Post Buy Requirement
RE
Mumbai, Maharashtra, India
Add Review

Transformers #5453955

Air Cooled Variable Autotransformer

Single Phase High Current Air Cooled Variable Autotransformers each of 200A rating (Radiotone make)

We specialize in the manufacturing of Single Phase High Current Air Cooled Variable Autotransformer (colloquially known as Variac) in 100A /200A /400A /600A /800A /1200A ratings.

Three Phase units are built by using such three stacks & motorizing them on common shaft. This is a substitute for oil cooled units which are less preferred, for safety reasons, in many hazardous applications.

Single Phase High Current Air Cooled Variable Autotransformers (colloquially known as Variac) are very easy to maintain & service. Enclosed units are also available.

View Complete Details

Vertical Variable Autotransformer

Radiotone Single Layer Roller Contact Vertical Variable Autotransformer (colloquially known as Variac) construction looks like a conventional 3 phase transformer as can be seen from the picture.

Speciality of this Variable Autotransformer lies in winding Cu strip of appropriate cross section edgewise. This reduces the length of the column to 1/4 as compared to winding widthwise, thus making it compact. This column is then polished & roller carbons are made to make contact with winding for current collection. Due to circular column construction, a Double Carbon assembly can be provided giving two outputs 180 degrees out of phase (or as it is known + and - type).

Available Models :-
  1. 60A 3 Ph, 440V
  2. 60A Single Phase
  3. 100A 3 ph, 440V
  4. 100A Single Phase, 2 Phase
View Complete Details

Double Wound Isolated Variable Transformer

Engineers, Scientists, Technicians working in laboratories on sensitive equipment have a need for Isolated mains supply, with a variable output Voltage. This facilitates them in testing various devices demanding different voltages & currents. It is also an Electrical Engineering practice to test devices by applying steadily increasing voltage from 0 V to the device rated voltage. To achieve the above objective, it is normal practice to use a Variable Autotransformer (colloquially known as Variac), followed by a 1: 1 Isolation transformer or vice versa. This combination becomes very bulky & heavy with two separate transformers or even with a combined box. It also occupies much of test bench space. This is more so with increasing current rating or VA. It also loses mobility.

Radio Electric Pvt. Ltd. has solved this problem by designing Radiotone Double Wound Isolated Variable Autotransformer (colloquially known as Variac). This elegant & compact arrangement uses only ONE transformer on a single toroidal core. The Radiotone Double Wound Isolated Variable Autotransformer provides 2.5 KV Isolation between primary & secondary, primary & body with a Variable Output Voltage from 0V to the required voltage. Various models of Radiotone Double Wound Isolated Variable Autotransformer (colloquially known as Variac) are as Illustrated in the table. This concept can also be used very effectively in DC power supplies with Variable output (eg. Input 230V / 110 V, Output 0 to 25 V, 5A or 0 to 15V, 8A., etc).

We also manufacture table-top models of Radiotone Double Wound Isolated Variable Autotransformer with various types of input/output sockets (Shuko / Dual type / Round type, etc) as required.

Model Max. Power (Amp/Watts)
Radiotone DWIsoVariac 1.5 A 1.5 Amp/225 W
Radiotone DWIsoVariac 3.0 A 3.0 Amp/450 W
Radiotone DWIsoVariac 6.0 6.0 Amp/900 W
Radiotone DWIsoVariac 12 12.0 Amp/1800 W
Radiotone DWIsoVariac 20 20.0 Amp/3000 W
Radiotone DWIsoVariac30 30.0 Amp/4500 W
View Complete Details

Enclosed Variable Autotransformer

Radiotone Three Phase Enclosed Variable Autotransformer (colloquially known as Variac) models are generally used in laboratories, educational institutions, test benches for testing various industrial equipment. They can be provided with MCB, indicators and switch gear as required.

Radiotone Three Phase Variable Autotransformer open construction models from 2A to 60A can be enclosed and freely movable trolley can be provided. Output voltages can be tailor-made as required.

