We offer the best product range of Mobile Earthing Electrode, Earthing Electrodes, Copper Earthing Electrodes, Copper Bonded Electrode and Copper Bonded Chemical Earthing Electrodes.

Mobile Earthing Electrode

Remedies we are offering mobile earthing electrode is the new generation portable earthing device, which can be used by any mobile equipment. Mobile earthing electrode provides a quick and efficient solution to low resistance earthing requirements of telecommunication, electronic and electrical equipment. Mobile earthing electrode effectively protects sensitive equipment by safely conducting harmful vhf, harmonics, surges, spikes, unbalances and short circuit currents into ground mass. It can be installed vertically or horizontally as per site conditions and convenience. The mobile earthing electrode can also be used as earth for lightning protection. However, for ese lps the code stipulates three earth pits connected in star or delta, which has to be followed. highlights :
  • highly efficient
  • excellent performance
View Complete Details

Copper Earthing Electrodes

  • Type Earthing Electrodes
  • Material Copper
  • Thickness 5-7mm, 7-10mm
  • Certification CE Certified
  • Length 250-500mm, 500-750mm
  • Application Earthing Purpose
  • Weight 100-200gm, 50-100gm

Acclaimed for having exceptional resistance to corrosion, matchless mechanical strengt1h and uniform earth contact resistance, these Copper Earthing Electrodes are the best. Our entire range of Copper Earthing Electrodes includes Arsh Safe Earthing Electrode and EZEE Safe Earthing Electrode. We have become a reputed name to get high-class Copper Earthing Electrodes at reasonable rates. Be it transformers or computer data processing center, our selection of Copper Earthing Electrodes guarantee high performance. What is a good Earthing systems?A good Earthing Should have a low resistance value be resistance to corrosion be independent on season / weather change. The resistance value and the corrosion factor directly depends on the nature of the soil, more exactly on its electrical resistivity. The �season change� factor depends on the moisture contents. Features

  • Based on globally accepted technology.
  • Values over the life of the product.
  • Cost effective
  • Suitable for all types of soil.
  • Superior resistance to oxidation.

Why Our Copper Earthing Electrodes?

  • Premium material used in the making
  • Conform to ISO specifications
  • High performance
  • Dependable
View Complete Details

Earthing Electrodes

We are the exporter and supplier of this products.
View Complete Details

Copper Bonded Electrode

2,900 /Piece Get Latest Price
  • Type Chemical Earthing
  • Brand Name Remedies
  • Material Copper Bonded
  • Diameter 50mm
  • Shape Pipe in Strip
  • Certification CPRI
  • Application for earthing purpose, home & industrial
  • Free sample N/a
  • Country of Origin Lucknow
  • Model Number CBE-50
We are manufacturer of Copper bonded electrode.we offer maintenance free earth electrode with chemical.we have all sizes like 40mm, 50mm, 80mm, 2meter , 3meter.Above rate is for 50 mm 3 meter copper bonded + 30 kg earth enhancement compound .
View Complete Details

Copper Bonded Chemical Earthing Electrodes

  • Type Earthing Electrodes
  • Material Aluminium
  • Thickness 0-5mm, 5-7mm
  • Length 0-250mm, 250-500mm
  • Application Earthing Purpose
  • Weight 0-50gm, 100-200gm
  • Feature Proper Working
  • Finishing Polished

We are working with highly experienced packaging experts and they make every endeavor to meet the personalized and standard requirements of the clients. We sternly make our product safe from external factors. We settle the financial transactions with our customers through the secured payment procedures. We also settle down upon a variety of negotiable instruments.

View Complete Details

Copper Earthing Electrode (Pipe In Pipe Technology)

Our clients can avail high quality Copper Electrode. These electrodes are manufactured by superior quality raw material, procured from the trusted vendors of the industry. Our gamut of products are appreciated for their durability and reliability. It works as an accessory in fiber optic industries which is used for fusion slicing.

