • Mounting DIN rail or back panel mounting
  • Power + 24 VDC ± 10 %, 2.0 watts max
  • Communication Ports Two Ports as Follows:
  • COM1 COM2 RS422 / RS485 RS422 / RS485
  • Power, Port Isolation: 1 KV Isolation between communication ports and Power supply, through DC-DC coupler.
  • Data Rates Upto 115.2 kbps.
  • Distance Unit transmits data up to 4000ft (1200m)
  • Temperature Operating : 0o to 60o C Storage : -40o to 90o C
  • Humidity 10% to 90% (Non condensing)
  • Dimensions (DIN rail) 101mm (L) X 40mm (D) X 51mm (W) (DIN RAIL mounting)
  • Weight 125 gm approx.
  • Certifications CE / UL
  • Immunity to ESD Level 3 as per IEC 1000-4-2
  • Immunity to Transients Level 3 as per IEC 1000-4-4
  • Immunity to Radiated RF Level 3 as per IEC 1000-4-3
  • Immunity to Conducted RF Level 3 as per IEC1000-4-6
  • Emissions EN55011 CISPR A
Features
DIN rail or panel mounted compact Repeater
External powered design
Isolation of power and communication ports
Automatic detection of communication baud rate
Automatic control of transreceiver direction
Easy to use plug and play device (no configuration software required)
CE / UL certification

RS485 communication levels can physically support 32 nodes up-to a maximum distance of 1200 mtrs. CNV-03-B is a RS422 / RS485 repeater. CNV-03-B unit is used where more than 32 nodes are to be connected in the RS485 network or the distance between two nodes is more than 1200 mtrs. It increases number of nodes connected in RS485 network. One CNV-03-B can increase maximum 32 nodes in the network. Multiple CNV-03-B units can be used to support maximum 255 nodes in one network.

CNV-03-B has 2 communication ports. Both the communication ports are screw type easy to use connectors. Communication ports as well as power port are isolated. CNV-03-B supports both 2 wire / 4 wire RS485 and RS422 configuration. It has switch settings to select 2 wire / 4 wire communication on each COM port.w

CNV-03-B operates on 24 VDC external supply.

View Complete Details

Universal Signal Converters / Repeaters

  • Mounting DIN rail or back panel mounting
  • Power + 24 VDC ± 10 %, 2.0 watts max  (for externally powered model)
  • Communication Ports Two Ports as Follows:
  • COM1 COM2 RS232 / CMOS RS422 / RS485
  • Temperature Operating : 0o to 60o C Storage : -20o to 80o C
  • Data Rates Upto 115.2 kbps.
  • Distance Externally powered units transmit data upto 4000 ft (1200 m). Less with port powered model.
  • Temperature Operating: 0° to 60° C Storage: - 40° to 90° C
  • Humidity 10% to 90% (Non condensing)
  • Dimensions (DIN rail) 101mm(L) X 40mm (D) X 51mm(W)
  • Weight 125 gm approx.
  • Certifications CE / UL
  • Immunity to ESD Level 3 as per IEC 1000-4-2
  • Immunity to Transients Level 3 as per IEC 1000-4-4
  • Immunity to Radiated RF Level 3 as per IEC 1000-4-3
  • Immunity to Conducted RF Level 3 as per IEC1000-4-6
  • Emissions EN55011 CISPR A
Features
DIN rail or panel mounted compact Converter
Port powered or external powered design
Isolation of power and communication ports
Automatic detection of communication baud rate
Automatic control of transreceiver direction
Easy to use plug and play device (no configuration software required)
CE / UL certification
View Complete Details

RDIO Remote Digital I/O Modules

  • Digital Inputs 3 to 30 V DC / AC High 0 to 1.5 V DC / AC Low
  • Digital Outputs: Open Collector Relay (NO or NC) 50 V DC, 0.25 Amp. max. 230 V AC, 2Amp.
  • Power Supply 24 V DC ± 10%
  • Communication: COM1 COM2 To Programming terminal / Operator interface / Eagle I/O / RDIO To PLC or as Modbus Slave
  • Temperature: Operating Storage 0o to 60o C -20o to 80o C
  • Humidity 10% to 90% (Non condensing)
  • Mounting DIN rail or back panel mounting
  • Dimensions (DIN rail) 155 X 102 X 48 mm
  • Immunity to ESD Level 3 as per IEC 1000-4-2
  • Immunity to Transients Level 3 as per IEC 1000-4-4
  • Immunity to Radiated RF Level 3 as per IEC 1000-4-3
  • Immunity to Conducted RF Level 3 as per IEC1000-4-6
  • Emissions EN55011 CISPR A
Features
DIN rail or panel mounted compact Digital I/O module
Direct connection to PLC programming port
Direct connection as Modbus Slave on RS485 network or RS232 link
Up-to 32 digital inputs and 32 digital outputs
Dual serial ports for connection of programming terminal / Operator Interfaceor SCADA
LED indication for each I/O
Diagnostic indication for communication and power
Common programming software for the entire RDIO family.FREE!!
CE marked with optional UL certification
Basic RDIO Operations
FunctionThe RDIO series products add digital capability to your PLC / SCADA. Models are available that offer upto 32 digital inputs and upto 32 digital outputs to the PLC / SCADA. The configurationis done using the setup software.
The digital inputs and outputs are isolated from the host device. RDIO has two communication ports. One port is used to connect to the PLC and second port can be used to connect an Operator Interface such as one of the Prizm series products or an IBM PC to configure the RDIO. The communication between the RDIO and PLC is optimized for speed to allow fastdata transfer.

