1 Products availableOur product range contains a wide range of 7SR220 Overcurrent Relay, SIPROTEC 6MD86 Power Relay, SIPROTEC 6MD85 Relay, VCB Breaker Spares and Power Meter Device
7sr220 series relays include for directional control of the overcurrent and earth fault functionality and are typically installed where fault current can flow in either direction i.e. On interconnected systems. Relays have five current and four voltage inputs they are housed in e6 or e8 cases.integrated logic is provided to allow the optimal configuration of relay functionality with the relays analog inputs and binary input/output circuits. The optional auto-reclose feature offers an integrated solution for use on ohl feeders. ?the relay functionality allows highly flexible settings for current and time grading making it compatible with all types of overcurrent protections. ?protection, instrumentation and metering functionality is accessible via data comms channel(s). A front usb port for local pc connection and rear electrical rs485 port for remote connection are provided as standard, additional ports are available as options.
protection functions
supervision functions
control functions
monitoring functions
The SIPROTEC 5 Bay Controller is a control and automation device with optional protection function. It is designed for use in all voltage levels from distribution to transmission. As a full member of the SIPROTEC 5 family, it allows the use of a large number of protection functions from the SIPROTEC library with identical parameters like in the protection devices. The flexible hardware concept enables the exact fitting to all amount of process data.Main function:Bay Controller for medium and high voltage switchgear. Integrated operator panel and key switches (optional). Powerful automation functionality, easily configurable with DIGSI. A large number of protection functions available.Inputs and outputs:-6 predefined standard variants with 8/8-current/voltage transformers, -11 to 75 binary inputs, -9 to 41 binary outputsHardware flexibility:Flexible adjustable HW IO-quantity within the scope of the SIPROTEC5 modular system. The use of a second row allows more than 400 in- and outputs.Width of housing:1/3 x 19 Inch - 2/1 x 19 Inch
DIGSI 5 permits all functions to be configured and combined as required.
The SIPROTEC 5 Bay Controller is a control and automation device with optional protection function. It is designed for use in all voltage levels from distribution to transmission. As a full member of the SIPROTEC 5 family, it allows the use of a large number of protection functions from the SIPROTEC library with identical parameters like in the protection devices. The modular hardware enables the user to integrate as many IO's as needed.Main function:Bay Controller for medium and high voltage switchgear. Integrated operator panel and key switches (optional). Powerful automation functionality, easily configurable with DIGSI. A large number of protection functions available.Inputs and outputs:-5 predefined standard variants with 4/4-current/voltage transformers, -11 to 75 binary inputs, -9 to 41 binary outputsHardware flexibility:Flexible adjustable HW IO-quantity within the scope of the SIPROTEC5 modular system. The use of a second row allows more than 400 in- and outputs.Width of housing:1/3 x 19 Inch - 2/1 x 19 Inch
DIGSI 5 permits all functions to be configured and combined as required.
FUNCTIONS
paralleling device siprotec 7ve85 is specifically designed for the synchronization of generators (power plant units) with the power grid or synchronization of 2 electricity-supply systems.
the 1.5- and 2-channel synchronization function is the made function of the siprotec 7ve85. To warrant a high level of security and reliability, the software works with various monitoring functions. In addition, the most important hardware components are duplicated. Two different measuring algorithms are used in accordance with the multi-channel redundancy. This avoids overfunctions through systematic errors. At the same time, the different methods of measurement are applied and processed independently of each other with different memory areas. The high level of reliability and flexible options to adapt to the equipment requirements allow a wide variety of applications.
function
digsi 5 permits all functions to be configured and combined as required.
stabilization function for the output of adaptive frequency control pulses
synchrocheck function for manual synchronization
analog output of operational measured values*
commissioning (measurement of the operating time of the circuit breaker, sample synchronization)
functionality for protection and network decoupling tasks
undervoltage protection (ansi 27)
overvoltage protection (ansi 59)
voltage differential protection (ansi 60)
overcurrent protection (ansi 50/51)
vector jump
overfrequency (ansi 81)
underfrequency (ansi 81)
rate-of-frequency-change protection (ansi 81r)
instantaneous high-current tripping (ansi 50hs)
instantaneous tripping at switch upon error
power protection active/reactive power (ansi 32/37)
power-plant disconnection (ansi 37)
circuit-breaker failure protection (ansi 50bf)
circuit breaker reignition monitoring (rbrf)
extensive cyber security functionality, such as role-based access control (rbac), protocolling security-related events or signed firmware
simple, quick and secure access to device data via a standard web browser without additional software
the 7sr11 series of relays provide overcurrent and earth fault protection. These relays are typically applied to provide the main protection on feeders and interconnectors and the back-up protection on items of plant such as transformers. On distribution system circuits overcurrent and earth fault protection is often the only protection installed.the 7sr12 includes for directional control of the overcurrent and earth fault functionality and is typically installed where fault current can flow in either direction i.e. On interconnected systems.the relay functionality allows highly flexible settings for current and time grading making it compatible with all types of overcurrent protections.the relays are available in single and four pole variants housed in e4 cases with the iec61850 protocol option housed in an e6 case. Integrated logic is provided to allow the optimal configuration of relay functionality with the relays analog inputs and binary input/output circuits.protection, instrumentation and metering functionality is accessible via data comms channel(s). A front usb port for local pc connection or rear electrical rs485 port for remote connection are provided.