Additional Information:

Packaging Details : To ensure the safety and prevent harm from various natural forces and other such factors, we have in place a capacious Warehousing and Packaging unit which allows us to store our products in a categorized manner for optimum efficiency and ease of access when dispatching to clients. Our Earthing Electrode, Earthing Backfill Compound, Surge Protection Device, Prefabricated Sandwich Panel and ESE Lightning Protection System are kept from the technical damage or corrosion of electrical circuits before delivery to clients.

Delivery Time : 2 - 3 week

View Complete Details

EZEE Safe Earthing Electrode

  • Type Earthing Electrodes
  • Material Aluminium
  • Thickness 5-7mm, 7-10mm
  • Length 250-500mm, 500-750mm
  • Application Earthing Purpose
  • Weight 100-200gm, 50-100gm
  • Finishing Polished
  • Feature Proper Working, Water Proof

The design of EZEE Safe Earthing Electrode is conceived in accordance to the specific features of a premium earthling system. Manufactured in confirmation to the IS 3043: 1987, EZEE Safe Earthing Electrode is known for its low impendence grounding. Whether it is lighting arrestor, diesel generators or ground fault neutralization, the EZEE Safe Earthing Electrode has stable reference and high resistance to corrosion. Construction : The Pipe-in-Pipe with strip Technology concept involves two 'B' class mild steel pipes one inserted inside the other. Both the pipes are subjected to hot dip galvanization: 80 - 100 micron on the outer electrode and 80 - 100 microns inside the electrodes. The empty space inside the electrodes is tightly filled with a specially developed Crystalline Conductive Mixture and then sealed. For uniform distribution of fault current an earthing electrode must be cylindrical in shape. The surface being circular the distance from the centre to any point is always equal. This facilitates uniform distribution of fault current from electrode to earth. AdvantagesEZEE Safe Earthing Electrode uses advanced engineering to achieve a consistent, low-impedance, electrical connection with the earth, even in unfavorable and varying ground conditions (like permafrost).

  • Safety of life and property from earth related electrical hazards
  • Strong, reliable, long life
  • Less maintenance
  • Saving on maintenance
  • Smooth dissipation of fault, lightning and short circuit currents
  • Low electrical resistance as per soil condition
  • Resistance to corrosion
  • Repeated current carrying capacity and continuity
  • Provides stable reference
  • Ideal earthing system for all kind of earthing applications
  • Adequate galvanization, Highly conductive, No corrosion, eco-friendly and a long and reliable life (Fit and Forget)
  • Can be installed indoors or outdoors and in almost all soil condition. For existing or new facilities, requires less space and time.

ApplicationsEfficient Grounding Systems reduce the risk of electrical arcing and fires. The Remedies brand âEZEEâ Safe Earthing Electrode improves reliability for many applications, including :

  • LT and HT applications â Domestic / Industries
  • Telecommunication, Transmission and Distribution systems.
  • Lightning protection systems
  • Prevention of accidents caused by static charge and stray currents
  • Substation and Power generated stations
  • Equipment earthing / Electrical machines
  • Ground fault neutralization
  • Lightning arrestor, Diesel generators etc.

Industries

  • Petrochemical, LNG, and nuclear facilities
  • Data centers, telecom, and broadcasters
  • Process control and automation
  • Corrections, hospitals, and 911 centers
  • Government, military, and defense installations
  • T&D operations, substations, and wind turbines