View Complete Details

Toroidal Transformer

Toroidal transformer is gaining more and more acceptance due to its unique features and advantages. In fact, because of its low weight & height, Toroidal transformer is being increasingly preferred over the conventional E&I transformer. In certain applications, low magnetic stray field & the low mechanical hum of Toroidal transformer are the most advantageous features. The low no load losses of the Torroidal transformer are of great value in 24 hours stand by equipment. The Toroidal transformer being custom built proves very economical in large production batches. Dual output voltages can be provided if desired. It is also possible to have primary suitable for 115Vor 230V AC, 50Hz.

A Thermal cut off can be incorporated in Toroidal transformer as a special feature at an extra cost.Our manufacturing experience of number of years has given us extensive knowledge & insight in designing the Radiotone Toroidal transformer. We use high quality material inputs in order to maintain the quality.The INSULATION between the primary & secondary winding is a fundamental safety feature, and to ensure this, we use only, BIS (Bureau of Indian Standards) approved insulating material. Special attention is given to insulation resistance, Hi-pot test & creepage distances.

View Complete Details

Variac Transformer

Open type Enclosed type, motorized ON LINE correction balancing of individual phases Models : 160A 200A 240A 300A 400A 600A 800A 1200A

View Complete Details

Double Wound Transformer

Double wound Transformer is a device that transfers energy from one circuit to another by Magnetic coupling. Apart from its ability to easily convert between different levels of Voltage & current in AC circuits, transformer also provide very useful feature called Isolation. which is the ability to couple one circuit to another without the use of direct wire connection. A very useful application of this is that even if the secondary winding is imposed a high DC voltage (wrt ground) it has no effect on the primary side. This impressed voltage is often called "Common mode Voltage as it can be seen at more than one pt in the ckt with reference to common ground. This transformer Isolates the common-mode voltage so that it is not impressed on the primary ckt at all. For that matter this could be an AC voltage, even at a different frequency & transformer will isolate it from primary side.

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

Retailer of Transformers from Mumbai, Maharashtra by radio electric india
Post Buy Requirement
RE

radio electric india

Add Review

Transformers

Our offered Product range includes Air Cooled Variable Autotransformer, Vertical Variable Autotransformer, Double Wound Isolated Variable Transformer, Enclosed Variable Autotransformer and Toroidal Transformer.

Air Cooled Variable Autotransformer

Single Phase High Current Air Cooled Variable Autotransformers each of 200A rating (Radiotone make)

We specialize in the manufacturing of Single Phase High Current Air Cooled Variable Autotransformer (colloquially known as Variac) in 100A /200A /400A /600A /800A /1200A ratings.

Three Phase units are built by using such three stacks & motorizing them on common shaft. This is a substitute for oil cooled units which are less preferred, for safety reasons, in many hazardous applications.

Single Phase High Current Air Cooled Variable Autotransformers (colloquially known as Variac) are very easy to maintain & service. Enclosed units are also available.

View Complete Details

Vertical Variable Autotransformer

Radiotone Single Layer Roller Contact Vertical Variable Autotransformer (colloquially known as Variac) construction looks like a conventional 3 phase transformer as can be seen from the picture.

Speciality of this Variable Autotransformer lies in winding Cu strip of appropriate cross section edgewise. This reduces the length of the column to 1/4 as compared to winding widthwise, thus making it compact. This column is then polished & roller carbons are made to make contact with winding for current collection. Due to circular column construction, a Double Carbon assembly can be provided giving two outputs 180 degrees out of phase (or as it is known + and - type).

Available Models :-
  1. 60A 3 Ph, 440V
  2. 60A Single Phase
  3. 100A 3 ph, 440V
  4. 100A Single Phase, 2 Phase
View Complete Details

Double Wound Isolated Variable Transformer

Engineers, Scientists, Technicians working in laboratories on sensitive equipment have a need for Isolated mains supply, with a variable output Voltage. This facilitates them in testing various devices demanding different voltages & currents. It is also an Electrical Engineering practice to test devices by applying steadily increasing voltage from 0 V to the device rated voltage. To achieve the above objective, it is normal practice to use a Variable Autotransformer (colloquially known as Variac), followed by a 1: 1 Isolation transformer or vice versa. This combination becomes very bulky & heavy with two separate transformers or even with a combined box. It also occupies much of test bench space. This is more so with increasing current rating or VA. It also loses mobility.

