Therma Chill Water Heating Systems (air Source Heating or Heat Pump Systems) Therm Chill Tch 1000/2000/5000/10000 Therm Chill Tch- 1000/2000/5000/10000 Works On the Latest Technology Specially Designed to Full Fill Your Demands of Hot Water, Round the Year At the Most Economic Cost. It Saves You Up to 75% of Electricity, if Compared to the Use of Water Coolers and Electric Geysers, Using Only 25% of Energy, Just to Operate the System. It is a Clean and Green Product with Zero Pollution, Unlike Any Wood, Oil or Diesel Boiler. Therm Chill Tch -1000/2000/5000/10000 is the Best Solution for Hostels, Resorts, Hotels, Industries and Homes Due to Its Economic and Compact Design. It is the Worldwide Accepted Technology for Efficient and Economic Swimming Pool Heating. Lowest Maintenance and Replacement Warranty for One Year, Therm Chill is Your Best Choice for Your Hot Water Needs.
Additional Information:
Payment Terms : T/T, Western Union
Delivery Time : 15 Days (Min.)
Additional Information:
Payment Terms : T/T, Western Union
Delivery Time : 15 Days (Min.)
We offer air to water heating systems. It uses heat pump technology to increase the temperature of water. It absorbs heat from air, concentrates it and passes it down to water. Power consumption is very less. Very useful for swimming pools, hotels, hostels, hostels etc.
Additional Information:
Payment Terms : T/T, Western Union
Packaging Details : WOODEN
Delivery Time : ONE MONTH
it is the most economic and dependable water heating system suitable for residences, hotels, hostels , hospitals, swimming pools and a number of industries.
.Additional Information:
Payment Terms : L/C, D/A, Western Union,
Packaging Details : WOODEN PACKING AVAILABLE FOR CUSTOMERS OTHER THAN HYDERABAD
Delivery Time : 15 DAYS
The Industrial Water Heating System offered by Quickbird Refrigeration And A.C. Works is not only long long-lived but also provides incomparable performance, which creates more unique and demanding in the global market. Our company is one of the reputed Manufacturers, Exporters and Suppliers of Industrial Water Heater from Andhra Pradesh (India). Till now, we have also developed an innovative Water Heating Cum Cooling System that can easily save power up to 80%. Our quality array of products can absorb the heat from atmospheric air and then lastly it is being transferred into water. The electricity is used just to run the system and not to directly heat water. It also helps in saving customers nearly 75% to 80% of power. Further, these are available in compact designs and are also eco friendly in functioning, thus reducing possibility of global warming.
Features of Industrial Water Heater
Applications of Industrial Water Heating System
Water Heating Unit Model | TCH | 1000 | 2000 | 5000 | 10000 |
Parameter | Unit | Value | Value | Value | Value |
Water Heating Capacity | L/Hr | 100 | 200 | 500 | 1000 |
Power in put | Kw/Hr | 1.25 | 2.5 | 6.25 | 12.5 |
No. of units | No | 1 | 1 | 1 | 1 |
Water inlet temp. (Approx) | oC | 20-30 | 20-30 | 20-30 | 20-30 |
Water outlet temp(Approx) | oC | 50-60 | 50-60 | 50-60 | 50-60 |
Water volume to be heated | Litres | 1000 | 2000 | 5000 | 10000 |
Heating time for above mentioned volume | Hrs. | 10 hrs. | 10 hrs. | 10 hrs. | 10 hrs. |
Total Energy Consumption(With20% wastage) | Rs/Hr | 10.5 | 21 | 52.5 | 105 |
Power tariff (assumed) | Rs. | 7 | 7 | 7 | 7 |
Operating cost for Heating above mentioned volume. | Rs | 105 | 210 | 525 | 1050 |
Max .Output Hot water Temp. | oC | 60 | 60 | 60 | 60 |
Operating temp range(Ambient) | oC | 10’~50 | 10’~50 | 10’~50 | 10’~50 |
