Post Buy Requirement
RI

Ramkrishna Iron Works Pvt. Ltd.

Add Review

Sensors

Our Complete range of products are Temperature Sensor, Barometric Pressure Sensor and Relative Humidity Sensor.

Temperature Sensor

110S Temperature Sensor

The 110S Temperature Sensor is a durable and economical integrated circuit temperature sensor that provides a high level voltage output signal.

The 110S is ideally suited for the temperature measurement requirements of remote wind and solar energy studies. Recommended uses of the data from this sensor include calculating energy density calculations; monitoring air temperature; calculating atmospheric stability conditions; identifying icing conditions in cold climates; and estimating PV panel efficiency, which is temperature dependent.

A calibrated version, the 110SC, is available when the lowest uncertainty is the priority. It is suggested for differential temperature measurements, where two temperature sensors are deployed on the same tower.

This sensor includes an internal reference, amplifiers, and linearization enclosed in a six-plate UV-stabilized radiation shield. The universal mounting assembly connects quickly to any pipe or tower.

The sensor comes with a potted 5 m, 67 m or 90 m sensor cable. If you require a different cable length, please contact us.

Specifications
110S Temperature Sensor 5m Cable (#1906)110S Temperature Sensor 67m Cable (#6610)110S Temperature Sensor 90m Cable (#9036)110SC Temperature Sensor 5m Cable (#4429)110SC Temperature Sensor 67m Cable (#9035)110SC Temperature Sensor 90m Cable (#9037)DescriptionSensor type Applications Sensor range Instrument compatibility Output signalSignal type Transfer function Accuracy Electrical time constant Output signal range Response characteristicsThermal time constant Power requirementsSupply voltage Supply current InstallationMounting Tools required EnvironmentalOperating temperature range Operating humidity range Lifespan PhysicalConnections Cable length Weight Dimensions MaterialsCable Probe Shield
Integrated circuit temperature sensor with six plate radiation shield Integrated circuit temperature sensor with six plate radiation shield Integrated circuit temperature sensor with six plate radiation shield Integrated circuit temperature sensor with six plate radiation shield Integrated circuit temperature sensor with six plate radiation shield Integrated circuit temperature sensor with six plate radiation shield
  • Wind resource assessment
  • Meteorological studies
  • Environmental monitoring
  • Wind resource assessment
  • Meteorological studies
  • Environmental monitoring
  • Wind resource assessment
  • Meteorological studies
  • Environmental monitoring
  • Wind resource assessment
  • Meteorological studies
  • Environmental monitoring
  • Wind resource assessment
  • Meteorological studies
  • Environmental monitoring
  • Wind resource assessment
  • Meteorological studies
  • Environmental monitoring
-40 C to 52.5 C (-40 F to 126.5 F) -40 C to 52.5 C (-40 F to 126.5 F) -40 C to 52.5 C (-40 F to 126.5 F) -40 C to 52.5 C (-40 F to 126.5 F) -40 C to 52.5 C (-40 F to 126.5 F) -40 C to 52.5 C (-40 F to 126.5 F)
All RNRG loggers All RNRG loggers All RNRG loggers All RNRG loggers All RNRG loggers All RNRG loggers
Linear analog voltage Linear analog voltage Linear analog voltage Linear analog voltage Linear analog voltage Linear analog voltage
Temp = (Voltage x 55.55) - 86.38 C[Temp = (Voltage x 100) - 123.5 F] Temp = (Voltage x 55.55) - 86.38 C[Temp = (Voltage x 100) - 123.5 F] Temp = (Voltage x 55.55) - 86.38 C[Temp = (Voltage x 100) - 123.5 F] Temp = (Voltage x 55.55) - 86.38 C[Temp = (Voltage x 100) - 123.5 F] Temp = (Voltage x 55.55) - 86.38 C[Temp = (Voltage x 100) - 123.5 F] Temp = (Voltage x 55.55) - 86.38 C[Temp = (Voltage x 100) - 123.5 F]
Uncertainty (k=2): 1.24C (2.23F) Uncertainty (k=2): 1.24C (2.23F) Uncertainty (k=2): 1.24C (2.23F) Uncertainty (k=2): 0.43C (0.77F) Uncertainty (k=2): 0.43C (0.77F) Uncertainty (k=2): 0.43C (0.77F)
250 s 250 s 250 s 250 s 250 s 250 s
0 V to 2.5 V DC 0 V to 2.5 V DC 0 V to 2.5 V DC 0 V to 2.5 V DC 0 V to 2.5 V DC 0 V to 2.5 V DC
10 minutes 10 minutes 10 minutes 10 minutes 10 minutes 10 minutes
4 V to 35 V DC 4 V to 35 V DC 4 V to 35 V DC 4 V to 35 V DC 4 V to 35 V DC 4 V to 35 V DC