function
protection functions
supervision functions
control functions
auto reclose (79)
monitoring functions
merging unit siprotec 6mu80 for conventional instrument transformers. This device allows conversion of current substations to process bus substations without change in the primary equipment.the advantages of process bus can be used, but also a mixed configuration of process bus / non-process bus is possible.siemens process bus solutions not only fulfill the standard but increase customer value beyond.
function
the siprotec 6mu80 merging units are not only certified according iec 61850-9-2le for process bus applications but include a lot of additional features. Some, but not all, of the additional features are:
electric arcs are among the most dreaded fault scenarios in power supply engineering. They can be caused by a multitude of factors, such as aging of the insulation, environmental conditions as well as operating errors. Electric arcs can cause heavy damage to switchgear and present a serious hazard to operating personnel. The siprotec 5 arc protection detects electric arcs through an optical sensor. Arcs are detected reliably and quickly as they develop, and the protective device can trip immediately and without delay times.the arc protection module is part of the new siprotec 5 series of modular, flexible and intelligent bay devices and can be used in the following device types:support of feeder automation applications, e.g. Fault isolation and service restoration-siprotec 7sj8-siprotec 7sa8-siprotec 7sd8-siprotec 7sl8-siprotec 7vk8-siprotec 7ut8-siprotec 7sk8-siprotec 7um8
function
the siprotec 4 breaker management relay 7vk61 is a highly flexible autorecloser, synchro-check, and circuit breaker failure protection unit. This unit is used for the single and three pole auto-reclosure of a circuit-breaker after this circuit breaker has tripped due to a fault.the synchro-check function ensures that the two circuits being reconnected by closing the circuit-breaker are within a defined safe operating state before the close command is issued.the 7vk61 is also applicable as circuit breaker failure protection. A breaker failure occurs when the circuit-breaker fails to correctly open and clear the fault after single or three-pole trip commands have been issued by the protection.it is then necessary to trip the relevant busbar zone (section) to ensure fault clearance. Together with the above-mentioned protection functions, the following additional functions of the 7vk61 can be applied: end-fault protection, pole-discrepancy protection, overvoltage protection and under voltage protection. As a member of the numerical siprotec 4 relay family, it also provides control and monitoring functions and therefore supports the user with regard to a cost-effective power system management.
function
protection functions
single and/or three-pole auto-reclosure
synchro-check with live/dead line/bus measurement
closing under asynchronous conditions (consideration of cb operating time)
circuit-breaker failure protection with two stages (single and three-pole with/without current)
end-fault protection
pole-discrepancy protection
overvoltage/undervoltage protection
control function
commands f. Ctrl. Of cb and isolators
monitoring functions
operational measured values
self-supervision of the relay
event buffer and fault protocols
oscillographic fault recording
monitoring of cb auxiliary contacts
switching statistics
features
all functions can be used separately
initiation/start by phase-segregated or 3-pole trip commands
auto-reclosure for max. 8 reclose cycles
evolving/sequential trip recognition
auto-reclosure with adt, dlc, rdt
synchro-check with v, , f measurement
breaker failure protection with highly secure 2-out-of-4 current check detectors
breaker failure protection with short reset time and negligible overshoot time
communication interfaces
front interface for connecting a pc
system interface for connecting to a control system via various protocolsiec 61850 ethernetiec 60870-5-103 protocolprofibus-fms/-dpdnp 3.0
rear-side service/modem interface
time synchronization viairig-b or dcf77 or system interface
the siprotec 7ut612 differential protection relay is used for fast and selective fault clearing of short-circuits in transformers of all voltage levels and also in rotating electric machines like motors and generators, for short lines and busbars. The protection relay can be parameterized for use with three-phase and single-phase transformers.the specific application can be chosen by parameterization. In this way, an optimal adaption of the relay to the protected object can be achieved.in addition to the differential function, a backup overcurrent protection for 1 winding/star point is integrated into the relay. Optionally, a low or high-impedance restricted earth fault protection, a negative sequence protection, and a breaker failure protection can be used. With external temperature monitoring boxes (thermo-boxes) temperatures can be measured and monitored in the relay.therefore, complete thermal monitoring of a transformer is possible, e.g. Hot-spot calculation of the oil temperature. The relays provide easy-to-use local control and automation functions. The integrated programmable logic (cfc) allows the users to implement their own functions, e.g. For the automation of switchgear (interlocking). User-defined messages can be generated as well.the flexible communication interfaces are open for modem communication architectures with the control system. The protection relay can be parameterized for use with three-phase and single-phase transformers. In addition to this, a thermal replica is integrated for the supervision of the ohmic losses in the plant.