Installation Normal soil

  • Augur / Drill / Bore a hole of 8 - 10 inches in diameter to a suitable depth of 2 or 3 meters (Electrode length)
  • Mix Ezee backfill compound nicely with dug out soil.
  • Throw handful of compound soil mix into pit.
  • Remove plastic sleeve carefully from electrode.
  • Place naked electrode at center of pit.
  • Start refilling empty space around electrode with backfill compound in small quantities.
  • Then pour some water and poke the pit with a long wooden rod, to allow trapped air to escape.
  • In this manner gradually continue refilling process till electrode is buried in the pit, up to the green patch painted on the top portion of electrode.
  • Ensure that pit is not watery.
  • Pack electrode with compound nicely and tightly, so that it stands firmly in pit.
  • Pour a few buckets of water around pit.
  • Test earth resistivity of electrode. If result is satisfactory, connect it with equipment.
  • If result is not satisfactory, give some time for electrode system to set in soil.
  • Then check ohmic value and connect with equipment.
  • In hard soil conditions, do not mix compound with dug out soil, and follow above procedure.
  • If auguring is not possible up to 3 meters inform customer/dealer.
  • Pour a few buckets of water around the pit everyday for 10 - 15 days for system to set.

Important

  • Do not Drop Earthing electrode in pit.
  • Do not use force to drive electrode into pit
  • Do not hammer or cut electrode while installing.
  • Remove the transparent plastic cover before installation.
  • Ensure that electrode terminal and green color patch are above the soil.
  • Apply petroleum jelly on terminal and terminal hole.
  • Ensure that the entire length of electrode always remains buried in soil.
  • During peak summer months pour a few buckets of water in and around electrode for a few days. If you are in doubt, contact our dealer.
  • If soil in pit sinks, fill it with good soil

Sandy & Rocky AreasDig a trench of 6' x 6' and 11' deep; fill the entire pit with black cotton soil or normal soil, pour enough water so that pit is full with water, leave it for three days so that soil soaks up the water. You will notice that soil level has gone down and again top up the pit with soil & fill the water. Now after two or three days this pit is sturdy and ready for Earthing purpose. Our Earthing electrode can be installed as per installation method for normal soil given above. Rocky/Semi-Rocky SoilIf enough soil is there then Earthing can be done by normal method as above, otherwise follow the method as in case of sandy soil. Once installed properly Remedies Brand âEZEEâ Safe Earthing Electrode gives much better earth resistance value than conventional Earthing systems over a period of time. However, it is important to recognize the fact that characteristics of soil play a major role in determining the earth resistance value, and as per Indian/British Standards, in high resistive soil it requires more than one earth electrode installed and connected in parallel to bring down the earth resistance value within safe limits

View Complete Details

GI Earthing Electrode

Pipe in pipe technology:Manufactured As Per IS 3043 : 1987.The Pipe-in-Pipe Technology concept involves two 'B' class mild steel pipes one inserted inside the other. Both the pipes are subjected to hot dip galvanization: 80 - 100 micron on the outer electrode and 250 - 300 microns inside the electrodes.The empty space inside the electrodes is tightly filled with a specially developed Crystalline Conductive Mixture and then sealed. For uniform distribution of fault current an earthing electrode must be cylindrical in shape. The surface being circular the distance from the centre to any point is always equal. This facilitates uniform distribution of fault current from electrode to earth.

Additional Information:

Payment Terms :

Packaging Details : To ensure the safety and prevent harm from various natural forces and other such factors, we have in place a capacious Warehousing and Packaging unit which allows us to store our products in a categorized manner for optimum efficiency and ease of access when dispatching to clients. Our Earthing Electrode, Earthing Backfill Compound, Surge Protection Device, Prefabricated Sandwich Panel and ESE Lightning Protection System are kept from the technical damage or corrosion of electrical circuits before delivery to clients.