300 A max. (no load on output) 300 A max. (no load on output) 300 A max. (no load on output) 300 A max. (no load on output) 300 A max. (no load on output) 300 A max. (no load on output)
Attaches to tower with included hose clamps Attaches to tower with included hose clamps Attaches to tower with included hose clamps Attaches to tower with included hose clamps Attaches to tower with included hose clamps Attaches to tower with included hose clamps
  • 8mm (5/16 inch) nut driver or flat blade (-) screwdriver (to install hose clamps)
  • Sheet metal shears or similar (for trimming hose clamps)
  • 8mm (5/16 inch) nut driver or flat blade (-) screwdriver (to install hose clamps)
  • Sheet metal shears or similar (for trimming hose clamps)
  • 8mm (5/16 inch) nut driver or flat blade (-) screwdriver (to install hose clamps)
  • Sheet metal shears or similar (for trimming hose clamps)
  • 8mm (5/16 inch) nut driver or flat blade (-) screwdriver (to install hose clamps)
  • Sheet metal shears or similar (for trimming hose clamps)
  • 8mm (5/16 inch) nut driver or flat blade (-) screwdriver (to install hose clamps)
  • Sheet metal shears or similar (for trimming hose clamps)
  • 8mm (5/16 inch) nut driver or flat blade (-) screwdriver (to install hose clamps)
  • Sheet metal shears or similar (for trimming hose clamps)
-40 C to 52.5 C (-40 F to 126.5 F) -40 C to 52.5 C (-40 F to 126.5 F) -40 C to 52.5 C (-40 F to 126.5 F) -40 C to 52.5 C (-40 F to 126.5 F) -40 C to 52.5 C (-40 F to 126.5 F) -40 C to 52.5 C (-40 F to 126.5 F)
0 to 100% RH 0 to 100% RH 0 to 100% RH 0 to 100% RH 0 to 100% RH 0 to 100% RH
10 years + 10 years + 10 years + 10 years + 10 years + 10 years +
Wire leads:
  • Signal (clear wire)
  • Ground (black wire)
  • Excitation (red wire)
  • Shield wire for earth ground
Wire leads:
  • Signal (clear wire)
  • Ground (black wire)
  • Excitation (red wire)
  • Shield wire for earth ground
Wire leads:
  • Signal (clear wire)
  • Ground (black wire)
  • Excitation (red wire)
  • Shield wire for earth ground
Wire leads:
  • Signal (clear wire)
  • Ground (black wire)
  • Excitation (red wire)
  • Shield wire for earth ground
Wire leads:
  • Signal (clear wire)
  • Ground (black wire)
  • Excitation (red wire)
  • Shield wire for earth ground
Wire leads:
  • Signal (clear wire)
  • Ground (black wire)
  • Excitation (red wire)
  • Shield wire for earth ground
5 m (16 ft) 67 m (220 ft) 90 m (295 ft) 5 m (16 ft) 67 m (220 ft) 90 m (295 ft)
0.47 kg (1.04 lbs) 2.63 kg (5.80 lbs) 3.4 kg (7.6 lbs) 0.47 kg (1.04 lbs) 2.63 kg (5.80 lbs) 3.4 kg (7.6 lbs)
  • Sensor only: 30.5 mm (1.2") height x 12.7 mm (0.5") diameter
  • Sensor with radiation shield: 127 mm (5") diameter x 127 mm (5 inches) height
  • Sensor only: 30.5 mm (1.2") height x 12.7 mm (0.5") diameter
  • Sensor with radiation shield: 127 mm (5") diameter x 127 mm (5 inches) height
  • Sensor only: 30.5 mm (1.2") height x 12.7 mm (0.5") diameter
  • Sensor with radiation shield: 127 mm (5") diameter x 127 mm (5 inches) height
  • Sensor only: 30.5 mm (1.2") height x 12.7 mm (0.5") diameter
  • Sensor with radiation shield: 127 mm (5") diameter x 127 mm (5 inches) height
  • Sensor only: 30.5 mm (1.2") height x 12.7 mm (0.5") diameter
  • Sensor with radiation shield: 127 mm (5") diameter x 127 mm (5 inches) height
  • Sensor only: 30.5 mm (1.2") height x 12.7 mm (0.5") diameter
  • Sensor with radiation shield: 127 mm (5") diameter x 127 mm (5 inches) height
3 conductor 22 AWG, with overall foil shield and drain wire, chrome PVC jacket 3 conductor 22 AWG, with overall foil shield and drain wire, chrome PVC jacket 3 conductor 22 AWG, with overall foil shield and drain wire, chrome PVC jacket 3 conductor 22 AWG, with overall foil shield and drain wire, chrome PVC jacket 3 conductor 22 AWG, with overall foil shield and drain wire, chrome PVC jacket 3 conductor 22 AWG, with overall foil shield and drain wire, chrome PVC jacket
Aluminum, epoxy filled Aluminum, epoxy filled Aluminum, epoxy filled Aluminum, epoxy filled Aluminum, epoxy filled Aluminum, epoxy filled
UV-stabilized thermoplastic solar radiation shield UV-stabilized thermoplastic solar radiation shield UV-stabilized thermoplastic solar radiation shield UV-stabilized thermoplastic solar radiation shield UV-stabilized thermoplastic solar radiation shield UV-stabilized thermoplastic solar radiation shield
View Complete Details