function
differential protection for two-winding transformers (3-/1-phase)
differential protection for motors and generators
differential protection for short lines
differential protection for busbars up to 7 feeders (phase-segregated or with summation ct)
differential protection with phase-segregated measurement
sensitive measuring stage for low-fault currents
fast tripping for high-fault currents
restraint against inrush of the transformer
phase/ground-overcurrent protection
overload protection with or without temperature measurement
negative-sequence protection
breaker failure protection
low-or high-impedance restricted earth fault (ref)
commands for control of c.b. And isolators
control via keyboard, binary inputs, digsi 4 or scada system
user-defined logic with cfc
self-supervision of the relay
trip circuit supervision
oscillographic fault recording
permanent differential and restraint current measurement, extensive scope of operational values
pc front port for setting with digsi 4
system interface iec 61850 ethernet - iec 60870-5-103 protocol - profibus-fms - profibus-dp - modbus - dnp 3.0
service interface for digsi 4 (modem)/temperature monitoring (thermo-box)
time synchronization via irig-b/dcf 77
the siprotec 4 7um62 protection relays can do more than just protect. They also offer numerous additional functions. Be it earth faults, short-circuits, overloads, over voltage, over frequency or under frequency asynchronous conditions, protection relays assure continued operation of power stations. The siprotec 4 7um62 protection relay is a compact unit which has been specially developed and designed for the protection of small, medium-sized and large generators.they integrate all the necessary protection functions and are particularly suited for the protection of:-hydro and pumped-storage generators-co-generation stations-private power stations using regenerative energy sources such as wind or biogases-diesel generator stations-gas-turbine power stations-industrial power stations-conventional steam power stationsthe siprotec 4 7um62 includes all necessary protection functions for large synchronous and asynchronous motors and for transformers. The integrated programmable logic functions (continuous function chart cfc) offer the user high flexibility so that generators, motors, and transformers adjustments can easily be made to the varying power station requirements on the basis of special system conditions. The flexible communication interfaces are open for modern communication architectures with the control system.the following basic functions are available for all versions:-current differential protection for generators, motors, and transformers-stator earth-fault protection-sensitive earth-fault protection-stator overload protection-overcurrent- time protection (either definite time or inverse time)-definite-time overcurrent protection with directionality, undervoltage and overvoltage protection-undervoltage and overvoltage protection-underfrequency and over frequency protection-external trip coupling- forward-power and reverse power protection-negative-sequence protection-breaker failure protection-rotor earth-faults protection (fn, r-measuring)motor starting time supervision and restart inhibit for motors
functions
standard versionscope of basic version plus:
inadvertent energization protection
100 %-stator earth-fault protection with 3rd harmonic
impedance protection
full versionscope of standard version plus:
dc voltage protection
overcurrent protection during start-ups
earth-current differential protection
out-of-step protection
additional versionavailable for each version:
sensitive rotor earth-fault protection (1-3 hz method)
stator earth-fault protection with 20 hz voltage
rate-of-frequency-change protection
vector jump supervision
monitoring functions
trip circuit supervision
fuse failure monitor
operational measured values v, i, f,
the siprotec compact 7sk81 provides 4 low-power current transformer inputs and optionally 3 low-power voltage transformer inputs. With the same low-power current transformer (lpct) a wide range of primary rated line currents can be covered. Objects with rated currents in the rangefrom 20 a to 2500 a can be protected when using low-power current transformers.the following low-power current transformer ratios are suitable for the following primary current operating ranges:highlights-300 a/225 mv for a primary operating current range of 60 a to 630 a-600 a/225 mv for a primary operating current range of 120 a to 1250 a-1250 a/225 mv for a primary operating current range of 250 a to 2500 a-100 a/225 mv for a primary operating current range of 20 a to 200 athe siprotec 7sk81 is a multi-functional motor protection relay. It is designed for protection of asynchronous motors of all sizes. The relays have all the required functions to be applied as a backup relay to a transformer differential relay. The relay provides numerous functions to respond flexibly to the system requirements and to deploy the invested capital economically. Examples for this are: exchangeable interfaces, flexible