PLC CommunicationThe setup software defines the block of PLC registers used for communication. Register words are used for tracking inputs and outputs. Data is either sent to the specified register in the PLC or received from the register designated as Output register.
The unit scans PLC registers continuously and evaluates the outputs.

RTU ModeThe RDIO can also be configured as Modbus RTU useful for data acquisition. The Modbus protocol allows the user to use off the shelf SCADA software such as ASTRA and other host devices. The unit offers RS232 as well as RS485 hardware layers.

Digital I/OsThe I/Os are isolated and in case of outputs separate ground can be made available for each output. The Unit has LED indication for each I/O.The unit is configured using the Windows based setup software. This will define the desired parameters for the unit like the inputs and outputs to be used, PLC registers, etc.
View Complete Details

Touch Screen HMI PLC Operator Panel

  • Power + 24V DC ± 10%
  • Bezel IP 65 rated Touch Screen
  • Operating Temp. 0o to 50o C
  • Storage Temp. -20o to 80o C
  • Humidity 10% to 85% (Non-condensing)
  • Communication Ports Two serial ports.  (RS232/RS422/RS485/CMOS Levels supported)
  • Immunity to ESD as per IEC61000-4-2
  • Immunity to Fast Transients as per IEC61000-4-4
  • Immunity to Radiated electromagnetic field as per IEC61000-4-3
  • Immunity to Conducted disturbances as per IEC61000-4-6
  • Surge as per IEC61000-4-5
  • Radiated emission as per EN61000-6-4
Features
All features of Prizm Touch ScreenOperator Interfaces
Integrated Digital Inputs and Outputs with optional Analog I/O
Digital Inputs and Outputs rated for 24 V DC
Analog Inputs for RTD, mV and mA. Analog Outputs are 4-20 mA / 0-10 VDC
Inputs connectable to PLC or used for internal program
Support for Ladder Logic and Analog control
High Speed Counters and Timers

Two Communication Ports:Universal serial ports to connect PLC / Printer / Programming Port

Data Logging, Trending (Real Time & Historical), Alarms (Real Time & Historical)
Built-in PID, PWM functionality
Multilanguage (Unicode) support with true type Windows fonts

IP65 design. CE and UL certified

Basic HIO Operations
The HIO units possess both Prizm (Operator interface) as well as programmable logic features. The user can implement logic, specific to application using standard Ladder programming. The HIO unit has four 32-bit High Speed Counters (Normal and Quadrature Mode), Rate measurement capability (max. up to 25kHz), Timers and Counters, Internal Coils, retentive and non-retentive memory and PID functionality. A PLC logic task can be programmed for continuous scanning, or only when a specific screen is showing. The HIO operator interface functions revolve around Screens and Tasks that can be assigned to screens and application. The HIO can also display an Alarm conditions.
Supported Tasks are listed below:

Go to ScreenGo to Next ScreenGo to Previous ScreenWrite value to TagAdd a constant value to TagSubtract a constant value form TagAdd Tag B to Tag ASubtract Tag B to Tag ATurn Bit OnTurn Bit OffToggle BitCopy Tag B to Tag ASwap Tag A and Tag B Print DataSet RTCCopy Tag to STRCopy Tag to LEDDelayWaitCopy Prizm block to Prizm / PLC blockCopy Prizm/PLC block to PrizmblockCopy RTC to PLC blockExecute PLC Logic block

Digital I/OHIO Touch Screens can have up to 28 digital inputs and 16 digital outputs on the unit. Digital inputs are high impedance 24 VDC and outputs are relay (NO), transistor outputs or a combination of both. The Digital I/O capability of HIO units can be expanded using external add on I/O Modules.

Analog I/OThe HIO controllers can have up to 4 universal analog inputs and 2 analog outputs. Analog inputs are mA, mV and RTD. The Analog outputs are 4-20 mA or 0-10 VDC. Analog I/O capability of HIO units can be expanded using external add on I/O Modules.