Delivery Time : 2 - 3 week

View Complete Details

Gi Earthing Electrodes

We are a renowned gi earthing electrodes manufactures and suppliers in uttar pradesh, india. The wide range of our gi earthing electrodes is made of topmost quality materials. The cylindrical shape of gi earthing electrodes eases the equal distribution of fault current from electrode to earth. We acquire the raw material from the prominent dealers in the market and stick to the iso specifications in the manufacturing process of the gi earthing electrodes. Clients can avail the gi earthing electrodes from us at very reasonable prices. pipe-in-pipe technologymanufactured as per is 3043 : 1987. The pipe-in-pipe technology concept involves two 'b' class mild steel pipes one inserted inside the other. Both the pipes are subjected to hot dip galvanization: 80 - 100 micron on the outer electrode and 250 - 300 microns inside the electrodes. The empty space inside the gi earthing electrodes is tightly filled with a specially developed crystalline conductive mixture and then sealed. For uniform distribution of fault current an earthing electrode must be cylindrical in shape. The surface being circular the distance from the centre to any point is always equal. This facilitates uniform distribution of fault current from electrode to earth. why our gi earthing electrodes?
  • made as per iso 3043: 1987
  • offer perfect earthing solution
  • highly functional
  • cost-effective rates
View Complete Details

Earthing Electrode

  • Min. Order (MOQ) 05 Set(s)
We are offering earthing electrode.Pipe in pipe technology:manufactured as per is 3043 : 1987.The pipe-in-pipe technology concept involves two 'b' class mild steel pipes one inserted inside the other. Both the pipes are subjected to hot dip galvanization: 80 - 100 micron on the outer electrode and 250 - 300 microns inside the electrodes.The empty space inside the electrodes is tightly filled with a specially developed crystalline conductive mixture and then sealed. For uniform distribution of fault current an earthing electrode must be cylindrical in shape. The surface being circular the distance from the centre to any point is always equal. This facilitates uniform distribution of fault current from electrode to earth.

Additional Information:

Payment Terms :

Delivery Time : 10-15 days

View Complete Details

Arsh Safe Earthing Electrode

  • Type Earthing Electrodes
  • Material Aluminium
  • Thickness 5-7mm, 7-10mm
  • Length 0-250mm, 250-500mm
  • Application Earthing Purpose
  • Weight 100-200gm, 50-100gm
  • Finishing Polished
  • Feature High Clarity, Smooth Texture

Arsh Safe Earthing Electrode is designed as per the most demanding of characteristics found in a great earthing system. Manufactured as per the IS 3043: 1987, the Arsh Safe Earthing Electrode is known for its hassle-free performance and ease-of-installation. Whether it is a data center, lightening protection system, electrical machinery or telecommunication center, the Arsh Safe Earthing Electrode is used in all. Construction : The Pipe-in-Pipe with strip Technology concept involves two 'B' class mild steel pipes one inserted inside the other. Both the pipes are subjected to hot dip galvanization: 80 - 100 micron on the outer electrode and 80 - 100 microns inside the electrodes. The empty space inside the electrodes is tightly filled with a specially developed Crystalline Conductive Mixture and then sealed. For uniform distribution of fault current an earthing electrode must be cylindrical in shape. The surface being circular the distance from the centre to any point is always equal. This facilitates uniform distribution of fault current from electrode to earth. AdvantagesARSH Safe Earthing Electrode uses advanced engineering to achieve a consistent, low-impedance, electrical connection with the earth, even in unfavorable and varying ground conditions (like permafrost).

  • Large surface area : The wider 25/8 inch diameter provides a larger surface area for a better connection to the earth.
  • Electrolytic salts : In the presence of moisture, these salts dissolve and seep out of leach holes along the electrode. The salts continually increase the soilâs conductivity, further reducing impedance and resistance.
  • Soil augmentation : ERIC Compound is a combination of organic soil materials which optimize the conductivity of the soil around the Earthing Electrode. Increasing the amount of ERIC Compound decrease the overall system resistance, increasing the system efficiency.
  • Maintenance-Free : This is maintenance free Earthing., no need of extra water pouring at regular interval as in conventional Earthing, because it retains the moisture.
  • Consistency : Continuously maintains the same (approx) earth resistance value over time regardless of soil and climate conditions. Unlike a standard copper plate/rod, the stability of the Safe Earthing Electrode will remain constant over the life span of the plate/rod, and the resistance of the electrode is less affected by adverse climatic conditions. Adequate galvanization, Highly conductive, No corrosion, eco-friendly and a long and reliable life (Fit and Forget)
  • Easy Installation : Can be installed indoors or outdoors and in almost all soil condition. For existing or new facilities, requires less space and time.
  • Cost effective & easy to install