Material | - | Stainless steel | S.S. | S.S. | S.S. |
Therm `O’ chill foot print | Sqmt | 0.25 | 0.35 | 0.5 | 1 |
Volume of swimming pool water which could be heated up to 35’c | Liters | 10000 | 20000 | 50000 | 1,00,000 |
Comparative Data
Water To Be Heated | 1000 Liters |
Water inlet Temperature | 30 oC |
Water Outlet Temperature | 50 oC to 60 oC |
Parameter | Unit | Diesel Boiler | Electric Geyser | Solar Heater | Therm’O’ChillTMTCH-1000 |
Energy Consumption /day | Lts (or)KWH | 10Ltrs of Diesel | 48 KWHR | 48 KwHr | 15 KwHr |
Power/Fuel Rate | Rs. | Rs.45.00 | Rs.7.00 | Rs.7.00 | Rs.7.00 |
Operating Cost / day | Rs. | Rs.450 | Rs.336 | Rs.336 | Rs.105 |
No. of days used in a year | Days | 365 | 365 | *115 | 365 |
Operating Cost / Year(Heating) | Rs. | Rs.164250 | Rs.121545 | Rs.38640 | Rs.38325 |
Why Therm‘O’ ChillTM TCD-1000/2000/5000/10000
Solar Water Heater | Therm'O'ChillTM TCH-1000/2000/5000/10000 |
High Initial Investment | Lower Initial Investment |
Not reliable in monsoons, when hot water is needed the most; forcing you to use electric heater / diesel boilers, increasing your operating cost. | 100% reliable, works in all weather conditions, with the lowest energy consumption. |
Does not work at night, if hot water is used up, there will be no hot water available for the morning. | Works 365 days and nights a year. |
Must be installed on roof top | Does not need sun light; can be installed anywhere; including the cellar. |
Takes up a lot of space; wasting lot of usable and valuable terrace space. | Very compact, no paneling. Takes up a fraction of the space. |
Is not efficient in cold/cloudy places, shadowed buildings. | Ideal solution; does not depend on sunlight. |
Relocation is difficult | Very easy to relocate |
Spoils the look of your home / Hotel / Resort. | Not visible from the outside of the building. |
Note: Solar Works For Only 250 Days A Year, Electric Backup/diesel Boiler, Etc. Must Be Used For Remaining Number Of Days.
Boilers | Therm O ChillTM TCH-1000/2000/5000/10000 |
Rising fuel prices, meaning high and increasing running cost. | Runs on very little electricity, hence lower and stable running cost. |
Requires separate infrastructure/ storage room etc. | No special infrastructure, no separate storage space. |
Risk of shortage/ untimely fuel supply. | Electricity is readily and universally available. |
Faces probable ban by the government | No such risk, is eco-friendly and does not pollute the environment. |
Staff required for manual operation. | Fully automatic operation. |
Electric Geyser | Therm O ChillTM TCH-1000/2000/5000/10000 |
Extremely high operating cost | Saves you up to 75% electricity |
Not reliable during power cuts | Stores required amount of hot water in an insulated tank, hence more reliable during power cuts. |
Only 75% efficient | 300% more efficient than conventional heating methods. |
Quickbird Refrigeration And A.C. Works is presenting an exclusive array of Centralized Water Heating Systemthat is offered by us with the best packaging solutions. The company is well settled with large manufacturing unit that is occupied with advanced machinery.Being a reputed Central Water Heater Manufacturer, we offer our products with quality features like, rust resistance, robust construct, power saving, etc. These are precision fabricated body that offer high functionality and service life standards, owing to which, we are accredited as one of the reputed Manufacturers, Exporters and Suppliers of Central Water Heater from Hyderabad, India.