PIDThe built-in PID controller can process 12 independent inputs in addition to the Analog inputs of the unit. The input to the PID controller is a data register, which can hold an analog input or any other value.

High Speed Counters
HIO Touch Screens support High Speed Counter inputs. These High Speed Counter inputs can be used for applications such as Rate Measurement, Speed Measurement, Totalizer, etc. The user can define upto 4 High Speed inputs. HIO units also support Quadrature Pulse input.

PWM
HIO Touch Screens support Pulse Width Modulation output. PWM is used for applications such as Motion Control. The user can control the fixed number of Pulses that are to be sent to drives.

Touch Keys TaskTouch Keys in HIO units can be assigned Tasks for three instances: when the key is pressed , while the key is pressed and when the key is released. Multiple tasks can be assigned to a key. In addition to above, tasks for data entry, alarm management etc. can be defined. These definitions allow complete flexibility in cursor control and key operations when changing data.
Alarms
Real time and historical alarms can be defined in HIO Touch Screens. User-friendly alarm object can be defined on the display. Alarms can be real time or historical. Keys can be assigned to acknowledge alarm, view and scroll.

Screens
Up to 65535 screens can be defined in HIO Touch Screens. Screen Tasks can be assigned before showing a screen, while showing a screen and after hiding a screen. Various types of objects such as plain text objects, Data display (coil status, register value, register dependent text), Data entry objects and Alarm objects etc can be defined. Data entry objects can have limits and math associated. Floating point data entry is supported.

Multilanguage / Unicode Support
All the languages are supported in the HIO Touch Screens. The user can now display messages, alarms in any regional language. All Windows fonts can also be used in an application.

Communication Ports:
RS232 - RS422 / RS485 / CMOS Ports: HIO Touch Screens have two serial communication ports. Both the ports can be used for programming of HIO unit, printing screens, connecting to third party serial devices (barcode readers, printers etc.) or to connect to a PLC or drive. User can connect two masters simultaneously on these ports.

Configuration SoftwarePrizm Setup Software is a compact, Windows based software to configure the HIO Series Interfaces. Prizm configuration tools and easy approach, can help you create your applications quickly and easily. Whether you need a small application to monitor data or a bigger application for both monitoring and control, Prizm Setup Software has it all.

To get started with HIO you need:1. HIO unit2. Prizm Setup Software3. IBM Cable (Part codes: IBM 0909-1-00 or IBM 0925-1-00)

System requirements for Prizm Setup Software are:
Windows Version : Microsoft Windows 2000 or aboveProcessor : 266 MHz PENTIUM or higherMouse : RequiredRAM : 64 MB or moreDisplay resolution : 800 x 600 (VGA) or betterDisplay colors : 256 colors or moreSerial Port : 1 serial port for HIO programmingKeyboard : Required

Analog Outputs:
Current / Voltage

4-20 mA , 0-10V
Digital Inputs: 

  

Rated Input Voltage -
                                                          For Normal Input                     For High Speed
1) Rated Input Voltage                       24VDC (Max is 28VDC)              24VDC (Max is 28VDC)
2) Input Impedance                                      4.7k                                            2.3k


Logic '0' Voltage 0 to 5V
Logic '1' Voltage 14 to 28V


Rated Input Current (At 24VDC) -

                                                        For Normal Input 
                    For High Speed
Rated Input Current                                    4.89mA                                       10mA

Digital Outputs (Open Collector):
Maximum Load current
Voltage drop at ON

300 mA (for NPN) and 500 mA (for PNP)
0.4V or less
Digital Outputs (Relay):
Relay Rating

230V AC, 2 Amp. (max)























View Complete Details

Analog IO Module

Low cost compact Analog IO modules with DIN rail mounting Programmable inputs allow same modules to accept RTD, Thermocouple, mA, mV and Volts 12 bit resolution 4 universal analog inputs and 2 analog outputs High Speed Modbus RTU (Slave) communication
View Complete Details

Keypad Based Operator Panels Prizm

  • Power  + 24V DC ± 10%, 3W maximum (or 5 V DC PLC Powered)
  •  Bezel  IP 65 rated keypad
  •  Operating Temp.  0o to 50o C *
  •  Storage Temp.  -20o to 80o C
  •  Humidity  10% to 90% (Non-condensing)
  •  Communication  Two communication ports, one for connecting to the PLC and   other for programming / serial printing.
  •  Immunity to ESD  as per IEC61000-4-2
  •  Immunity to Fast Transients  as per IEC61000-4-4
  •  Immunity to Radiated  electromagnetic field  as per IEC61000-4-3
  •  Immunity to Conducted  disturbances  as per IEC61000-4-6
  •  Surge  as per IEC61000-4-5
  •  Radiated emission  as per EN61000-6-4