Barometric Pressure Sensor

  • Linear analog voltage Absolute Pressure in kPa = (Voltage x 21.79) + 10.55 typical
  • +/- 1.5 kPa (15 mb) max. uncorrected offset (+/- 0.443 inches Hg) Calibration sheet included with each sensor specifies offset correction
BP20 Barometric Pressure Sensor

A micro-machined absolute pressure sensor, the BP20 provides a high-level voltage output signal that is proportional to absolute pressure.

The BP20 pressure sensor includes built-in temperature compensation, linearization, and an output amplifier. Its low cost and rugged ABS enclosure make the BP20 ideal for collecting absolute pressure data at remote sites.

Specifications
BP20 Barometric Pressure Sensor (#2046)DescriptionSensor type Applications Sensor range Instrument compatibility Output signalSignal type Transfer function Accuracy Calibration Turn on time Power requirementsSupply voltage Supply current InstallationMounting Tools required EnvironmentalOperating temperature range PhysicalConnections Cable length Weight Dimensions MaterialsCable Enclosure
Micromachined integrated circuit absolute pressure sensor
  • Wind resource assessment
  • Meteorological studies
  • Environmental monitoring
15 kPa to 115 kPa (4.43 inches to 34.0 inches Hg)
All Symphonie Data Loggers
Linear analog voltage
Absolute Pressure in kPa = (Voltage x 21.79) + 10.55 typical
+/- 1.5 kPa (15 mb) max. uncorrected offset (+/- 0.443 inches Hg)
Calibration sheet included with each sensor specifies offset correction
15 ms
7 V to 35 V DC
15 mA max. (8 mA typical)
Mounts directly to tower or inside steel shelter box with hose clamps (included)
8mm (5/16 inch) nut driver or flat blade screwdriver
  • 10 C to 50 C at full accuracy
  • At cold temperatures, offset increases by 3 kPa (30 mb) worst case at -30 C.
Wire leads, 3 conductor shielded cable:
  • Red: sensor power
  • White: output signal
  • Black: sensor ground
  • Shield wire: to earth ground
  • 1.5 m (5 feet)
  • cable diameter 4.8 mm (3/16 inches)
0.1 kg (0.2 pounds)
  • 57 mm (2.25 inches) diameter
  • 112 mm (4.4 inches) length (including cable bushing)
3 conductor 22 AWG, with overall foil shield and drain wire, chrome PVC jacket
Weatherproof black ABS
View Complete Details

Relative Humidity Sensor

RH5X Relative Humidity Sensor

The RH5X is a low-cost continuous measurement relative humidity sensor.