protection functions and the integrated automation level (cfc). Freely assignable leds and a six-line display ensure a unique and clear display of the process states. In combination with up to 9 function keys, the operating personnel can react quickly and safely in any situation. This guarantees a high operational reliability.highlights-inputs for low power cts and vts according to iec 61869-6 (formerly iec 60044-7 and iec 60044-8)-removable terminal blocks-binary input thresholds settable using digsi (3 stages)-9 programmable function keys-6-line display-buffer battery exchangeable from the front-usb front port-2 additional communication ports-integrated switch for low-cost and redundant optical ethernet rings-ethernet redundancy protocols rstp, prp and hsr for highest availability-relay-to-relay communication through ethernet with iec 61850 goose-millisecond-accurate time synchronization through ethernet with sntp
function
control functions/programmable logic
monitoring functions
the siprotec 7sa64 distance protection relay is a universal relay for protection, control and automation with a graphic display on the basis of the siprotec 4 system. Its high level of flexibility makes it suitable to be implemented at all voltage levels. With this relay you are ideally equipped for the future: it offers security of investment and also saves on operating costs. High-speed tripping time-impedance setting range allows very small settings for the protection of very short lines-self-setting detection for power swing frequencies up to 7 hz-current transformer saturation detector prevents non-selective tripping by distance protection in the event of ct saturation.-phase-segregated teleprotection for improved selectivity and availability-digital relay-to-relay communication by means of an integrated serial protection data interface-adaptive auto-reclosure (adt)
protection functions
non-switched distance protection with 6 measuring systems (21/21n)
high resistance earth-fault protection for single and three-phase tripping (50n, 51n, 67n)
earth-fault detection in isolated and resonant-earthed networks
tele (pilot) protection (85)
fault locator (fl)
power-swing detection/tripping (68/68t)
phase-overcurrent protection (50/51)
switch-onto-fault protection (50hs)
stub bus overcurrent protection (50stub)
overvoltage/undervoltage protection (59/27)
over/underfrequency protection (81o/u)
auto-reclosure (79)
synchro-check (25)
breaker failure protection (50bf)
thermal overload protection (49)
control functions
commands for control of c.b. And isolators
monitoring functions
trip circuit supervision (74tc)
self-supervision of the relay
measured-value supervision
event logging
fault logging
oscillographic fault recording
switching statistics
front design
easy operation with numeric keys
function keys
leds for local alarm
pc front port for convenient relay setting
communication interfaces
front interface for connecting a pc
system interface for connecting to a control system via various protocols- iec 60870-5-103 protocol- profibus-fms/-dp- dnp 3.0- iec 61850 ethernet
1 serial protection data interface for teleprotection
rear-side service/modem interface
time synchronization via - irig-b or dcf 77 or - system interface
the siprotec 7ss52 numerical protection is a selective, reliable and fast protection for busbar faults and breaker failure in medium, high and extra-high voltage substations with various possible busbar configurations.the protection is suitable for all switchgear types with iron-core or linearized current transformers. The short tripping time is especially advantageous for applications with high fault levels or where fast fault clearance is required for power system stability.the modular hardware allows the protection to be optimally matched to the busbar configuration. The decentralized arrangement allows the cabling costs in the substation to be drastically reduced. The 7ss52 busbar protection caters for single, double or triple busbar systems with or without and quadruple busbar systems without transfer bus with up to: 48 bays, 16 bus couplers, and 24 sectionalizing disconnectors and 12 busbar sections.
busbar protection functions
busbar differential protection
selective zone tripping
very short tripping time (
the 7sr191 capa is a numerical protection device with a highly comprehensive functional software package.the market for power capacitors is continually growing due to the expanding power network driven by increased customer demand. Power capacitors improve the performance, quality and efficiency of the system and minimize power loss. The 7sr191 capa protection relay is designed with all of the necessary functionality for use on shunt connected distribution capacitor banks arranged in all of the common connection configurations:-single star-double star-delta-h configurationthe 7sr191 capa is a numerical protection device with a highly comprehensive functional software package which includes a range of integral application functions aimed at reducing installation, commissioning, wiring and engineering time.