Part Number

Description

Datasheet

Prizm-10

PZM-10-5-B

16 X 2 Display, 6 Function Keys, Printer Port, 5 V DC PLC Powered, Black Case, 24K memory

PZM-10-5-Y-B

16 X 2 Display, 6 Function Keys, Printer Port, 5 V DC PLC Powered, RTC, Black Case, 24K memory

PZM-10-24-B

16 X 2 Display, 6 Function Keys, Printer Port, 24 V DC Power Supply, Black Case, 24K memory

PZM-10-24-Y-B

16 X 2 Display, 6 Function Keys, Printer Port, 24 V DC Power Supply, RTC, Black Case, 24K memory

Supported tasks

Go to Screen Go to Next Screen
Go to Previous Screen Write Value to a Tag
Add a constant to tag Subtract a Constant from Tag
Add Tag B to Tag A Subtract Tag B from Tag A
Turn Bit On Turn Bit Off
Toggle Bit Copy Tag B to Tag A
Swap Tag A and Tag B Print Data
Set RTC Copy Tag to STR
Copy Tag to LED Delay
Wait Copy Recipe Block to PLC Block
Copy PLC Block to Recipe Block Execute PLC Logic Block.

Prizm screens can be triggered by the PLC or by the tasks supported in Prizm32 Software. Various text or graphic objects can be placed on the screen to allow the operator to monitor the machine. Keys are used to navigate through screens or to edit data. A tag database defines the PLC bits / registers used for monitoring or controlling. Bits and registers internal to the unit itself can also be used.

Tasks:The unit can be configured to execute various tasks at power up and in every scan or when a particular screen is active. Different set of tasks can also be defined when a key is pressed, while it is held down and when a key is released. The list of possible tasks contains powerful commands to navigate through screens; monitor, control and manipulate tags as well.

Alarms:Upto 256 alarms (16 for text models) can be defined. As the alarms are triggered they are placed in an alarm container and can be displayed on the screen. Keys can be defined to acknowledge the alarms and to navigate through alarm list. An acknowledged inactive alarm is taken out of the alarm container.

Screens:Screen Tasks can be defined to be executed before showing a screen, while showing a screen and after hiding a screen. Objects such as plain text objects, Data display (coil status, register value, register dependent text), Data entry objects, Alarm objects etc. can be defined on the screen.

Configuration Software:Prizm units are configured using the Prizm32 software. With the Prizm32 software, the user can configure Prizm settings (for example keypad queue size, float data format, printer port, number oflanguages supported etc.), Nodes (PLCs to be connected to the unit and the communication settings for the port), Tag database (Prizm local memory tags as well as the PLC bits and registers to be used by the application), Alarms (the registers used to trigger alarms, text for alarms and other alarm settings), Keys (the tasks to be performed when a key is pressed or released) and the Tasks to be performed when the unit powers up as well as global tasks.
Screens are configured as per the desired user interface. Here, the screen objects (text and graphic objects), wizards, reassigning tasks to keys for that particular screen, tasks to be performed when the screen is triggered, while the screen is displayed and when it is replaced with another screen are defined.
After configuring, the application can be saved for future use. This application is then downloaded to the Prizm unit.
View Complete Details

HIO Keypad Based HMI PLC Flexi Panels

  • Power + 24V DC ± 10%
  • Bezel IP 65 rated keypad
  • Operating Temp. 0o to 50o C
  • Storage Temp. -20o to 80o C
  • Humidity 10% to 90% (Non-condensing)
  • Communication Two communication ports. (User configurable)
  • Immunity to ESD as per IEC61000-4-2
  • Immunity to Fast Transients as per IEC61000-4-4
  • Immunity to Radiated electromagnetic field as per IEC61000-4-3
  • Immunity to Conducted disturbances as per IEC61000-4-6
  • Surge as per IEC61000-4-5
  • Radiated emission as per EN61000-6-4
  • Analog Inputs: Voltage Current RTD  0-100 mV, 0-50 mV 0-20 mA, 4-20 mA 3-wire RTD (Alpha1, Alpha2)
Features
All features of Prizm LCD Operator Interfaces
Integrated Digital Inputs and Outputs with optional Analog I/O
Digital Inputs and Outputs rated for 24 V DC
Analog Inputs for RTD, mV and mA. Analog Output is 4-20 mA
Inputs connectable to PLC or used for internal program
Support for Ladder logic and Analog control
High Speed Counters and Timers
Dual Port Support for connecting to a PLC / Printer / SCADA / Drive
Common Programming software for the entire HIO family.FREE!!
IP65 design. CE and UL certified