ApplicationsEfficient Grounding Systems reduce the risk of electrical arcing and fires. The Remedies brand ARSH Safe Earthing Electrode improves reliability for many applications, including :

  • LT and HT applications  Domestic / Industries
  • Telecommunication, Transmission and Distribution systems.
  • Lightning protection systems
  • Prevention of accidents caused by static charge and stray currents
  • Substation and Power generated stations
  • Equipment earthing / Electrical machines
  • Ground fault neutralization
  • Lightning arrestor, Diesel generators etc.

Industries

  • Petrochemical, LNG, and nuclear facilities
  • Data centers, telecom, and broadcasters
  • Process control and automation
  • Corrections, hospitals, and 911 centers
  • Government, military, and defense installations
  • T&D operations, substations, and wind turbines

Installation Normal soil

  • Augur / Drill / Bore a hole of 8 - 10 inches in diameter to a suitable depth of 2
  • 3 meters (Electrode length)
  • Mix Eric compound nicely with dug out soil.
  • Throw handful of compound soil mix into pit.
  • Remove plastic sleeve carefully from electrode.
  • Place naked electrode at center of pit.
  • Start refilling empty space around electrode with backfill compound in small quantities.
  • Then pour some water and poke the pit with a long wooden rod, to allow trapped air to escape.
  • In this manner gradually continue refilling process till electrode is buried in the pit, up to the green patch painted on the top portion of electrode.
  • Ensure that pit is not watery.
  • Pack electrode with compound nicely and tightly, so that it stands firmly in pit
  • Pour a few buckets of water around pit.
  • Test earth resistivity of electrode. If result is satisfactory, connect it with equipment.
  • If result is not satisfactory, give some time for electrode system to set in soil.
  • Then check ohmic value and connect with equipment.
  • In hard soil conditions, do not mix compound with dug out soil, and follow above procedure.
  • If auguring is not possible up to 3 meters inform customer/dealer.
  • Pour a few buckets of water around the pit everyday for 10 - 15 days for system to set.

Important

  • Do not Drop Earthing electrode in pit.
  • Do not use force to drive electrode into pit
  • Do not hammer or cut electrode while installing.
  • Remove the transparent plastic cover before installation.
  • Ensure that electrode terminal and green color patch are above the soil.
  • Apply petroleum jelly on terminal and terminal hole.
  • Ensure that the entire length of electrode always remains buried in soil.
  • During peak summer months pour a few buckets of water in and around electrode for a few days. If you are in doubt, contact our dealer.
  • If soil in pit sinks, fill it with good soil

Sandy & Rocky AreasDig a trench of 6' x 6' and 11' deep; fill the entire pit with black cotton soil or normal soil, pour enough water so that pit is full with water, leave it for three days so that soil soaks up the water. You will notice that soil level has gone down and again top up the pit with soil & fill the water. Now after two or three days this pit is sturdy and ready for Earthing purpose. Our Earthing electrode can be installed as per installation method for normal soil given above. Rocky/Semi-Rocky SoilIf enough soil is there then Earthing can be done by normal method as above, otherwise follow the method as in case of sandy soil. Once installed properly Remedies Brand ARSH Safe Earthing Electrode gives much better earth resistance value than conventional Earthing systems over a period of time. However, it is important to recognize the fact that characteristics of soil play a major role in determining the earth resistance value, and as per Indian/British Standards, in high resistive soil it requires more than one earth electrode installed and connected in parallel to bring down the earth resistance value within safe limits.