features
the siprotec 7sj66 unit is a numerical protection, control, and monitoring device. Siprotec 7sj66 is featuring the "flexible protection functions". Up to 20 protection functions can be added according to individual requirements. Thus, for example, a rate-of-frequency-change protection or reverse power protection can be implemented.the relay provides control of the circuit-breaker, further switching devices and automation functions. The integrated graphical logic editor (cfc) allows the user to implement its own functions, e. G. For the automation of switchgear (interlocking). The communication interfaces support the easy integration into modern communication networks.
overcurrent protection
directional overcurrent protection
sensitive directional ground-fault detection
displacement voltage
intermittent ground-fault protection
directional intermittent ground fault protect
high-impedance restricted ground fault
inrush restraint
motor protection
overload protection
temperature monitoring
under-/overvoltage protection
under-/overfrequency protection
rate-of-frequency-change protection
power protection (e.g. Reverse, factor)
undervoltage controlled reactive power protection
breaker failure protection
negative-sequence protection
phase-sequence monitoring
synchro-check
fault locator
lockout
auto-reclosure
commands for control of cb and of isolators
graphical visualization of switch positions
control via keyboard, binary inputs, digsi 4 or scada system
user-defined logic with cfc (e.g. Interlocking)
operational measured values v, i, f
energy metering values wp, wq
circuit-breaker wear monitoring
slave pointer
trip circuit supervision
fuse failure monitor
8 oscillographic fault records
motor statistics
english, spanish, russian, polish and turkish
system interface protocols: iec 60870-5-103, iec 61850, modbus rtu, dnp3
electrical and optical interface
rstp (redundancy protocol for ethernet)
service interface for digsi 4 or rtd-box
front usb interface for digsi 4
time synchronization via irig b, dcf77
spring-type terminals
4 current transformers
4 voltage transformers
16/22/36 binary inputs
7/10/23 output relays
graphic or 8 line display
the siprotec 7sa6 distance protection relay is a universal relay for protection, control and automation with a graphic display on the basis of the siprotec 4 system.its high level of flexibility makes it suitable to be implemented at all voltage levels. With this relay you are ideally equipped for the future: it offers security of investment and also saves on operating costs.-high-speed tripping time-impedance setting range allows very small settings for the protection of very short lines-self-setting detection for power swing frequencies up to 7 hz-current transformer saturation detector prevents non-selective trapping by distance protection in the event of ct saturation.-phase-segregated teleportation for improved selectivity and availability-digital relay-to-relay communication by means of an integrated serial protection data interface-adaptive auto-reclosure (adt)
protection functions
non-switched distance protection with 6 measuring systems (21/21n)
high resistance earth-fault protection for single and three-phase tripping (50n, 51n, 67n)
earth-fault detection in isolated and resonant-earthed networks
tele (pilot) protection (85)
fault locator (fl)
power-swing detection/tripping (68/68t)
phase-overcurrent protection (50/51)
switch-onto-fault protection(50hs)
stub bus overcurrent protection (50stub)
overvoltage/undervoltage protection(59/27)
over/underfrequency protection (81o/u)
auto-reclosure (79)
synchro-check (25)
breaker failure protection (59bf)
thermal overload protection (49)
control functions
commands for control of c.b. And isolators
monitoring functions
trip circuit supervision (74tc)
self-supervision of the relay
measured-value supervision
event logging
fault logging
oscillographic fault recording
switching statistics
front design
easy operation with numeric keys
function keys
leds for local alarm
pc front port for convenient relay setting
communication interfaces
front interface for connecting a pc
system interface for connecting to a control system via various protocols- iec 60870-5-103 protocol- profibus-fms/-dp- dnp 3.0- iec 61850 ethernet
1 serial protection data interface for teleprotection
rear-side service/modem interface
time synchronization via - irig-b or dcf 77 or - system interface
the 6md66 high-voltage bay control unit is the control unit for high voltage bays from the siprotec 4 relay series. Because of its integrated functions, it is an optimum, low-cost solution for high-voltage switch bays. The 6md66 high-voltage bay controller unit also has the same design (look and feel) as the other protection and combined units of the siprotec 4 relay series. Configuration is performed in a standardised way with the easy-to-use digsi 4 configuration tool.for operation, a large graphic display with a keyboard is available. The important operating actions are performed in a simple and intuitive way, e.g. Alarm list display or switch gear control. The operator panel can be mounted separately from the unit, if required. Thus, flexibility with regard to the mounting position of the unit is ensured. Integrated key-operated switches control the switching authority and authorisation for switching without interlocking. High-accuracy measurement ( 0.5 %) for voltage, current and calculated values p and q are another feature of the unit.