Basic HIO OperationsThe HIO unit has Prizm (Operator interface) as well as programmable logic features. The user can implement logic, specific to application using standard Ladder programming. The HIO unit has four 32-bit High Speed Counters(Normal and Quadrature Mode), Rate measurement capability (max. up to 25kHz), Timers and Counters, Internal Coils, retentive and non-retentive memory and PID functionality. A PLC logic task can be programmed for continuous scanning, or only when a specific screen is showing. The user can also include a Programmable logic task in power on as well as Global task. The HIO operator interface functions revolve around Screens and Tasks that can be assigned to keys, screens and application. The HIO can also display an Alarm conditions.Supported Tasks are listed below:

Go to ScreenGo to Next ScreenGo to Previous ScreenWrite value to TagAdd a constant value to TagSubtract a constant value form TagAdd Tag B to Tag ASubtract Tag B to Tag ATurn Bit OnTurn Bit OffToggle BitCopy Tag B to Tag ASwap Tag A and Tag B Print DataSet RTCCopy Tag to STRCopy Tag to LEDDelayWaitCopy Prizm block to Prizm / PLC blockCopy Prizm/PLC block to PrizmblockCopy RTC to PLC blockExecute PLC Logic block


Digital I/OThe HIO Keypad series can have up to 16 digital inputs and 12 digital outputs on the unit. Digital inputs are high impedance 24 V DC and outputs are either relay (NO), open collector or a combination of both. The Digital I/O capability of HIO units can be expanded using external add on I/O Modules.

Analog I/OThe HIO controllers can have up to 4 analog inputs and 2 analog outputs. Analog inputs are mA, mV and RTD. Analog outputs are 4-20 mA. The Analog I/O capability of HIO units can be expanded using external add on I/O Modules.

PIDThe built-in PID controller can process 12 independent inputs in addition to the Analog inputs of the unit. The input to the PID Controller is a data register, which can hold an analog input or any other value.

Keys TaskKeys in HIO can be assigned Tasks for three instances: when the key is pressed , while the key is pressed and when the key is released. Multiple tasks can be assigned to a key. Also different screens can have different key definitions. In addition to above-mentioned tasks, Keys specific tasks can be defined for keys. These include tasks for data entry, alarm management etc. These definitions allow complete flexibility in cursor control and key operations when changing data.

ScreensUp to 65535 screens can be defined in HIO. Screen Tasks can be assigned before showing a screen, while showing a screen and after hiding a screen. Various types of objects such as plain text objects, Data display (coil status, register value, register dependent text), Data entry objects and Alarm objects can be defined on screen. Two screens can be associated to avoid duplication of screens and objects.Data entry objects can have limits and math associated. Various types of data formats are available which help the user to edit data easily. Floating Point data entry is supported.

AlarmsAlarms can be defined in HIO. Alarms can either be consecutive or discrete. User-friendly alarm object can be defined on the display. Alarms can be real time or historical. Keys can be assigned to acknowledge alarm, view and scroll.

Dual Port SupportHIO units (except HIO010) have two communication ports. Both ports can be configured as RS232, CMOS, RS485 / RS422 programming port or to connect a Printer / PLC / SCADA / Drive etc. Drivers can be downloaded in HIO units for Dual Port application

Configuration SoftwarePrizm Setup Software is a compact, Windows based software to configure the HIO Series Interfaces. Prizm configuration tools and easy approach can help you create your applications quickly and easily. By using Prizm Setup Software features, you can be more effective in presenting your application. Whether you need a small application to monitor data or a bigger application for both monitoring and control, Prizm Setup Software has it all.

To get started with HIO you need:1. HIO unit2. Prizm Setup Software3. IBM Cable (Part codes: IBM 0909-1-00 or IBM 0925-1-00)System requirements for Prizm Setup Software are:Windows Version : Microsoft Windows 2000 or aboveProcessor : 266 MHz PENTIUM II or higherMouse : RequiredRAM : 64 MB or moreDisplay resolution : 800 x 600 (VGA) or betterDisplay colors : 256 colors minimumSerial Port : 1 serial port for HIO programmingKeyboard :Required