Features Of Central Water HeaterApplications of Centralized Water Heating System
Parameter | Unit | Tank 1 | Tank 2 |
Water Heating Capacity | L/HR | - | 100 |
Water Cooling Capacity | L/HR | 100 | - |
Power in put (per hour) | Kw | 1.25 | - |
No. of units | No | 1 | - |
Total Cooling/heating capacity | L/HR | 200 | - |
Total power input (per hour) | KW | 1.25 | - |
Water inlet temp. (Approx) | oC | 30 | 30 |
Water outlet temp(Approx) | oC | 515 | 50-60 |
Water volume to be Cooled/heated | Litres | 1000 | 1000=2000 |
Cooling/heating time for 2000Ltrs | Hrs. | 10 hrs. | - |
Total Energy Consumption(With20% wastage) | Rs/Hr | 10.5 | - |
Power tariff (assumed) | Rs. | 7 | - |
Operating cost for Cooling&Heating 2000Ltrs. | Rs | 105 | - |
Max .Output Hot water Temp. | oC | 50-60 | - |
Min. output cool water Temp | oC | 515 | - |
Operating temp range(Ambient) | oC | 1050 | - |
Material | - | - | Stainless steel |
Therm `O chill foot print | Sqmt | 0.5 | - |
Parameter | Unit | Tank 1 | Tank 2 |
Water Heating/Cooling Unit Model | TCD | 2000 | - |
Water Heating Capacity | L/HR | 200 | |
Water Cooling Capacity | L/HR | 200 | - |
Power in put (per hour) | Kw | 2.5 | - |
No. of units | No | 1 | - |
Total Cooling&heating capacity | L/HR | 400 | - |
Total power input (per hour) | KW | 2.5 | - |
Water inlet temp. (Approx) | oC | 30 | 30 |
Water outlet temp(Approx) | oC | 515 | 50-60 |
Water volume to be Cooled&heated | Litres | 2000 | 2000=4000 |
Cooling/heating time for 4000Ltrs | Hrs. | 10 hrs. | - |
Total Energy Consumption(With20% wastage) | Rs/Hr | 21 | - |
Power tariff (assumed) | Rs. | 7 | - |
Operating cost for Cooling&Heating 4000Ltrs. | Rs | 210 | - |
Max .Output Hot water Temp. | oC | 50-60 | - |
Min. output cool water Temp | oC | 515 | - |
Operating temp range(Ambient) | oC | 1050 | - |
Material | - | - | Stainless steel |
Therm `O chill foot print | Sqmt | 0.5 | - |
Parameter | Unit | Tank 1 | Tank 2 |
Water Heating Capacity | L/HR | 500 | |
Water Cooling Capacity | L/HR | 500 | - |
Power in put (per hour) | Kw | 6.25 | - |
No. of units | No | 1 | - |
Total Cooling&heating capacity | L/HR | 1000 | - |
Total power input (per hour) | KW | 6.25 | - |
Water inlet temp. (Approx) | oC | 30 | 30 |
Water outlet temp(Approx) | oC | 515 | 50-60 |
Water volume to be Cooled&heated | Litres | 5000 | 5000=10, 000 |
Cooling/heating time for 10, 000Ltrs | Hrs. | 10 hrs. | |
Total Energy Consumption(With20% wastage) | Rs/Hr | 52.5 | |
Power tariff (assumed) | Rs. | 7 | |
Operating cost for Cooling&Heating 10, 000Ltrs. | Rs | 525 | |
Max .Output Hot water Temp. | oC | 50-60 | |
Min. output cool water Temp | oC | 515 | |
Operating temp range(Ambient) | oC | 1050 | |
Material | - | - | Stainless steel |
Therm `O chill foot print | Sqmt | 0.5 | - |
Water Consumption | Liters | 1000[hot] | 1000[cold] |
Water inlet Temperature | oC | 30 | 30 |
Water Outlet Temperature | oC | 50 to 60 | 10 |
Parameter | Unit | Diesel Boiler | Electric Geyser | Solar Heater | ThermOChillTMTCD-1000 |
Energy Consuption /day | Lts (or)Kwh | 10 | 48 | 48 | 15 |
Power / Fuel Rate | Rs. | 45 | 7 | 7 | 7 |
Operating Cost / day | Rs. | 450 | 336 | 336 | 105 |
No. of days used in a year | Days | 365 | 365 | *115 | 365 |
Operating Cost / Year(Heating) | Rs. | 164250 | 121545 | 38640 | 38325 |
Energy Consunption / day for 100 lts water coolers X10 Nos working 5 hrs per day | Kwh | 40 | 40 | 40 | - |
Operating Cost / year (Cooling) | Rs. | 102200 | 102200 | 102200 | - |
Net Operating Cost / Year | Rs. | 266450 | 223745 | 140840 | 38325 |
Saving / Year if TCD is used | Rs. | 228125 | 185420 | 102515 | - |