application
integrated synchro-check for synchronized closing of the circuit-breaker
breaker-related protection functions (breaker failure 50bf, auto-reclosure 79)
automation can be configured easily by graphic means with cfc
flexible, powerful measured-value processing
connection for 4 voltage transformers, 3 current transformers, two 20 ma transducers
volume of signals for high voltage
up to 14 1 -pole circuit-breakers can be operated
up to 11 2-pole switching devices can be operated
up to 65 indication inputs, up to 45 command relays
the 7sr23 dad is a numeric high impedance circulating current relay has four current inputs, it is used as a unit protection to detect phase and earth faults.the relay can be applied to bus bars, connections, transformers, reactors, and motors.the relay is used in high impedance applications in conjunction with external stabilizing resistors and non-linear resistors (metrosils). Standardized external components can be provided in an epsilon case to facilitate design and installation.the integral ct supervision feature detects open circuits in the ct secondary wiring circuits, a consideration where ct circuits are switched.relays are housed in e6 or e8 cases. Integrated logic is provided to allow the optimal configuration of relay input and output functionality. Protection, instrumentation and metering functionality is accessible via data comms channels. A front fascia usb port for local connection and rs485 rear port for remote connection are provided as standard, additional rear ports are available as options.
protection functions
supervision functions
monitoring functions
instrumentation
further functions
the 7pg23 electro-mechanical single phase circulating current protection is used to detect earth faults in high impedance protection schemes. The relay is typically applied used in transformer protection schemes.one relay per phase can be applied to detect both phase and earth faults e.g. On reactors and stator windings of large machines.the relay is a voltage operating device and has a user selectable operate voltage setting. The relay can be used in conjunction with an external shunt setting resistor where a higher operate current is required. An integral non-linear resistor limits over-voltages occurring during system faults. Operation flag indicator. Relays are housed in size e3 cases.
protection functions
high impedance restricted earth fault
features
7PJ1524 High Speed Trip relay is a multi-contact attractedarmature relays designed to IEC 60255-1.- High speed, high burden, positive action, instantaneouscutoff.- 7PJ1524 trip relay allows to use the Trip CircuitSupervision relay (7PJ13) to monitor and supervise theintegrity of trip circuit with coil supervision terminal.- Supplied in draw-out type case.- Robust design for a long, reliable service life.
High burden, Trip Relay SeriesHigh burden relays with immunity to capacitance discharge currents. These relays are suitable for applications wherethey are located remotely from the initiation signal.
Variants MLFB Ordering Code7PJ1524-1JC60-1AF0 High Speed Trip Relay, 10 Contact(8NO+2NC), High Burden, ContactHand Reset + Electrical Reset, Hand Reset Flag, 125 V DC7PJ1524-1JC60-1AH0 High Speed Trip Relay, 10 Contact(8NO+2NC), High Burden, ContactHand Reset + Electrical Reset, Hand Reset Flag, 240 V DC7PJ1524-1UC80-1CF0 High Speed Trip Relay, 20 Contact(18NO+2NC), High Burden, Contact Hand Reset + ElectricalReset, Hand Reset Flag, 125 V DC7PJ1524-1UC80-1CH0 High Speed Trip Relay, 20 Contact(18NO+2NC), High Burden, Contact Hand Reset + ElectricalReset, Hand Reset Flag, 240 V DC
auxiliary relay and trip relay is an electro-mechanical relay that operates on attracted armature principal designed to iec60255. Auxiliary relay is available in 3 no contacts and 2 co contacts with self reset contacts type with or without flag. Trip relay low burden is available in 3 no and 3 nc contacts. Trip relay high burden is available in 3 no and 2 nc contacts with hand reset contacts type. Auxiliary relay and trip relay is used in high speed operation which suits the requirements like transmission and industrial applications
auxiliary relay with self reset contacts without flag, dc 110 v, 3 no + 2 co, low burden
auxiliary relay with self reset contacts without flag, dc 220 v, 3 no + 2 co, low burden
auxiliary relay with self reset contacts with flag, dc 110 v, 3 no + 2 co, low burden
auxiliary relay with self reset contacts with flag, dc 220 v, 3 no + 2 co, low burden