View Complete Details

Energy Measurement Module

  • Power : +10 to +30 VDC
  • Communication Port : 2 wire RS485
  •   Number of inputs
  • 4 Rated Input Voltage
  • 24 VDC (Max : 28 VDC) Input Impedance
  • 5.6 kW Rated Input Current
  • 4 mA Logic ‘0’ Voltage 
  • 0 to 5 VDC Logic ‘1’ Voltage
  • 12 to 28 VDC  
  • Number of Inputs 3 phase alternating current and voltage input
  •   Single Phase Voltage
  • +/-3.45V  ( i.e. 1.5 % of rated voltage 230 V ) Current
  • +/- 2 % of Full Scale 5A * CT ratio.   Active Power
  • +/- 2 % of Full Scale  ( 230V * 5A * CT ratio ) Measurable Frequency range
  • 40Hz to 70Hz  
  • Number of Outputs 4 (NPN Transistor)
  • Maximum Load current 500 mA
  • Voltage drop during Power ON 0.4 V or less
  •   Operating
  • 0° to 60° C Storage
  • -20° to 80° C Humidity
  • 10% to 90% (Non condensing) Mounting
  • DIN rail mounting Size
  • 100 W x 70 H x 35 D mm Immunity to ESD
  • Level 3 as per IEC1000-4-2 Immunity to Transients
  • Level 3 as per IEC1000-4-4 Immunity to Radiated RF
  • Level 3 as per IEC1000-4-3 Immunity to Conducted RF
  • Level 3 as per IEC1000-4-6 Emissions
Features

Low cost compact 3 phase Energy measurement module

3 phase voltage input up to 300 Vrms (Line-Neutral) and current input up to 5 A can be measured

Measures Voltage, Current, Frequency, Active Power, Reactive Power, True Power, Average Power and Power Factor

Facility for 4 bi-directional digital inputs and 4 digital NPN outputs (open collector)

High Speed Modbus RTU (Slave) communication

2 wire RS-485 Communication port (isolated) on pluggable terminal block

User definable Address, Baud rate and Parity through convenient DIP Switches

LED indication for each Input and Output, COM port and Power ON

No configuration software required

FunctionFIOD-EN-0404-C measures 3 phase Energy and adds digital capability to a PLC / SCADA system.The module has 3 phase isolated Voltage and Current inputs . It also has 4 digital inputs and 4 digital outputs that can be read and controlled by the Modbus master. The digital inputs and outputs are isolated from the host device. The module has one RS485 (2 wire) communication port to connect to the host device. Communication settings like baud rate, parity and station ID can be set by DIP switches.

Communication with HostThe module supports Modbus RTU (Slave) Protocol. It communicates with the Host through 2 wire RS 485 Network. In case of communication failure with Host, the user can configure watchdog time-out and failure mode for the outputs.

View Complete Details

FIOA Field Analog I/O Modules

  • Power  + 24V DC ± 10%, 4W maximum
  • Operating Temp.  0º to 50º C
  • Storage Temp.  -20º to 80º C
  • Humidity  10% to 90% (Non Condensing)
  • Mounting  DIN rail or back panel mounting
  • Dimensions  100 W x 70 H x 35 D mm
  • Immunity to ESD  as per IEC61000-4-2
  • Immunity to Fast Transients  as per IEC61000-4-4
  • Immunity to Radiated electromagnetic field  as per IEC61000-4-3
  • Immunity to Conducted disturbances  as per IEC61000-4-6
  • Surge  as per IEC61000-4-5
  • Radiated emission  as per EN61000-6-4
  • Communication Port     2 wire RS485, RS232, CMOS logic  Signals are available on RJ45 comm   port.  Same two wire RS485 signals are  provided on terminal block
  • Driver  Modbus RTU Slave
  • Baud rate     9600, 19.2k, 57.6k or 115.2k  (software configurable)
  • Parity  Odd, Even or None (software configurable)
  • Device ID  1-255 (Software configurable)
  • Isolation 1.5KV isolation between communication ports, I/O and power supply section.
  • Device   Minimum
  • IBM compatible PC with Pentium processor 266 MHz Pentium® II or higher Pentium compatible CPU
  • Operating System Windows® 2000 and above (except Windows® Vista)
  • System RAM    At least 64 megabytes (MB) of RAM
  • Hard disk 150 MB free memory space  
  • VGA Monitor Color settings Resolution 800x600 with 24 bit true color  
  • Mouse Microsoft® mouse or compatible pointing device
Features
Low cost compact Analog I/O modules with DIN rail mounting
Programmable inputs allow same modules to accept RTD, Thermocouple, mA, mV and Volts

12 bit resolution
4 universal analog inputs and 2 analog outputs
High Speed Modbus RTU (Slave) communication
User definable Address, Baud rate and Parity through Software Configuration
2 wire RS485 port provided on pluggable terminal block
Can be multi dropped as Modbus Slave on RS485 Network
Indication for Diagnostics, Power and Communication
Programming through standard Prizm software .FREE!!
CE marked with optional UL certification

Specifications

For mVolt inputs :
Uses 0-100 mV input range resolved in 12 bits.Total error : 0.2% of scale 1 bit.
For Current inputs :
Uses 0-20mA input range with 4.7Wprecision shunt resolved in 12 bits.Total error : 0.2% of scale 1 bit.
For Volt inputs :
Uses 0-10V, 1-5V input range resolved in 12 bits.Total error : 0.2% of scale 1 bit.