View Complete Details

Chemical Earthing Electrodes

  • Type Earthing Electrodes
  • Material Metal
  • Thickness 5-7mm, 7-10mm
  • Certification CE Certified
  • Length 250-500mm, 500-750mm
  • Application Earthing Purpose
  • Weight 0-50gm, 100-200gm, 50-100gm
  • Feature Proper Working
  • Finishing Polished

The clients can rest assured for their payment, as our payment procedures are safe, easy to use and make hassle free transactions. We are working with a group of professionals who make special emphasis on the products packaging and ensure that the material is procured from the reliable sources only.

View Complete Details

Portable Earthing Electrodes

We are offering portable earthing electrodes. Mobi earth is the new generation portable earthing device, which can be used by any mobile equipment. Our portable earthing electrodes provide a quick and efficient solution to low resistance earthing requirements of telecommunication, electronic and electrical equipment. Mobi earth effectively protects sensitive equipment by safely conducting harmful vhf, harmonics, surges, spikes, unbalances and short circuit currents into ground mass. It can be installed vertically or horizontally as per site conditions and convenience. The mobi earth can also be used as earth for lightning protection. However for ese lps the code stipulates three earth pits connected in star or delta, which has to be followed. technical parameters
  • resistance in vertical setting : 32.5% of soil resistivity at the location
  • resistance in horizontal setting : 21.05% of soil resistivity at the location
  • unbalanced current withstand capacity : 6.28 amperes
  • short duration term duty : 596.60 amperes
    • physical data
      • body material : ss 304l
      • central conduction : spl corrosion resistance ss
      • size : 65mmdiax1.2m long
      • weight : 3 kgs appox
        • infill compound (terec+ chemical compound in granular form as under)
          • granulometry : 0.85mm to 4mmgray color and odorless
          • volumetric mass : 500-650kg per cum (compressed)450- 500kg(uncompressed)
          • solubility in water : partially soluble1000 gm per lit@ 20oc
          • ph value : 6.9-7.2
            • number of operationsupto 75 times or 2 years. The portable mobi earthing electrode has to be wiped by wet cloth after every use and stored back. It should not be washed in flowing water. Every time it is put inside the ground (for what so ever small time) is considered as a usage count. installation procedure
              • vertical setting : drill a 150 mm dia x1.5 m deep bore in the ground & place mobi earth such that the handle is above the ground. Back fill the bore with loose earth slurry. Depending on soil resistivity and desired pit resistance (pr), connect to another portable mobi earthing electrode at least 1.2m away , if lower pr is required.
              • horizontal setting : make a 600mm wide x900mmdeepx1500mm long trench in the ground. Fill the first 300mm with soil slurry. Place the portable mobi earthing electrode horizontally in the trench. Backfill the trench with loose earth slurry. Depending on soil resistivity and desired pit resistance (pr), connect with another mobi earth parallel at least 1.2 m away, if lower pr is required.
              • de-installation : after the operations are over and earthing is not required, pull the portable mobi earthing electrode out of the ground in case of vertical setting and after digging top earth layer in case of horizontal setting to pull it out of the trench. Clean softly and repack for future use
View Complete Details

Copper Earthing Electrode

Our clients can avail high quality copper earthing electrode at very reasonable price from us. This copper earthing electrode is manufactured by using superior quality raw materials that are procured from the trusted vendors in the industry. Our gamut of copper earthing electrode is highly appreciated for its durability and reliability. It works as an accessory in fiber optic industries which is used for fusion slicing. salient features :
  • based on globally accepted technology
  • values over the life of the product
  • cost effective
  • suitable for all types of soil
  • superior resistance to oxidation
    • why our copper earthing electrodes?
      • premium material used in the making
      • conform to iso specifications
      • high performance
      • dependable
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • Siraj Ahmed (Remedies Earthing Systems Pvt. Ltd.)
  • 2nd Floor, Al Fazal Enclave, Opposite Good Luck Apartment, Near Rahman Tower, Khurram Nagar, Ring Road,, Lucknow, Uttar Pradesh - 225022
  • Share us via
  • View Contact Number