The RH5X sensor is compatible with all Symphonie series data loggers when equipped with an RNRG iPack and either aSymphonie SCM Card(SCM #3156, used withSymphoniePLUS3 Data Loggerand older) or a Pro Signal Conditioning Module (P-SCM #9132, used withSymphoniePRO Data Loggerwhen channels 16-19 are unavailable).

The RH5X features a polymer resistor sensor, which provides excellent linearity and sensitivity with fast response time and long-term stability. It mounts to the underside of a shelter box and includes 1.5 m (5) of cable, a mounting bracket, and one hose clamp.

A calibrated version, the RH5XC, is available. The RH5XC comes with a calibration certificate from a NIST-traceable humidity chamber, providing slope and offset values that can be used to configure your corresponding logger channel.

Specifications
RH5X Relative Humidity Sensor (#4415)RH5XC Relative Humidity Sensor (#8811)DescriptionSensor type Applications Sensor range Instrument compatibility Output signalSignal type Transfer function Accuracy Output signal range Power requirementsSupply voltage InstallationMounting Tools required EnvironmentalOperating temperature range Operating humidity range PhysicalConnections Cable length Weight Dimensions MaterialsCable Enclosure
Polymer capacitor humidity sensor Polymer capacitor humidity sensor
  • Wind resource assessment
  • Meteorological studies
  • Environmental monitoring
  • Wind resource assessment
  • Meteorological studies
  • Environmental monitoring
0 to 100% relative humidity (non-condensing) 0 to 100% relative humidity (non-condensing)
Any Symphonie Data Logger Any Symphonie Data Logger
Linear analog voltage Linear analog voltage
% Relative Humidity = Voltage x 20
  • Refer to individual calibration supplement for sensor-specific transfer function
  • Default values: % Relative Humidity = Voltage x 20
  • +/- 2% RH (k=2) from 10% to 90% RH @ 25C (77F)
  • +/- 3% RH (Maximum) from 5% to 10% RH and 90% to 95%RH@25C (77F)
  • Contact Technical Support for information on additional uncertainty due to temperature effects.
  • +/- 2% RH (k=2) from 10% to 90% RH @ 25C (77F)
  • +/- 3% RH (Maximum) from 5% to 10% RH and 90% to 95%RH@25C (77F)
  • Contact Technical Support for information on additional uncertainty due to temperature effects.
0 to 5V for 0 to 100% RH, with a load resistance greater than 10 k ohms 0 to 5V for 0 to 100% RH, with a load resistance greater than 10 k ohms
10 V to 30 V DC, 12 V at 2.6 mA typical 10 V to 30 V DC, 12 V at 2.6 mA typical
Uses a sheet metal bracket with a hose clamp, to be mounted to the tower, under the shelter box Uses a sheet metal bracket with a hose clamp, to be mounted to the tower, under the shelter box
8 mm (5/16 inch) nut driver or wrench 8 mm (5/16 inch) nut driver or wrench
-40C to 70C (-40F to 158F) -40C to 70C (-40F to 158F)
0 to 100% relative humidity (non-condensing) 0 to 100% relative humidity (non-condensing)
Wire leads, 3 conductor shielded cable:
  • Red: Power
  • Black:Ground
  • White: Signal out
Wire leads, 3 conductor shielded cable:
  • Red: Power
  • Black:Ground
  • White: Signal out
1.5 m (5 feet) 1.5 m (5 feet)
0.23 kg (0.51 lbs) 0.23 kg (0.51 lbs)
94 mm (3.7 inches) x 94 mm (3.7 inches) x 56 mm (2.2 inches) enclosure dimensions, without the bracket or shroud 94 mm (3.7 inches) x 94 mm (3.7 inches) x 56 mm (2.2 inches) enclosure dimensions, without the bracket or shroud
3 conductor 22 AWG, with overall foil shield and drain wire, chrome PVC jacket 3 conductor 22 AWG, with overall foil shield and drain wire, chrome PVC jacket
UV stabilized polycarbonate plastic box with galvanized steel mounting bracket UV stabilized polycarbonate plastic box with galvanized steel mounting bracket
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us