For RTD input :
Uses 3 wire compensation technique. Excitation Current is 0.5mA.Power dissipated in RTD is 0.025mW @ 100W.Range supported : -200 to 850oC.
For Thermocouple Input :
Uses 0-100mV input range resolved into 12 bits.Cold junction error is 1omaximum and 0.5otypical.Total error : 0.5% of scale 1 bit + CJC errorResponse Time : Worst case 25mSec approx.Temperature Drift(for Digital Count) : 60 PPMNormalization Factor : 0-99 (Software configurable)

Basic FIOA Operations
FIOA 0402 U is Analog Input Output Model having 4 Universal Analog inputs and 2 Analog outputs. The Analog inputs can be Voltage (0-10V, 1-5V), Current (020 mA, 420 mA), mV(0100 mV, 050 mV), RTD ( PT 100 Alpha1 and Alpha2 constant ), Thermocouple ( B, R, S, E, J, K, N, T ).
Each input channel can be configured independently to work as any of the above type as per configuration made in the PRIZM software. The Analog outputs can be Voltage (010 V) or Current (420 mA). Output channels also are software configurable to current or voltage.Unit supports standard Modbus RTU (slave) protocol for communicating with master device.
Analog inputs and outputs are isolated from the communication port . The power supply is isolated from all internal circuitry. Input and Output channels of the FIOA are user configurable and any combination of input types is possible. Prizm Setup Software helps the user to configure the FIOA units and use them as per his requirements.

1 bit Corresponds to
J -50 to 1200º C 0.43º C
K -50 to 1373º C 0.61º C
E -50 to 1000º C 0.32º C
R -50 to 1769º C 2.04º C
S -50 to 1769º C 2.31º C
B 0 to 1820º C 3.21º C
N -50 to 1300º C 0.7º C
T -50 to 400º C 0.47º C

 

Analog Outputs
Resolution 12 Bit
Load:
4-20 mA 
0-10 V DC  
Less than 500 W
Minimum 1K W



View Complete Details

FIOD Field Digital I/O Modules

  • Rated Input Voltage 24 VDC (Max is 28VDC)
  • Input Impedance 5.6 k
  • Rated Input Current 4mA
  • Logic ‘0’ Voltage 0 to 5V
  • Maximum Load current 500 mA
  • Power Supply +24 V DC ± 10%
  • Communication Port: 2 Wire RS485
  • Digital Inputs : Logic ‘1’ Voltage 12 to 28V
  • Digital Outputs (Transistor) Voltage drop at ON 0.4V or less 
  • Digital Outputs (Relay) Relay Rating 230V AC, 2 Amp. (Max.)
  • Temperature: Operating Storage 0o to 60o C -20o to 80o C
  • Humidity 10% to 90% (Non condensing)
  • Mounting DIN rail mounting
  • Dimensions (DIN rail) 100W X 70H X 35D mm
  • Immunity to ESD as per IEC61000-4-2
  • Immunity to Fast Transients as per IEC61000-4-4
  • Immunity to Radiated electromagnetic field as per IEC61000-4-3
  • Immunity to Conducted disturbances as per IEC61000-4-6
  • Surge as per IEC61000-4-5
  • Radiated emission as per EN61000-6-4
  • Isolation 1.5KV isolation between communication ports, I/O and power supply section.
  •    
Features
Low cost compact Digital I/O modules with DIN rail mounting
2 wire RS 485 port provided on pluggable terminal block
User definable Address, Baud rate and Parity through DIP Switch
High Speed Modbus RTU (Slave) communication
LED indication for each Input and Output , COM Port and Power ON
No configuration software required
Relay and Transistor outputs available
CE marked with optional UL certification
Basic FIOD Operations
FunctionThe FIOD series products add digital capability to PLC / SCADA. Models are available that offer upto 16 digital inputs and upto 16 digital outputs.The digital inputs and outputs are isolated from the host device. FIOD has one RS 485 (2 Wire) communication port to connect to host device.Communication settings like baud rate, parity and station ID can be set by DIP Switch.
Communication with HostFIOD module supports Modbus RTU (Slave) Protocol. The communication can be done with Host through 2 wire RS 485 Network.In case of communication failure with Host, all the outputs are switched OFF.