Radio Electric Pvt. Ltd. has solved this problem by designing Radiotone Double Wound Isolated Variable Autotransformer (colloquially known as Variac). This elegant & compact arrangement uses only ONE transformer on a single toroidal core. The Radiotone Double Wound Isolated Variable Autotransformer provides 2.5 KV Isolation between primary & secondary, primary & body with a Variable Output Voltage from 0V to the required voltage. Various models of Radiotone Double Wound Isolated Variable Autotransformer (colloquially known as Variac) are as Illustrated in the table. This concept can also be used very effectively in DC power supplies with Variable output (eg. Input 230V / 110 V, Output 0 to 25 V, 5A or 0 to 15V, 8A., etc).

We also manufacture table-top models of Radiotone Double Wound Isolated Variable Autotransformer with various types of input/output sockets (Shuko / Dual type / Round type, etc) as required.

Model Max. Power (Amp/Watts)
Radiotone DWIsoVariac 1.5 A 1.5 Amp/225 W
Radiotone DWIsoVariac 3.0 A 3.0 Amp/450 W
Radiotone DWIsoVariac 6.0 6.0 Amp/900 W
Radiotone DWIsoVariac 12 12.0 Amp/1800 W
Radiotone DWIsoVariac 20 20.0 Amp/3000 W
Radiotone DWIsoVariac30 30.0 Amp/4500 W
View Complete Details

Enclosed Variable Autotransformer

Radiotone Three Phase Enclosed Variable Autotransformer (colloquially known as Variac) models are generally used in laboratories, educational institutions, test benches for testing various industrial equipment. They can be provided with MCB, indicators and switch gear as required.

Radiotone Three Phase Variable Autotransformer open construction models from 2A to 60A can be enclosed and freely movable trolley can be provided. Output voltages can be tailor-made as required.

View Complete Details

Toroidal Transformer

Toroidal transformer is gaining more and more acceptance due to its unique features and advantages. In fact, because of its low weight & height, Toroidal transformer is being increasingly preferred over the conventional E&I transformer. In certain applications, low magnetic stray field & the low mechanical hum of Toroidal transformer are the most advantageous features. The low no load losses of the Torroidal transformer are of great value in 24 hours stand by equipment. The Toroidal transformer being custom built proves very economical in large production batches. Dual output voltages can be provided if desired. It is also possible to have primary suitable for 115Vor 230V AC, 50Hz.

A Thermal cut off can be incorporated in Toroidal transformer as a special feature at an extra cost.Our manufacturing experience of number of years has given us extensive knowledge & insight in designing the Radiotone Toroidal transformer. We use high quality material inputs in order to maintain the quality.The INSULATION between the primary & secondary winding is a fundamental safety feature, and to ensure this, we use only, BIS (Bureau of Indian Standards) approved insulating material. Special attention is given to insulation resistance, Hi-pot test & creepage distances.

View Complete Details

Variac Transformer

Open type Enclosed type, motorized ON LINE correction balancing of individual phases Models : 160A 200A 240A 300A 400A 600A 800A 1200A

View Complete Details

Double Wound Transformer

Double wound Transformer is a device that transfers energy from one circuit to another by Magnetic coupling. Apart from its ability to easily convert between different levels of Voltage & current in AC circuits, transformer also provide very useful feature called Isolation. which is the ability to couple one circuit to another without the use of direct wire connection. A very useful application of this is that even if the secondary winding is imposed a high DC voltage (wrt ground) it has no effect on the primary side. This impressed voltage is often called "Common mode Voltage as it can be seen at more than one pt in the ckt with reference to common ground. This transformer Isolates the common-mode voltage so that it is not impressed on the primary ckt at all. For that matter this could be an AC voltage, even at a different frequency & transformer will isolate it from primary side.

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us