Modbus Registers MappingThere are 128 Modbus registers supported in FIOD. Out of which, 64 are input registers (1 to 64) which are mapped to input coils 1 to 1024. FIOD has 64 output registers (65 to 128) which are mapped to output coils 1025 to 2048.First 16 coils from 1 to 16 are assigned for FIOD inputs (1 to 16).Coils from 1025 to 1040 are assigned for FIOD outputs (1 to 16).
Modbus Mapping of Registers and Coils are mentioned below :

Sr. Register Range Modbus ModbusNo. /Coil Mapping Tag Length

1. Input Register 1-64 40001-40064 2 -bytes2. Output Register 65-128 40065-40128 2 -bytes3. Input Coil 1-1024 00001-01024 1-bit4. Output Coil 1025-2048 01025-02048 1-bit

View Complete Details

Eagle Analog I/O Modules

  • Power + 24V DC ± 5%, 3.5W maximum
  • Operating Temp. 0º to 50º C
  • Storage Temp. -20º to 80º C
  • Humidity 10% to 90% (Non Condensing)
  • Mounting DIN rail or back panel mounting
  • Dimensions Eagle-0404, Eagle-800 Eagle-0201-0302 155 mm x 102 mm x 48 mm 94 mm x 42 mm x 47 mm
  • Immunity to ESD 8kV Air, 6kV contact as per IEC 61000-4-2
  • Transient Immunity 2kV as per IEC61000-4-4
  • Radiated Immunity 10V / meter as per IEC61000-4-3
  • Emission As per EN55011 CISPR A
  • Isolation Analog section isolated from digital. No isolation between channels.
  • IBM Port Connects to PC for application download or operator interface for Pass-through.
  • PLC Port Connects to PLC
  • Response Time Depends on driver (Typical 200 mSec / Channel)
Features
DIN Rail or Panel mounted compact I/O modules
Indication for Diagnostics, Power and Communication
Adds I/O capability to your PLC, SCADA and Modbus networked devices
Programmable inputs allow same modules to accept RTD, mA, mV
12 bit 8 universal analog inputs or with 4 Universal Analog inputsand 04 analog outputs
Direct connection to PLC programming terminal with support for most PLCs
Can be multidropped as Modbus Slave on RS485 Network
Common Programming software for the entire Eagle family.FREE!!
CE marked
Specifications

For Voltage inputs
Uses 0-100 mV input range resolved in 12 bit.For higher input ranges, use externally calibrated shunt or contact factoryTotal error: 0.1% of scale 1 bit.

For Current inputs
Uses 0-20 mA input range with 5 ohms precision shunt resolved in 12 bit.Total error: 0.1% of scale 1 bit.

For RTD input
Uses 3 wire compensation technique. Current sense is 0.5mA Max.Power dissipated in RTD is 0.025 mV @ 100 ohms.Range supported: -200 to 850C

For Thermocouple input
Uses 0-100 mV input range resolved in to 12 bit for positive input and resolvedin 11 bit for negative inputs.Cold junction error is + 1 maximum and 0.5 typical.Total error: 0.5% of scale 1 bit + CJC error

Basic Eagle Operations
Eagle units accept universal field inputs (such as RTD, T/C, mA, and mV) and convert them to actual field values like temperature, pressure etc. before sending them to the PLC. Similarly it can also read values in PLC registers and scale the 4-20mA output accordingly.
Input and Output channels of Eagle are user configurable and any combination of input types is possible. Eagle Setup Software helps the user to configure the Eagle units and use them as per his requirements.
Linearisation: 16 point linearisation is provided for mV and mA inputs, which helps the user to convert non-linear segments into required engineering value.
Eagle units have two Communication Ports. Port1 (RS232/485) is connected to PLC and Port2 acts as Programming or Slave Port. Any Prizm model can be connected on Port 2 as a HMI.
Items required for Eagle configuration:
Eagle unit
+ 24V DC regulated power supply
IBM Cable (Part codes: IBM 0909-1 or IBM 0925-1)
Eagle Setup Software
Eagle to Device cable
System requirements for Eagle Setup Software are:
Window version - Microsoft Windows 3.1 or higher
Processor - 386 or higher
Hard Disk Space - 3 MB or more
Mouse - Required
RAM - 2 MB or Higher
Display Resolution - 640 x 480 (VGA) or better
Display colors - 16 colors or more

Model Analog Inputs Analog Outputs Digital Inputs Digital Outputs Part Number


Eagle-0201#

2 Universal 1 (4-20 mA) 3 2 Eagle-0201-0302-U

  
Eagle-0404

4 Universal

4 (4-20 mA/ 0-10 VDC)

0 0 Eagle-0404-U


Eagle-0800

8 Universal 0 0 0 Eagle-0800-U



Input Type Temperature Range 1 bit Corresponds to
J -210 to 770º C 0.43º C
K -200 to 1373º C 0.61º C
E -200 to 1000º C 0.32º C
R -50 to 1769º C 2.04º C
S -50 to 1769º C 2.31º C
B 0 to 1820º C 3.21º C
N -200 to 1300º C 0.7º C
T -200 to 400º C 0.47º C

 

Analog Outputs
Resolution 12 Bit
Load:
4-20 mA 
0-10 V DC  
Less than 500 ohms
Minimum 400 ohms
Temperature Drift (for Digital Count) 60 PPM